Surface Texture Gage study in the qs-stat Measurement System Analysis Module

Similar documents
Technical Procedure for Instrument Calibration and Maintenance

Calibration Procedure

HOW TO SETUP ROUND ROBIN IN DARTS FOR WINDOWS

FIBA Europe Coaching Website. Manual. Practice Section

Operating Instructions METTLER TOLEDO Pipette Check Application for AX and MX/UMX Balances Version 1.xx

Operating Manual. SUPREMA Calibration. Software for Fire and Gas Warning Units. Order No.: /01. MSAsafety.com

Viva TPS. TS11/15 Total Stations Check and Adjust Procedure. October Summary

P3000 Deadweight Tester Setup, Part 1: Limited Partial Correction Method

AKTA pure 25 New Owner s Intro

Trial # # of F.T. Made:

USA Jump Rope Tournament Software User Guide 2014 Edition

American Thoroughbred Handicapping Program

Initial Velocity (IV) Test Replacement

NCSS Statistical Software

UNITY 2 TM. Air Server Series 2 Operators Manual. Version 1.0. February 2008

iscore Help Import a Game & Set a Lineup

1)! DO NOT PROCEED BEYOND THIS MARK

Entering Immunization Data

SWIM MEET MANAGER 5.0 NEW FEATURES

To Enter a Game sheet:

How to Set Up Your League

FireHawk M7 Interface Module Software Instructions OPERATION AND INSTRUCTIONS

FireWorks NFIRS BI User Manual

LX Compass module 3 Electronic compass device User manual

MJA Rev 10/17/2011 1:53:00 PM

Calibration Procedure

A GUIDE TO THE LOOSE ENDS HOCKEY LEAGUE WEBSITE PAGE

TESLAGON. ShotHelper Manual. How to install and use the Program. Version /30/2014

England Handball Association Membership and Registration Information Updated: June 2018

TEXAS DEPARTMENT OF PUBLIC SAFETY Breath Alcohol Laboratory

Hertfordshire Girls Football Partnership League Promoting the development of girl s football in Hertfordshire

The HumiPyc - Model 1 - Gas Pycnometer; Density, Moisture, Permeation Analyzer; RH sensor Calibrator

Sail Chart Drafter for Deckman v.2

DakStats Football Quick Start Guide 1 of 7

[CROSS COUNTRY SCORING]

Click on the menu icon in the left corner to open the menu. From the menu you can:

GolfLogix: Golf GPS. User Guide for: BlackBerry Curve. Version 1.0. Software Release , 8330, 8350i, 8800, 8820, 8830, 8900

PROGRAMMING LINX LEARNING GAME

Race Screen: Figure 2: Race Screen. Figure 3: Race Screen with Top Bulb Lock

Instruction Manual. BZ7002 Calibration Software BE

[CROSS COUNTRY SCORING]

PREPARED BY: Marshall K. Cheung, Ph.D., Laboratory Director. REVISED BY: Marshall K. Cheung, Ph.D., Laboratory Director

RM-80 respiration monitor

Swing Labs Training Guide

Quantos Automated Dosing Solution Preparation Precise concentrations Process compliance Minimize out-of-specs

GolfLogix: Golf GPS. User Guide for: iphone 3G & 3GS. Version 1.0. Software Release 1.0

Greater Portland City League Tennis FAQ. Table of Contents

10 The Performance Assessment Report

Lab 1: Pressure and surface tension. Bubblers, gravity and the mighty paper clip.

Pegas 4000 MF Gas Mixer InstructionManual Columbus Instruments

Calibration of a GC955

MASSACHUSETTS STATE POLICE CRIME LABORATORY. Certificate of Calibration Procedure for the Alcotest 9510

Introducing Version 7R2

Figure 1 Example feature overview.

OMNISPORT 2000 SWIMMING QUICK REFERENCE

Computer Scorekeeping Procedures

O2100C Oxygen Measurement Module Technical Use Notes do not use other wall adapters with the O2100Cmodule. 10% / V 5% / V 2% / V 1% / V 10% / V

IMPORTANT: All features subject to change without notice.

Felix and Herbert. Level. Introduction:

Race Area Analyzer Solent

KIV-SACS Safe automatic calibration system:

[MYLAPS INTEGRATION]

Creating a New Player and Registering them with the League

Page 1 GM-FAQ Club Profile FAQs. Page

How to Setup and Score a Tournament. May 2018

Operation of the Perkin Elmer TGA-GC/MS

Proficiency Testing for Surface Roughness Standard and Groove Depth Standard

Hazard Training Guide

Managing Timecard Exceptions

UNDERGROUND SURVEY WITH MINEMODELLER

PosiTector UTG, UTG-STD & UTG-ME

Computer Scorekeeping Procedures Updated: 6/10/2015

Computer Scorekeeping Procedures Page 1

The HumiPyc ( Model 2) - Gas Pycnometer; Density, Moisture, Permeation Analyzer; Filter Integrity Tester; RH sensor Calibrator

For running only the scoresheet application without any video features only some very basic hardware / software requirements have to be fulfilled:

Calibration Procedure. PosiTest DFT Combo

Sailwave Scoring Instructions for Thursday Night Races 2017

Axis Camera with VaxALPR On Camera software: License key

GMS 10.0 Tutorial SEAWAT Viscosity and Pressure Effects Examine the Effects of Pressure on Fluid Density with SEAWAT

uemis CONNECT: Synchronisation of the SDA with myuemis

szen Eighteen Full Manual 2010 szen Corp

USER GUIDE. Download the latest version at: v by Rob Rubin

How to evaluate pressure measurement specifications

JETFIRST 150 RTA SYSTEM OPERATING MANUAL Version: 2 Feb 2012

FOOTBALL WEST. Sports TG User Guide. Club Administrators

Competition Management Online User Guide for Basketball

K 460K K 470K

Vapor Sorption Analyzer

BIOGAS COMBUSTION PLANT MAINTENANCE MANUAL

Hydro-Control V User Guide

WELCOME TO THE FUTURE OF TELEVISION. User Manual

Predicted Dispense Volume vs. Gravimetric Measurement for the MICROLAB 600. November 2010

Controls and Control Charting

Evaluation copy. Wind Chill. computer OBJECTIVES MATERIALS

User s Booklet for the Wyatt minidawn Light Scattering Instrumentation

2017 FFV Sports TG User Guide STG Online Results Match Official User Guide

Kestrel HVK Gun Loader Sofware

GNX 20/21. Owner s Manual

Golfshot: Golf GPS. ios VERSION 3.0+

Table of Contents. Hume s Guide for Running Fieldlynx Polaroid sun glasses do not work real well with the Palm Pilot screen.

Transcription:

study in the qs-stat Measurement System Analysis Module Q-DAS Library Living Documentation Last edited: 11/22/2004 Version: EB C:\Documents and Settings\Ellen Fassbeck\My Documents \My Temp Files\GMPT\TC\GMPT Surface texture MSA in qs- Stat_eb.doc

Table of Contents 1 PROCEDURE............ 3 1.1 CALIBRATION STUDY............ 3 1.2 PREPARATORY STUDY............ 3 1.3 TYPE 2 STUDY............ 4 2 REQUIRED SETUP IN QS-STAT......... 5 3 EXAMPLE FOR A SURFACE TEXTURE STUDY IN QS-STAT...... 12 3.1 CALIBRATION STUDY............ 12 3.2 PREPARATORY STUDY............ 13 3.3 TYPE-2 ANOVA GR&R STUDY......... 14 3.4 SURFACE TEXTURE STUDY IN QS-STAT......... 15 2

Surface Texture Gage 1 Procedure 1.1 Calibration study The system must be checked for proper function and calibrated before starting the Study, using a 3 patch precision reference standard and where required an appropriate calibration fixture. Verify the system by checking 5 times on each patch and calculate the average of the readings. This average must be within 5% of the known calibrated value. Calibration to the first patch sets gain, the second patch verifies linearity and the third patch validates the stylus. Completion of these tests shall demonstrate the instruments Accuracy and Linearity. (quote from SP-Q-EMS-GLOBAL, chapter 3.10.1 Surface texture gages) 1.2 Preparatory study A preparatory study for each to be evaluated feature is conducted. Features are for example: Ra, Rmax, Rz, Wt, etc. Surface Texture gages present a unique challenge to measurement systems analysis in that the variation in the parts may be large in comparison to the specification tolerance. Therefore, a preparatory study must be conducted to quantify the piece variation. Select a part that is a representative of the process to be analyzed by the instrument. Measure 25 traces in one position (Do not move part or instrument). From these trace results, calculate the instrument standard deviation s i. Repeat step 2 with a minor incremental movement of the stylus relative to the part, each time perpendicular to the lay. Measure 25 traces. From these trace results, calculate the total deviation s t. Calculate standard deviation within part s s (quote from SP-Q-EMS-GLOBAL, chapter 3.10.1 Surface texture gages) The standard deviation surface Ss for each feature is calculated with: s s = s 2 2 t - s i 3

1.3 Type 2 study Then a type 2 study is conducted. As it is impossible to eliminate the surface variation during the study, the calculated Surface Variation SV is subtracted from the normal R&R result. The resulting Surface Variation is calculated out of the R&R value with RR=(EV 2 +AV 2 +IA 2 -SV 2 ) 0.5 With SV=5.15*Ss (SV=Surface Variation; variation range of 99%) and EV (Equipment Variation), AV (Appraiser Variation) and IA (InterAction) calculated according the ANOVA method. Reference figure for the %G&R is the tolerance of each feature Requirements are Measurement system capable: %R&R </= 20% Measurement System conditionally capable: 20% </= %R&R </= 30% 4

2 Required Setup in qs-stat 1. Switch to the Measurement System Analysis module 2. call up or create an evaluation strategy under OPTIONS/CONFIGURATION OF EVALUATION which includes the following three study types: SURFACES CALIBRATION, SURFACES -PREPARATORY and TYPE 2 STUDY 5

3. settings for SURFACES -CALIBRATION: 6

4. settings for SURFACES -PREPARATORY 7

8

5. settings TYPE 2 STUDY 9

10

The so configured evaluation strategy needs to be selected before starting a new surface texture study file. 11

Surface Texture Gage 3 Example for a Surface Texture Study in qs-stat 3.1 Calibration Study CALIBRATION STUDY DATA FOR Ra ONLY Trace # Calibration Patch Linearity Patch Stylus Check Patch* 1 0.002988 0.000315 0.000406 2 0.002993 0.000317 0.000438 3 0.002995 0.000316 0.000436 4 0.002997 0.000316 0.000442 5 0.002992 0.000316 0.000405 Average 0.002993 0.000316 0.000398 Certified Patch Value 0.00297 0.00031 0.00043 Certified Value +5% 0.003119 0.000326 0.0005 Certified Value -5% 0.002822 0.000295 0.0003 Is average within Certified Value +/- 5%?, YES YES YES *Note: If using a 5 micron radius stylus on a PDR-6 Precision, Reference Standard (from Precision Devices, Inc.) Stylus Check patch, add 0.04 micron to the certified patch value. This correction applies to only the Stylus Check patch.,,,,,,,,,, If the average of the measurements are within +/-5% of the Certified Patch Value, proceed with the preparatory study. Remark: the Calibration study results in this table were calculated in Excel. 12

3.2 Preparatory Study Example data for 2 features: Rz and Wt 25 traces in 1 position 25 traces with repositioning after each Trace # Rz [mm] Wt [mm] Trace # Rz [mm] Wt [mm] 1 0.000627 0.000666 1 0.000462 0.000343 2 0.000744 0.000625 2 0.000653 0.000396 3 0.000479 0.000471 3 0.00063 0.000437 4 0.000546 0.000495 4 0.000461 0.000401 5 0.000502 0.000408 5 0.001482 0.000473 6 0.000422 0.000367 6 0.000507 0.000412 7 0.000478 0.00038 7 0.000568 0.000405 8 0.000278 0.000439 8 0.001087 0.00081 9 0.000569 0.000412 9 0.000384 0.000493 10 0.00043 0.000427 10 0.000808 0.00049 11 0.000628 0.00038 11 0.000888 0.000457 12 0.000633 0.000448 12 0.000959 0.000578 13 0.000633 0.000426 13 0.000395 0.000387 14 0.00057 0.000386 14 0.00202 0.000727 15 0.000553 0.000417 15 0.000956 0.000537 16 0.000478 0.000367 16 0.000502 0.000541 17 0.000493 0.000417 17 0.001103 0.000505 18 0.000498 0.00038 18 0.000088 0.000586 19 0.00048 0.000368 19 0.000701 0.000416 20 0.000452 0.000365 20 0.002395 0.000947 21 0.00046 0.00042 21 0.00083 0.000463 22 0.000404 0.000355 22 0.000101 0.000455 23 0.000527 0.000392 23 0.001092 0.000623 24 0.000498 0.000396 24 0.000893 0.000403 25 0.000403 0.000359 25 0.000942 0.000717 S i = 0.000627 0.000666 S t = 0.000462 0.000343 13

3.3 TYPE-2 ANOVA GR&R STUDY for 5 parts, 2 operators and 3 trials Feature 1: Rz [mm] Operator A Operator A Operator A Operator B Operator B Operator B Piece # Trial 1 Trial 2 Trial 3 Trial 1 Trial 2 Trial 3 1 0.000609 0.001812 0.002492 0.00038 0.002079 0.000114 2 0.001109 0.001004 0.000743 0.001591 0.00166 0.001684 3 0.002887 0.003366 0.002618 0.003927 0.004123 0.004009 4 0.002146 0.001651 0.002556 0.00124 0.001452 0.001377 5 0.003305 0.003713 0.006362 0.005451 0.005742 0.005917 Feature 2: Wt [mm] Operator A Operator A Operator A Operator B Operator B Operator B Piece # Trial 1 Trial 2 Trial 3 Trial 1 Trial 2 Trial 3 1 0.000613 0.000649 0.000848 0.000588 0.001 0.000508 2 0.000586 0.000592 0.000477 0.000708 0.000712 0.000701 3 0.001104 0.001197 0.001219 0.000995 0.00101 0.001026 4 0.000831 0.000623 0.000879 0.000655 0.000822 0.000602 5 0.001905 0.001983 0.002658 0.002573 0.002532 0.002515 14

3.4 Surface Texture Study in qs-stat 1. select the menu function FILE / FILE NEW 2. Pick 1 characteristics for the Surfaces Overall and, here, 2 characteristics for each the Surfaces Preparatory and Type 2 study (Rz and Wt): 15

3. A blank parts and characteristics mask appear on the screen. First, the parts mask should be filled out. 4. After the parts data is entered, the parts mask can be closed. Only the characteristics mask is left on the screen and can be filled out. The active characteristic should be the first one, the Overall - : 16

5. If you want to perform a calibration study in addition to the preparatory and type 2 study, please open up a Parts-/ characteristics list from the Summary menu item 6. Insert a new characteristic for the calibration study in front of the preparatory study with a right mouse-click 17

7. Hit the Execute evaluation icon, close the Parts-/ characteristics list and go back to the Characteristics Mask. In order to get a better overview over the available characteristics, a Characteristics List can also be shown in the characteristics mask. To do so, make sure the characteristics mask is active and click on the Info - button Check the box for Characteristic list 8. The list in the can be used to navigate through the different characteristics. To fill out the information for the Calibration study, click on the second characteristi c in the list. A blank characteristic mask should come up. Double check the setting under type whether it displays Surfaces - Calibration and fille out the required information. Set the number of parts to 3 the number of reference measureme nts to 1 and the number of repetitions to 5. Confirm each entry with the Enter key. The Unit for all characteristics and values should be mm. 18

9. Rz Preparatory study. Double check the settings for evaluation type whether it is set to Preparatory study. Set the Number of marks and number of Repetitions to 25. Enter Characteristic number, description, Nominal and Upper and lower Specification limits and gage resolution. For a Surface Texture Study, it is very important to set the Measured Quantity to Rz. The information of the measured quantity is used to connect the preparatory study and the type 2 study characteristics. 10. Switch the characteristic and fill out the mask for the Rz Type 2 study. The information for the measured quantity needs to be set the same as it is set in the associated preparatory study. 19

11. Switch to the Characteristics Mask for the Wt characteristic and fill out the information for the preparatory and the Type 2 study accordingly. 12. Close the Characteristics Mask 20

13. Enter or Copy and paste the Measurement Values for each characteristic into the Values Mask (unit: mm) 14. Close the Values Mask. 15. Define the Characteristics Structure: The characteristics for the Overall needs to be set as an superimpos ed Characteristic. To do this, please open up a Parts- /Characteristics list. 21

16. Drag and drop all other characteristics under the overall evaluation characteristic: if a characteristic for the calibration study was added, this characteristic needs to b dragged and dropped under the overall evaluation characteristic as well so that all characteristics are sub-ordinate to the overall evaluation characteristic. 17. The characteristics structure should look like this: 18. Close the Part / characteristics list and Execute the with the Calculator button. 22

19. Bring up the Charts, for example the Form Sheet 3 for the first Overall result characteristic. It will only display a Smiley face if all studies have been passed. A question mark appears, if one or more characteristics are conditionally capable and all others are capable and a frowny face will be displayed, if one characteristic did not pass. 20. Switch to the next characteristic and bring up the Charts, for example the Value Chart Individuals, the Individual Values Chart (under Numerics ) and the Form 3 for the Calibration study The displayed results in the Form 3 refer to the maximum deviation of all three calibration patches. If one calibration patch fails, the whole calibration study is failed. 23

21. The Value Chart Individuals and the Form 3 for the Preparatory study: The numerical values Si, St and the Standard deviation Surface Ss have been calculated and are available on the Form 3. 24

22. Switch to the Type 2 studies. The Surface Variation SV has been calculated using the Ss from the associated preparatory study. The GR&R value is calculated with RR=(EV 2 +AV 2 +IA 2 -SV 2 ) 0.5 25