Development of Prediction Models for Spent Nuclear Fuel Storage Cask Monitoring Hyong Chol Kim, Sam Hee Han, Dong Jae Park

Similar documents
START UP MODELING OF KAIST MICRO MODULAR REACTOR COMPRESSOR USING BETA LINE METHOD WITH GAMMA+ CODE

Visual Observation of Nucleate Boiling and Sliding Phenomena of Boiling Bubbles on a Horizontal Tube Heater

Influence of Ambient Temperature on Performance of a Joule-Thomson Refrigerator

Neural Networks II. Chen Gao. Virginia Tech Spring 2019 ECE-5424G / CS-5824

A Numerical Study of the Performance of a Heat Exchanger for a Miniature Joule-Thomson Refrigerator

Performance Monitoring Examples Monitor, Analyze, Optimize

Noise Characteristics Of A Check Valve Installed In R22 And R410A Scroll Compressors

HTR Systems and Components

SAFETY DEMONSTRATION TESTS ON HTR-10

Heat Transfer Research on a Special Cryogenic Heat Exchanger-a Neutron Moderator Cell (NMC)

Micro Channel Recuperator for a Reverse Brayton Cycle Cryocooler

Reproducing Failure Mode and Life Prediction of Expansion Joint Using Field Data

OIL SUPPLY SYSTEMS ABOVE 45kW OUTPUT 4.1 Oil Supply

2. Determine how the mass transfer rate is affected by gas flow rate and liquid flow rate.

HYDROGEN - METHANE MIXTURES : DISPERSION AND STRATIFICATION STUDIES

Dynamic Operation of a 4 K Pulse Tube Cryocooler with Inverter Compressors

Flow and Mixing in the Liquid between Bubbles

HYDROGEN FAST FILLING TO A TYPE IV TANK DEVELOPED FOR MOTORCYCLES

29th Monitoring Research Review: Ground-Based Nuclear Explosion Monitoring Technologies

Available online at ScienceDirect. Physics Procedia 67 (2015 )

Transportation Package Seal Performance in Beyond Design Basis Thermal Exposures 12472

Start-up of the Three-shaft Closed Loop

Experimental Analysis of Inclined Narrow Plate-Fins Heat Sink under Natural Convection

Development of High Efficiency 4K Two-Stage Pulse Tube Cryocooler

WALL BOILING MODELING EXTENSION TOWARDS CRITICAL HEAT FLUX. ABSTRACT

Simulation and Experimentation on the Contact Width of New Metal Gasket for Asbestos Substitution

DYNAMIC CRUSH TEST ON HYDROGEN PRESSURIZED CYLINDER

Experimental Determination of Temperature and Pressure Profile of Oil Film of Elliptical Journal Bearing

CFD Analysis of the Anti-Surge Effects by Water Hammering

OPTIMIZATION OF RECUPERATER FIN GEOMETRY FOR MICRO GAS TURBINE

Wind tunnel effects on wingtip vortices

BAM - 3.2: Section Pressure Equipment Pressure Receptacles; Fuel Gas Storage Systems 26 th September 2014

Development of Helium Leak Testing System and Procedure for testing Welds of Steam Generator

Study on Fire Plume in Large Spaces Using Ground Heating

MIL-STD-883G METHOD

BENCHMARK OF COMPUTATIONAL FLUID DYNAMICS SIMULATIONS USING TEMPERATURES MEASURED WITHIN ENCLOSED VERTICAL AND HORIZONTAL ARRAY OF HEATER RODS.

LEAKAGE EFFECTS ON THE RATE OF CHANGE OF PRESSURE AT THE PIPELINE EXIT. Seungyong Chang Korea Gas Corporation, R&D Training Center

v. Size shall be specified on drawings.

Leak Checking Large Vacuum Chambers

Monitoring Gas Pressure in Vacuum Insulation Panels

Guideline No.M-05(201510) M-05 AIR COMPRESSOR. Issued date: 20 October China Classification Society

EFFECT OF AL 2 O 3 - WATER NANO FLUID ON BUBBLE SPACING IN SUBCOOLED FLOW BOILING IN A HORIZONTAL ANNULUS

Diagnosis of Fuel Evaporative System

Wind Pressure Distribution on Rectangular Plan Buildings with Multiple Domes

Numerical simulation of the ALBA s synchrotron cooling system response to pump start-up and shut-down Page 1

A COMPARATIVE STUDY OF MIX FLOW PUMP IMPELLER CFD ANALYSIS AND EXPERIMENTAL DATA OF SUBMERSIBLE PUMP

Safety Systems Based on ND Pressure Monitoring

EXPERIMENTAL STUDY ON HYDROGEN EXPLOSIONS IN A FULL-SCALE HYDROGEN FILLING STATION MODEL

THERMAL PERFORMANCE COMPARISON OF GLASS MICROSPHERE AND PERLITE INSULATION SYSTEMS FOR LIQUID HYDROGEN STORAGE TANKS

6995(Print), ISSN (Online) Volume 4, Issue 1, January- April (2013), IAEME TECHNOLOGY (IJDMT)

International Journal on Emerging Technologies 4(2): 21-26(2013) ISSN No. (Print) : ISSN No. (Online) :

Step Detection Algorithm For Accurate Distance Estimation Using Dynamic Step Length

Experimental Investigation on Stirling type Thermally Coupled Three Stage Pulse tube Cryocoolers with U type Configuration

INTERACTION BETWEEN WIND-DRIVEN AND BUOYANCY-DRIVEN NATURAL VENTILATION Bo Wang, Foster and Partners, London, UK

Comparison of MARS-KS to SPACE for counter current flow limitation model

Experimental Characterization and Modeling of Helium Dispersion in a ¼-Scale Two-Car Residential Garage

Profile LFR-43 HELENA ITALY. Italian National Agency for New Technologies, Energy and Sustainable Economic Development, C.R. ENEA Brasimone, Italy

MEASUREMENTS ON THE SURFACE WIND PRESSURE CHARACTERISTICS OF TWO SQUARE BUILDINGS UNDER DIFFERENT WIND ATTACK ANGLES AND BUILDING GAPS

ABNORMALLY HIGH STORM WAVES OBSERVED ON THE EAST COAST OF KOREA

FAILURE AND HAZARD ANALYSIS OF THE NPDGAMMA LH2 TARGET SYSTEM

HELIUM PRESSURE REGULATOR

Mitsubishi Heavy Industries Technical Review Vol. 53 No. 4 (December 2016)

Reflux Condensation with Various Non-Condensable Gases

Deborah Houssin-Agbomson, Jean-Yves Letellier, Philippe Renault, Simon Jallais

Mass Flow Controller (MFC) for Gases

VINDKRAFTNET MEETING ON TURBULENCE

Applications of Collected Data from Argos Drifter, NOAA Satellite Tracked Buoy in the East Sea

IJSRD - International Journal for Scientific Research & Development Vol. 4, Issue 06, 2016 ISSN (online):

Impulsive Pressurization of Neuronal Cells. M. Nienaber, J.S. Lee, R. Feng and J.Y. Lim

Cooling Characteristics of GM-type Pulse Tube Refrigerator with Neon as Working Gas

Yasuyuki Hirose 1. Abstract

better measurement Simply a question of SCHMIDT Flow Sensor SS The cost-effective alternative in pressurised systems up to 10 bars.

THE STUDY ON THE INTERNAL TEMPERATURE CHANGE OF TYPE 3 AND TYPE 4 COMPOSITE CYLINDER DURING FILLING

Inert Air (N2) Systems Manual

EXPERIMENTAL SUPPORT OF THE BLEED AND FEED ACCIDENT MANAGEMENT MEASURES FOR VVER-440/213 TYPE REACTORS

Liquid Lead-Bismuth Materials Test Loop

PERFORMANCE SPECIFICATION PROPELLANT, HYDROGEN

Helium Loop Karlsruhe (HELOKA) large experimental facility for the in-vessel ITER and DEMO components

Neural Nets Using Backpropagation. Chris Marriott Ryan Shirley CJ Baker Thomas Tannahill

Magnet and RF Cavity Test Stand Design. Tom Peterson, SLAC USPAS January, 2017

CFD analysis & Experimental Investigation of Shell & Tube Type Heat Exchanger with modified Slotted Baffles

Helium-Liquefaction by Cryocooler for High-Field Magnet Cooling

I.CHEM.E. SYMPOSIUM SERIES NO. 97 BUOYANCY-DRIVEN NATURAL VENTILATION OP ENCLOSED SPACES

EXPERIMENTAL STUDY ON THE HYDRODYNAMIC BEHAVIORS OF TWO CONCENTRIC CYLINDERS

2/2/2018 Control System General Description(H4DOTC) Diagnostic Trouble Code (DTC) Detecting Criteria DTC P0442 Evaporative Emission Control

EFFECTS OF LASER WINDOW DEGREDATION ON LASER POWER AND DISTRIBUTION IN LASER SINTERING. Ben Fulcher, David K. Leigh

Measurement of both gas and liquid velocity profiles for bubble-induced turbulent flow

Spot the Hazards: Review Confined Space Hazards Missed by Most Safety Professionals, and the PPE Solutions that Meet OSHA Requirements

PREDICTION OF TOTAL PRESSURE CHARACTERISTICS IN THE SETTLING CHAMBER OF A SUPERSONIC BLOWDOWN WIND TUNNEL

Development of a Miniaturized Pressure Regulation System "mprs"

Copyright by Turbomachinery Laboratory, Texas A&M University

Figure 1 Schematic of opposing air bearing concept

February 5, 2014 REQUEST FOR ADDITIONAL INFORMATION FOR THE REVIEW OF THE MODEL NO PACKAGE

Fail Operational Controls for an Independent Metering Valve

Heat Engine. Reading: Appropriate sections for first, second law of thermodynamics, and PV diagrams.

Performance Evaluation of Inverted Triangular Notch and Trapezoidal Plate Fins with Natural Convection

Risk Assessment for ITER TF Coil Manufacturing )

Lecture 1 Temporal constraints: source and characterization

EVALUATION OF WIND HAZARD OVER JEJU ISLAND

Performance Testing of a High Capacity Compressor for a 20K 20W Cryocooler

Transcription:

Transactions of the Korean Nuclear Society Autumn Meeting Yeosu, Korea, October 25-26, 2018 Development of Prediction Models for Spent Nuclear Fuel Storage Cask Monitoring Hyong Chol Kim, Sam Hee Han, Dong Jae Park

Introduction (1) SNF Dry Storage Casks Over 1500 casks installed in US Delay in establishing permanent disposal facilities Extension of licensed storage terms Issues of aging management and monitoring arise Confinement monitoring becomes important Related Studies Canister surface temperature (CST) measurements for detecting helium gas leak from canister CST as a means to detect helium leakage from a breach of a welded canister due to aging degradation 1. Hirofumi Takeda, et. al, Development of the Detecting Method of Helium Gas Leak from Canister, Nuclear Engineering and Design, Vol. 238, pp.1220-1226, 2008. 2. Jie Li and Yung Y. Liu, Thermal Modeling of a Vertical Dry Storage Cask for Used Nuclear Fuel, Nuclear Engineering and Design, Vol. 301, pp.74-88, 2016. NSE Technology 2

Introduction (2) Focus of the Present Study Feasibility of monitoring methods based on CST Experimental studies on thermo-fluidic performance of dry storage cask Artificial neural network model development for predicting: - canister internal pressure - peak cladding temperature Experimental confirm of applicability of the prediction models NSE Technology 3

Test Apparatus (1) Description of test apparatus Scaled-down with 1/3 height of reference design Single 16x16 fuel assembly Fill gas: helium Natural convection of helium in the canister Upward air flow in annular gap Temperature sensors: - fuel rod cladding - air inlet and outlet - cannister surface Pressure sensor NSE Technology 4

Test Apparatus (2) Configuration of test apparatus Temperature Measurement Positions in Fuel Assembly CST Measurement Positions on the Canister NSE Technology 5

Test Results (1) Experimental Range PCT: 300 ~ 400 Ambient air temperature: 21 ~ 34 Helium pressure: 0.35 MPa ~ 0.01 MPa Electric power: 1.60 kw, 1.72 kw Exemplary Cladding Temperature Profiles of the Fuel Rods (1.6kW, 0.155 MPa) NSE Technology 6

Test Results (2) PCT Measurement Results Cladding Temperature Variation as a Function of Helium Pressure(HT095, 1.72kW) NSE Technology 7

Height in Canister (mm) Test Results (3) CST Measurement Results 1400 1200 1000 800 600 400 0.3 MPa 0.211 MPa 0.127 MPa 0.067 MPa 0.009 MPa 200 0 50 100 150 Surface Temperature ( ) CST Variation as a Function of Helium Pressure. NSE Technology 8

Development of Neural Network Prediction Models (1) Rationales To keep the maximum fuel cladding temperature within the design limit during the extended long-term operation of dry storage casks To take precautionary actions when helium leak is suspected Description of Neural Network Models 3-layered artificial neural network using the delta rule with the backpropagation algorithm Temperature slopes derived from CSTs were augmented as functional-link inputs to improve prediction performance NSE Technology 9

Development of Neural Network Prediction Models (2) Training Results of Neural Network Models Training database for neural network models was built from 11 steady-state test points Training Results of PCT Prediction - σ = 2.0 - δ-max < 6 Training Results of Pressure Prediction - σ = 0.0035 MPa - δ-max < 0.01 MPa NSE Technology 10

Results of Monitoring Application (1) Application Test of Prediction Models Prediction models were applied to the actual test data for verification as a means of monitoring method for dry storage casks 18 days long test with internal pressure variation from around 0.35 MPa to 0.01 MPa Pressure variation presents transients caused by abrupt pressure drops and quasi-steady states between the transients Monitoring results of canister internal pressure. NSE Technology 11

Results of Monitoring Application (2) Application Test of Prediction Models The prediction results were relatively excellent for both pressure and PCT when the thermo-fluidic state becomes stabilized after transients. The monitoring model could easily alarm any transient occurrence due to rapid helium gas leak when abnormal peaks or drops are observed. Monitoring results of peak cladding temperature NSE Technology 12

Conclusions Test apparatus was constructed to investigate thermal behaviors of the vertical dry storage casks. Results of tests have shown the thermo-fluidic characteristics of dry storage casks and were used to build database. Artificial neural network prediction models were developed using the axially aligned canister surface temperatures as input parameters. The prediction results of the developed models have been found to be excellent for stabilized thermo-fluidic states. Thermo-fluidic transients caused by rapid pressure loss could be easily alarmed from anomaly indication of the prediction models. Therefore, the neural network models can be used for predicting the canister internal pressure and the PCT based on the canister surface temperatures without any pressure gauge installation and appear promising for long-term confinement monitoring of dry storage casks. NSE Technology 13

감사합니다