Refrigeration and Air Conditioning Technical leaflet

Similar documents
Capacity regulator (hot gas bypass), type TUH/TCHE/TRHE REFRIGERATION AND AIR CONDITIONING. Technical leaflet

Capacity regulator (hot gas bypass)

Thermostatic Expansion

Crankcase pressure regulator, type KVL REFRIGERATION AND AIR CONDITIONING. Technical leaflet

Modulating liquid level regulators, direct-controlled, type SV 1 and 3 REFRIGERATION AND AIR CONDITIONING. Technical leaflet

Technology issues regarding Blends of Refrigerants Buffalo Research Laboratory

Float valves Types SV 1 and SV 3

Evaporator pressure regulator Type KVP

Condensing pressure regulator, type KVR Differential pressure valve, type NRD

Evaporator pressure regulator Type KVP

D A T A S H E E T. Technical Data. Maximum Working Gauge Pressure (bar) Capillary Tube Length (m) 1.5 (5Ft) Burst Gauge Pressure (bar) 234.

CHECK VALVES APPLICATIONS

Solenoid valve type EVR for Hydrocarbons

Condensing pressure regulator, type KVR Receiver pressure regulator, type NRD

Solenoid valves, two-step on/off Type PMLX REFRIGERATION AND AIR CONDITIONING. Technical leaflet

Modulating liquid level regulators, servo-controlled PMFL / PMFH and SV

Float valves Types SV 4, SV 5 and SV 6

Liquid level regulating valves Types PMFL / PMFH and SV

2-step solenoid valve Type ICLX

Sales Office: Danfoss Expansion Valves. T*2 Range Order valve and orifice separately Range N -40 C to +10 C Without MOP

2-step solenoid valve Type ICLX

Electric expansion valves Types AKV 10, AKV 15 and AKV 20

Technical leaflet. Pressure and Temperature Regulators. January 1999 RC.4X.B1.22. Danfoss A/S

Using P-T Analysis As A Service Tool

Solenoid Valves, one - or two step, on/off ICLX

Differential pressure and flow controller (PN 16) AVPQ - return mounting, adjustable setting

Evaporating Pressure Regulating Valve Type KVQ REFRIGERATION AND AIR CONDITIONING. Technical leaflet

Official Journal of the European Union L 92/3

Water valve Type WVO. Data sheet MAKING MODERN LIVING POSSIBLE

Guida parametri EVD 200. Manuale d'uso User manual

Pressure reduction controller (PN 16, 25, 40)

Selection of ICF made easy Save even more time with ICF

CROT-6 CROT-10 CRO-4. for Compressor Overload Protection

) for different types of systems Test of contact function The correct pressure control for your system

Radiator thermostats type RA2000, valve bodies type RA-FN (series D) and RA-G

Installation and Operation 370ESP (Electric Single-Point Purger) & 370ESPR (Retrofit Purger)

Differential pressure control and flow limiter AVPB/AVPB-F, PN 16

A28 Series Two-Stage Temperature Controls with NEMA 1 Enclosure

Gas powered stop valves, type GPLX REFRIGERATION AND AIR CONDITIONING. Technical leaflet

Job Sheet 1. Geothermal Energy

V46 Series 2-Way Pressure-Actuated Water-Regulating Valves With Union Fittings

Capacities Valve Station, type ICF 15, 20, 25

Test on a Twin-Screw Compressor

Self-operated Regulators Accessories Differential Pressure and Flow Regulators

Radiator thermostats type RA2000, valve bodies type RA-FN (series D) and RA-G

AVPQ/AVPQ-F, PN 16. Application

Exercise 4-2. Centrifugal Pumps EXERCISE OBJECTIVE DISCUSSION OUTLINE DISCUSSION. Pumps

Energy savings in commercial refrigeration equipment: High Pressure control implementation

V48 Series 3-Way Pressure-Actuated Water-Regulating Valves With Union Fittings

80% Less installation time with just two welds for fast and efficient installation.

Soft-optimization test of R-410A alternative refrigerant R-32 in a split condensing unit - Phase II

CO 2 radial piston compressor (transcritical)

Pilot HON 625. Entwurf. Product information. serving the gas industry worldwide

EXAM # 2. First Name Last Name CIRCLE YOUR LECTURE BELOW: INSTRUCTIONS

Two-Stage Linear Compressor with Economizer Cycle Where Piston(s) Stroke(s) are Varied to Optimize Energy Efficiency

80% Less installation time with just two welds for fast and efficient installation.

RA-N radiator valves with integrated presetting and self-sealing tailpiece

Pilot valves for pilot operated servo valves

Pressure switch and Thermostat CAS

EU minimum requirements. Training and certification for personnel and companies

V146 Series 2-Way Pressure-Actuated Water-Regulating Valves

Pressure switch SANHUA PS01/50/15 SERIES. ideas worldwide STANDARD

Model 26.5 WEAU242AA WEAU244BA 29.0 WEAU242BA 29.0 WEAU304AA 33.0 WEAU302AA WEAU304BA 33.0 WEAU302BA 33.

An Efficient Vortex Tube With Max C.O.P

STAD-C. Balancing valves DN 15-50

Presetting Valve Type RA-N with Flange Connection

A/C SYSTEM GENERAL DIAGNOSTIC PROCEDURES

VRF. Technical Data Book. DVM S ECO for Europe (R410A, 50Hz, HP) Model : AM***KXMDGH/EU

STAD-C. Balancing valve ENGINEERING ADVANTAGE

Dual position solenoid valve Type ICSH 25-80

Contents. Introduction Part 1 General Information Part 2 General Instruction Part 3 Outdoor Units Part 4 Installation...

MAKING MODERN LIVING POSSIBLE. Pilot operated internal safety valves type POV REFRIGERATION AND AIR CONDITIONING DIVISION.

Differential pressure controller (PN 25) AVP - return and flow mounting, adjustable setting

Series V48. 3-Way Pressure Actuated Modulating Valves. Product Bulletin. Features. Pressure balanced design. Free movement of all parts

Effect of Coiled Capillary Tube Pitch on Vapour Compression Refrigeration System Performance

Supersedes: RP1(495) Form RP1 (1102)

CFD Flow Analysis of a Refrigerant inside Adiabatic Capillary Tube

Type 4708 Supply Pressure Regulator

Series V47 Temperature Actuated Modulating Valves

AE R8 December 2004 Reformatted November Copelametic Two-Stage Compressors Application and Service Instructions

Differential pressure controller with flow limitation (PN 16, 25, 40) AFPB / VFQ 2(1) AFPB-F / VFQ 2(1)

Semi-Hermetic compact screw compressors

AVP-F. p setting range (bar) Code No. 003H6200

System Conditions Harmful to Compressors Their Diagnosis and Prevention

Technical Data Sheet T 2025

SERVICE PARTS MANUAL ICE SERIES CUBERS MODEL - ICE0250A5-T5-W5, ICE0400A4-T4-W4 MODEL - ICE0500A4-T4-W4-R5, ICE0606A4-T4-W4-R5 Includes 50Hz.

Single- or Two-Stage Compression

Reliable System Performance PM valves

Shut-off Liquid level and regulating valves for for Industrial Refrigeration

differential pressure regulating valve - threaded

Regulating valves Type REG 6-65 Type REG-SS REFRIGERATION AND AIR CONDITIONING. Technical leaflet

A/C SYSTEM DIAGNOSIS

How to Select High Pressure and Gas Bypass

Overflow valves Type OFV Type OFV-SS REFRIGERATION AND AIR CONDITIONING. Technical leaflet

Data sheet. Pressure switches and thermostats Type KPS 10/2003 DKACT.PD.P10.E B0782

Pressure switch and Thermostat Type KPS

Pressure switch and Thermostat KPS

P14 Series Pressure Actuated Mechanical Sequencer

Pressure switches and thermostats, type KPS

Overflow valves Type OFV REFRIGERATION AND AIR CONDITIONING. Technical leaflet

Transcription:

Refrigeration and Air Conditioning Technical leaflet

Technical leaflet Injection valve type 2 Introduction Danfoss has developed a injection valve type 2 for desuperheating in 2-stage refrigeration systems operating on R 22 where the hot gas temperature and the intermediate pressure are the controlling variables. Application In principle there are two different ways in which to setup 2-stage refrigeration systems as far as temperature signal to the liquid injection valve is concerned. Application examples Example 1 2-stage refrigeration system built up with a combined LP/HP compressor. In this case the discharge gas temperature on the HP side is used as temperature signal and the intermediate pressure as pressure signal to the injection valve. In this example a 2 injection valve is used, see fig. Fig. 1 LP: Low pressure HP: High pressure PI: intermediate pressure 2 RD.1A.A2.02 Danfoss 2/98

Technical leaflet Injection valve type 2 Application examples continued Example 2 2-stage refrigeration system with 2 separate refrigerating compressors in series. In this set up a solution with injection valve type 2 can be used, because the discharge gas temperature on the HP side can be used as temperature signal and the intermediate pressure as pressure signal to the injection valve, see fig. 2. Fig. 2 LP: Low pressure compressor HP: High pressure compressor PI: Intermediate pressure Example 3 Same setup as in example 2 with 2 separate refrigerating compressors in series. As in this setup there is an accessible control signal where there is correspondence between pressure and temperature, regulation of the strongly superheated condition of the refrigerant can be undertaken by a traditional thermostatic expansion valve e.g. Danfoss type TX 2 for R 22 refrigeration systems, see fig. 3. Fig. 3 LP: Low pressure compressor HP: High pressure compressor PI: Intermediate pressure Danfoss 2/98 RD.1A.A2.02 3

Technical leaflet Injection valve type 2 Operation P bulb P spring PI Fig. 4 The valve function is controlled by the intermediate pressure (PI) acting under the diaphragm and the bulb pressure derived from the discharge gas temperature across the diaphragm (fig. 4). 4 RD.1A.A2.02 Danfoss 2/98

Technical leaflet Injection valve type 2 The intermediate pressure (PI), setting spring and bulb temperature form a working range which, expressed in a co-ordinate system, makes up a working area, see fig. 5. Fig. 5 Valid for code no. 068-3249 only Fig. 5 Valid for code no. 068-3258 only Within the limits of this area, the working point required is found (PI/t bulb ). The location of the working point depends on the spring force set and in addition to that dependent on the proportional band (the superheat) and the valve capacity (size of orifice). Therefore, the sizing is decisive for a satisfactory result. Danfoss 2/98 RD.1A.A2.02 5

Technical leaflet Injection valve type 2 Sizing To size 2 the refrigerating capacity required to remove the superheat at the intermediate stage must be known as well as the required discharge gas temperature on the discharge side. Besides this the pressure drop p across the injection valve must be determined as the Example: difference between the condensing pressure and the pressure at the intermediate stage. With the values for the required capacity, the evaporating temperature t 0 (PI) of the intermediate stage and the pressure drop across 2, the correct orifice size can be determined. Required refrigerating capacity Q= 5 kw Evaporating temperature at intermediate state t 0 = -25 C drop across 2 p= Discharge gas temperature (HP)= 110 C Evaporating temperature -25 C 2 4 6 8 10 0.69 0.83 0.94 02 08 15 21 51 71 85 96 2.04 2.09 2.11 66 2.13 2.42 2.62 2.77 2.87 2.94 2.97 2.98 3.82 4.33 4.69 4.96 5.15 5.27 5.33 2-2 04 4.36 5.59 6.35 6.89 7.30 7.60 7.80 7.91 2-5 05 5.55 7.10 8.06 8.74 9.26 9.64 9.89 10.02 6.80 8.68 9.84 10.67 130 177.08.25 2 with orifice 03 fits that example as the values in the capacity tables are shown with a proportional band of 6 K. Capacity in kw Evaporating temperature (PI) -10 C 2 4 6 8 10 0.79 0.96 1 2 2 3 3 3 6 2. 0 2. 3 2. 5 2. 6 2. 7 2. 8 2. 8 2. 2 2. 9 3. 3 3. 6 3. 8 4. 0 4. 1 4. 1 3. 9 5. 1 5. 9 6. 4 6. 8 7, 1 7. 3 7. 3 2-2 04 5. 8 7. 6 8. 7 9. 5 10. 1 10. 5 10. 8 10. 9 2-5 05 7. 4 9. 6 1 0. 0. 8 13. 3 13. 6 13. 8 9. 1 1 8 13. 5. 7 15. 6. 2. 6. 8 Evaporating temperature (PI) -20 C 4 6 8 10 0.88 0 1 1 2 2 2 17 9 2. 0 2. 2 2. 3 2. 3 2. 3 2. 4 2. 7 2. 9 3. 1 3. 2 3. 3 3. 3 4. 2 4. 8 5. 2 5. 5 5. 8 5. 9 6. 0 2-2 04 6. 2 7. 1 7. 7 8. 2 8. 5 8. 7 8. 8 2-5 05 7. 9 9. 0 9. 8 10. 3 10. 8 1 0 1 2 9. 6 1 0 1 9. 6 13. 1 13. 5 13. 7 6 RD.1A.A2.02 Danfoss 2/98

Technical leaflet Injection valve type 2 Evaporating temperature (PI) -25 C 2 4 6 8 10 0.69 0.83 0.94 02 08 15 21 51 71 85 96 2.04 2.09 2.11 66 2.13 2.42 2.62 2.77 2.87 2.94 2.97 2.98 3.82 4.33 4.69 4.96 5.15 5.27 5.33 2-2 04 4.36 5.59 6.35 6.89 7.30 7.60 7.80 7.91 2-5 05 5.55 7.10 8.06 8.74 9.26 9.64 9.89 10.02 6.80 8.68 9.84 10.67 130 177.08.25 Evaporating temperature (PI) -30 C 4 6 8 10 0.79 0.90 0.96 0 1 1 1 4 5 7 8 8 9 9 9 2. 2 2. 7 2. 5 2. 6 2. 6 2. 7 3. 4 3. 9 4. 2 4. 4 4. 6 4. 7 4. 8 2-2 04 5. 0 5. 7 6. 2 6. 5 6. 8 7. 0 7. 1 2-5 05 6. 4 7. 2 7. 8 8. 3 8. 6 8. 8 9. 0 7. 8 8. 8 9. 6 10. 1 10. 5 10. 8 1 0 Evaporating temperature (PI) -40 C 2 4 6 8 10 0.60 0.71 0.80 0.86 0.92 0.95 0.98 0.99 0.90 11 25 35 43 49 53 55 23 55 74 88 97 2.05 2.09 2. 2.20 2.78 3. 3.36 3.54 3.68 3.77 3.81 2-2 04 3.20 4.04 4.56 4.93 5.21 5.43 5.58 5.67 2-5 05 4.07 5. 5.79 6.26 6.62 6.90 7.09 7.20 4.98 6.28 7.07 7.65 8.09 8.44 8.68 8.82 Danfoss 2/98 RD.1A.A2.02 7

Technical leaflet Injection valve type 2 Setting 2 cannot be set until the refrigerant system is started up. Setting after start-up is carried out when the discharge gas temperature has been recorded and the intermediate pressure is known or measured. By means of the diagram, fig. 5, the actual working point is found. From the location of the working point in the diagram, fig. 5, it should be decided whether to increase or decrease the spring force. Alteration of the spring from slack to tight setting corresponds to 6 revolutions of the 2 setting screw. Technical data Perm. working pressure PBIMWP: 28 Max. test pressure: 36 Capillary tube: 5 m. Ordering valve Type Connections [in.] Temp. range Weight KG Code range (pi) -2 3 /8 1 /2 SAE flare +100 +130 C 0-2 0.3 068-3249 -2 3 /8 1 /2 SAE flare +100 +130 C 1-5 0.3 068-3258 -2 3 /8 SAE flare +100 +130 C 0-2 0.3 068-3342 1 /2 solder -2 3 /8 SAE flare +100 +130 C 1-5 0.3 068-3343 1 /2 solder -2 3 /8 SAE flare +80 +110 C 1-5 0.3 068-3344 1 /2 solder -2 3 /8 1 /2 SAE flare +80 +110 C 1-5 0.3 068-3360 Ordering accessories assembly no. Code no. TE 2 00 068-2003 01 068-2010 02 068-2015 03 068-2006 04 068-2007 05 068-2008 06 068-2009 Flare nuts Symbol Connection for copper tubing with outside cam. Reducer for copper tubing with outside diam. Code no. i n. m m. i n. mm. 1/4 6 011L01 3/8 10 011L35 1/2 011L03 3/8 10 1/ 4 6 011L07 8 RD.1A.A2.02 Danfoss A/S (AC-SP, JP) 2.98