User Manual V14.1 IP68 LED FLEX NEON PLEASE READ THESE INSTRUCTIONS CAREFULLY BEFORE INSTALLATION LEAVE A COPY FOR THE END USER/MAINTENANCE ENGINEER FOR FUTURE REFERENCE 1/11
PRODUCT SPECIFICATION 1. Operating voltage: DC 24V 2. Dimension: 11.5mm (Base)* 15.5mm(Optic)*29mm(Height) 3. Available Colors: : Red, Yellow, Orange, Green, Blue, White, Warm White Multi : RGB 4. LED quantity & Power consumption: : 120pcs SMD 3528 (7.2W/m ) Multi : 60pcs SMD5050 (12W/m ) 5. Max. running length: 10 m t rs (Single Feed) or 20 m t rs (Double Feed) 6. Min. cutting length :100 mm(10leds). : 100mm(12LEDs). Multi : 167mm(10LEDs) 7. Min. bending diameter: 12cm (Do not twist this light fixture - See caution diagrams!) 8. Ambient operating temperature : -30 ~45. 9. Protection rating: IP68. (NOTE: All connectors must be assembled properly to achieve IP68 rating.) 10. Certificate: CE and ROHS compliant SAFTY PRECAUTIONS -Do not over extend the min. & max. bend radius. See Illustrations for bending. -Although products do not generate a great amount of heat, it is recommended that you do not cover or conceal it. -Do not puncture, cut, shorten or splice LED neon outside of the designated cutting marks. -Do not route LED flex neon through walls, doors, windows, or building structures. -Do not roll out LED flex neon on rough surfaces and over sharp corners. This will scratch the PVC optic. -Do not use the product if outer PVC jacket is damaged, loose connections, or if the wire is visible without insulation. -Do not secure the product with staples, nails, or like means that might damage the insulation or PVC material. -Do not installed LED flex neon on/in places where it is subject to continuous flexing. -Do not operate/run LED flex neon in temperatures exceeding 45C or 115F. -Do not operate LED flex neon over the specified voltage or LED life degradation will be greatly increased. -Do not leave any part of the LED flex neon unsecured. Movement over time from weather can cause damage from continuous movement. -ALL LED neon IP68 RATED CONNECTORS MUST BE ASSEMBLED PROPERLY TO OBTAIN RATING. -Do not reverse polarity when connecting from both ends. This will damage the internal PCB board. Always test connections with your multi-meter. -Do not energize LED flex neon in the reel package. -LED Flex Neon can be cut only where marked. Look for Indent marking or Dotted Line or Scissor Mark. CUTTING OUTSIDE OF THE SPECIFIED MARK WILL DAMAGE THE LIGHT. DO NOT CUT WHILE FIXTURE IS ENERGIZED. 2/11
ACCESSORIES(sold separately) IP 68 Accessories Kit A. 10 Meter to 20 Meter Accessories Kit with IP68 Power Connects. 1. Left Power Feed 1pc 2. Right Power Feed 1pc 3. Rubber gasket 1pc 4. Aluminum Mounting Piece 1pc 5. Stainless Anti-skid Plate 1pc 6. Stainless Steel Screws 2pcs B. 10 Meter or Less Accessories Kit with IP68 1. Front Connector Accessories Kit 1pc 2. Left Power Feed 1pc 3. Rubber Gasket 1pc 4. Aluminum Mounting Piece 1pc 5. Stainless Anti-skidding Clip 1pc 6. Stainless Steel Screws 2pcs C. End Cap Accessories Kit 1. The Tail Plug 1pc 2. Aluminum Mounting Piece 1pc 3. Rubber Gasket 1pc 4. Stainless Anti-skidding Clip 1pc 5. Stainless Steel Screws 2pcs WARRANTY 1. The product is warranted against manufacturer defect for a period of 2 years from the date of purchase. 2. The warranty period is based on typical 8hrs/day operation under an application environment temperature -30 ~45 3. The guarantee is invalid in case of improper use and incorrect installation. 3/11
Minimum bending diameter: 120mm User Manual Bending Direction 4/11
Suspending LED flex neon as the picture illustrates is not permitted. User Manual Attention: How to use 2pin Cable Connector for 5/11
IP68: Connection Diagrams A. Single end connection for Max. length 10 m B. Connecting both ends for 10m to max. length of 20m (NOT applicable for Multic and Dynamic) 6/11
IP 68 Front Connector Installation 7/11
IP 68 End Cap Installations 8/11
Unit cutting guide Installation 9/11
Installation Guide 1. Fixing Aluminum U-channel by screw 2. Install the light into the aluminum U-channel and level ANSI STANDARD Nominal CCT Categories Remark: 1. Six of the nominal CCTs correspond to those in the fluorescent lamp specification [2]:2700K,3000K(Warm White),3500K(White),4100K(Cool White),5000K and 6500K(Daylight),respectively. 2. T is chosen to be at 100K steps (2800,2900,,6400K) excluding, hose eight nominal CCTs listed in Table 1. 3. T is given by T = 0.0000108 T2+0.0262 T+8. 4. Duv is given by Duv=57700 (1/T)2-44.6 (1/T)+0.0085 10/11
On Site Installation User Manual LED flex neon has to be heated up to room-temperature before assembly. Depending on storage location, flexibility of LED flex neon can be highly reduced when temperatures are too low. Warming up to room-temperature makes LED flex neon flexible for proper assembly. Best temperature for the assembly is between +18 C and +35 C (64 F to 95 F). For assembly of LED flex neon longer than 2m carefully handling with min. 2 employees is absolutely necessary. The electrical circuit could be damaged if bending radius is too small. Stainless steel core and resin can not avoid any damage by inadequate handling. RMIN=12CM The installation surface must be dry and clean. Condensing moisture on the surface has to be avoided. Surface must be free of dust, grease, oil or separating agents. For cleaning use clean cloth and material-compliant detergents like Isopropanol. Pressure to insert the LED flex neon should be between 10-15 N/cm². 11/11