User manual CF8-D/W-IN

Similar documents
CF8-W-Disp-CO. User manual. CO 2 / CO sensor with built-in general purpose controller

User Manual. asense VAV. CO 2 / temperature sensor with built-in general purpose controller

User Manual. asense miii. / CO sensor with built-in general purpose controller

Datasheet: K-30 ASCII Sensor

CDS-2000 CO 2 Sensor Verification, Calibration, and Troubleshooting Bulletin

Sensoric 4-20 ma Transmitter Board Operation Manual

Table of Contents. Sensor Calibration and Troubleshooting CDS4000 CO 2. Introduction 1. Handling Information. Calibration 2.

Hot extractive multi-channel gas analyser for continuous process and emissions monitoring.

Hot extractive multi-channel gas analyser for continuous process and emissions monitoring.

SPECIFICATIONS APCEPH1

Manual Weighingblock VB2 series and Uniscale

DeeterFlow Automatic Liquid Dispenser

CO, NO, NO 2, NO x, SO 2, CH 4, HCl, CO 2 & H ² O. Extractive low cost, low maintenance devices for continuous process and emissions monitoring.

Using the UltraRAE. Firmware 2.35

D10S/D20S Wall/Post Mount Inflator Quick Start Manual

USER MANUAL OPERATION AND THE USE OF A CAR WITH. Diego G3 / NEVO SEQUENTIAL GAS INJECTION SYSTEM

Instruction and Maintenance Manual

User Manual. µ-gard MD Electrochemical Carbon Monoxide Transmitter Serial No. MD April, 2011

ACV-10 Automatic Control Valve

Instruction and Maintenance Manual

User Manual. PolyGard DT V4. Electrochemical Carbon Monoxide Transmitter Serial No. DT December, 2008

OXY Integral. INTERCON ENTERPRISES INC Tel: Fax: Internet:

SECTION 2 SMART PAYOUT MANUAL SET FIELD SERVICE MANUAL

HBLT-A1 LIQUID LEVEL SENSOR

Do Not Print This Page.

LEVIFLOW INTEGRATED FLOWMETER LFIF USER MANUAL

SR-242 USER S GUIDE. Table of Contents

Touch Screen Guide. OG-1500 and OG Part # T011

OPERATOR s MANUAL AHCON PCI 3000

OPTIMA 7 - BIOGAS Calibrating the gas sensors SENSOR ADJUSTMENT. Diamond Scientific 625 Peachtree St., Cocoa, Florida /Tel:

Hydro-Control V User Guide

Using Modbus Protocol with the ALTUS Net Oil Computer. Instruction Manual

Manual Oxygen Analyzer A4009T

User Manual. Pro CO LP Alarm. Carbon Monoxide Analyzer and Low Pressure Monitor with Alarm REV: 03.19

BI-680 Online Dissolved Oxygen Controller Instruction Manual

ISM-3 User Manual PBI D 04/2013

Napa Technology Trouble Shooting. For Premier & Premier PLUS Models

USER'S GUIDE. Vaisala CARBOCAP Carbon Dioxide Calibrator for the GMP220 series probes GM K220 U421EN-1.1

Atlas 6TM. Indoor Air Quality Monitor Instruction Manual. Measures CO 2, Temperature and Humidity DISTRIBUTED BY

Fixed Ozone Monitor User Manual December, Automatikprodukter

Operation Manual. Pro CO. Carbon Monoxide Analyzer. Rev

CCT-7320/ROC-2313 Reverse Osmosis Controller

Application Notes. SLP85xD Load Cells

Transmitter CS 21 Operation Manual

MEC OEM. User Manual. Commercial in Confidence

TEL/jlRE" Introduction. Display Features and Modes. Startup Procedure. Power-Up Procedure. Adjustment Modes

Burner Management System DEMO Operating instructions

Heavy Duty Dissolved Oxygen Meter

AMS 6915 Board mount pressure sensor with digital output (I²C)

A4s Operation Manual

RAM 4021 Operation Manual

CTS-M1816 CARBON MONOXIDE TRANSMITTER/SENSOR

MEGAS 2.0. Gas analysis with direct C-Level Calculation and Bus-Connection. Data sheet

theben Continuous valve actuator CHEOPS drive CHEOPS drive As of: Jul-11 (Subject to change without notice) Page 1 of 41

Continuous Gas Analysis In situ laser gas analyzers TÜV and MCERTS add-on for LDS 6 operating instructions Compact Operating Instructions

Stand-Alone Bubble Detection System

DF-310E PROCESS ANALYSERS APPLICATIONS FEATURES

Technical Data Sheet MF010-O-LC

Plasma. Argon Production Helium Liquefaction Truck Loading Pure Gas Bottling

D10 Inflator Quick Start Manual

User Manual. Heads-Up Display (HUD) DiveCAN. Mechanical Button Version

BUBBLER CONTROL SYSTEM

HUMOR 20. High Accuracy Humidity Calibrator. Water T, p1 HUMOR 20 V1.0

2600T Series Pressure Transmitters Plugged Impulse Line Detection Diagnostic. Pressure Measurement Engineered solutions for all applications

CALIBRATION KIT. Instruction Manual

RAM Operation Manual

In Response to a Planned Power Outage: PPMS EverCool II Shut Down and Re-start Procedure

RAM 4021-DPX Operation Manual

TECH TIPS TZ34/20 & TZ50/30. Service Call: Machine will not automatically level. Tools Needed: Multi Meter Jumper wire 7/16 Combination wrench.

Membrane covered optical CO 2 sensor

AUTOMATIC TIRE INFLATOR # MW-60, MW-60-4WAY & MW-64HP

UsER manual for Watersens ph -REDOX

Instruction Manual. Biogas Analyzer InCa Bio 04

APA software instruction manual

GasSense NDIR User Manual

Operating Instructions Part No

NEULOG OXYGEN LOGGER SENSOR GUIDE

Alphasense 4-20 ma transmitters offer convenience and easy maintenance for toxic sensors:

FX134, FX1234, FX3030 Problem and Solutions

Built-in Purge Control Functions

RAM Operation Manual. Worldwide Manufacturer of Gas Detection Solutions

G100 RANGE G100, G110, AND G150 OPERATING MANUAL

T i m i n g S y s t e m s. RACEAMERICA, Inc. P.O. Box 3469 Santa Clara, CA (408)

Exercise 2-2. Second-Order Interacting Processes EXERCISE OBJECTIVE DISCUSSION OUTLINE. The actual setup DISCUSSION

Instruction Manual. BZ7002 Calibration Software BE

DF-550E PROCESS ANALYSERS APPLICATIONS FEATURES

COMPRESSOR PACK SUCTION CONTROLLER TYPE: LP41x

RAM 4021-PR. Operation Manual. Worldwide Manufacturer of Gas Detection Solutions

Overview. The user must follow the instructions below.

GASGUARD VENT LINE3 Ammonia Sensor OPERATING & INSTALLATION MANUAL

Calibration Gas Instrument INSTRUCTION MANUAL. Release I. Advanced Calibration Designs, Inc.

STARLOG. Capacitive Water Depth Probe

Because every life has a purpose. MSA Z GARD S Sensor Calibration Procedure

D12 Inflator Quick Start Manual

Domino DUEMMEGI. Domino. Communication Interface DFTS User s Manual. Release September 2007

Operating instructions Safety Rope Emergency Stop Switches ZB0052 / ZB0053 ZB0072 / ZB0073

Nuclear Associates

Transmitter CS 21 Operation Manual

Gas Analyzer for TC Sensors (CO2, H2, N2) Series 62101, 64101, Operating Manual

Columbus Instruments

Transcription:

User manual CF8-D/W-IN General The sensor CF8-D/W-IN is used to measure the carbon dioxide concentration inside incubators. All functions can be modified from a PC with the communication cable. UMA 48 (6)

Functional description This part describes the function of the configuration of CF8-D/W-IN. Please note that the two outputs may completely or partly have other functions. These functions may be reprogrammed after the installation. To be sure that every unit is correctly programmed, in accordance to the actual application, a check by a PC and the standard UIP software (version 4.0 or higher) is necessary. OUT and OUT2 are used for the measuring signal of carbon dioxide concentration. OUT = measuring signal of carbon dioxide concentration OUT2 = measuring signal of carbon dioxide concentration Terminal Standard configuration Standard settings * Standard function OUT 4-20mA 0-3 % CO 2 Measuring signal OUT2 0-5VDC 0-2 % CO 2 Measuring signal Table I. Default configuration of CF8-D/W-IN OUT OUT2 Current Voltage Current Voltage Connection in position Current provides 4-20mA output range for OUT. See note Connection in position Voltage provides 2-0VDC output range for OUT. See note Connection in position Current provides 0-0mA output range for OUT2. See note Connection in position Voltage provides 0-5VDC output range for OUT2 See note. Table II. Configuration jumpers for CF8-D/W-IN Note : During start up the unit may deliver up to 0 VDC or 20 ma for up to half a second. UMA 48 2 (6)

Functional test of CF8-D/W-IN The unit has two LED s -one yellow and one red. These LED s indicate the status of the controller. Yellow LED - Call for maintenance is lit, if an error flag is set or the measurement is out of range. The yellow LED flashes in series during Automatic Zero Point Calibration. Red LED - Relay active is lit for eight minutes when a zero point calibration has been executed. PLEASE NOTE! The sensor accuracy is defined at continuous operation. Self diagnostics The system contains complete self diagnostic procedures. A full system test is executed automatically every time the power is turned on. For CF8-D/W-IN the internal voltage regulators and outputs are checked. In addition, constantly during operation, the sensor probes are checked against failure by checking the valid dynamic measurement ranges. These different system checks return error bytes to the system RAM. If any error is detected, the yellow LED will be lit until the error has vanished and the error flag is reset. Warm up and Out of Range are the only bits that are reset automatically after return to normal state. All other error bits have to be reset manually after return to normal state by power off and restart. Descriptions of the different codes are listed below. Bit # Error code Error description 0 N/A Fatal Error Yellow LED continuously flashes. Push buttons are not operating. 2 Reserved 2 4 Algorithm Error. Indicate wrong EEPROM configuration. 3 8 Output Error Detected errors during output signals calculation and generation. 4 6 Self Diagnostic Error. May indicate the need of zero calibration or sensor replacement. 5 32 Out Of Range Error Accompanies most of other errors. Can also indicate overload or failures of sensors and inputs. Resets automatically after source of error disappearance. 6 64 Memory Error Non fatal error during memory operations. 7 28 Warm Up state Is always set after power up or power failure. Resets after restart sequence. Suggested action Try to restart sensor by power OFF/ON. Contact local distributor Try to restart sensor by power OFF/ON. Check detailed settings and configuration with UIP software version 4.0 and higher. Contact local distributor Check connections and loads of outputs. Check detailed status of outputs with UIP software version 4.0 and higher. Check detailed self diagnostic status with UIP software version 4.0 and higher. Contact local distributor Try sensor in fresh air. Check detailed status of measurements with UIP software version 4.0 and higher. See Note! Check detailed settings and configuration with UIP software version 4.0 and higher. If it doesn t disappear in half a minute, check power stability. Note. Any probe is out of range. Occurs, for instance, during over exposure of CO2 sensor, in which case the error code will automatically reset when the measurement values return to normal. Could also indicate the need of zero point calibration. Remark: If several errors are detected at the same time the different error code numbers will be added together into one single error code! UMA 48 3 (6)

Automatic Zero Point Calibration The CF8-D/W-IN sensors have a function for easy automatic zero point calibration. The calibration should be done after installation and at least once every year. The calibration can be done on site. It is only necessary to connect the zero gas without any further action required from the operator, but to check the verification signal offered from the system.. Unscrew one of the filters from the sensor housing and replace it with a hose nipple. 2. Connect the zero gas to the nipple. The sensor automatically enters phase of the calibration procedure when the CO 2 concentration drops sharply. See figure 2. Do not remove the zero gas during calibration. 3. When the calibration starts the yellow LED starts to flash. The sensor continues the procedure until the readings of the sensor are stable enough and are below the limit of Automatic Zero Point Calibration. If the conditions are not good enough for calibration within eight minutes the sensor returns to normal measuring operation without calibration. 4. When the calibration is successfully executed the yellow LED flashes four times, pauses and flashes another four times for an eight minutes acknowledgement period, phase 2. During the acknowledgement period the relay is closed and the red LED is lit. 5. Remove the zero gas during the acknowledgement period. The sensor returns to normal measuring mode as soon as the calibration is ready. The yellow LED continues flashing, the red LED is lit and the relay is closed independent of gas removal. The zero gas can be generated by passing air through the chemical absorber in the service bag F0005 or by using nitrogen in a gas bottle. Not more than three minutes shall pass before the yellow LED starts to flash. If the yellow LED does not start to flash the zero gas is not good enough or the sensor is not stable enough. Wait ten minutes before another attempt to calibrate the sensor. If the sensor does not enter phase even if the conditions are good push the push button on the PCB until the red LED is lit to force a manual zero point calibration. Push the push button for at least ten seconds. UMA 48 4 (6)

800 700 Normal measurement Phase Check calibration conditions Phase 2 Acknowledgement period ppm CO2 600 500 400 300 Zero gas Yellow LED flashes Automatic Zero Point Calibration is reached 200 00 Calibration is executed The yellow LED flashes four times The red LED is lit The relay is closed 0 0 50 00 50 200 250 300 350 Time seconds Figure 2. An example of Automatic Zero Point Calibration The Automatic Zero Point Calibration should be executed after installation and at least once a year. Trouble shooting The yellow LED does not start to flash. The sensor does not enter calibration mode within three minutes.. The absorber of the zero gas bag is not fresh. Remove the old absorber and refill the bottle with fresh. The absorber is corrosive! Be careful and wear eye protection goggles. 2. The flow of the zero gas is too small or air is leaking into the sensor. The gas flow must be about 0,5 l/min. 3. Push the push button on the PCB for ten seconds (until the red LED is lit) to force manual zero point calibration. Please check the gas before pushing the push button since the calibration is executed even if the gas is not good enough. Contact the dealer if the sensor still does not enter the calibration mode. UMA 48 5 (6)

This product is in accordance with the EMC Directive 89/336/EEC and the Low Voltage Directive 73/23/EEC including amendments by the CE-marking Directive 93/68/EEC The product fulfils the following demands: EN5008-, EN550(B) EN50082-2, EN6000-4-2,-3,-4,-5, Level3 UMA 48 6 (6)