LFE OEM TCD - Thermal Conductivity Detector

Similar documents
FTC130 Transmitter. Operating Manual

ABB MEASUREMENT & ANALYTICS DATA SHEET. Advance Optima AO2000 Series Continuous gas analyzers

Flow metering in gases Introduction to COMBIMASS family

ABB MEASUREMENT & ANALYTICS DATA SHEET. Advance Optima AO2000 Series Continuous gas analyzers

Advance Optima AO2000 Series Continuous gas analyzers Models AO2020, AO2040. Measurement made easy. Modular continuous gas analyzers

Analyze IT EL6010 Gas Analyzers in Category 2G

Advance Optima AO2000 Series Continuous gas analyzers Models AO2020, AO2040. Measurement made easy. Modular continuous gas analyzers

EuroFID Total Hydrocarbon Analyzer. Precise Determination of Total Hydrocarbons in Air for Corrosive as well as Condensing Gases

ABB MEASUREMENT & ANALYTICS DATA SHEET. EasyLine EL3000 Series Continuous gas analyzers

Plasma. Argon Production Helium Liquefaction Truck Loading Pure Gas Bottling

Gas Analysis Isn t Exactly Your Only Priority? Luckily For You, It s Ours. SIPROCESS GA700 effortless gas analytics from Siemens. siemens.

EasyLine Continuous Gas Analyzers. So smart, they re simple

EasyLine EL3000 Series Continuous Gas Analyzers Models EL3020, EL3040

Precision pressure sensor Basic version Model CPT6020

Series 6517 Katharometers. The ideal equipment for Process Monitoring and Control. Robust no moving parts. Designed for continuous industrial use

Continuous Gas Analyzers, extractive

Precision level sensing with low-pressure module MS

DF-310E PROCESS ANALYSERS APPLICATIONS FEATURES

ABB MEASUREMENT & ANALYTICS. Continuous gas analyzers EL3060 The specialists for hazardous areas

Supplementary Operator s Manual 42/24-14 EN Rev. 3

Data Sheet 10/ EN July 2007

Application Note AN-107

The HumiSys. RH Generator. Operation. Applications. Designed, built, and supported by InstruQuest Inc.

Instructions for Installation, Start-Up and Operation 41/ EN Rev. 2

M iniature Amplified Pressure Sensors

Features. Main Voltage: Vdc. Input Control Signal: 0-5 Vdc or 4-20 madc (Sourcing) Monitor Output Voltage: 0-5 Vdc or 4-20 madc (Sourcing)

Gas density monitor With integrated transmitter Model GDM-100-TI

MMS Mercury Monitoring System for Natural Gas

ATEX VACUUM PUMPS AND GAUGES CHEMICALLY RESISTANT, OIL-FREE AND SAFE

ABB MEASUREMENT & ANALYTICS. Continuous gas analyzers EL3060 The specialists for hazardous areas

29th Monitoring Research Review: Ground-Based Nuclear Explosion Monitoring Technologies

Pressure Measurement Single-range transmitters for general applications

XMO2. Panametrics Smart Oxygen Analyzer. Applications. Features. bhge.com. An oxygen transmitter for use in:

Brooks TMF-Zone 1 Models 5816-Ex/5864-Ex

Instruction and Maintenance Manual

1 Overview. Continuous Gas Analyzers, extractive CALOMAT 6. 1/148 Siemens AP US Edition. General information

TEK-SUB 4800B. Submersible Level Transmitter. Flow Level Temperature Pressure Valves Analyzers Accessories TekValSys LEVEL

EASIDEW TRANSMITTER with Current Source Output

SITRANS P measuring instruments for pressure

2 Overview. SITRANS P measuring instruments for pressure. Transmitters for gage and absolute pressure. Z series for gage pressure

better measurement Simply a question of SCHMIDT Flow Sensor SS The cost-effective alternative in pressurised systems up to 10 bars.

METHOD 25A - DETERMINATION OF TOTAL GASEOUS ORGANIC CONCENTRATION USING A FLAME IONIZATION ANALYZER

Oxygen & Binary Gas Measurement and Analysis

Liquid level instruments BM 24 /BM 51

UT 3000 Mercury Ultratracer

Continuous Gas Analysis In situ laser gas analyzers TÜV and MCERTS add-on for LDS 6 operating instructions Compact Operating Instructions

Electrochemical Sensor

Analogue and Digital Mass Flow Meters and Controllers for Gases MASS-STREAM

Advance Optima -- High Performance Measurement Technology Oxygen Analyzer Module Magnos 16/17

AMS 6916 Board mount pressure sensor with ratiometric analog output

Laser Gas Analyzer LG2000. The Laser Technologies

Micro Motion 3098 Gas Specific Gravity Meter

High-performance submersible pressure transmitter For level measurement in hazardous areas Model LH-20

973-SF 6 Analyzer. Precise and Stable SF 6 Gas Analyzer REFLECTING YOUR STANDARDS

High-performance submersible pressure transmitter For level measurement Model LH-20

OMNISTAR / THERMOSTAR. The efficient solution for gas analysis. Intelligent software. Wide range of applications.

Design Features. General Description

Features. Description

GFM. Typical Aluminum GFM Mass Flow Meter NIST MASS FLOW METERS. Principles of Operation. Design Features

Mass Flow Controller (MFC) for Gases

METHOD 3C - DETERMINATION OF CARBON DIOXIDE, METHANE, NITROGEN, AND OXYGEN FROM STATIONARY SOURCES

Columbus Instruments

OXY Integral. INTERCON ENTERPRISES INC Tel: Fax: Internet:

Oxygen Flue Gas Analyzer BA 2000

Pressure transmitter PASCAL Ci4

GasSense NDIR User Manual

Hot extractive multi-channel gas analyser for continuous process and emissions monitoring.

Real-time gas analysis and software for the management of bioprocessing

HumiSys HF High Flow RH Generator

FAS-W. Features. Applications. Automatic condensation hygrometer

Installation and Operation Manual

Torque Tube TB300 Digital Transmitters

EasyLine EL3000 Series Continuous Gas Analyzers Models EL3020, EL3040

Vortex Flow Sensor VA Di Ex-d for flow measurement in gases; with integrated, configurable transducer UVA in Ex-d housing

C-Flow Coriolis Mass Flow Meters

High-performance submersible pressure transmitter For level measurement Model LH-20

Digital Mass Flow Meters and Controllers for Gases

AMS 6915 Board mount pressure sensor with digital output (I²C)

MASS-STREAM TM Instruction Manual. D-6200 Analog Mass Flow Meters / Controllers

CO, NO, NO 2, NO x, SO 2, CH 4, HCl, CO 2 & H ² O. Extractive low cost, low maintenance devices for continuous process and emissions monitoring.

GA24 Technical Datasheet

CO2 incubator with additional process controls

HCL MONITORING. ICAC MARAMA WORKSHOP May 18-19th, Presented by: Ty Smith. CEMTEK

HTD series digital differential pressure sensors

This test shall be carried out on all vehicles equipped with open type traction batteries.

Hot extractive multi-channel gas analyser for continuous process and emissions monitoring.

Electropneumatic Positioner and Pneumatic Positioner Type 3760 JIS

Datasheet: K-30 ASCII Sensor

Instructions for Installation, Start-up and Operation 41/ EN Rev. 6

The New PHD 4 Portable Helium Detector

NGN Series nitrogen generator

High Pressure Asher HPA-S

High-performance submersible pressure transmitter For level measurement Model LH-20

800 Series Mass Flow Meters and Controllers. High Performance Mass Flow Meters and Controllers

Operating Characteristics and Handling Manual for the NAP-55A / NAP-50A Explosive/Flammable Gas Sensor NEMOTO

Electrochemical Sensor

ME3-HCL Electrochemical sensor

MEGAS 2.0. Gas analysis with direct C-Level Calculation and Bus-Connection. Data sheet

Two-Wire In Situ Oxygen Analyzer (550 to 1400 C)

Mitos Fluika Pressure and Vacuum Pumps Datasheet

Transcription:

LFE OEM TCD - Thermal Conductivity Detector Key features Quick response - T90 3 sec Extremely suppressed ranges High corrosion resistance High temperature capability up to 180 C Infallible containment Integration into Ex d housings shown with optional flexible stainless steel tubing LFE's unique thermal conductivity detector is the heart of LFE's CONTHOS process TCD gas analyzer and has proven itself since 1979 in a wide range of applications. The TCD combines quick response, high corrosion-resistance and high-temperature capability without compromise. Further features are its extraordinary measurement stability, low range capabilities as well as highly suppressed ranges. OEM TCD LFE's thermal conductivity detector is available in an OEM (original equipment manufacturer) version which can be implemented into a customer's gas analyzer (system). The TCD OEM version can be integrated into in a standalone instrument or be used to complement other analysis principles such as for example NDIR/UV, Laser, or FTIR. Due to its high temperature capability LFE's OEM TCD can be integrated into thermostat controlled analyzer systems (e.g. 80-120 C) or close-coupled to customer high-temperature systems (up to 180 C). Such a combination of high-temperature NDIR/UV with LFE's high-temperature TCD has been approved in several tough process control applications from a well-established process analyzer company with high-temperature solutions between 80 and 180 C since 1985. Meanwhile the OEM version of the LFE TCD has been optimized making it attractive for more companies to round off their gas analysis portfolios. A special infallible (fail-safe) OEM version of the TCD is available for flammable and even explosive gases requiring special measures to be fulfilled. Typical Applications Metallurgical process gases - blast furnace Steel - heat treatment & hardening Petrochemistry - synthesis & reformer gas Gas purity - PSA, LEL/UEL & inert gas H 2 & O 2 purity water electrolysis Synthesis & reformer gas Coal, wood & biogas gasification Corrosive process gases with Cl 2, H 2 S and HCl Processes with H 2, water vapor and high dew points Processes in hazardous areas Page 1 of 5

LFE's Thermal Conductivity Detector In conventional gas analyzers utilizing the principle of thermal conductivity a heated object is suspended in a volume containing the sample gas. Electrical energy passed through the object results in the object heating up and attaining an equilibrium temperature which is primarily dependent upon the thermal conduction prop-erties of the surrounding gas. This temperature is normally measured directly as a change in the electrical resistance of the heated object itself. Features micro-miniaturized for quick response behavior corrosion and temperature resistant made of aluminum oxide (Al2O3), glass and SiOx-coated platinum sensor filaments LFE s unique principle modifies this "classical" method by spatially and electrically decoupling the heated element from the temperature sensing element. The specially designed geometry of the TCD cell in conjunction with the decoupling effectively suppresses undesired competing thermal effects (i.e. free and forced convectional effects). The result is an instrument whose quick, stable response requires no compromise between gas flow and response time. Technical data Electrical interface Power requirements Data / service interface Dimensions and Weight Dimensions Weight 24 VDC; 35 VA max. (during initial heat-up phase) Serial interface: RS232 in conjunction with isolated logic level converter Data block (proprietary protocol) includes raw value, system values such as TCD temperature, detector status and CRC Data in binary or plain text form Data block transmission on request or continuously refer to dimensional diagram 1.2 kg Materials in contact with sample gas Model with synthetic tubing Model with optional stainless steel tubing TC Detector Al 2O 3 ceramic and sapphire, glass and SiO x-coated Pt measuring filaments (high corrosion and temperature resistance) Gas lines PTFE / PFA SS 321; similar to 1.4541 Page 2 of 5

Measuring characteristics Note: The technical data is valid for operation of the OEM TCD within LFE's CONTHOS gas analyzer. The overall performance data for a particular implementation may depend on the chosen system integration, interfacing and signal processing options. Measuring principle Measured quantity Gas interference Measuring ranges Calibration Detector operating temperature Warm-up time Thermal conductivity (TCD) Difference in thermal conductivity ( λ) of various gases Concentration of a particular gas component in binary and quasi-binary mixtures. For the analyzer configuration, the knowledge of the sample gas composition is necessary. In complex (non-binary) gas mixtures, the measurement results may be affected by interfering components. Through the use of dynamic interference correction, the interference effects can be suppressed under certain circumstances. This must be implemented by the customer within his system or in conjunction with the appropriate optional interface expansion modules. Physical interference suppression is sometimes possible with certain gas combinations due to the wide temperature range of the CONTHOS' TC detector. Measured value signal output as raw value 2 nd and 3 rd ranges as option Optimized suppressed output ranges can be configured by the factory. lowest range: 0-0.5% H 2 in N 2 or 99.5-100% H 2 in N 2 (or equivalent λ) largest range: 0-100% H 2 The device outputs RAW values that are neither fine-calibrated nor linearized. The customer must provide the appropriate algorithms. TCD standard operating temperature: 70 C. Depending on the application, the operating temperature can be factory set to 60-180 C. Dependent upon TCD operating temperature as well as the ambient temperature: 70 C: approx. 20 min.; 140 C: approx. 90 min. For very small measuring ranges a longer warm-up time (overnight) is recommended. 3 sec (at 60 l/h gas flow and minimum signal dampening level) Response time τ 90 Influence of gas flow between 3-30 l/h: < 0.5% of range span for a gas flow change of ±10 l/h between 30-60 l/h: < 1% of range span for a gas flow change of ±10 l/h Higher flow rates up to e.g. 120 l/h are possible. At these higher flow rates it is recommended that the analyzer be calibrated at the operating flow rate. Strong gas flow fluctuations should be avoided. Pressure drop approx. 0.7 mbar at 60 l/h N 2 Pressure influence The TCD principle has a normally negligible pressure dependency. At very low ranges it can be seen as a proportional signal offset. Gas specific order of magnitude: < 0.02% H 2 equivalent per 100 mbar Detection limit 1 0.5% of span (at signal dampening level: 1 sec) Reproducibility 1 0.5% of span Response drift 1 Zero: 1% of span per week Span: 1% of span per week Influence of inclination no influence 1 at constant temperature and pressure Page 3 of 5

Sample gas requirements Sample gas temperature Sample gas dew point min.: +5 C max.: 10 C below detector thermostat temperature (typically 70 C) Dew point low enough so as to prevent condensation in the gas paths under all ambient temperature conditions Particles in sample gas The sample gas must be free of particles and aerosols. Sample gas pressure max. 300 mbar above atmospheric pressure Sample gas flow minimum: 3 l/h maximum: 120 l/h recommended: 30-60 l/h NOTE 1: All application and implementation details such as e.g. ranges and interfacing options must be clarified with manufacturer and evaluated for feasibility. NOTE 2: The technical data is valid for analyzer operation with pure bottled gases. Instrument specifications are based on binary or quasi-binary gas mixtures. Deviations from the above data can occur in conjunction with process gases depending upon the gas quality and the degree of sample handling. NOTE 3: The LFE OEM TCD is neither explosion-proof nor intrinsically safe in terms of explosion protection. NOTE 4: The LFE OEM TCD may not be employed for the analysis of ignitable gas mixtures. The customer must ensure compliance with applicable regulations when using the unit with flammable or toxic gases or when installing within hazardous areas. NOTE 5: The customer must ensure that the sample gas is dry and free of particulates. Page 4 of 5

Dimensions Technical specifications are subject to change without notice. LFE GmbH & Co. KG Process Analytical Instrumentation Am Germanenring 54 D-63486 Bruchköbel / Germany Tel.: +49-6181 - 49 53 02 Fax: +49-6181 - 49 38 07 www.lfe.de Page 5 of 5