OPESAVER Super Irrigation System

Similar documents
Insert to. Sponsored by Alcon Laboratories, Inc. February 2014 EXPLORING THE CATARACT REFRACTIVE SUITE FEATURING. The CENTURION Vision System

When evolution becomes

When evolution becomes

Basic Concept & Techniques of Phaco Prechop

plethysmographic methods that when the subject was pinched on the upper

ASICO Innovative I/A Tip System (Patented) Maximize your I/A efficiency for Today s MICS and FLACS procedure

Pressure and Flow Characteristics of Ocular Viscoelastic and Silicone Oil Through Glaucoma Drainage Devices

Getting Started GUIDE LEAVE A LEGACY OF EXCELLENT OUTCOMES FOR PATIENTS WITH ASTIGMATISM. TECNIS TORIC 1-PIECE IOL pg 1

The effect of external compression of the eye on intraocular pressure

International Council of Ophthalmology s Ophthalmology Surgical Competency Assessment Rubric (ICO-OSCAR) ICO-OSCAR Instructor Directions

Injector system for implantation of 1stQ foldable intraocular lenses

25+ instruments answer the most common barrier to 25G instrument flexibility.

Prof AH Basson, Pr Eng March Departement Meganiese en Megatroniese Ingenieurswese. Department of Mechanical and Mechatronic Engineering

OPHTHALMOLOGY THE BRITISH JOURNAL APRIL, 1925 COMMUNICATIONS TONOMETRY* SCHI6TZ. OPHTHALMOLOGY for May and June, 1920, I gave an account

In November 1998, the Staar AA4203 toric intraocular. Early rotational stability of the longer Staar toric intraocular lens. Fifty consecutive cases

Simulation analysis of the influence of breathing on the performance in breaststroke

VACUUM TESTING PRECAST CONCRETE MANHOLES

Influence of rounding corners on unsteady flow and heat transfer around a square cylinder

SOME TECHNICAL AND PRACTICAL RECOMMENDATIONS ABOUT PULSATION DAMPENERS IN CIRCUITS WITH DOSING OR VOLUMETRIC PUMPS

Purge Star & Ring Purge Systems

CHARACTERISTICS OF LEAK DETECTION BASED ON DIFERENTIAL PRESSURE MEASUREMENT

Today Mr. Happer told us to use the following physics vocabulary words and relate them to our experiment:

Flow experiment with the ibidi pump system and µ-slide I 0.6 Luer

AIAA Brush Seal Performance Evaluation. P. F. Crudgington Cross Manufacturing Co. Ltd. Devizes, ENGLAND

Leadership in Fluid Management

CHAPTER IV FINITE ELEMENT ANALYSIS OF THE KNEE JOINT WITHOUT A MEDICAL IMPLANT

Introduction. Medley TM Medication Safety System. Alaris Medical Systems

CORESTA RECOMMENDED METHOD N 6

Body Stabilization of PDW toward Humanoid Walking

. In an elevator accelerating upward (A) both the elevator accelerating upward (B) the first is equations are valid

RocaFlow. Irrigation and Warming System

Endotracheal Tube Exchanger. Technology for License

Chapter 4: Ventilation Test Bank MULTIPLE CHOICE

Boyle s law Verifying the relation between air pressure and volume measuring air pressure in a closed container.

Investigative Study: Movement Analysis

(fig. 3) must be at the same temperature as the water in this chamber CALORIMETRIC STUDIES OF THE EXTREMITIES

Physics Experiment 17 Ideal Gas Law Qualitative Study

ELEVATION CORRECTION FACTORS FOR RADON MONITORS*

Pressure Sensor Experiment Guide

Experimental Verification of Integrated Pressure Suppression Systems in Fusion Reactors at In-Vessel Loss-of -Coolant Events

Materials: Balloon demo (optional): - balloon, string, drinking straw, flour (optional)

Manual Small Incision Cataract Surgery

Robot Arm Challenge Answer Key

Test Bank for Pilbeams Mechanical Ventilation Physiological and Clinical Applications 6th Edition by Cairo

PERFORMANCE AND CHARACTERISTICS OF COMPRESSOR/EXPANDER COMBINATION FOR CO 2 CYCLE ABSTRACT

THE TOP 100 KEYWORDS FOR AN

The physiological functions of respiration and circulation. Mechanics. exercise 7. Respiratory Volumes. Objectives

CARBON DIOXIDE ELIMINATION FROM SEMICLOSED SYSTEMS

Experimental Analysis on Vortex Tube Refrigerator Using Different Conical Valve Angles

DS/PI-14 DIAPHRAGM SEAL TEMPERATURE ERROR

Unit 2 Kinetic Theory, Heat, and Thermodynamics: 2.A.1 Problems Temperature and Heat Sections of your book.

UNIT 15 WATER HAMMER AND SURGE TANKS

Hurdle races recognized in the current competition regulation of the Spanish Athletics Federation are the followings:

VACUUM REGULATORS CONTENTS

Mitos Fluika Pressure and Vacuum Pumps Datasheet

Managing and Recycling Human Energy: A Mechanical Redesign of the UCSC Lower Limb Exoskeleton. Rachel Rieger, Jacob Rosen

C) miles per hour. D) all of the above. 2) When you look at the speedometer in a moving car, you can see the car's

Cambridge International Examinations Cambridge International General Certificate of Secondary Education

Transverse waves cause particles to vibrate perpendicularly to the direction of the wave's motion (e.g. waves on a string, ripples on a pond).

The NAMIC Dream Kit. Single Operator Control. Reduce Contrast Waste. Less Force to Inject. Compensator * Manifold. How the Compensator Manifold Works:

Chapter 2. Turbulence and the Planetary Boundary Layer

Experiment. THE RELATIONSHIP BETWEEN VOLUME AND TEMPERATURE, i.e.,charles Law. By Dale A. Hammond, PhD, Brigham Young University Hawaii

CALIBRATION OF TONOMETERS*

Development of High-speed Gas Dissolution Device

PROBLEM SET 8. SOLUTIONS April 15, 2004

The relationship of pressure and aqueous outflow in enucleated human eyes*

Lesson 6: Flow Control Valves

Meteorology & Air Pollution. Dr. Wesam Al Madhoun

LarySeal - Laryngeal Mask Airways

AIS data analysis for vessel behavior during strong currents and during encounters in the Botlek area in the Port of Rotterdam

Design of an Automated Perfusion Pump James J Higham

College of Engineering

Eye Floaters Rhode Island Keyword Search Report

SIMULTANEOUS RECORDINGS OF VELOCITY AND VIDEO DURING SWIMMING

Very Basic Design Considerations for Water-Bottle Rockets

LYMPHA PRESS MANUFACTURED BY MEGO AFEK IMPORTED BY LYMPHA PRESS USA, Ltd. USERS MANUAL LYMPHA PRESS MODEL 201-M

Drilling Efficiency Utilizing Coriolis Flow Technology

4/18/12 MECHANISM OF RESPIRATION. Every Breath You Take. Fun Facts

An introduction to modern scleral lenses

STIFFNESS INVESTIGATION OF PNEUMATIC CYLINDERS. A. Czmerk, A. Bojtos ABSTRACT

Collin County Community College. Lung Physiology

3 1 PRESSURE. This is illustrated in Fig. 3 3.

Effects of transglottal pressure on fundamental frequency of phonation: Study with a rubber model

WMO LABORATORY INTERCOMPARISON OF RAIN INTENSITY GAUGES

End of Chapter Exercises

Flow meter. bellow vaporizer. APL valve. Scavenging system

Autodesk Moldflow Communicator Process settings

Bicycles 2. Bicycles 1. Bicycles 4. Bicycles 3. Bicycles 5. Bicycles 6

Test Method of Trap Performance for Induced Siphonage

arxiv: v1 [physics.ins-det] 6 May 2016

Lab 4: Transpiration

TECHNICAL BENEFITS OF CJS / RAISE HSP. Technical Advantages

Chapter 3 PRESSURE AND FLUID STATICS

New Theory on Facial Beauty: Ideal Dimensions in the Face And its application to your practice

(Refer Slide Time: 0:26)

Ophthalmology Clinical Pearls A Quick Guide To Crystalens

Analysis of Backward Falls Caused by Accelerated Floor Movements Using a Dummy

γ water = 62.4 lb/ft 3 = 9800 N/m 3

Australian Journal of Basic and Applied Sciences. Pressure Distribution of Fluid Flow through Triangular and Square Cylinders

Sizing Pulsation Dampeners Is Critical to Effectiveness

Transcription:

OPESAVER Super Irrigation System Makoto Kishimoto, MD Dokkyo University School of Medicine Kishimoto Eye Clinic Moriyama City Shiga, Japan n ABSTRACT OPESERVER reduces the surge phenomenon during ultrasonic phacoemulsification. It is composed of a Y-shaped joint (connecting the irrigation tube to the ultrasonic handpiece) to which a silicone tube (3.5 mm in internal diameter, 5 mm in outer diameter, and 2 m in length) is connected. The opposite end of the silicone tube is closed. Making use of the spontaneous compression and inflation, which take place to make the anterior chamber pressure equal to the air pressure within the silicon tube, OPESERVER instantaneously releases the irrigation fluid (entering the silicon tube) into the anterior chamber, thus allowing avoidance of surge and stabilization of the anterior chamber. If OPESERVER is used, stability of the anterior chamber is remarkably improved even when cataract surgery is performed with the irrigation fluid bottle set at a height 30 to 40 cm lower than usual, thus contributing to improving the safety of surgery and promoting postoperative patient recovery. Because the use of OPESERVER involves only a simple change in the pattern of the irrigation side, it can be used in combination with existing methods for manipulation on the aspiration side, and there is no restriction on the type of the apparatus used for aspiration. (inhibition) depends on the aspiration side. 2 6 The mechanical solution for the prevention (inhibition) is almost impossible at present because the duration up to the onset of surge phenomenon is as short as 0.15 second. It is just conceivable for the surgeons to make the irrigation bottle height being lower (that the irrigation bottle height 7 must be lowered) because the intraocular pressure during the operation should be maintained as close to the normal level as possible. When I tried and sought the methods to stabilize the anterior chamber effectively, the air entered the anterior chamber and formed bubbles during the operation. When we inserted I/A, the bubbles became smaller due to the irrigation pressure. When the foot pedal was returned to the zero position to stop the irrigation, the bubbles became larger again. Every surgeon who conducted cataract surgery may have had such experience. This led to the development of OPESAVER. 8,9 n TECHNIQUE OPESAVER consists of a silicone tube (internal diameter 3.5 mm, external diameter 5 mm, length 2 m; Fig. 1). One F1 n HISTORICAL PERSPECTIVE For the purpose of performing the phacoemulsification (ultrasonic cataract operation) safely without placing excessive burden on a patient, 1 the top priority that should be considered is prevention of surge phenomenon. The surgical efficiency (of operation) is reduced, resulting in larger burden on the patients if the prevention Address correspondence and reprint requests to Makoto Kishimoto, Dokkyo University School of Medicine, Kishimoto Eye Clinic 1-10-8 Moriyama, Moriyama City, Shiga 524-0022, Japan (e-mail: makotoueno@senju.co.jp). FIGURE 1. OPESAVER.

AU1 FIGURE 2. One end of the tube is closed and the other end is attached to a Y-shaped joint (Fig. 3). An irrigation tube is connected to the female end of this Y-shaped joint (Fig. 4) and the male end is connected to the female end of phaco or ultrasonic (US) handpiece (Fig. 5). F2 end of the tube is closed (Fig. 2) and the other end is F3 attached to a Y-shaped joint (Fig. 3). An irrigation tube is connected to the female end of this Y-shaped joint F4 (Fig. 4) and the male end is connected to the female F5 end of phaco or ultrasonic (US) handpiece (Fig. 5). To understand the system of OPESAVER, we should know the mechanism of the surge phenomenon. To determine the variables of the anterior chamber pressure during the operation, we analyzed them by attaching an electronic tonometer to a simulated anterior chamber and using a device that can transform the electric signals of F6 the tonometer into a graph in real time on the PC (Fig. 6). F7 Figure 7 shows the internal pressure of anterior chamber in a graph. A refers to the condition in which the phaco tip (ultrasonic tip) opens and is released for aspiration. When the phaco tip (nose of ultrasonic tip) is occluded by the nucleus at a, the intraocular pressure increases. The bottle height corresponds to the FIGURE 4. Connection of irrigation tube. intraocular pressure at B. The higher the bottle is raised, the higher the intraocular pressure becomes. If the bottle height is 120 cm, the intraocular pressure at B becomes 111 mm Hg, whereas that at f and g reaches to 160 mm Hg, 10 times higher than the normal intraocular pressure. This sharp increase in intraocular pressure is attributable to the moment of inertia by which the irrigation keeps flowing. When aspiration flow comes into the phaco tip (ultrasonic tip is released) at b, the intraocular pressure goes down sharply as in C. Though the surge phenomenon has yet to be clearly defined, the author would like to define such plunge (b e) as the surge phenomenon. In this graph, 0 mm Hg in the broken line is against the atmospheric pressure but the broken line should go up further in the case of actual eyeball because the balance in the posterior capsule is maintained by the vitreous pressure and anterior chamber pressure. When the phaco tip opens again, the condition returns to D, which is the same as A in the beginning. FIGURE 3. Y-shaped joint. FIGURE 5. Connection of handpiece.

FIGURE 6. Mock-up anterior chamber pressure measurement system. FIGURE 7. Change in anterior chamber pressure. FIGURE 9. (A) When the irrigation fluid flows into the anterior chamber under normal conditions, aspiration occurs on the corresponding side without resistance. (B) When the nucleus occludes the end of the ultrasonic tip, the pressure changes. (C) When the nucleus is crushed, aspiration resumes. FIGURE 8. Difference by the height of the bottle.

AU2 FIGURE 10. Condition in the surgery. F8 Though plural causes are intricately involved, the causes of surge phenomenon are roughly classified into a sharp increase in the aspiration flow volume and a shortage of irrigation volume. For example, the irrigation bottle is raised sometimes to prevent the surge phenomenon. However, as shown in Figure 8, marked changes still occur in the internal pressure of anterior chamber because the elevation of bottle neither reduces the plunge in the FIGURE 12. (A) Eyes show clear on postoperative day one. (B) Eyes show clear on postoperative day one. FIGURE 11. (A) Normal. (B) OPESAVER attachment. surge phenomenon nor increases the irrigation volume at the onset of surge. Because irrigation occurs as a free fall from the irrigation bottle, the acceleration rate is always the same so long as the operation is performed on the earth. It takes about 0.5 second for the irrigation volume to reach from zero to the maximum. However, the surge phenomenon that lasts for about 0.15 second is already completed before the lapse of 0.5 second. The higher the bottle is raised, the larger the changes in the intraocular (internal) pressure of anterior chamber. 2 On the other hand, when OPESAVER is used, the air in A B (Fig. 9A) is slightly compressed while the irrigation fluid flows into the anterior chamber and the aspiration flows without resistance. When phaco tip (the nose of ultrasonic tip) is occluded by the nucleus, the pressure of irrigation fluid attributable to the irrigation bottle is applied inside the anterior chamber and the air in A B is further compressed to make the pressure closer to the level in the anterior chamber as much as possible. As a result, a small change occurs as shown in A C (Fig. 9B) and irrigation fluid flows into the connection tube in an amount (B C) corresponding to the decrease in the air. Because the pressure in the anterior chamber F9

sharply goes down when the nucleus is fragmented and aspired, the air in A C inflates to become A B (Fig. 9C) to bring the pressure closer to the level in the anterior chamber as much as possible. The irrigation fluid that is pushed back flows into the anterior chamber to maintain the stability. To sum up, OPESAVER maintains the stability in the anterior chamber by supplementing the irrigation volume that is required to maintain the normal and constant level. Because the pressure in the tube is always higher than the atmospheric pressure, no backflow of air occurs. Furthermore, considering that the pressure has nothing to do with the direction and position of the tube, a surgeon can arrange the tube freely so F10 as not to hamper the surgical procedure (Fig. 10). To determine the changes in the anterior chamber pressure, we compared them by attaching the electronic tonometer to a simulated anterior chamber and transformed the electric signals of tonometer into a graph in real time on a PC. The combination of a small tip and Sovereign (Advanced Medical Optics, Inc., manufactured by AMO, Inc.) was investigated. The aspiration pressure was set at 500 mm Hg, irrigation volume at 30 ml and bottle height at 60 cm (the nose of ultrasonic tip was regarded as 0 cm). The occlusion and release of nucleus were simulated by the open/close of aspiration tube. The condition by normal tube and that by OPESAVER F11 are shown in Figure 11A and Figure 11B, respectively. As shown in these figures, there is a definite difference. F12 n DISCUSSION As described above, the use of OPESAVER enables safer operation because the device keeps the anterior chamber more stable even if the bottle is lowered from the normal position by 30 to 40 cm. Because the anterior chamber pressure during the operation is lower and there are fewer changes in the pressure, the phacoemulsification process (nuclear processing) becomes smoother, and the ultrasonic time and irrigation fluid volume are reduced. As a result, the burden on the eyeball is also reduced. Furthermore, the inflammation on the post-operation day 1 is decreased and the cornea remains clearer (Figs. 12A and 12B). Therefore, favorable post operation recovery is expected. Due to the nature of free fall, setting the irrigating solution bottle in a high position causes a burden to the eyeball and does not result in the fundamental resolution to avoid surge phenomenon. Although OPESAVER is a very simple structure, it can correspond to the pressure change within the anterior chamber before it is complicated, because it is controlling with telescopic of the air that was compressed. As for OPESAVER, there is no influence to the aspiration side, due to connection on the irrigation side. The anterior chamber was stabilizing even when the bottle of irrigating solution is set at 35 cm high in the cataract operation by SOVEREIGN, which connected OPESAVER. n REFERENCES 1. Oki K. Measuring rectilinear flow within the anterior chamber in phacoemulsification procedures. J Cataract Refract Surg. 2004;30:1759 1767. 2. Mackool RJ. Storz Premiere/MicroSeal system description. In: Fine IH (ed). Phacoemulsification: New Technology and Clinical Application. Thorofare, NJ: Slack; 1996:83 100. 3. Okamoto T. Anterior chamber stability not improved by bypass flow of aspiration bypass system. Atarashii Ganka (Journal of the Eye). 1999;16:1567 1571. 4. Chang DF. High-vacuum bimanual phaco attainable with STAAR s Cruise Control. Ocular Surgery News 2003;3. 5. Wilbrandt HR. Evaluation of intraocular pressure fluctuations with differing phacoemulsification approaches. J Cataract Refract Surg. 1993;19:223 231. 6. Wilbrandt HR. Comparative analysis of the fluidics of the AMO Prestige, Alcon Legacy, and Storz Premier phacoemulsification systems. J Cataract Refract Surg. 1997;23: 766 780. 7. Alm A. Ocular circulation. In: Hart WM (ed). Adler s Physiology of the Eye. St. Louis: Mosby Year Book; 1992:212 216. 8. Kishimoto M. Air cushion tube system. Jpn J Ophthalmic Surg. 2001;14:549 552. 9. Kishimoto M. OPESAVER help maintain chamber stability during phaco. Ocular Surgery News 2005;23(2). AU3