Safety and efficiency go hand in hand at MVM Paks NPP

Similar documents
CONTENTS OF THE PCSR CHAPTER 1 - INTRODUCTION AND GENERAL DESCRIPTION

Review and Assessment of Engineering Factors

Safety Analysis: Event Classification

NUBIKI Nuclear Safety Research Institute, Budapest, Hungary

Nuclear safety Lecture 4. The accident of the TMI-2 (1979)

Ing. JOZEF BALÁŽ Ph.D. and Ing MILAN CVAN CSc

IAEA SAFETY STANDARDS for protecting people and the environment

EXPERIMENTAL SUPPORT OF THE BLEED AND FEED ACCIDENT MANAGEMENT MEASURES FOR VVER-440/213 TYPE REACTORS

FUNDAMENTAL SAFETY OVERVIEW VOLUME 2: DESIGN AND SAFETY CHAPTER F: CONTAINMENT AND SAFEGUARD SYSTEMS 7. CONTAINMENT HEAT REMOVAL SYSTEM (EVU [CHRS])

IAEA SAFETY STANDARDS for protecting people and the environment

ACCIDENT MANAGEMENT AND EPR AT DUKOVANY NPP

IEM on Severe Accident Management in the light of the accident at the Fukushima Daïchi NPP

FUNDAMENTAL SAFETY OVERVIEW VOLUME 2: DESIGN AND SAFETY CHAPTER I: AUXILIARY SYSTEMS. A high-capacity EBA system [CSVS] [main purge]

DESIGN OF REACTOR CONTAINMENT STRUCTURE AND SYSTEMS FOR NUCLEAR POWER PLANTS

Workshop Information IAEA Workshop

Considerations for the Practical Application of the Safety Requirements for Nuclear Power Plant Design

ASVAD THE SIMPLE ANSWER TO A SERIOUS PROBLEM. Automatic Safety Valve for Accumulator Depressurization. (p.p.)

Enhancing NPP Safety through an Effective Dependability Management

DESIGN OF REACTOR CONTAINMENT STRUCTURE AND SYSTEMS FOR NUCLEAR POWER PLANTS

Severe Accident Management Programmes for Nuclear Power Plants

RISKAUDIT GRS - IRSN Safety assessment of the BELENE NPP

Inspection Credit for PWSCC Mitigation via Peening Surface Stress Improvement

The «practical elimination» approach for pressurized water reactors

HTR Systems and Components

Technical Standards and Legislation: Risk Based Inspection. Presenter: Pierre Swart

DISTRIBUTION LIST. Preliminary Safety Report Chapter 19 Internal Hazards UK HPR1000 GDA. GNS Executive. GNS all staff. GNS and BRB all staff CGN EDF

IAEA Training in Level 2 PSA MODULE 8: Coupling Source Terms to Probabilistic Event Analysis (CET end-state binning)

SAFETY APPROACHES. The practical elimination approach of accident situations for water-cooled nuclear power reactors

Safety Standards for Decommissioning Activities

Ranking of safety issues for

DRAFT REGULATORY GUIDE DG-1074

SENSITIVITY ANALYSIS OF THE FIRST CIRCUIT OF COLD CHANNEL PIPELINE RUPTURE SIZE FOR WWER 440/270 REACTOR

Loss of Normal Feedwater Analysis by RELAP5/MOD3.3 in Support to Human Reliability Analysis

How to reinforce the defence-indepth in NPP by taking into account natural hazards?

Safety Classification of Structures, Systems and Components in Nuclear Power Plants

Nuclear Safety Regulation: Before and after Fukushima*

Level 2 PSA for the VVER 440/213 Dukovany Nuclear Power Plant

The Regulatory Framework Improvement for Safe Decommissioning of Nuclear Power Plants in Korea

IAEA Headquarters in Vienna, Austria 6 to 9 June 2017 Ref No.: CN-251. Ivica Bašić, Ivan Vrbanić APoSS d.o.o.

Upgrading Vestas V47-660kW

COMPRESSORS WITH SIDE STREAM

TEPCO s Safety Assurance Philosophy on Nuclear Power Generation Plants

SAFETY DEMONSTRATION TESTS ON HTR-10

Assessing Combinations of Hazards in a Probabilistic Safety Analysis

Supercritical CO2 Power Cycles: Design Considerations for Concentrating Solar Power

Evaluation and Demonstration of Safety of Decommissioning of

Ocean Observatories Initiative. Coastal & Global Scale Nodes. Hydrogen Safety. OOI Surface Mooring Hydrogen Safety Review

FUNDAMENTAL SAFETY OVERVIEW VOLUME 2: DESIGN AND SAFETY CHAPTER I: AUXILIARY SYSTEMS 2. VOLUME AND CHEMICAL CONTROL (RCV [CVCS])

Understanding the How, Why, and What of a Safety Integrity Level (SIL)

Human Reliability Analysis of Ultimate Response Guideline in a Compound Disaster. Hyatt Regency Tokyo, Japan April 16, 2013

10. SYSTEM ANALYSIS. The assessment consist of two elements: Safety Analysis Report and an independent Review of Safety Report.

RISK-INFORMED OPTIMIZATION OF SURVEILLANCE TEST INTERVALS. Sami Sirén 1, Kalle Jänkälä 2

GUIDE YVL 3.7 / 26 Se p t e m b e r 2008

Recent Research on Hazards PSA

Assessment of Internal Hazards

HEALTH AND SAFETY EXECUTIVE HM NUCLEAR INSTALLATIONS INSPECTORATE

Integrated Coping Strategies for Beyond-Design-Basis External Events

Justification of Risk Reduction through In-Service Inspection / REDUCE

Preliminary Failure Mode and Effect Analysis for CH HCSB TBM

Safety of Decommissioning: International Cooperation under the IAEA Coordination

V.H. Sanchez Espinoza and I. Gómez-García-Toraño

Safety Standards. of the Nuclear Safety Standards Commission (KTA)

Developments on Flow Rate And High Pressure Stability of Peroxide Dosing Pumps For The Chemical Industry

ALARA in Practice Reactor internal parts repair at the Temelín NPP

Extensive Damage Mitigation Guidelines (EDMG)

Kodiak Electric Renewable Energy Implementation. Colin Young System Engineer 4/26/2016

Visual Observation of Nucleate Boiling and Sliding Phenomena of Boiling Bubbles on a Horizontal Tube Heater

HOT TOPIC REPORT OF BOTTOM HEADER DEFECTED,YGN PLANT 5 IN 2003 KOREA HYDRO AND NUCLEAR POWER COMPANY

MELCOR code application to VVER440/V213 analyses

NE 405/505 Exam 2 Spring 2015

Helicopter Safety Recommendation Summary for Small Operators

How does Wind affect Coal (Cycling, Emissions and Cost)

Implementing IEC Standards for Safety Instrumented Systems

-. 30ýv. Entergy ARKANSAS NUCLEAR ONE - UNIT I IMPROVED TECHNICAL SPECIFICATIONS SUBMITTAL. 05/01101 Supplement Volume 2 of 2. (Sections 3.7 and 3.

Table 6: Schedule of Operational Commitments

Advanced Test Equipment Rentals ATEC (2832) OMS 600

EL-O-Matic E and P Series Pneumatic Actuator SIL Safety Manual

Using LOPA for Other Applications

DISTRIBUTION LIST. Preliminary Safety Report Chapter 7 Safety Systems UK HPR1000 GDA. GNS Executive. GNS all staff. GNS and BRB all staff CGN EDF

Introduction to the power sector baseline scenarios and the IRENA SPLAT-W/MESSAGE tool

THE LOVIISA NUCLEAR POWER PLANT DECOMMISSIONING PLAN UPDATE Matti Kaisanlahti NKS-R Decommissioning Seminar, Halden, Norway, November 2013

Classical Event Tree Analysis and Dynamic Event Tree Analysis for High Pressure Core Melt Accidents in a German PWR

Portuguese Market Outlook up to 2040

FLEXIBILITY: KEY TO UNLOCKING POWER SYSTEM TRANSFORMATION

A comparative study of FLEX strategies to cope with Extended Station Blackout (SBO)

SHUTDOWN SYSTEMS: SDS1 AND SDS2

HIGH FLOW PROTECTION FOR VARIABLE SPEED PUMPS

MIL-STD-883G METHOD

System Operating Limit Definition and Exceedance Clarification

DeZURIK. KSV Knife Gate Valve. Safety Manual

The Nitrogen Threat. The simple answer to a serious problem. 1. Why nitrogen is a risky threat to our reactors? 2. Current strategies to deal with it.

MDEP Common Position No AP

Verification and validation of computer codes Exercise

Dynamic Context Quantification for Design Basis Accidents List Extension and Timely Severe Accident Management

Workshop to Generate Guidelines For the Implementation of: 1 - Step 1 of State Safety Program (SSP) and 2 - Phases 1 & 2 of ICAO SMS

CNS In-Pool Assembly Mechanical Design for OYSTER Project

RELIABILITY OF ENERGY SYSTEMS

Connection Engineering Study Report for AUC Application: Fortis Okotoks 678S and High River 65S Upgrades

PI MODERN RELIABILITY TECHNIQUES OBJECTIVES. 5.1 Describe each of the following reliability assessment techniques by:

ASME BOILER CODE WEEK AND PRESSURE VESSEL CODE WEEK May 5-10, 2019 Grand and Little America Hotels, Salt Lake City, Utah

Transcription:

International Forum Atomexpo 2018 Safety and efficiency go hand in hand at MVM Paks NPP József Elter MVM Paks Nuclear Power Plant Ltd. Hungary

Start up Four of the VVER-440/V213 unit Power units up-rate each with 500 MW 30-year electrical life time capacity 50-year life time Started in the years: 1983, 1984, 1986 and 1987 Unit 1 14/12/1982 19/07/2007 2012 2032 - licenced Up-rated in the years : 2007, 2008, 2009 and 2006 Unit 2 26/08/1984 05/12/2008 2014 2034 - licenced 15 months fuel cycle: 2016, 2015, 2015 and 2016 Unit 3 15/09/1986 13/11/2009 2016 2036 - licenced Planned operation till: 2033, 2034, 2036 and 2037 Unit 4 09/08/1987 28/09/2006 2017 2037 - licenced Electricity production (2017): 16 097 GWh 2 14 May 2018 International Forum Atomexpo 2018

MVM Paks Nuclear Power Plant the only nuclear power plant in Hungary belongs to the MVM Hungarian Electricity Company Ltd. designed in the 70 s, commissioned in the 80 s 4 x VVER440/V213 reactors 30 years originally designed lifetime the largest and cheapest domestic source 3 14 May 2018 International Forum Atomexpo 2018

Core damage probability Continuous safety enhancement 5.0E-04 The enhancement of nuclear safety had been started in Paks already before the commissioning of Unit 4 in 1987 4.5E-04 4.0E-04 3.5E-04 3.0E-04 2.5E-04 2.0E-04 1.5E-04 1.0E-04 5.0E-05 0.0E+00 Internal fire & flood Internal initiators, shut down Internal initiators, full power 1994 1996 1998 2000 2002 2004 2006 2008 2010 2012 2014 1991 1994 AGNES Report (Advanced General and New Evaluation of Safety) 1996 2002 Safety Enhancement Measures design basis related 1993 2002 Review of seismic hazards, plant reinforcement 1993 2004 Reactor Protection System Reconstruction Addressed all the feasible modifications and improvements that could provide capability to cope with the design basis accidents (including seismic events) 2008 2014 Severe Accident Management To ensure long term goals (power up-rate and plant life extension of the units) the utility was willing to step forward to a higher level of defense 2011 2018 Targeted Safety Review (TSR) and corrective measures 4 14 May 2018 International Forum Atomexpo 2018

Technical modifications Protected sump strainers Fully digital reactor protection system with additional functionalities Relocation of the emergency feedwater system into a protected building 5 21 November 2017 International Public Dialogue-Forum and Exhibition AtomEco 2017

Seismic reinforcement 6 Qualification and upgrades High energy pipelines of primary circuit and equipment Building structure of the turbine and reactor hall Supporting frames (reactor building, localization towers) Other classified pipelines of primary circuit and the equipment Classified pipelines and equipment of secondary circuit, fixes of supporting steel structures in the turbine building Electrical and I&C equipment (batteries replaced, seismic instrumentation added) 21 November 2017 International Public Dialogue-Forum and Exhibition AtomEco 2017 Volume of work 250 fixes (GERB damper) 1360 t steel structure 300 t steel structure 760 fixes 160 t steel structure 1500 fixes 450 t steel structure

108 % reactor power up-rate ambitious safety upgrading program was completed, the safety level of the plant was recognized as high thermal efficiency of the secondary side was increased increase of the reactor thermal power as a response to the market challenges 7 14 May 2018 International Forum Atomexpo 2018 Unit 4, 28. September 2006

Plant modifications for power up-rate no significant reduction of any safety margins, no relaxation of any acceptance criteria or operational limits benefit shall be based on the advances in calculation and evaluation methods, and experience from more than 70 reactor years of operation 1. Introduction of the new fuel type OL 2. Reconstruction of primary pressure control system OL 3. Modernization of in-core monitoring system OL 4. Up scaling some of the trip signals SM 5. Change of the parameters of the hydro-accumulators SM 6. Boron concentration in the primary circuit: 13.5 g/kg SM 7. Modernization of the electrical generators cooling PT 8. Replacement of turbine inlet wheel PT 8 14 May 2018 International Forum Atomexpo 2018

Severe accident management -1 SAM Safety Goal for the operating reactors of the Paks NPP: Demonstrate that containment failure is physically unreasonable for accident classes which cannot be screened out based on probabilistic arguments. Cumulative frequency of large radioactive releases shall be lower than 10-5 per reactor year. The key elements of the SAM are: SAMG development and implementation. SAM measurements and instrumentation. Independent electrical back-up with outside connection points. Specific hardware modifications to mitigate SA consequences.

Severe accident management -2 Hardware modifications to ensure coolability and containment functions: In-vessel retention of molten corium through external cooling of the reactor pressure vessel. Hydrogen mitigation scheme including controlled removal of hydrogen by a set of PARs. Mitigation of long-term pressurization of the containment through spraying.

15 months fuel cycle Positive experience of the power uprate 500 MW, and 2 nd generation 4.2 wt% fuel assembly From 2009 the fuel producer (TVEL) offered fuel assemblies containing a higher enrichment The use of more highly enriched fuel was investigated, with a view to introducing longer fuel cycles. According to preliminary estimations 18-month cycles are not feasible. The core is small, and the necessary fuel enrichment for a realistic and economic 18-month cycle would exceed 5wt%. 15 month fuel cycle is feasible, with combined use of 4.2 and 4.7 wt% fuel Refueling outages could be optimally scheduled for a 4 unit plants (4x12=4x15) 11 14 May 2018 International Forum Atomexpo 2018

Long-term maintenance plan of Paks NPP C12 Unit 2016 2017 2018 2019 2020 2021 2022 2023 2024 2025 2026 2027 2028 2029 2030 2031 2032 1 26 26 26 56 26 26 26 42 26 26 26 56 26 26 26 42 26 2 42 26 26 26 56 26 26 26 42 26 26 26 56 26 26 26 42 3 26 42 26 26 26 56 26 26 26 42 26 26 26 56 26 26 26 4 26 26 42 26 26 26 56 26 26 26 42 26 26 26 56 26 26 120 120 120 134 134 134 134 120 120 120 120 134 134 134 134 120 120 C15 Unit 2016 2017 2018 2019 2020 2021 2022 2023 2024 2025 2026 2027 2028 2029 2030 2031 2032 1 26 56 26 26 26 42 26 26 26 56 26 26 26 42 2 42 26 26 26 56 26 26 26 42 26 26 26 56 3 26 42 26 26 26 56 26 26 26 42 26 26 26 4 26 26 42 26 26 26 56 26 26 26 42 26 26 26 94 108 94 94 104 108 94 108 108 104 94 108 94 94 104 108 94 Year 2016 2017 2018 2019 2020 2021 2022 2023 2024 2025 2026 2027 2028 2029 2030 2031 2032 Δ 26 12 26 40 30 26 40 12 12 16 26 26 40 40 30 12 26 12 15-month cycle save 12-40 days outage on each year Load factor increase by 2%

Key-elements of the C15 implementation To develop and introduce the higher enriched fuel 4.2 wt% 4.7 wt% Extended operating cycle 11 months run + approx. 1 month refueling outage 14 months run + approx. 1 month refueling outage Extended in-service inspection and maintenance periods 8 years 10 years (in case of critical components 8 years 5 years) according to ASME BPVC XI and OM Code 13 14 May 2018 International Forum Atomexpo 2018

Fuel for the recent, 15m cycle option VVER-440 standard 2nd generation fuel assemblies with a hexagonal shroud tube, central tube and 11 spacer grids 126 fuel rods with enrichments: 4.0%, 4.4%, 4.6% and 4.95% Average enrichment: 4.7% Six rods with UO 2 -Gd 2 O 3 pellets Enrichment profile is unique and optimized for our reactors to enable 15 months cycle None of the VVER units are operating with 15 months cycle Fuel cycle: 4 x 15 month; 102 assemblies/15 months (78 ass. with 4.7% and 24 ass. with 4.2%) 14 14 May 2018 International Forum Atomexpo 2018

Fuel assembly Gd-2_4.7 4.0 wt% 4.4 wt% Gd-2n 3.6 wt% 4.0 wt% 4.4 wt% 4.6 wt% 4,95 wt% 4.4 wt% + Gd 4,4 wt% + Gd C15 fuel assembly Enrichment Amount UO 2 4% 12 48 4,4%+Gd 30 132 4,6% 12 55,2 4,95% 72 356,4-126 591,6 Avg. - 4.695% C12 fuel assembly Enrichment Amount UO 2 3,6% 18 64,8 4,0% 24 96 4,4%+Gd 84 369,6-126 530,4 Avg. - 4.215% 15

Nuclear fuel management C15 vs. C12 1. cycle: 102 assemblies 2. cycle: 102 assemblies 3. cycle: 102 assemblies 4. cycle: 102 assemblies 5 years 1. cycle : 84 assemblies 2. cycle : 84 assemblies 3. cycle : 84 assemblies 4. cycle : 84 assemblies 5. cycle : 84 assemblies Total: 408 assemblies Total: 420 assemblies The number of spent fuel assemblies is decreasing: more economical use less spent fuel 16

15-month fuel cycle benefits Deterministic influences: Electricity Production Non-radioctive Waste Stress transients Spent Fuel +2% -5% -20% -3% Periodic Work Volume Collective Dose Radioactive Waste Overtime HR Cost -15% -15% -10% -10% Probabilistic influences: Core damage probability decrease Workplace accident probability - decrease Maintenance work risk decrease 17

Summary Continuous safety enhancement at the units Gen3 safety on a Gen2 plant CDF decreased by more than an order of magnitude Continuous performance and availability enhancement Safety margins should be preserved Any negative safety effects should be compensated Electricity production, TWh Load factor, % Paks NPP is going to operate until 2037 Spent fuel assemblies 1988 13 445 85.67 448 2017 16 098 91.88 326 +19.7% + 7% -27% 18 14 May 2018 International Forum Atomexpo 2018

THANK YOU FOR YOUR ATTENTION!