x act i Precision- Pressure Transmitter for Food Industry, Pharmacy and Biotechnology Stainless Steel Sensor

Similar documents
x act i Precision Pressure Transmitter for Food Industry, Pharmacy and Biotechnology Stainless Steel Sensor accuracy according to IEC 60770: 0.

LMP 307. Stainless Steel Probe. Stainless Steel Sensor. accuracy according to IEC 60770: standard: 0.35 % FSO option: 0.25 % / 0.

DMK 458. Pressure Transmitter for Marine and Offshore. Ceramic Sensor. accuracy according to IEC 60770: standard: 0.25 % FSO option: 0.

DM01. Battery Powered Precision Digital Gauge. Stainless Steel Sensor. class 0.05

PRODUCT CATALOGUE DIGITAL GAUGES

DM01. Please visit our website: Battery Powered Precision Digital Gauge. Stainless Steel Sensor. class 0.05

IDL01. Battery Powered Precision Digital Gauge for Leak Testing. Stainless Steel Sensor. class 0.05

OPTIBAR P 1010 C Technical Datasheet

ETd 04. Battery Powered Precision Digital Gauge. Stainless Steel Sensor. Type: ETd 04. class 0.05

High-performance submersible pressure transmitter For level measurement Model LH-10

Digitale manometers. TYPE: ETD-01, klasse 0.5. Specificaties HOOFDSTUK 6

Pressure Measurement Single-range transmitters for general applications

Type N-10, N-11 Hazardous Area Non-incendive Transmitters

KTE6000 / KTU6000 Series OEM pressure transmitters for industrial media

High-performance submersible pressure transmitter For level measurement Model LH-10

ATM.1ST/Ex - High Precision Transmitter

High-performance submersible pressure transmitter For level measurement Model LH-20

ED 701 Hygenic Pressure Transmitter

JUMO dtrans p30 Pressure Transmitter

Series INTELLIGENT PRESSURE- AND LEVEL TRANSMITTERS For all industries. Description ALL STAINLESS DESIGN

ATM.ECO/IS - Analog Transmitter with Temperature compensation

2 Overview. SITRANS P measuring instruments for pressure. Transmitters for gage and absolute pressure. Z series for gage pressure

Series INTELLIGENT PRESSURE- AND LEVEL TRANSMITTERS For all industries. Description ALL STAINLESS DESIGN

SITRANS P measuring instruments for pressure

Precision pressure sensor Basic version Model CPT6020

High-performance submersible pressure transmitter For level measurement Model LH-20

High-performance submersible pressure transmitter For level measurement in hazardous areas Model LH-20

A Higher Level of Performance. Data Sheet. Series Pressure and Level Transmitters. For more information, please visit >

ATM.ECO - Analog Pressure Transmitter

Technical Datasheet. D Series SMART Pressure Transmitter Model: DPC D-Series. Key Features. Series Overview. Product applications

AMS 2710 PCB pressure sensor module with V output

ATM/Ex - Intrinsically Safe Analog Pressure Transmitter - ATEX / IECEx Certified

High-performance submersible pressure transmitter For level measurement Model LH-20

ATM/Ex - Analog Pressure Transmitter

sitrans p Operating Instructions (de/en) Edition 03/2004

Gas density monitor With integrated transmitter Model GDM-100-TI

Pressure Transmitter P41

Bourdon tube pressure gauge for diaphragm seals

Programmable pressure and temperature transmitters PTM/RS485

Pressure transmitter PASCAL Ci4

SITRANS. Pressure transmitter SITRANS P, Z series for gauge and absolute pressure. Introduction. Safety instructions 2.

ATM - Analog Pressure Transmitter

Pressure Measurement. Transmitters for basic requirements SITRANS P Z for gauge pressure. 2/4 Siemens FI Overview

ATEX VACUUM PUMPS AND GAUGES CHEMICALLY RESISTANT, OIL-FREE AND SAFE

Technical Data. General specifications Switching element function Rated operating distance s n 2 mm

9700 Transmitter Submersible hydrostatic level transmitter

Differential Pressure Transmiter

ATM.1ST. Pressure transmitters CUSTOMER BENEFITS

Operating Instructions for Intrinsically Safe Pressure Transmitters Series DMG/******** for Hazardous Application in Coal Mining Industry

Programmable pressure and temperature transmitters PTM/RS485

1 Overview. Pressure Measurement Transmitters for basic requirements. 1/16 Siemens FI SITRANS P220 for gauge pressure

ATM/GR. Electronic pressure switches CUSTOMER BENEFITS

P900. P900, Datenblatt Seite 1 DESCRIPTION

INDUSTRIAL. Pressure Transmitters. Product Guide. Low cost to high accuracy portfolio. Ranges from 70 mbar to 1400 bar. Flexible, rugged and reliable

Climatic Independent Level Sensor LAR

Technical Data. General specifications. Rated operating distance s n 5 mm

AMS 6916 Board mount pressure sensor with ratiometric analog output

UNIK 5600/5700 Marine Certified Pressure Sensing Platform

Technical Data. Dimensions

Technical Data. Dimensions

Technical Data. Dimensions

High-speed pressure sensor Model CPT6140

Dimensions. Technical Data General specifications Switching element function DC Dual NC Rated operating distance s n 3 mm

Type S-10, S-11 General Purpose Pressure Transmitters

RTX 1000H Series. Versatile Transmitters for a World of Pressure. GE Measurement & Control. Features

Technical Data. General specifications Switching element function Rated operating distance s n 1.5 mm

NivuBar Plus II

ellison sensors international

Technical Data. General specifications Switching element function DC Dual NC Rated operating distance s n 3 mm. Short-circuit protection

SITRANS P measuring instruments for pressure

Technical Data. Dimensions

Ceramic Pressure Sensor

Wing Union/Hammer Union Pressure Sensors. Datasheet. Models 435/437

Dimensions. Technical Data General specifications Switching element function Rated operating distance s n 5 mm

C-Flow Coriolis Mass Flow Meters

Parametrable / Programmable Pressure Transmitter

L3 Pressure and Level transmitter

Precision digital pressure gauge Model CPG1000

2600T Series Pressure Transmitter Models 264DC Differential and 264HC Gage Level Transmitters. Kent-Taylor

1 Overview. Pressure Measurement Single-range transmitters for general applications. 1/16 Siemens FI US Edition

Hand-held pressure calibrator with integrated pump Model CPH6600

Technical Data. General specifications Switching element function DC Dual NC Rated operating distance s n 3 mm. Short-circuit protection

P9000 DESCRIPTION. For parts requiring RoHS compliance, please contact factory. P February /6

Certified according to DIN EN ISO 9001 Technical Datasheet TRICOR Series Mass Flow Meters

Climatic Independent Level Sensor LAR

PEM-EX-C. Figure: PEM-EX-C*A*G. ka054000en; Rev. 2.7 J

How to specify a product. Process Sensors and Mechanical Instruments

Relative pressure transmitter type 520

Technical Data. General specifications Switching element function Rated operating distance s n 5 mm

Instruction Manual Differential Pressure Transmitter

Technical Explanation

Programmable Submersible Level Transmitters

GA24 Technical Datasheet

Technical Data. Dimensions

Pressure Measurement Single-range transmitters for general applications

2600T Series Pressure Transmitter

Dimensions. Technical Data General specifications Switching element function DC Dual NC Rated operating distance s n 3 mm

Technical Data. General specifications. Rated operating distance s n 2 mm

L (up to 25 m) Electronic part. working temp.: Ñ IP 66 / IP67. Mounting bracket ÐÑ. Sensor type. working temp.:

EPRB-2 Pressure Transducer

Transcription:

Precision- Pressure Transmitter for Food ndustry, Pharmacy and Biotechnology Stainless Steel Sensor accuracy according to EC 60770: 0. % FSO Nominal pressure from 0... 400 mbar up to 0... 40 bar Output signals -wire: 4... 0 ma others on request Special characteristics turn-down :0 hygienic version flush welded diaphragm several process connections (G cone, Clamp, dairy pipe, etc.) integrated display and operating module Optional versions The precise pressure transmitter x act i has been especially designed for the food industry, pharmacy and biotechnology and measures vacuum, gauge and absolute pressure of gases, steams and fluids up to 40 bar. Several process connections e.g. thread or hygienic versions like Varivent, dairy pipe and Clamp with a flush welded diaphragm are available, which can be combined with a cooling element for media temperatures up to 300 C. The robust stainless steel globe housing has a high ingress protection P 67 and all characteristics for a residue-free and antibacterial cleaning. Preferred areas of use are Food ndustry Pharmacy S-version Ex ia = intrinsically safe for gases and dusts HART -communication cooling element for media temperatures up to 300 C Material and test certificates material mill test report according to DN EN 004-3.. specific test report according to DN EN 004-. BD SENSORS GmbH BD-Sensors-Straße Tel: +49 (0) 9 35 / 98-0 www.bdsensors.com D - 9599 Thierstein Fax: +49 (0) 9 35 / 98 - info@bdsensors.de

Pressure ranges Nominal pressure gauge / abs. [bar] 0.4 4 0 0 40 Overpressure [bar] 5 0 0 40 80 05 Burst pressure [bar] 3 7,5 5 5 50 0 0 higher pressure ranges on request; on demand we adjust the devices within the turn-down-possibility by software on the required pressure ranges Vacuum ranges Nominal pressure gauge [bar] -0.4 0.4 - - - 4-0 Overpressure [bar] 5 0 0 40 Burst pressure [bar] 3 7,5 5 5 50 Output signal / Supply Standard -wire: 4... 0 ma / V S = 30 V DC Option S-protection: -wire: 4... 0 ma / V S = 8 V DC S-protection / HART : -wire: 4... 0 ma with HART communication / V S = 8 V DC Current consumption max. 5 ma Performance Accuracy Perfomance after turn-down ± 0. % FSO - turn-down :5: no change - turn-down > :5: The accuracy is calculated as follows 0. + 0.05 x (turn-down - 5) % FSO e.g. turn-down 9: 0. + 0.05 x (9-5) % FSO = 0.6 % FSO Permissible load R max = [(V S V S min) / 0.0 A] Ω load during HART communication: R min = 50 Ω nfluence effects supply: 0.05 % FSO / 0 V permissible load: 0.05 % FSO / kω Long term stability ± (0. x turn-down) % FSO / year at reference conditions Response time 00 msec without consideration of electronic damping measuring rate 0/sec Adjustability electronic damping: 0 00 sec offset: 0... 90 % FSO turn-down of span: max. :0 accuracy according to EC 60770 limit point adjustment (non-linearity, hysteresis, repeatability) Thermal effects (Offset and Span) / Permissible temperatures Tolerance band 3, 4 ± 0. % FSO x Turn-Down in compensated range -0 85 C Permissible temperatures 5 medium: -40... 5 C for filling fluid silicon oil -0... 5 C for filling fluid food compatible oil environment: -0... 70 C storage: -30... 80 C Permissible temperature medium filling fluid silicon oil overpressure: -40 300 C vacuum pressure: -40... 50 C for cooling element 300 C filling fluid food compatible oil overpressure: -0... 50 C vacuum pressure: -0... 50 C 3 an optional cooling element can influence thermal effects for offset and span depending on installation position and filling conditions 4 for flange-, Varivent-, DRD-version: tolerance band offset ±.6 % FSO / tolerance band span ± 0.6 % FSO 5 for vacuum ranges and absolute pressure the max. medium temperature is 70 C; max. temperature of the medium for nominal pressure gauge > 0 bar: 50 C for 60 minutes with a max. environmental temperature of 50 C (without cooling element). Electrical protection Short-circuit protection permanent Reverse polarity protection no damage, but also no function Electromagnetic compatibility emission and immunity according to EN 636 Mechanical stability Vibration 5 g RMS (5... 000 Hz) according to DN EN 60068--6 Shock 00 g / msec according to DN EN 60068--7 Filling fluids Standard silicon oil Options food compatible oil (with FDA approval) (Mobil DTE FM 3; Category Code: H; NSF Registration No.: 3066) Halocarbon and others on request Materials Pressure port G" cone, Varivent, dairy pipe und clamp: stainless steel.4435 (36 L) DRD and flange: stainless steel.4404 (36L) Housing stainless steel.430 (304) Viewing glass laminated safety glass Seals (media wetted) none, not included in the scope of delivery Diaphragm stainless steel.4435 (36 L) options: Hastelloy C-76 (.489), Tantal (possible from bar on) Media wetted parts pressure port, diaphragm, seals (if existing) pressure a

Explosion protection Approval AX-x act i Safety technical maximum values Permissible temperatures for environment Connecting cables (by factory) Miscellaneous Display BExU 05 ATEX 06 X zone 0: G Ex ia C T4 Ga / D Ex ia C T85 C Da U i = 8 V, i = 93 ma, P i = 660 mw, C i = 0 nf, L i = 0 µh, the supply connections have an inner capacity of max. 7 nf to the housing in zone 0: -0... 60 C with p atm 0.8 bar up to. bar in zone : -5... 70 C capacitance: signal line/shield also signal line/signal line: 60 pf/m inductance: signal line/shield also signal line/signal line: µh/m LC display, visible range 3.5 x.5 mm; 5-digit 7-segment main display, digit height 8 mm, range of indication ±9999; 8-digit 4-segment additional display, digit height 5 mm; 5-segement bargraph; accuracy 0.% ± digit ngress protection P 67 nstallation position any (standard calibration in a vertical position with the pressure port connection down; differing installation position for P N bar have to be specified in the order) Weight min. 400 g (depending on mechanical connection) Operational life > 00 x 0 6 pressure cycles CE-conformity Wiring diagrams EMC Directive: 004/08/EC -wire-system (current) -wire-system (current) HART P supply + VS P supply + VS supply supply Pin configuration Electrical connections Mx (4-pin) cable colours (DN 4700) Supply + Supply 3 wh (white) bn (brown) Shield plug housing gn/ye (green / yellow) Electrical connections () Mx (4-pin) Designs 6 side display 45 display 6 all designs in combination with G" cone in horizontal rotatable housing as standard; other mech. connections in rotatable housing on request www.bdsensors.com

Dimensions (in mm) G" cone Clamp (SO 85) Dairy pipe 7 (DN 85) size " /" " A 50.5 50.5 64 PN 6 6 6 size DN 5 DN 40 DN 50 A 44 56 68.5 B 0 0 PN 40 40 40 Varivent Flange 8 (DN 50) flush diaphragm E DN 40/50 PN 5 bar DRD 7 PN 5 bar size DN5 DN50 DN80 D 5 65 00 E 30 89 89 k 85 5 60 b 8 0 0 n 4 4 8 d 4 8 8 PN 40 40 6 Cooling element temperature range 300 C 7 cup nut resp. mounting flange is included in the delivery (already pre-assembled) 8 DN80/PN6 possible for nominal pressure ranges P N 6 bar HART is a registered trade mark of HART Communication Foundation; Hastelloy is a trademark of Haynes nternational nc.; Varivent is a trademark of GEA Tuchenhagen GmbH; Windows is a registered trade mark of Microsoft Corporation This data sheet contains product specification, properties are not guaranteed. Subject to change without notice. xact i_e_604 pressure Tel: a +49 (0) 9 35 / 98-0 www.bdsensors.com Fax: +49 (0) 9 35 / 98 - info@bdsensors.de

Ordering code x act i x act i - - - - - - - - - - Pressure nput Design gauge absolute 5 5 [bar] 0... 0.4 4 0 0 0 0... 0 0 0... 0 0 0... 4 4 0 0 0... 0 0 0 0 0 0 0 0... 40 4 0 0-0.4 0.4 S 4 0 0 - S 0 -... V 0-4 V 4 0-0 V 0 3 9 9 9 9 consult side display 45 display K H K 4 Output 4 0 ma / -wire ntrinsic safety 4 0 ma / -wire ntrinsic safety 4 0 ma / -wire with HART -communication E 9 consult Accuracy 0. % Electrical connection Male plug Mx (4-pin) M 0 9 9 9 consult Mechanical connection G" cone Clamp " (SO 85) Clamp /" (SO 85) Clamp " (SO 85) Dairy pipe DN 5 (DN 85) Dairy pipe DN 40 (DN 85) Dairy pipe DN 50 (DN 85) Varivent â DN 40/50 Flange DN 5 / PN 40 (DN 50) Flange DN 50 / PN 40 (DN 50) 3 Flange DN 80 / PN 6 (DN 50) DRD Ø 65 mm K 3 C 6 C 6 C 6 3 M 7 3 M 7 5 M 7 6 P 4 F 0 F 3 F 4 D R D Diaphragm Stainless steel.4435 (36L) Hastelloy 4 Tantal H T consult Seals without 0 Filling Fluids Silicon oil food compatible oil Halocarbon Special version standard with cooling element up to 300 C if setting range shall be different from nominal range please specify in your order absolute pressure possible from bar cup nut resp. mounting flange is included in the delivery (already pre-assembled) 3 DN80/PN6 possible for nominal pressure ranges up to 6 bar 4 tantal diaphragm possible with nominal pressure ranges from bar HART is a registered trade mark of HART Communication Foundation; Hastelloy is a brand name of Haynes nternational nc. Varivent is a brand name of GEA Tuchenhagen GmbH C consult 9 consult 0 0 0 0 0 0.0.03 This price list contains product specification; properties are not guaranteed. Detailed information about options are defined in the datasheet. Subject to change without notice.