New product release. Universal Rebreather Monitor (URBM) Three cell / Independent backup

Similar documents
New product release. Universal Rebreather Monitor (URBM) Single O2 cell and Dual HP package

OperatorsManual. Multi gas, multi mode decompression computer

Shearwater GF Computer

VR Series Dive Computer Manual

Syllabus Number: 3.B.35 / BOD n. 188 ( ) CMAS CCR Diver diluent air/nitrox Training Program Minimum Training Program Content

Understanding CCR - In Depth

VR Series Dive Computer Manual

Electronic controller for Closed Circuit Rebreather USER S MANUAL. version 1.0

User Manual. Heads-Up Display (HUD) DiveCAN. Mechanical Button Version

English. English. Predictive Multi Gas for

RB70 Automatic Diluent Valve Maintenance Manual. Version 1.1 November 2006 Written by Tino de Rijk. Page 1 of 23

RAM Operation Manual. Worldwide Manufacturer of Gas Detection Solutions

PC Configuration software for Discovery MkVI v 1.03 User guide

Parts List Poseidon Discovery

RAM 4021 Operation Manual

VMS RED SERIES CCR. User Manual

POSEIDON M28 USER MANUAL 1.2 fw version 1.8

POSEIDON M28 USER MANUAL 1.4 OS version 2.1.7

24. Basic Closed Circuit Rebreather Decompression Procedures Instructor - Unit Specific

OxyCheq Expedition-X Oxygen Analyzer. Operator s Manual

VMS RED SERIES CCR. User Manual

Besides all the normal preparation, this highlights the typical rms features

revo air diluent course procedures

! All activations or settings on the revodream always start when the unit is OFF (except switching OFF)

MSL GEM Sidekick R.4

PHOTO: JONAS DAHM / DEEP SEA PRODUCTIONS VERSATILE REBREATHERS FOR SKILLED DIVERS

COVER PHOTO: JONAS DAHM / DEEP SEA PRODUCTIONS VERSATILE REBREATHERS HANDCRAFTED IN DENMARK

Shearwater Pursuit Manual

RAM 4021-PR. Operation Manual. Worldwide Manufacturer of Gas Detection Solutions

POSEIDON SE7EN Appendix 3, version 1.2. SE7EN connected to M28

RAM 4021-DPX Operation Manual

RAM Operation Manual

SMART Oxygen Analyzer. User Manual

RAM Operation Manual. Worldwide Manufacturer of Gas Detection Solutions

DIVECOMPUTER.EU USER MANUAL V3.0

RESA Standards V1.0 16/08/18

Color Dive Computer. Instruction Manual

Device overview. 6 Breathing circuit connection. Note: When the remote control foot pedal is connected, the manual switch is disabled.

mini Quantum SG User Manual

RESA STANDARDS V2.0 15/12/2018

Ver. 2 Displays And Electronics User Manual

USER MANUAL OPERATION AND THE USE OF A CAR WITH. Diego G3 / NEVO SEQUENTIAL GAS INJECTION SYSTEM

31. Air Diluent Closed Circuit Rebreather Decompression Procedures Diver, Unit Specific-

ECHO MANUAL WARNING. L B A ltim e te rs. ECHO is a trademark of LB Altimeters, Denmark

ENGLISH. uemis ZURICH. SDA Scuba Diver Assistant Quick Reference Guide

HUDC User Manual Head Up Dive Computer Vers: 1.3 Mar. 2014

29. Air Diluent Closed Circuit Rebreather Diver, Unit Specific

Experiment B-3 Respiration

Rebreather Training Council Standard

PRO PLUS 2. dive computer. operating manual

VERSION

KISS SPIRIT LTE. Retail price $ 4, KISS Spirit LTE includes:

THIS MANUAL REMAINS THE COPYRIGHT OF AMBIENT PRESSURE DIVING LTD AND CANNOT BE REPRODUCED WITHOUT PRIOR WRITTEN APPROVAL.

XP EINS USER MANUAL. Contents: 1.1XP EINS USER S MANUAL

KISS REBREATHERS CLASSIC KISS MANUAL. MSL Jetsam/Classic KISS manual R.5

Juergensen Marine. Hammerhead CCR Instruction Manual Revision 3.0. Written by Joseph Radomski Kevin Juergensen

Draeger Fabius GS Pre-Use Check

MP15 Jockey Pump Controller

When buying one of our prototypes you agree with this!

Rebreather Training Council Standard

PROPORTIONING VALVE. Model 150 INSTRUCTION MANUAL. March 2017 IMS Company Stafford Road

IBU3 Manual Addendum 1

INTRODUCTION TECHNICAL DATA SYSTEM OF DOCUMENTATION. scrubber duration limit CO 2. User support. Use of this manual. Version.

Matrix Dive Computer. Instruction Manual

SUUNTO EON CORE USER GUIDE

Oxygen Meter User Manual

AV1 MANUAL. dive computer. (revision 8/2015)

Standalone & EXT Models

Handi+ OPERATING MANUAL & INSTRUCTIONS FOR USE. R218P15 Industrial. R218M15 Rev. D

38. Rebreather Full Cave Diver

SUUNTO EON STEEL 1.6 USER GUIDE

Veo 200/250 dive computers operating manual

Dual-gas Oxygen and Carbon Monoxide SMART Analyzer User Manual

VT Pro dive computer operating manual

Color Dive Computer. Instruction Manual

BAILING OUT! YES BUT HOW?

WATER CONTROL SYSTEM QUICK START

LIMITED TWO-YEAR WARRANTY For details, refer to the Product Warranty Registration Card provided. COPYRIGHT NOTICE This owner s guide is copyrighted, a

Installation, Operation and Maintenance Instructions for Electronically Controlled Pressurisation Units

Bante821 Portable Dissolved Oxygen Meter Instruction Manual

DG100 Digital Depth Gauge and Timer. Training Module, Rev B

AutoChanger Installation & User Guide Issue 2

User manual. hwos tech. OSTC dive computer with the Firmware OSTC 2 TR OSTC 2. OSTC cr. OSTC plus

17. TDI Air Diluent Closed Circuit Rebreather Diver Course, Unit Specific- Inspiration / Evolution, KISS, Optima, Megalodon

19. TDI Mixed Gas Closed Circuit Rebreather, Unit Specific, Ambient Pressure Inspiration & Evolution, Diver Course

Rebreather User Manual

patient education program 4156 South 52 nd Street, Omaha, NE ChildrensOmaha.org/HomeHealthcare

20. TDI Advanced Mixed Gas Closed Circuit Rebreather, Unit Specific, Ambient Pressure Inspiration & Evolution, Diver Course

SUUNTO D6I USER GUIDE

UBEC 1AT. AUTO TANK Fill System Installation, Operation, & Setup Instructions

Contact. For any questions relating to your OSTC sport please contact us via. internet forum: forum.heinrichsweikamp.com

KEY FEATURES FOR ALL DIVING

user Manual N O L I M I T

Aladin TEC 3G User manual

Introduction. The Shearwater Petrel is an advanced technical diving computer for open and closed circuit divers.

500AI. owner's guide

Product Information News

JJ-CCR Rebreather (CE Edition 2.00 / Revision 04)

GV Standard X-Vent. Setup, Commissioning & Installation Guide

Jetsam Technologies Ltd. Classic KISS Manual

Transcription:

New product release Closed Circuit Research is pleased to announce the launch of our range of Universal Rebreather Monitors Universal Rebreather Monitor (URBM) Three cell / Independent backup Key features and benefits include: Real-time PO2 and decompression information displayed on VR wrist unit A hard wired Heads Up Display (HUD) which indicates PO2 and decompression status Real-time PO2 monitoring from three Rebreather oxygen cells. PO2 set point alarms for the HUD, on user selected set points. Option of an independently powered backup display. Please note that due to the substantial reprogramming that is required for the VR wrist unit to be compatible with the monitor(s) some standard features of a stand alone VR3 must be removed, as follows: XB & XO the option to monitor information from a standard Rebreather 4 th cell display and O2 analyzer has been disabled. The IR link has been removed, therefore the VR can only be downloaded by using our USB hardwire connector and the new Prolink 2007 software. HP the stand alone High Pressure link option has been disabled. HP content information and features are only available via the Rebreather single PO2, 2 x HP monitor. Calendar function has been disabled Please note: The Core Module is potted and sealed; there is nothing to be adjusted inside. In the event of a failure, the entire Monitor must be returned intact. Any attempt to gain access to the Core Module will void the manufacturers warranty. 1

Universal Rebreather Monitor (URBM) Three cell version VR3 Wrist Display Optional Independent backup display HUD & Bracket Core Module Fischer connector to 3x P02 sensors on rebreather 2

Hardware connections Connect URBM cable according to your Rebreather manufactures guidelines. Calibration Select dive now (quick press on both switches) to keep the VR3 active for 5 minutes A long press on the left switch will take you into Gas select screen Make sure you are in Closed Circuit Mode and you see Closed CCT at the top of your screen. If not, go to Closed circuit mode by a long press on both switches. A quick press of both switches takes you into the Adjust screen. Move the cursor to select NX 99 in your gas list and switch it ON. A long press of both switches will save NX 99 as your diluent. Save it as the calibration gas (CAL) by a further long press on both switches. CAL GAS will appear on the screen. Then a quick press on the right hand switch will confirm and a further quick press on the right hand switch will take you back to the Dive Now screen. Remember, AFTER calibrating, to set the diluent setting back to the actual dive diluent. In the dive now screen toggle the O2 option by a quick press of the right hand switch. Then a long press on the right hand switch takes you into the SENSOR screen, where you will see the current PO2 displayed by the 3 cells. and a PO2 bar graph on the right. 3

A long press on both switches takes you into calibration mode (CAL). You will see the instructions Flush now Completely flood the Rebreather with oxygen, (usually achieved by flushing and emptying the loop with pure oxygen 3 times) and a quick press of the right switch takes you to the vent now screen. Then quickly vent the counter lung to ambient pressure and perform a quick press on the right switch. 4

This screen gives you the option to stop the calibration process by a quick press on the left switch or confirm the calibration with a quick press on both switches. The display will return to the original Sensor screen the Rebreather monitor is now calibrated. If the unit is incorrectly calibrated you get the message Bad PO2 Cal in the home screen, do not dive, check the sensor connections and the health of the cells on the rebreather and repeat the calibration process again. 5

Setup screen Q start feature A new feature added to the setup menu on the Universal Re-breather monitor is Q-Start. This all ows the user to choose between X (expert) and N (normal) modes. N mode has all the normal settings available on a standard VR3 X mode gives the user a choice in the DVo screen to turn on Average depth display, and large PO2 screen saver, also the choice to use Profile B or diluent as a bailout gas when going from closed circuit to open circuit. Instructions on how to access and navigate the setup screen are covered on page 19 and 25 in the VR3 manual. Normal mode and Expert mode The Rebreather monitor has two mode displays available normal mode N and expert mode X. These are user selectable via the setup screen before diving (you cannot change this setting during a dive). In the picture above X mode option is highlight and activated. 6

Dry screen savers This is the surface dry screen saver showing battery voltage and temperature along the top of the screen, average PO2 in large numbers on the left, selected diluent on the right and the actual PO2 of the three cells below. 7

Screen saver in dive mode Screensaver is the screen view that cuts in after a short delay when no switch has been pushed, (the delay period can be set in the DVo screen see Pg 10 of this guide.) When a switch is pushed the screen view returns to dive or surface mode, whichever is appropriate. Average PO2 is displayed in large numbers on the left of the screen. Current depth and time is displayed at the top of the screen. Current tissue loading in shown as a graph on the top left hand of the screen. Selected diluent and each individual sensor PO2 is shown in the bottom right. 8

On screen warnings Any system warnings are shown in the top right hand display, the warning in this picture shows a low battery warning and no signals from the oxygen sensors. When using a colour screen the right hand side of the display changes to red to draw the diver s attention to the fact that a warning is in force. 9

DVo Screen This is the DVo screen accessible by a long press of the left switch when the DVo icon is displayed in the home screen. A quick press of both switches moves the cursor between functions. XDec On activates real-time decompression calculations based on the external sensor readings XDec Off diverts decompression calculations to the VR fixed set points. HUD allows the user to adjust the brightness of the HUD from completely off to 9 which is the brightest setting. ScrSv Adjusts the time between home screen and screen saver. It can also give you the option to switch the screen saver off. BG Is the option for bigger graphics Light adjusts the backlight options Stop D allows the user to choose the final stop depths; 3m (10ft), 4.5m (15ft) and 6m (20ft). For further information on the DVo screen please refer to page 16 to 18 of the VR3 manual. 10

HUD Operations The Heads Up Display (HUD) is designed to fit on a mounting bracket and attach to the side of the mouthpiece of the rebreather; it contains 2 LEDs, one red and one green. PO2 HUD parameters SOLID GREEN LED PO2 within 0.2 of VR set point (normally set at the PO2 of the rebreather s set point controller). Instructions on how to adjust the VR set point is on page 39 of the VR3 manual. SLOW FLASHING GREEN LED PO2 more than 0.2 below VR set point. FAST FLASHING GREEN LED PO2 more than 0.2 above VR set point SOLID RED LED Within +/- 1 metre (3 feet) of decompression stop depth. SLOW FLASHING RED LED In decompression and below the decompression ceiling, FAST FLASHING RED LED Decompression ceiling violated (descend until RED LED turns SOLID) 11

FAST FLASHING RED LED PO2 is > 1.6 or <0.3. RED LED FLASH WHEN ON SURFACE BEFORE DIVE Red LED will flash slowly on surface mode this is so the diver knows it is operational before a dive. CCR Bailout Options When bailing out to open circuit follow the instructions on page 40 of the VR3 manual. When X mode is selected in Q-Start and you bailout to open circuit you get the option either to bailout to your diluent gas (DIL) or to one or more deco gases that you leave preset in profile B (PrB). To select this option make a quick switch on the corresponding symbol, check the details are correct on the select screen and tick it. You are now on your bailout gas. The instructions on how to add and save a profile are on page 20 of the VR3 manual. Once in open circuit mode the XDec information is automatically switched off, the Screen saver mode is also disabled. The red HUD decompression LED will still be active and can still be used as a guide when decompressing in open circuit mode. If Closed Circuit mode is activated again the XDec automatically switches on and calculates decompression based on the current PO2 reading from the external oxygen cell. 12

If you enter the Bailout warning screen in error a long push on both switches (ABORT) will return you to the dive screen. O2 Sensor Polling The rebreather monitor has a method of automatically removing O2 sensor cells from the PO2 averaging. This is based on a set of rules. Rules: 1. If a single cell is below 0.15 bar or above 3.00 bar, then it will be disabled, the system denotes this with a N next to the cell. 2. If after item 1. all 3 cells are disabled for the same fault, then all cells will be re- enabled this ensures that if the O2 is very high, or very low and all the cells agree, the O2 is probably very high or low accordingly 3. If all cells are enabled and have no faults, then each cell is checked to see how many other cells it is within 0.20 bar of. a. If all cells are within 0.20 bar of each other, then all cells will be enabled. b. If two cells are within 0.20 bar of each other and one cell is not, then the cell that is not within 0.20 bar of the others will be disabled. c. If no cells are within 0.20 bar of each other, then all cells will be kept enabled. 4. If all 3 cells are disabled with the same fault at this stage, then all will be re- 5. All enabled cells are then used in the PO2 averaging. Any cell disabled in these enabled. calculations will have a N shown against it in the O2 sensor screen. In the picture above cell 3 has automatically been disabled from the system. 13

Sensor Polling Examples a. Cell 1 = 0.50 bar, cell 2 = 0.60 bar, cell 3 = 0.70 bar. All cells used (rule 3a). b. Cell 1 = 0.30 bar, cell 2 = 0.60 bar, cell 3 = 0.70 bar. Cells 2 and 3 only used (rule 3 b). c. Cell 1 = 0.30 bar, cell 2 = 0.60 bar, cell 3 = 0.14 bar. Cells 1 and 2 only used ( rule 1). d. Cell 1 = 0.30 bar, cell 2 = 0.60 bar, cell 3 = 0.90 bar. All cells used as no obvious fault in any single cell (rule 3c). Optional Backup display The backup display has 3 PPO2 readouts which read 3 individual sensors, an independent battery compartment, and 3 calibration potentiometers, one for each sensor. To turn the display on push the top button; the PPO2 for each sensor will be displayed. To display the sensor s millivolts, push the bottom button and hold. This should be done while exposing the sensors to air. To be safe to dive, the reading must be higher than 7 millivolts. Note, you must be able to calibrate the sensors in both air and oxygen. If the sensors are unable to be calibrated in both air and oxygen, discard them. They are no longer safe to dive. 14

BATTERY There is a red indicator LED light at the top of the display. When the battery needs to be changed, the red LED will stay on permanently WHEN A BUTTON IS PRESSED. To change the battery, unscrew the battery compartment cap which is located at the bottom of the display, opposite the bottom button, on the other side of the cable. To open the compartment, use either the included tool or insert the tips of a set of pliers into the holes. While the compartment is open inspect the O-rings. Check them to ensure they are in good condition, clean and then apply fresh lubricant. The display takes a AA size battery. For best results, a 3.6v lithium battery should be used. Insert the battery with the + side inwards. Secure the battery compartment cap. Push the top button on the display to turn it on. Ensure that the red LED light is off. The display should turn off automatically after a few moments. Note that the red LED light will turn on for a moment, just as the display is about to turn off. This is normal. WARNING: WHEN THE LOW BATTERY INDICATOR LIGHT COMES ON, THE BATTERY MUST BE CHANGED!!!! DIVING WITH A LOW BATTERY WILL AFFECT THE PPO2 READINGS!!!! THIS CAN CAUSE INJURY OR DEATH!!!! CALIBRATION First ensure that the battery is good. To adjust, turn the black cap on the back side of the display. Each cap will have a number beside it that corresponds with a display. Turn the black cap using a large coin or similar tool. If you can not turn the cap and have run out of range, turn the cap all the way in and start over again. BE VERY CAREFUL TO NOT SCREW THE CAP ALL THE WAY OUT. THIS WOULD EXPOSE THE SEALING O-RING AND IF TAKEN UNDERWATER, WOULD FLOOD THE DISPLAY!!! 15

If you have trouble calibrating the display, expose the sensors to air and check the millivolts. They should read over 7 millivolts. If the millivolts are correct, start the calibration procedure again. Screw the black cap all the way in and then back out again. If for some reason the black calibration cap is completely undone, clean and lubricate the O-ring on the waterproof cover and also the internal O-ring. Replace the cap. BE EXTREMELY CAREFUL TO NOT CROSS-THREAD THE CAP!! The displays should be calibrated with oxygen. The procedure for this is as follows: 1. Ensure that the diluent tank valve is closed. 2. Draw all of the gas out of the loop. Do this by putting the DSV into your mouth, open the loop, inhale the gas into your lungs and then exhale it out of your nose. *Note: it is important that you do not exhale any gas back into the loop while doing this. 3. With the loop closed, open the oxygen tank and press the manual add valve button, adding oxygen into the loop until the exhaust valve burps. 4. Repeat steps 2 & 3 until the loop has been completely flushed with oxygen. This usually takes 3 to 4 flushes. 5. Once the loop has been completely flushed, close the oxygen cylinder and open and close the DSV quickly to bring the gas in the loop to ambient pressure. With the loop closed, calibrate to 1.00. The readings can be verified with air. To verify with air, first ensure that both tank valves are turned off. Then, remove the loop hose which is attached to the exhaust side of the DSV. Put the DSV into your mouth, open the loop and breathe. This will draw fresh air through the loop and eliminate the pure oxygen which you flushed the loop with. It will take a few minutes for the oxygen percentage to drop. 16