Manual. NatVent IAQ office ventilation program NaVIAQ V1.3

Similar documents
RM-80 respiration monitor

Workshop 1: Bubbly Flow in a Rectangular Bubble Column. Multiphase Flow Modeling In ANSYS CFX Release ANSYS, Inc. WS1-1 Release 14.

The ICC Duckworth-Lewis Calculator. Professional Edition 2008

CONSUMER MODEL INSTALLATION GUIDE

Pegas 4000 MF Gas Mixer InstructionManual Columbus Instruments

Technology. In the My Files [My Files] submenu you can store all the programs that you have made on the NXT or downloaded from your computer.

The ICC Duckworth-Lewis-Stern calculator. DLS Edition 2016

Wire Buddy Manual IOpath Software

ScoreKeeper tm. ~ Software for Golf ~ for Microsoft Windows 98 through Windows 7. User's Guide

TESLAGON. ShotHelper Manual. How to install and use the Program. Version /30/2014

ALGE DIVE! ALGE. ALGE-TIMING GmbH & Co

Microsoft Windows Software Manual for FITstep Stream Version 4

Window and Door Measurement System

TESTING AT VERY LOW FLOWRATE

1)! DO NOT PROCEED BEYOND THIS MARK

Results of Field Measurements and CONTAM Simulation. Building Science

Race Screen: Figure 2: Race Screen. Figure 3: Race Screen with Top Bulb Lock

FRDS GEN II SIMULATOR WORKBOOK

Blackwave Dive Table Creator User Guide

Chapter 14 Coal Boiler Flue Gas Scrubber II

Sesam HydroD Tutorial

APBA Baseball for Windows 5.75 Update 17

UNITY 2 TM. Air Server Series 2 Operators Manual. Version 1.0. February 2008

Exercise 3. Power Versus Wind Speed EXERCISE OBJECTIVE DISCUSSION OUTLINE. Air density DISCUSSION

Navy Guidance and Tips for Using DOEHRS-IH Ventilation NAVY & MARINE CORPS PUBLIC HEALTH CENTER

Quick Start Guide. A. Hardware installation B. Software installation C. Start the software for the first time D. Do your first measurement

KISSsoft 03/2016 Tutorial 9

GA-300 Gas Analyzer. Technical Note. Overview. Front Panel. iworx Systems, Inc. GA-300

MoLE Gas Laws Activities

WATCH COLLECTION NG701 SERIES INSTRUCTION MANUAL

Revision: 23 March 2008 (nk)

LEO SEM SOP Page 1 of 9 Revision 1.4 LEO 440 SEM SOP. Leica Leo Stereoscan 440i

Quintic Automatic Putting Report

Burner Management System DEMO Operating instructions

Users Guide for the CableSoft Software Package

MoLE Gas Laws Activities

Experiment AMe-1: Small Animal Respiratory Exchange Ratio (RER)

Operation Manual. Software. FanTestic Integrity (complying with NFPA 2001) rev

USER MANUAL April 2016

Instruction Manual. BZ7002 Calibration Software BE

FireHawk M7 Interface Module Software Instructions OPERATION AND INSTRUCTIONS

This test shall be carried out on all vehicles equipped with open type traction batteries.

[MYLAPS INTEGRATION]

Touch Screen Guide. OG-1500 and OG Part # T011

Quick Start Guide. For Gold and Silver Editions

Guidance on room integrity testing and its interpretation

VISIMIX TURBULENT. MECHANICAL CALCULATIONS OF A CONSOLE SHAFT

VISIMIX TURBULENT. HEAT TRANSFER PROCESS IN A SEMIBATCH REACTOR

LEGO Engineering Conferences ROBOLAB and MINDSTORMS Education Version 4.5 March 2008

Inprocess Operator Training Programme

1.2 Example 1: A simple hydraulic system

XC2 Client/Server Installation & Configuration

uemis CONNECT: Synchronisation of the SDA with myuemis

League Manager Tutorial

LX Compass module 3 Electronic compass device User manual

Horse Farm Management s Report Writer. User Guide Version 1.1.xx

USA Jump Rope Tournament Software User Guide 2014 Edition

Lab 1. Adiabatic and reversible compression of a gas

ELIMINATOR COMPETITION DRAG RACE Program Manual Firm Ver 4.11

WMS 8.4 Tutorial Hydraulics and Floodplain Modeling HY-8 Modeling Wizard Learn how to model a culvert using HY-8 and WMS

Calibration of a GC955

v2.3 USER MANUAL

MASK INTEGRITY TEST ACCESSORY (MITA) MODEL 8120

Online League Management lta.tournamentsoftware.com. User Manual. Further support is available online at

VISIMIX LAMINAR. BLENDING OF NON-NEWTONIAN LIQUID. POWER. CIRCULATION. MIXING TIME.

Hazard Training Guide

Inventory User Guide

Experiment AMe-1: Small Animal Respiratory Exchange Ratio (RER)

CENTER PIVOT EVALUATION AND DESIGN

Lesson: Pitch Trim. Materials / Equipment Publications o Flight Training Manual for Gliders (Holtz) Lesson 4.4 Using the Trim Control.

REASONS FOR THE DEVELOPMENT

Club s Homepage Welcome Club Calendar Logout Add a Request Play Date Requested Time Hole Selection # of Tee Times Break Link

For running only the scoresheet application without any video features only some very basic hardware / software requirements have to be fulfilled:

Tennis...32 Stay above...34 Decimal...36 Bundesliga simulator...38 Shooter management...41 Installation...43 Registration...45 Where do I get the

Wiimote in Physical Etoys

ClubHub. User s Guide

1. SYSTEM SETUP AND START TOURNAMENT... 8

Section 10 - Hydraulic Analysis

Armfield Distillation Column Operation Guidelines

In Response to a Planned Power Outage: PPMS EverCool II Shut Down and Re-start Procedure

KIOSK: SCORE CENTRE USER MANUAL RCGA Network Kiosk: Score Centre User Manual

FIBA Europe Coaching Website. Manual. Practice Section

To Logon On to your tee sheet, start by opening your browser. (NOTE: Internet Explorer V. 6.0 or greater is required.)

English. Golf NAVI. User Guide V1.0.0

JOLLY2. Installation user s manual. 6 different operating modes selectable. version 3.3. DATA TO BE FILLED OUT BY THE INSTALLER (Page 1)

Chapter 7 Single Point Calculations

Operating instructions for. For visualization of your measurements

Oxygen Meter User Manual

SHIMADZU LC-10/20 PUMP

HyperSecureLink V6.0x User Guide

INSTRUCTIONS FOR USING HMS 2016 Scoring (v1)

SwimNumber App. Build Custom Smart Workouts Control the Wave Propulsion TM System Achieve Health and Fitness Goals INSTRUCTION MANUAL

Outside Air Nonresidential HVAC Stakeholder Meeting #2 California Statewide Utility Codes and Standards Program

User Guide. Two-Wheeled Add-on. Created By: A-Lab Software Limited. Date Created: Feb Date Modified: Feb Revision: 1.

Integrated Sports Systems (ISS) Inc. Meet Management Suite

ExcelDerby User's Manual

Software Manual for FITstep Pro Version 2

Operating Manual. BACVis. Manual BACVis. for. Sensors and MilliGascounter. Rev

Operation Manual. rev Pressure Gauges DM-2

Club s Homepage Use this feature to return the club s website.

Transcription:

Manual. NatVent IAQ office ventilation program NaVIAQ V1.3 Delft 1998 October 03 TNO Bouw department BBI by hans phaff 1. Installation Here follows a short description of the installation on a PC with Windows locally installed. Setup will install a number of *.dlls in the windows system directory if no Visual Basic 5.0 program had been installed before. For systems that have Windows shared at a network drive, the systems operator must install the program first to update the system *.dlls. Close all programs, also stop virus checkers that prevent writing in the Windows directories. If earlier versions of NaVIAQ exist, see 1.1. Removal of earlier versions of NaVIAQ. Place the NatVent IAQ CD-Rom or floppy disk 1 in the drive. Open that drive in the Explorer On the CD-Rom open the folder \Design Tools\NavIAQ\Installation files Double click the setup(.exe) program Click OK to confirm that no other programs run. Click the large NatVentIAQ icon. Read further at 2 Run NatVent IAQ. 1.1 Removal of earlier NatVent IAQ versions. From the windows taskbar: Start Settings Control panel Add-Remove Programs. Select NatVent IAQ in the list. Click Add-Remove. There may be an error that the program group NatVent could not be removed. Ignore this. The NaVIAQ icon will stay in the Start Menu until the next boot of the PC. 1.2 Old system files It is possible that the Setup program asks confirmation to replace system files. Setup.lst contains a list of the (dll-)files to be replaced. It may be safe to make a copy of the original files and to run ERD.EXE (see Windows CDROM) before installing NaVIAQ. 2. Run NatVent IAQ. From the windows taskbar click: Start Programs, look for NatVent and then NatVent IAQ in the programs list and click it. Click the Start button or press the Enter key. Manual NaVIAQ page 1

To start a simulation press the Start button at the ventilation frame or /and afterwards the CO 2 button. For help press F1 or open the manual from the menu Help Open manual The tool tips can be switched on/off with the check box in the lower left corner. The name NaVIAQ means Nat Vent Indoor Air Quality. NaVIAQ simulates ventilation flow rates and concentrations of human exhaled CO 2 in one floor of an office building. The program runs best at a screen resolution of 1024*768 or 800*600 16 million colors and small system characters. The program always starts with the input from the last closed run. Manual NaVIAQ page 2

3. Top of the screen. Open/ Save a building file Help and open the manual Number of rooms Also: + or on a 101-key keyboard Pressure/concen tration in the staircase Number of blue rooms. The yellow ones fill the remainder of the corridor Position of windows and doors in the blue rooms Position of windows and doors in the yellow rooms Figure 1 Wind direction The cross section of these rooms is shown at the middle of the screen. The view direction is to the right Leakage and temperature of both staircases At the top of the screen is the menu to open/save the building data, change units and get help and open this manual. The white text boxes (except the one for the number of yellow rooms) can be edited to modify the building. At the left hand side is the floor plan of the office building. The number of rooms (counted along one side of the corridor) is 1 to 50. The two green rooms are shown in detail below as a cross section (90 rotated, viewed towards East). Left and right from the green rooms are the blue and yellow rooms of type 1 and type 2. Those may have different settings for window and door positions (0=closed 100=open). Their input is in the frames with the same color at the right hand side of the floor plan. All other input is copied from the input given for the green rooms shown as cross section in the middle of the screen. The staircase is only simulated at the East side and duplicated in flows and volume to account for the West-staircase. Manual NaVIAQ page 3

4. Middle of the screen. Click at a flow arrow and figure 3 opens Click in a room and figure 4 opens CO2 concentration Blue=outside Red>1500 ppm Figure 2 Expert opinion on a few aspects of the input Change air leakage units Air leakage of the building expressed as the number of air changes per hour at 50 Pa, the so called n50 value Energy by ventilation. The current value is the energy to warm up the ventilation of the two rooms in the cross section. The reference is to warm up 40 dm3/s. This frame can be scaled by dragging the left side The 6 arrows indicate the ventilation flow rates in the cross section of the building. The size of the arrows is the relative size of the flow. During the CO 2 simulation the arrows are colored from blue = Name of the link Position 0=closed 100=open 5 selectable leakage values s for the link in closed position. The flow exponent is a function of the leakage and can t be changed by the user. Area of the ventilation component if it were in full open position (100%). The actual area in the simulation is the product of the here input area and the opening position percentage. Results from the ventilation simulation Figure 3 Limitation of the flow rate to inside (direction of the arrow at start up) and to outside. Switch for the flow controller/limiter Manual NaVIAQ page 4

outside concentration to red=1500 ppm. A click at an arrow yields the input frame of figure 3. The mouse can drag these frames. The top edge border is the best place to drag the frame. You can t drag the frame by clicking on the internal elements(sliders, internal frames and textboxes) The input areas are the free cross section of the openings (opening corrected for frame and grilles, and other obstacles) of a sharp edged opening that would lead to the same capacity (dm 3 /s at 1 Pa). An opening of 12 cm 2 leads to 1 dm 3 /s at 1 Pa. Flow rate (dm3/s) from the ventilation simulation Limitation (dm3/s) of the flow rate to outside in case of a flow controller Limitation (dm3/s) of the flow rate to inside in case of a flow controller Area or free cross section of the ventilation component Name of the room Volume of the room. For the corridor this is the volume per length of a room along the corridor. Input Mechanical supply and extract flow rate Figure 4 This check box controls the display of the area and limits as shown above Figure 5 Output The input for the adjoining blue/yellow rooms of type 1 and 2 are copied from the 6 links in the cross section. However the window and door positions, are taken from the blue and yellow frame, top right. The staircase is derived from the leaks in the room at the same side of the building. The staircase has twice the width of a room. A click at one of the three rooms in the cross section opens figure 5 with : Volume, temperature, mechanical supply and extract flow rates and the number of persons per room. The frame can be dragged at the (top)edge. Manual NaVIAQ page 5

5. Bottom of the screen. Adjust the conditions: 1. drag the slider 2. type a number in the box Start/stop the CO2 simulation. A right mouse click will reset the CO2 concentrations The slider is used to speed up the simulation The elapsed time for ventilation and CO2 It turns red if persons are more than 4 hours inside Start/Stop the ventilation Figure 6 The limits are adjustable: Click and type a number CO2 Simulation without persons Time to stop the CO2 simulation Show leakage and opening areas Show pressures in the rooms Here are controls for: wind speed, wind direction, temperature and outside CO 2 concentration Exit the program, saving the input in the Win registry The minimum and maximum is also adjustable by clicking. This input is not limited and exotic results may follow at odd values. In the frame Ventilation calculation the button Start, starts a series of dynamical calculations of all flow rates and stops at a certain accuracy or 10 simulated seconds. On an average PC the simulation is a few times faster than real time. A second click starts calculations with a greater accuracy. Click Stop to end these calculations at a sufficient approximation of the equilibrium value The total elapsed real time in the building is displayed. The dynamical CO 2 simulation starts at a click at the CO 2 button. The bars show the concentration. The slider (slow.. fast) can speedup the simulation. The number of persons can be set to zero temporarily with a click in the check box (zero persons). If a simulation with persons takes more than 4 hours, the elapsed time will be displayed in a red label to show that normally a break would occur. If the number of persons is set to zero, this red is cleared again. Manual NaVIAQ page 6

6. Step by step After installation click Start Programs NatVent NatVent IAQ. Click OK or press Enter. 6.1 First start Press F1. Click Reset all input. Click OK. Press ESC to return to the NaVIAQ screen. Press S (or click on start in the frame Ventilation calculation) to start the ventilation calculation. This stops at a reasonable value or after 10 s simulation in the office building. Press C (or click on CO 2 in the frame concentration calculation) The simulation does not stop. Press an other time on C or click on CO 2 to stop the calculation. 6.2 Results The ventilation calculations are dynamical. The course of flows and pressures at the indicated time approximates that in the real building. The flow rate is displayed in dm 3 /s, internally mass flow rates are used. The concentrations are calculated for CO 2 which is produced by the persons in the building and depend also on the outside concentration. At the bottom of the cross section is a frame with the heating power. This is the power for two rooms. Calculated from the ventilation heating loss of the whole office building and divided by the number of rooms along one side of the corridor. The heating loss of the staircase is thus added to that of the rooms. Below is as reference the power to warm up 40 dm 3 /s from outside to room temperature. The left edge of this frame can be dragged to be large enough for losses at low outside temperatures up to 9 kw. 6.3 Help text Press F1 to show a short help text. Press ESC to return to the NaVIAQ screen. At the bottom of the help screen is a button to reset all input to the default input. 6.4 Manual At the left below the cross section of the building is a button Manual that opens this manual ( NaVIAQ Manual.doc) if Microsoft Word is present at this PC as WINDOWS program. Search via CTRL+F or the menu Edit Search. 6.5 Check the input Stop the calculations. Press I or click on the button Check the input below the cross section. An overview follows with checks of the input. There may be proposed changes that can be applied automatically with the button at the bottom of this screen Apply changes. This is followed by a new check of the input. Suggested changes to be applied manually are indicated by ***. At dm 3 /s@1pa and g/s@1pa, the reported values may be non integer numbers as they are derived from integer cm 2 values. Press ESC to return to NaVIAQ. 6.6 Edit input of the building Stop all calculations. The ventilation-area of a ventilation component is given here as free area. That is: 12 cm 2 =1dm 3 /s at 1Pa. Most data is limited within a certain range. For instance: room volumes 20.. 200 m 3 air leaks up to 500 cm 2. Manual NaVIAQ page 7

After every change of the input the whole building blower door value, n50 (=number of air changes at 50 Pa) is recalculated. If there are flow controllers n50 is ill defined. At lower pressure flow controller flow rates usually don t decrease. 6.7 Input that is not in the cross section. All non-grayed fields can be edited. 6.8 Clicking on an arrow / ventilation component By clicking an arrow a movable input frame opens Position The most important, most frequently changed data is the opening position of a window/door, which can be changed by the top slider in 5 positions: 0=closed to 100=open. 6.9 Size of the ventilation opening In the second sub frame are the ventilation areas of the components in: closed position (this may be the leak) opened position. The open position is not a large opening, but meant as a provision for ventilation. Real open windows and doors would be in the range of 10000 cm 2. The flow exponent n is here a fixed function of the size of the leak. NaVIAQ does the following: Closed A ventilation component that is closed has only its leak, the area given by the top slider in the ventilation component frame in Error! Reference source not found.. The flow rate is calculated with the displayed flow exponent. mass flow rate = (A leak )*0.63*SQRT(2*rho) * SGN(dp) * ABS(dp) ^ n as shown here: A is in m 2 and the flow rate in kg/s. Opened As soon as the position slider is not closed and in position 20.. 100, the sum of the areas of the leak and the full open area times the position fraction is used with a flow exponent of n=0.5. mass flow rate = (A leak + position / 100 * A fullopen )*0.63*SQRT(2*rho) * SGN(dp) * ABS(dp) ^ 0.5 The abrupt change of the flow exponent, n, may lead to small discontinuities in the actual flow and the n50 value when opening/closing a small window with a large leak. 6.10 Flow controllers In the lower frame is a check box to make the ventilation component a flow controller. The flow rate to inside or to outside can be limited. (interpret to inside as the startup direction of the arrow). Don t zero both limits, as a constant zero flow rate will result. 6.11 Clicking on a room Clicking a room opens a movable input frame with: the volume, the temperature and the mechanical flow rates (see Error! Reference source not found.). 6.12 Changing the Conditions Stop the calculations. The sliders at the bottom of the screen adjust the wind speed, direction, temperature and outside CO 2 concentration. The limits are also editable by clicking. 6.13 Ventilation calculation The following controls also active during a calculation. Manual NaVIAQ page 8

The Check box show area displays the number of cm 2 at all links. Flow controllers also show their limiting values. The Check box room pressure controls the display of the room pressures. CO 2 Concentration calculation. 6.14 CO 2 calculation. The following controls are also active during a calculation. The slider slow..fast can speed up the concentration simulation. The Check box zero persons toggles the number of persons in the whole building to 0 and back to the original number, thus simulating a lunch break. The text box with stop time can be used to stop the CO 2 calculation at a predefined time (hh:mm). An input of zero, like 0:0, is interpreted as :don t stop. A right mouse click on the CO 2 button will zero all CO 2 concentrations. If stopped, the zero concentrations will be shown at the next start. The CO 2 source strength is 5E-6 m 3 /s per person. 7. Compare two versions of a building. NaVIAQ can only work with one building at a time. You may open the program more than once. From the File menu you can open a previously saved building. To start the subsequent run with the current office press F1 and click Save input, after that the building may be changed. The next instance of the program uses the just Saved input. Input is also saved when NaVIAQ is closed. If more than one instance of NavIAQ is running, the last closed one determines the input at a next start of the program. Keep in mind which program is the first on the Windows taskbar. 8. Limitations NaVIAQ is meant to demonstrate office ventilation. Real simulations and design issues would require much more detailed input, such as wind, wind pressures, surrounding buildings, detailed floor plan of the building, other levels. Wind direction is faked by a cosine and will deviate from an actual course. Pressure coefficients are fixed, shielded or exposed buildings must be simulated by an adapted wind speed. The volume of the rooms is limited between 20 and 200 m 3. The flow exponent has a fixed dependency with the input area. For opening positions>0 n=0.5. The flow rates are linearized below 1 Pa. The CO 2 production per person is an average human production value of 5E-6 m 3 /s. The CO 2 concentrations are not calculated if rooms with less than 1.5 dm 3 /s per person exist. The open windows and doors are still small areas, meant as provision for ventilation. They are at 100% open in the program some 20 to 50 times smaller than actual fully opened windows and doors. Manual NaVIAQ page 9

9. Wordlist 1 dm 3 /s flow rate. For one person ventilation flow rates of 7 to 10 dm 3 /s are common. 1 Pa pressure difference of 1 N/m 2 12 cm 2 area for 1 dm 3 /s at 1 Pa 1500 ppm unconfortably high CO 2 concentration, CO 2 bar is red adjacent rooms other rooms along the corridor (blue and yellow) airing Use of large windows to get a large amount of ventilation in a room for a limited period of time, for instance 1 to a few hours per day. arrows ventilation flow rates bars indicate CO 2 concentration blue other rooms along the corridor Check the input button at main screen that opens a form that may have advise on the input and allows for automatic adjustments. climate Meteo outdoor temperature during the year and wind speed CO 2 concentrations the result of human exhalation Delft in dutch the word Delft is related to digging. The main institute of TNO is in Delft. The relation between research and digging duct Pipe though which the ventilation air is supplied or exhausted. dynamical calculations The ventilation and concentrations in this model are simulated as a true function of time and thus dynamical. elapsed real time time elapsed after pressing the start button equilibrium value steady state value extract exhaust F1 open Help F3 Search forward in report and help text F4 Search backwards in report and help text Flow controllers flow exponent devices that keep the flowrate constant Power to which the ratio between two pressure differences across an air leak or opening has to be raised to get the ratio of the flow rates through the air leak/opening at those pressure differences. At laminar flow this exponent is 1, at turbulent flow this exponent is 0.5. There is a relation between the size of leaks, the flow rate and the flow exponent, but this relation has wide deviations for individual leaks. flow rate Air flow rate here expressed in dm 3 /s frame Computer term for a rectangular line. For example the frame that is opened after a click at an arrow or in a room in NaVIAQ. IAQ Indoor Air Quality inlet Opening, grille, flap or device, through which ventilation air can enter the building. This is for purpose provided, more or less continuous inlet of air. In contrast the air that enters through leaks is considered to be unintended or non-purpose provided. Large windows windows with openings in the order of 0.5 to 1 m 2. leak, leakage mechanical ventilation Mechanical meteo conditions n50 Natural ventilation Openings, cracks, joints that are not perfectly air tight through which ventilation air can enter the building. These leaks are notpurpose provided. Ventilation by means of electrical fans. (ventilation) driven by (electrical) fans wind speed, wind direction and outdoor temperature Index for the air leak of the envelope of a building. It is the number of air changes at a pressure difference of 50 Pa across the whole envelope of a building. This is commonly measured by means of a 'blower door'. A large fan placed in an external door or window, to create sufficient over/under pressure. The flow rate (through the fan) is measured and expressed in n50= flowrate*3600/buildingvolume. Ventilation of buildings driven by wind and thermal stack effect (buoyancy) Manual NaVIAQ page 10

natural ventilation Ventilation without systematic use of fans, but mainly by means of wind pressures and thermal stack or buoyancy pressures. NatVent EC program into natural ventilation, giving guidance to overcome barriers NaVIAQ NatVent Indoor Air Quality simulation program for office buildings number of persons the number of persons per room in NaVIAQ number of rooms number of rooms along one side of the corridor pressure in the rooms Pressure in the office(difference with outside) is calculated by the ventilation model. If there are large under- or over pressures a warning is given. If there is mechanical extract ventilation and the leak is set to its minimum and inlets are all closed, then the pressure becomes unrealistically low. Normal fans would not be able to create such pressures, but in NaVIAQ the mechanical flow rate is independent of the pressure. pressure Air pressure difference with the outdoor pressure (without wind pressure) as reference, expressed in Pa (N/m 2 ) show area check box to display the open area of ventilation components (grilles, leaks windows) supply Air supplied by a fan and duct from outside to various rooms of the building. supply flow rate supplied to a room system System for ventilation, consisting of a one or more ducts and one or more fans. A natural ventilation system works without fans, by means of natural wind induced pressures and / or temperature driven pressure differences (buoyancy). temperature (meteo) Outdoor air temperature as given by meteo. text box Computer term for an input box for text or numbers TNO Bouw TNO is a research organisation for Applied Physics in Holland, The institute Bouw (means: Building) is involved in Building and Construction Research ventilation energy Energy used to warm up the ventilation air. ventilation flow rate air flow rate through a building component ventilation model Computer model that calculates the flow rates in a building. This is often done by iterative approximation of the indoor pressures, so that the mass flow rates that enter the building and rooms equal the outgoing flow rates. ventilation system System for ventilation, consisting of one or more ducts and fans could be used. A natural ventilation system works without fans, by means of natural wind induced pressures or temperature driven pressure differences (buoyancy). Ventilation Renewal of indoor air by outdoor air to dilute concentrations of aerosol pollutants like CO 2, H 2 O, odors and to supply O 2. volume Internal volume of the building (m 3 ). wind pressure Pressure on the facade or roof, calculated from the dynamic pressure and the cp value. wind speed wind speed measured at a meteorological station wind Wind speed as given by meteo m/s window Large window used for airing. Manual NaVIAQ page 11