For accurate measurements and to prevent damage to the micropipets, follow these important guidelines:

Similar documents
For accurate measurements and to prevent damage to the micropipets, follow these important guidelines:

For accurate measurements and to prevent damage to the micropipets, follow these important guidelines:

Experiment 1 Use of Micropipettes: measuring volume accurately

MOLEBIO LAB #1: Microquantity Measurement

Lab 1. Instrumentation Familiarity: Using Micropipetters and Serological Pipettes

UNCC Biotechnology and Bioinformatics Camp. Dr. Jennifer Weller Summer 2010

Lab Skills Practice: Pipetting Small Volumes. B3 Summer Science Camp at Olympic High School 2016

Pipetting Small Volumes

Biochemistry Laboratory I CHEM 4401 Pipetting & Scales

Improving Pipetting Techniques

Laboratory #2 Pipetting Technique and Micropipette Calibration Skills=40 pts

Using a micropipette to transfer exact liquid measurements in scientific experiments By: Nicole Hume

Pipetting and Determining Protein Concentration

Gel Loading Practice MiniLab

Real World Metric System

Adjust the Volume Display

How to Use: 1. Hold the pipette like you are going to shake hands with it.

Chapter 2. Pipetting techniques. Guide to Pipetting

How to Measure R7.1. Reference. I. Linear dimensions

Improve pipetting results in pharmaceutical formulation by using MICROMAN E

Operating Instructions. Rainin Classic Manual Pipette

A N F G J I C D D L A B C D E F

Prepared By: Lisa McAvoy 30/Nov/17 dd/mmm/yy. Approved By: Veronica Harris-McAllister 30/Nov/17 dd/mmm/yy

Pipettor. User Manual

Other languages available on our website:

SOP-111 Pipetting Small Volumes

INTRODUCTION TO THE SPECTROPHOTOMETER AND PIPETTING SKILLS

25/04/56. LTC Carmen A. Bell Chief, Laboratory Operations USAMC-AFRIMS

MULTICHANNEL. Labnet International, Inc.

A N B P F G J I C D D L A B C D E F

Inquiry Module 1: Checking the calibration of a micropipette

RayPette Plus Autoclavable Pipette. User Manual

Tips for Proper Pipette handling and Maintenance. D. Muruganand, Ph.D ILQA - Bangalore, Feb 2014

Fisherbrand. Finnpipette INSTRUCTIONS FOR USE PARK LANE Pittsburgh PA

User s Manual. Autoclavable & UV resistant. Multi-channel digital micro pipette. In Vitro Medical Diagnostic Devices (98/79/EC)

The pipettes cover a volume range from 0.1µl to 10ml.

A N B P G J I C D L D E

User s Manual. Digital micro pipette for liquid handling CERTIFIED ISO9001

THE UNIVERSITY OF NEWCASTLE - DISCIPLINE OF MEDICAL BIOCHEMISTRY

SoftGrip Single Channel Pipettes User Manual New Photo To Come

SoCal BioMed, LLC 4695 MacArthur Court, 11th Floor Newport Beach, CA Phone: +1 (424) Fax: +1 (323)

Loopamp Bovine Embryo Sexing Kit Instruction Manual

APPENDIX A CORRECT USE OF DIGITAL PIPETTES

LABORATORY EXERCISE I METRIC SYSTEM OF MEASUREMENT

VOLUMETRIC TECHNIQUES

VWR UHP j :01 Page 1. ENGLISH 1 22 DEUTSCH FRANÇAIS ESPAπOL ITALIANO

Lab Equipment ANALYTICAL BALANCE

II. MATERIALS REQUIRED FOR PERFORMANCE TESTING

CHM250 Calibration and Measurement Lab. Balance Calibration

Transferpette. Single and Multichannel Pipettes

Transferpette. Lightweight precise rugged reliable!

PIPETMAN F ENGLISH. Other languages available on our website:

Transferpette. Lightweight precise rugged reliable!

CALIBRATION AND ADJUSTMENT

Corning Step-R. Repeating Pipettor. Instruction Manual

User s Manual. Autoclavable & UV r e s i s t a n t. Digital micro pipette for liquid handling. In Vitro Medical Diagnostic Devices (98/79/EC)

VIAFLO 96. Electronic 96 Channel Hand Held Pipettor

LABORATORY TECHNIQUES. Pouring Liquids

Transferpette. Testing Instructions (SOP) 1. Introduction. October 1998

MICROMAN ENGLISH. Other languages can be consulted and downloaded on our website,

Basic Flows in a Microfluidic Device

Technical Procedure for General Laboratory Equipment

NEO. User s Guide. Do not lubricate this pipette. The use of lubricant cancels the warranty of this pipette. NOTICE

Nichipet EX Plus II. User s Manual. Autoclavable & UV resistant. Digital micro pipette for liquid handling

Userts Manual. Digital micro pipette for liquid handling. In Vitro Medical Diagnostic Devices (98/79/EC) Annex III self-declared ISO 8655 STANDARD

Measuring Mass and Volume

User s Manual. Autoclavable & UV resistant Nichipet EX II. Digital micro pipette for liquid handling. In Vitro Medical Diagnostic Devices (98/79/EC)

Ammonia Treatment Instructions Page 1 of 5

Picus NxT Electronic Pipettes Ergonomic, Efficient, & Safe

Transferpette. Testing Instructions (SOP) 1. Introduction. May 2009

Objective To identify a pure liquid substance using the physical properties of solubility, density, and boiling point.

Transferpette -8/-12

1.0 PURPOSE The purpose of this procedure is to describe the use of basic aseptic technique.

Measurements. Metric System

OXYTEMP Instructions 1

Patients Guide for Self Administering Intravenous Antibiotics General points

MSD 96-Well MULTI-ARRAY and MULTI-SPOT Human Granulocyte Colony Stimulating Factor (hg-csf) Ultrasensitive Assay

SOP for use of the SX19 Stopped-Flow Instrument

Douglas Call 4/11/2008 1/5. Ammonia Treatment

VWR HIGH PERFORMANCE PIPETTOR

Varipette Operating manual

Clean toilet plunger Sensor extension cable. Add this important safety precaution to your normal laboratory procedures:

THE UNIVERSITY OF NEWCASTLE - DISCIPLINE OF MEDICAL BIOCHEMISTRY

Gas Laws: Boyle s and Amonton s Laws Minneapolis Community and Technical College v.9.08

Eppendorf Research fix variable multi Instruction Manual Bedienungsanleitung Mode d emploi Instruzioni d impiego Manual de Instrucciones

Students measure the change in pressure by varying the volume of trapped air in a syringe while:

User's Manual. Autoclavable Nichipet EX Plus Digital micro pipette for liquid handling CERTIFIED ISO9001

WITOPET PREMIUM PIPETTE USER S GUIDE

Good Pipetting Practice

BIOSAFETY SELF AUDIT PRINCIPAL INVESTIGATOR/PERMIT HOLDER: CONTAINMENT LEVEL: 1 2 (Shaded) RISK GROUP: 1 2 AUDIT TO BE COMPLETED BY (DATE):

Experiment #2. Density and Measurements

Pulmonary Function I (modified by C. S. Tritt, April 10, 2006) Volumes and Capacities

The use of the analytical balance, and the buret.

UNIT PLAN. Grade Level: 3 Unit #: 4-2 Measurement: Length, Volume, Mass, & Equivalencies

Air Displacement Pipetting Modules. Total Integrated Liquid Handling

STANDARD OPERATING PROCEDURE VORTEX-GENIE 2

Standard Operating Procedure. Air Displacement Pipette Calibration

User s Guide VARIABLE VOLUME MODELS. Variable volume single and multichannel models and fixed volume models

DISCOVERY PRO - features

Experiment 18 Properties of Gases

Transcription:

ULSTER AND RAININ VERSION MEASURE FOR MEASURE MICROIETTING AND THE METRIC SYSTEM Concept: Work with DNA and enzymes frequently involves measuring very small volumes, often in the microliter range. A microliter (µl) is one millionth of a liter. Liquid measurements in the metric system are made in units based on the liter where a liter is about one quart. To make these precise measurements, molecular biologists use a precision tool known as a micropipet. This tool is as basic to their lab work as a hammer is to a carpenter. Micropipets come in many models and sizes. You will be using micropipets similar to those found in the Fred Hutchinson Cancer Research Center research labs. Objectives: In this lab, you will learn to use micropipets accurately and to measure volumes using metric units including microliters. Mastery of this technique is essential for good results in the activities to follow. Use the following information to calculate metric volume conversions. liter = 000 ml (milliliters) ml = 0.00 liter liter =,000,000 microliters microliter = 0.00000 liter microliter = µl = (in lab jargon) lambda (λ) For accurate measurements and to prevent damage to the micropipets, follow these important guidelines: Set the volume only within the range of your micropipet. Have the proper size disposable tip in place on your micropipet before immersion into any solution. Always keep the micropipet in a vertical position when there is liquid in the tip. In a horizontal position, fluid can leak back into the piston. Use your thumb to control the speed at which the plunger rises after taking up or ejecting liquid. Letting the plunger snap back damages the piston and the volume dispensed may be inaccurate.

SETTING AND REARING THE MICROIET There are four common sizes of micropipets. See the guide below for these sizes and volume ranges.. Choose a micropipet and set the volume by rotating the black volume adjustment knob. Make sure to recognize the decimal point for your micropipet (indicated by the in the table below) and to stay within the volume range. Range is on top of the plunger volume adjustment knob 2. Using the guide below, select the correct tip for your micropipet. Firmly push the end of the micropipet into the open end of the tip while the tip is still in the tip box. (Avoid twisting the micropipet as this can unscrew the shaft.) Lift the tip from the box, but don t touch the tip near the smaller end. Touching the tip contaminates it and will contaminate your samples. Refer to the rotocol Card for more information Ulster and Rainen Micropipet and Tip Guide Size Range Top view and Color Ulster Rainen Example Setting Tip size and color Tip sample -0 0.-0 µl 0. 0 white 0 silver 0 6 6. µl micro white - 2- µl 2 yellow yellow 7 8 7.8 µl medium white or yellow - - µl gold yellow 0 0 µl -000-000 µl 000 blue 000 blue 0 6 7 670 µl or 0.67 ml decimal point large white or blue 2

OERATING THE MICROIET. Find the stops Hold the micropipet in your hand. Use your thumb to depress the plunger. ractice slowly depressing the plunger and feeling the two stops. 2. Draw some sample fluid from your microtube ush the plunger knob down to the first stop. Keeping the plunger down, lower the tip into the sample fluid just below the surface (~2 to 3mm). Gradually release the plunger. Do this slowly to avoid sucking liquid inside the shaft of the pipet. After filling, wait second then remove tip from liquid. 2 3. Check the tip of the pipet See how much fluid you have. Make sure that there are no air bubbles trapped in the tip. If so, redraw the sample. Make sure that there are no drops clinging to the outside of the tip. 4. Release the fluid from the pipet Lower the tip into the microtube and lightly touch the side or bottom of the tube. Slowly depress the plunger to the first stop. Wait second, then push plunger to the second stop to expel the last bit of fluid so that the pipet tip has no fluid left in it. Keep the plunger pushed down as you take the pipet out of the tube, then slowly release the plunger. 4. Eject the tip into a waste tip container by pushing the tip ejector button. Viscous fluids: If you are pipetting a liquid that is very thick or viscous (such as sample loading buffer or restriction enzymes--both contain glycerol or ficoll), it is especially important to insert the disposable tip just into the liquid that you are measuring (say 2 mm). If you immerse the tip fully, large volumes of liquid will stick to the outside of the tip giving you a very inaccurate measurement. With viscous solutions, it is also important to move the plunger up and down slowly. Being able to do this makes you a real pro! 3

. Metric conversions: complete the following a. ml = microliters d. µl = ml b. 0 microliters = ml e. µl = ml c. 00 microliters = ml f. 2 ml = µl 2. ut the following volumes in order from largest to smallest. a. 2. ml, 20 µl, 0.02 ml, 2. µl,,, b. 00 µl, 0.0 ml, 20 µl, 0.0 ml,,, 3. Explain the reason for each of the following rules: a. Always use the micropipet within its designated range: MEASURE FOR MEASURE STUDENT WORKSHEET b. Always use a disposable tip on a micropipet: c. Always hold a loaded micropipet in a vertical position: d. Always release the micropipet plunger slowly: 4. Under each micropipet, indicate the size of the micropipet, the set volume and the range for that micropipet (the first one is filled out as an example). 2 000 0. 0 0 0 0 3 0 2 Size (-?) -000 Volume shown: 0 µl : Range: 000 µl 4

. Select the appropriate micropipet and show what the dial should read to measure each of the following volumes: 0 µl,. µl, 300 µl, and 7.3 µl. Also write the amount on the line beneath each drawing. 2 000 0. 0 6. Volume comparisons ractice measuring,, 0,, 00, and 00 µl. On a piece of waxed paper or arafilm release the drops and visually compare the sizes. Draw the actual size of each droplet on the chart below. (If you wet the lab table before setting the waxed paper down, the paper will not curl up as much.) Work on your technique. Be smooth. Try to pick up and dispense the same drop several times.0 µl.0 µl 0.0 µl.0 µl 00 µl 00 µl 7. ut one drop from an eyedropper or plastic transfer pipet on the piece of wax paper away from your other drops. Estimate its size in µl.

You will use the centrifuge during the exercise in question 0. Review centrigfuge use below. Microcentrifuge instructions: Close the caps on the tubes. The rotor must always be balanced you cannot, for example, insert only one tube into a microcentrifuge (microfuge). Spinning in an unbalanced arrangement like this would damage the motor of the instrument. Use an extra balance tube if necessary. After you have closed the lid of the centrifuge, give the tubes a -3 second spin. This will mix and pool all the reagents into a droplet in the bottom of each tube. Wait for the rotor to stop before opening the centrifuge lid. 8. Why is it important to balance a centrifuge before turning it on? 9. Show how you would arrange the given number of tubes in each centrifuge to balance the load. If you decide that you must add or remove tubes, explain this below the diagram. a. 3 tubes b. 4 tubes c. tubes d. 0 tubes e. tubes 0. Measurement Matrix Label three empty microtubes A, B, and C, with a permanent marker pen. Add solutions I, II, III, and IV to tubes A-C as shown in the matrix. To help you stay organized and prevent cross contamination, after pipetting each liquid place a check mark next to that space on your chart. Always use a new tip for each new liquid being added to the tubes or when adding a new liquid to a tube already containing some. Micropipet Matrix Tube Micropipet Solution I Solution II Solution III Solution IV Total A -0.8 µl 4. µl 3.7 µl 0 9.6 µl B - 3.4 µl 0 2.6 µl 2 µl 8 µl C - 0 µl 42 µl 0 0 µl 97 µl Spin the tubes in the microcentrifuge (microfuge) for a few seconds to pool the solutions. Get help from your teacher and review centrifuge instructions above. As a check of your pipetting accuracy, do the following exercise. Set the -0 to 9.6 µl. Slowly attempt to suck in all of the fluid in tube A. The contents should just fill the tip--no air space at the bottom of the tip, no leftover fluid in the tube. Repeat with tube B and the - (total 8 µl) and with tube C and the - (total 97 µl). 2. If practice agarose gels are available: Load µl from tubes B and C and all of tube A into separate wells. Estimate how much fluid gel wells hold after you have loaded your µl sample. 6