M45 ISO Ball Valve DN25 to 150 Installation and Maintenance Instructions

Similar documents
A3S Bellows Sealed Stop Valve Installation and Maintenance Instructions

TD45 Thermodynamic Steam Trap Installation and Maintenance Instructions

M33F ISO, M33S ISO and M33V ISO Ball Valves Installation and Maintenance Instructions

AVS32 Stainless Steel Air Vent for Steam Systems Installation and Maintenance Instructions

KBV21i and KBV40i Air Actuated Boiler Blowdown Valves

SCA Series Inverted Bucket Steam Traps

KBV21i and KBV40i Key Operated Boiler Blowdown Valves Installation and Maintenance Instructions

FT16 Ball Float Steam Trap Installation and Maintenance Instructions

Fig 1, Fig 12, Fig 13, Fig 14, Fig 16 and Fig 16L Strainers Installation and Maintenance Instructions

Thermocirc Installation and Maintenance Instructions

BSA6T and BSA64T Stainless Steel Bellows Sealed Stop Valves Installation and Maintenance Instructions

CA16 and CA16S-14 Air and Gas trap Installation and Maintenance Instructions

BTD52L Thermodynamic Steam Trap Installation and Maintenance Instructions

M10HTi ISO Tobacco Ball Valve Screwed, SW, BW and Flanged versions

TD10, TD52M and TD259 Thermodynamic Steam Traps Installation and Maintenance Instructions

USM21 Sealed Bimetallic Steam Trap for use with Pipeline Connectors Installation and Maintenance Instructions

PV4 and PV6 Piston Valves

UBP32 Sealed Balanced Pressure Thermostatic Steam Trap for use with PC_ Pipeline Connectors Installation and Maintenance Instructions

AE50S Automatic Air and Gas Vent for Liquid Systems Installation and Maintenance Instructions

1. General safety information. 2. General product information. 3. Installation. 4. Commissioning. 5. Operation. 6. Maintenance. 7.

M70i ISO and M80i ISO Stainless Steel Ball Valves for Sanitary Systems Installation and Maintenance Instructions

FTGS14 Ball Float Steam Trap DN15 (½") to DN25 (1")

Fig 1, Fig 12, Fig 13, Fig 14HP, Fig 16, Fig 16HP and Fig 16L Strainers

AVC32 Carbon Steel Air Vent for Steam Systems

Fig 12, Fig 14HP, Fig 16, Fig 16HP and Fig 16L Strainers

Spiratec ST14, ST16 and ST17 Sensor Chambers and sensors

HM and HM34 Inverted Bucket Steam Traps Installation and Maintenance Instructions

MST21 Stainless Steel Balanced Pressure Thermostatic Steam Trap

TA10A and TA10P Steam Tracing Temperature Control Valves Installation and Maintenance Instructions

IFTGS14 Ball Float Steam Trap ½" and ¾" with Integral Spiratec Sensor

MSC-P and MSC-N Manifolds for Steam Distribution and Condensate Collection

CA10S, CA14 and CA14S Air and Gas Traps

Manual Actuated Boiler Blowdown Valves

DF1 and DF2 Diffusers

S1, S2, S3, S5, S6, S7, S8, S12 and S13 Separators

CA44, CA44S, CA46 and CA46S Air and Gas Traps

Fig 3, 7, 33, 34, 34HP, 36, 36HP, 37, 3616 and Fig 3716 Flanged Strainers

Dri-Line Mk3 Monnier Compressed Air Drain Trap

DCV10 Stainless Steel Disc Check Valve for use with Condensate Pumps

Fig 7, 33, 33.1, 34, 34HP, 36, 36HP, 37, 3616 and Fig 3716 Flanged Strainers Installation and Maintenance Instructions

DCV1, DCV3 and DCV3LT Disc Check Valves Installation and Maintenance Instructions

Dri-Line Mk2 Spirax-Monnier Compressed Air Drain Trap

AE14 Automatic Air Vents for Liquid Systems Installation and Maintenance Instructions

PC3_ and PC4_ Pipeline Connectors

TDC46M, TDS46M and UTDS46M Thermodynamic Steam Traps with Maintainable Seat Installation and Maintenance Instructions

APT14, APT14HC and APT14SHC Spares 2

TD62LM and TD62M Thermodynamic Steam Traps with Replaceable Seats

S1, S2, S3, S5, S6, S7, S8, S12 and S13 Separators Installation and Maintenance Instructions

Spirax SafeBloc TM DBB3 Double Block and Bleed Bellows Sealed Stop Valve. 1. Safety information. 2. General product information. 3.

S and SF Inverted Bucket Steam Traps

UIB30 and UIB30H Sealed Inverted Bucket Steam Traps for use with Pipeline Connectors

CP10 Sensor Installation and Maintenance Instructions

TP1 and TP2 Temporary Cone Shaped Strainers

BCV31 DN40 - Blowdown Control Valve

AVM7 Stainless Steel Thermostatic Air Vent

BCV31 DN20 - Blowdown Control Valve

TSS21 Sealed Thermostatic Steam Tracer Trap

CS10-1 Stainless Steel Clean Steam Separator

MF2M Monnier Miniature Compressed Air Filter

BTM7, BTS7 and BTS7.1 Stainless Steel Thermostatic Clean Steam Traps

BT6HC Hygienic Sanitary Balanced Pressure Steam Trap for High Capacity and CIP/SIP Applications

DCV6 Disc Check Valve

SRV66 Sanitary Pressure Reducing Valve

FT53, IFT53, FT54, IFT54, FT57 and IFT57 Ball Float Steam Traps - DIN

Airodyn, BRair and BRoil Compressed Air Drain Traps

TD62LM and TD62M Thermodynamic Steam Traps with Replaceable Seats Installation and Maintenance Instructions

IX1 Spirax-Monnier International Compressed Air Filter Installation and Maintenance Instructions

AE30 Automatic Air Eliminators / Air and Gas Vents for Liquid Systems

CVS10 Sanitary Check Valves

SA Control Valve types: BM, BMF, BX, SB, NS, KA, KB, KC (Normally open) BMRA, BMFRA, BXRA, SBRA, NSRA, KX, KY (Normally closed)

BDV1 and BDV2 Blowdown / Depressurisation Valves

SRV2S Pressure Reducing Valve

FT43, FT44, FT46 and FT47 Ball Float Steam Traps Installation and Maintenance Instructions

BRV71 and BRV73 Pressure Reducing Valves

ML3M Monnier Miniature Compressed Air Lubricator

TW Temperature Control Valve

CA46S Austenitic Stainless Steel Air and Gas Trap DN40 and DN50

FTC62 and FTS62 Ball Float Steam Traps Installation and Maintenance Instructions

BPT13 Balanced Pressure Thermostatic Steam Traps

BSA and BSAT Bellows Sealed Stop Valves Installation and Maintenance Instructions

FV Flash Vessel Installation and Maintenance Instructions

CA44 and CA44S Carbon Steel Air and Gas Traps Flanged DN15 to DN25

Spirax Compact FREME Flash Recovery Energy Management Equipment

BT6-B Sanitary Balanced Pressure Thermostatic Steam Trap

MFP14-PPU (Vented) Automatic Packaged Pump Units

PC3000, PC3001 and PC4000, PC4001 Pipeline Connectors

SV5 Safety Valve Installation and Maintenance Instructions

PC10HP Pipeline Connector (ASME 600)

SA121, SA122, SA123, SA128 and SA1219 Self-acting Temperature Control Systems (Knob Adjustment)

QuickHeat TM Packaged Heat Exchanger Solutions

SA121, SA122, SA123, SA128 and SA1219 Self-acting Temperature Control Systems (Dial Adjustment)

Engineering Data Sheet

CA14 SG Iron Air and Gas Trap ½" and ¾" (Screwed)

SRV461S and SRV463S Stainless Steel Direct Acting Pressure Reducing Valves

595-K/L and 596-K/L Series Self Operated Valves Installation and Maintenance Instructions

1. Preface Important Safety Notes Brief Product Information Product Working Principle Installation Guidelines...

STERI-TROL Clean Service 'S' Series Two-port Control Valves DN15 (½") to DN100 (4")

MPC1M, MPC2M and MPC2AM Monnier High Efficiency Compressed Air Filter / Regulators

RJ check valves Installation and Maintenance Instructions

M111 Spiraflo Transducer

Transcription:

BAC 13310 IM-P133-42 ST Issue 2 M45 ISO Ball Valve DN25 to 150 Installation and Maintenance Instructions 1. General safety information 2. General product information 3. Installation 4. Commissioning 5. Operation 6. Maintenance 7. Spare parts Printed IM-P133-42 in the ST UK Issue 2 Copyright 20031

1. General safety information Safe operation of the unit can only be guaranteed if it is properly installed, commissioned and maintained by a qualified person (see Section 11 of the attached Supplementary Safety Information) in compliance with the operating instructions. General installation and safety instructions for pipeline and plant construction, as well as the proper use of tools and safety equipment must also be complied with. Isolation Consider whether closing isolating valves will put any other part of the system or personnel at risk. Dangers might include; isolation of vents and protective devices or alarms. Ensure isolation valves are turned off in a gradual way to avoid system shocks. Pressure Before attempting any maintenance consider what is or may have been in the pipeline. Ensure that any pressure is isolated and safely vented to atmospheric pressure before attempting to maintain the product, this is easily achieved by fitting Spirax Sarco depressurisation valves type DV (see separate literature for details). Do not assume that the system is depressurised even when a pressure gauge indicates zero. Temperature Allow time for temperature to normalise after isolation to avoid the danger of burns and consider whether protective clothing (including safety glasses) is required. Disposal The product is recyclable. No ecological hazard is anticipated with the disposal of this product providing due care is taken. 2 IM-P133-42 ST Issue 2

2. General product information 2.1 General description The M45 ISO is a flanged reduced bore single piece ball valve with metal seats. This makes it suitable for working with fluids that contain solids in suspension, high temperature fluids and flow control applications. The valve has an ISO mounting making it easy and safe to automate. ISO mounting The integral ISO body mounting allows the valve to be automated without losing seal integrity, as the body does not require disassembly. Manual to remote control may therefore be safely and easily accomplished by the ISO range of Spirax Sarco ball valves. Available types M452V ISO Zinc plated carbon steel body, Viton 'O' ring. M452K ISO Zinc plated carbon steel body, Kalrez 'O' ring. M453V ISO Stainless steel body, Viton 'O' ring. M453K ISO Stainless steel body, Kalrez 'O' ring. Note: For additional information see the following Technical Information Sheets: TI-P133-47 and TI-P133-48. 2.2 Sizes and pipe connections DN25, 40, 50, 65, 80, 100 and 150. Flanged ANSI 150 and ANSI 300. Fig. 1 M45 ISO ball valve IM-P133-42 ST Issue 2 3

2.3 Limiting conditions Body design conditions According to BS 5351 Maximum operating temperature Maximum operating pressure (MOP) Maximum saturation steam pressure Temperature C 300 A B C 250 F 220 E G Steam saturation curve 150 100 50 0 0 5 10 15 20 21 Pressure bar g E-F-H ANSI 150 Viton E-G-D ANSI 300 Viton A-B-H ANSI 150 Kalrez A-C-D ANSI 300 Kalrez M45V M45K M45V M45K Designed for a maximum cold hydraulic test pressure of 1.5 x MOP 2.4 Operating range ANSI 150 ANSI 300 ANSI 150 ANSI 300 H D 220 C @ 12 bar g 220 C @ 21 bar g 300 C @ 9 bar g 300 C @ 21 bar g ANSI 150 19 bar g @ 38 C ANSI 300 21 bar g @ 220 C ANSI 150 19 bar g @ 38 C ANSI 300 21 bar g @ 300 C ANSI 150 ANSI 300 13 bar g 21 bar g 4 IM-P133-42 ST Issue 2

3. Installation Note: Before actioning any installation observe the 'Safety information' in Section 1. Although the valve has great structural integrity, severe misalignment and/or the pulling effect of incorrect pipe length will have a detrimental effect on the valve and must be avoided. Particular attention should be paid to correct pipe alignment such that the inlet pipework and valve are all on the same axis. Valves are for both on/ off and control applications and may be installed with flow in either direction. Wherever practicable, valves should be installed where there is adequate space available so that they can be conveniently operated and maintained. Before installing a valve, check to ensure that size, pressure rating, materials of construction, end connections, etc. are suitable for the service conditions of the particular application. Care must be taken to ensure that all dirt which may have accumulated in the valve during storage is removed before installation, maintain cleanliness during installation since the introduction of dirt can result in damage to the valve seats and operating mechanism. To minimise the danger of abrasive particles damaging the seats, pipeline strainers should be fitted upstream of the valves. Install the valve with the handle in a suitable position. The preferred position is with the spindle vertical. The valve can be installed from the vertical to the horizontal plane (see Fig. 2 below). Do not mount the valve upside down (Fig. 3). 7 3 When Fig. 2 Correct installation Fig. 3 Incorrect installation installed on steam systems a suitable steam trap should be fitted immediately upstream of the isolation valve. This will ensure drainage of the pipe when the valve is closed, and will prevent damage of the valve due to waterhammer. The drain trap should be either a ball float (FT) or thermodynamic (TD) type. Correct condensate drainage of all upstream pipework is also vital. Valves should be installed into the pipeline in the fully closed position. Always open valves slowly to avoid system shocks. IM-P133-42 ST Issue 2 5

4. Commissioning After installation or maintenance ensure that the system is fully functioning. Carry out tests on any alarms or protective devices. 5. Operation The valve is operated manually by a handle, or automatically by an actuator. Special care must be taken to ensure that the movement is made in the correct direction. The valve can be used as an on/off or a modulating flow control valve, and can be operated fully open, fully closed, or at any point in between. 6. Maintenance Note: Before actioning any maintenance programme observe the 'Safety information' in Section 1. 6.1 General information As with all mechanical devices, regular maintenance is the most efficient means of ensuring continued operational efficiency. Regular scheduled inspection of all valves is essential especially on valves which are operated only occasionally. 6.2 General maintenance When the seats (5) are replaced and the valve is reassembled it is advisable to conduct a hydraulic test to the body at 30 bar g and a seat leakage test using compressed air at 7 bar g. Note: A special tool is required in order to remove the insert (2). This tool is only available from Spirax Sarco. 6.3 To replace the main stem seals, seats and ball: 1. Remove the valve from the pipeline. 2. Using the special tool: which is available from Spirax Sarco, unscrew the insert (2) 3. It is now possible to remove the seats (5) the 'O' rings (17) and the ball (3). Withdraw the stem (4) and replace the main stem seal (6A). 4. Reassemble the M45 ball valve. 5. Ensure that a PTFE based sealant compound is applied to the thread of the insert (2). 6. The insert (2) should be tightened to the recommended torque. See Table 1 opposite. 7. After 24 hours in service, retighten body bolts. 6.4 To replace the secondary stem seals: 1. Remove nuts (9 and 9A). 2. Replace the stem seals (6 and 18). 3. Reassemble the M45 ball valve. 4. After 24 hours in service, retighten body bolts. Note: If leakage is observed through the stem it may be stopped by tightening the gland nut (9A) without requiring the replacement of stem seals. 6 IM-P133-42 ST Issue 2

9 9A 6A 18 6 2 4 Fig. 4 17 5 3 5 17 Table 1 Recommended tightening torques Item no. Part Size N m (lbf ft) DN25 108-135 (79-99) DN40 135-160 0(99-118) 2 Insert DN50 215-245 (158-180) DN65 245-270 (180-199) DN80 405-605 (298-446) DN100 540-740 (398-545) DN150 1 000-1 200 (737-885) DN25 - DN65 34-41 (25-30) 9A Gland nut DN80 40-47 (29-34) DN100 54-61 (39-45) DN150 196-216 (144-159) IM-P133-42 ST Issue 2 7

7. Spare parts The spare parts available are shown in heavy outline. Parts drawn in broken line are not supplied as spares. Available spares Ball 3 Seat, stem seal set and 'O' ring 5, 6, 17, 18 Special tool (not shown) for the removal of insert (2) How to order spares Always order spares by using the description given in the column headed 'Available spares' and state the size and type of ball valve. Example: 1 - Seat, stem seal set and 'O' ring for a DN50 M452V ISO ball valve. 6 18 6 17 5 3 5 17 Fig. 5 8 IM-P133-42 ST Issue 2