V311. Venta. Three-way Plug Valve, Flanged PN 16

Similar documents
3-way control valves VK 3

Seated valves (PN 6) VL 2 2-way valve, flange VL 3 3-way valve, flange

Seated valves (PN 16) VF 2 2-way valve, flange VF 3 3-way valve, flange

BTV. Internally threaded 2-way control valve. Flow characteristics. Function

Seated valves VRB 3, VRG 3

Seated valve for steam (PN 25)

2-port and 3-port seat valves, PN16

Seated valve for steam (PN 25) VFS 2 2-way valve, flange

MZX. Three-Port Seat Valves SPECIFICIATIONS AND GUIDE TO SELECTION

Pressure balanced valves (PN 25)

2-Port and 3-Port Seat Valves with Female Thread, PN16

Pressure reduction controller (PN 16, 25, 40)

Pressure Independent Control Series

2-Port Seat Valves with Flange, PN 16

3-port seat valves with externally threaded connection, PN 16

2-port and 3-port valves PN 16

Differential pressure controller (PN 25) AVP - return and flow mounting, adjustable setting

VB-7212 Series. Application. Features. Applicable Literature. 5/8" O.D., 45 SAE Flared Stem Up Open, Two-Way Valves General Instructions

Pressure balanced valves (PN 25) VM 2 2-way valve, external thread VB 2 2-way valve, flange

2-port seat valves PN25 with externally threaded connections

Versions. Benefits. Balancing DN15-32 DN40 DN50 DN15, DN20, DN25, DN32, DN40, DN50. Dimensions

2-Port Seat Valves with Flange, PN 16

VZL valve - 2/3/4-way

2 - way valve for steam, pressure relieved (PN 25) VGS - external thread

2 - way valve (NO) for steam, pressure relieved (PN 25) VGS - external thread

Differential pressure and flow controller (PN 16) AVPQ - return mounting, adjustable setting

VB-7211 Series. Application. Features. Applicable Literature. 1/2" to 1-1/4" Union End NPT Stem Up Open, Two-Way Valves General Instructions

Pressure independent control valve (PICV) FLOWMATIC

AVP-F. p setting range (bar) Code No. 003H6200

NAF-Trimball Control Ball Valves

VB-7213 Series. Application. Features. Applicable Literature. 1/2" to 2" Screwed NPT Stem Up Open, Two-Way Valves General Instructions

Three-port valves. Special versions with special stem sealing gland for: High temperature hot water C Thermo oils

Two-port seat valves

VBGx-xx-xx Externally Threaded Control Ball Valves PN25 (DN15 TO DN32)

TA-FUSION-P. Combined control & balancing valves Pressure independent combined balancing and control valves with independent EQM characteristics

VBGx-xx-xx Externally Threaded Control Ball Valves PN25 (DN15 TO DN32)

PRESSURE REDUCING VALVE RP45 (EN)

Differential pressure controller (PN 16) AHP - return mounting, adjustable setting

Simple Set Max. Pressure Independent Control Valves 2 Way 2-1/ /09/18

Installation, commissioning and servicing instructions

Two-port valves, male threaded, PN25

VBS-9263 Series. Application. Features. Applicable Literature

Products no longer available

The valves are used in combination with AMV(E) 130/140, AMV(E) 130H/140H and AMV(E) 13 SU actuators. DN k VS

Series 42 Self-operated Regulators Differential Pressure Regulators with Type 2424/Type 2428 Actuator (closing) Type Type 42-28

Technical data sheet. Type overview. Technical data. Safety notes. T5-R2.. Open-close en v Subject to changes 1 / 3

VB-7263 Series. Application. Features. Applicable Literature

VB-7323 Series. Application. Features. Applicable Literature. 1/2 to 2 Screwed NPT Three-Way Diverting Valves General Instructions

STAD-D. Balancing valves Balancing valve for domestic water systems, DN Balancing valves

Overview of types. Technical data. Safety notes

DS MZ, MZF, MJF THREE-PORT SEAT VALVES

VB-7273 Series. Application. Features. Applicable Literature

Differential pressure controller with flow limitation (PN 16, 25, 40) AFPB / VFQ 2(1) AFPB-F / VFQ 2(1)

Ballorex Dynamic Description. Versions. Benefits. Balancing

TA-FUSION-P. NPT threads / ANSI flanges

CALEFFI. Pre-adjustable pressure reducing valves with self-contained cartridge series 01085/17 GB. replaces 01085/14 GB

Installation, commissioning and servicing instructions

Pressure reducing valves Index

TBV-CM. Combined control & balancing valves for small terminal units For modulating control

Technote. Frese PV-SIGMA Compact Dynamic Pressure and Flow Regulation. Description. Application. Operation. Features. Benefits.

HERZ - Compact Flow Controller with

STAP. Differential pressure controllers DN , ANSI fl anges

Technote. Frese PVS - Dynamic Pressure and Flow Regulation Valve. Application. Features. Benefits.

Overview of types. Technical data

The valves are used in combination with AMV(E) 130/140, AMV(E) 130H/140H and AMV(E) 13 SU actuators. DN k VS

STA. Double regulating valves DN 15-50

Automatic Balancing Valve Pressure difference controller with integrated flow limiter AB-PM DN

TA-Modulator. Combined control & balancing valves for small terminal units Pressure independent balancing and control valve for modulating control

Mounting and Operating Instructions EB 3007 EN. Self-operated Pressure Regulators. Differential Pressure Regulators (opening) Type Type 42-25

Overview of types. T5-R B2/R B2 en v Subject to changes 1 / 4. k vs (Sequence 2)

Differential Pressure Regulator Type Type 45-6 (0.1 to 1 bar, DN 15) Mounting and Operating Instructions EB 3226 EN

Rp [ ] Sv min. [ ] C215QP-B 15 1/ C215QP-D 15 1/ C220QP-F 20 3/ [ ]

Valves for Biogases and Recycling Gases

Differential Pressure Control Valve (DPCV)

VGG... VGF... VGH... Gas Valves. Building Technologies HVAC Products VGG... VGF... VGH...

Type overview. R B2 en-gb subject to changes 1

CAST IRON SAFETY VALVE TYPE 6301

TECHNICAL CATALOGUE PRESSURE REDUCING VALVES EUROPRESS

STA. Double regulating valves DN 15-50

VG3000. Globe Valves Series for Terminal Units. Product Bulletin. 2-way PDTC (NO) with 6 bar close off pressure. Extend range of K VS

VG3000. Globe Valves Series for Terminal Units. Product Bulletin. 2-way PDTC (NO) with 6 bar close off pressure. Extend range of K VS

A t. VB-7323 Series. Application. Features. Applicable Literature. l/2 to 2 Screwed NPT SIEBE

PRESSURE REDUCING VALVE RP45 (ANSI)

Mounting and Operating Instructions EB 2555 EN. Self-operated Pressure Regulators. Pressure Reducing Valves Type 50 ES Type 50 EM.

STV / STVL. Danfoss STV series of balancing valves provide testing and balancing of circuit flow for hydronic heating or cooling systems.

Pressure Reducing Valve for Steam Type 2333 A

CALEFFI. Ball zone valves. series /03 GB

DS MB, MBF THREE PORT VALVES

E 328 E 498 Tank top mounting Connection up to G1½ / -24 SAE and SAE 2 Nominal flow rate up to 600 l/min / gpm

Pre-adjustable pressure reducing valves with self-contained cartridge

HYDRAULIC CONTROL VALVES

kyone for All - Unique Mixproof

Pressure Reducing Valve for steam RP 45

Pressure and Flow Control Valves DBGM, German and European Patents

Self-operated Pressure Regulators Type Universal Pressure Reducing Valve

Full Range Pressure Compensating Variable Flow Control

Ball Float Steam Trap UNA 45 MAX, UNA 46 MAX, UNA 46A MAX PN 40/Class 300 DN 40, 50, 65

Differential pressure controller (PN 16) AVPL return mounting, adjustable setting

STAP. Differential pressure controllers DN , ANSI flanges

Series 44 Self-operated Pressure Regulators. Type 44-0 B Pressure Reducing Valve. ANSI version

Transcription:

1 Three-way Plug Valve, Flanged PN 16 can be used in a wide range of applications, such as heating, cooling, air handling and domestic hot water systems. Soft EPDM seals provide tight shut off. The valve can handle the following types of media: Hot and chilled water. Water with antifreeze additives such as glycol. If the valve is used for media at temperatures below C (32 F), it should be equipped with a stem or yoke heater in order to prevent ice formation on the valve stem. SPECIFICTIONS Design......three-way plug valve stem up closed........................ ( port / - open) Pressure class....................... PN 16 Flow characteristic -............... EQM Flow characteristic -.......Complementary Stroke............................ 2 mm Rangeability Kv/Kv min.................... >5 Leakage - and -........ Tight sealing m.................. 4 kpa (58 psi), water Max. temperature of medium:............12 C Min. temperature of medium:............ 2 C Connection...... Flange according to ISO 75-2 Materials ody................nodular iron EN-JS 13 Stem................ Stainless steel SS 2346 Plug........................ rass CW62N Plug Seal........................... EPDM Seat.................Nodular iron EN-JS 13 Standard packing box........... Venta (EPDM) Pressure Equipment Directive PED 97/23/EC Cat. Size Kv Part number DN in. m 3 /h 15 ½ 1.6 731-1117- 15 ½ 2.5 731-1121- 15 ½ 4. 731-1125- 2 ¾ 6.3 731-1129- 25 1 1 731-1133- 32 1¼ 16 731-1137- 4 1½ 25 731-1141- 5 2 38 731-1145- Key to Technical specification The rangability is the ratio of Kv and Kv min. Kv (Cv) is the fl ow through the valve in m 3 /h at the specifi ed valve lift and at a pressure drop of 1 kpa across the valve. Kv min is the minimum controllable fl ow (m 3 /h) at a pressure drop of 1 kpa within the range in which the valve charac teristics conform to the slope requirements of IEC 534-1.

2 DESIGN ND CHRCTERISTICS The design of the gives good resistance against solid particles in the fluid. The plug is guided throughout the lift, which reduces the risk of vibrations. CHRCTERISTICS Flow 1 The is designed to be used as a mixing valve. 8 The valve closes port with the stem up. 6 The flow characteristics - of the is equal percentage modified. The flow characteristics - is complement to - for constant sum of flow at ß=,5. 4 2 Relative valve lift DESIGN 2 4 6 8 1 Installed characteristics β =,5 CVITTIONS Pressure drop chart at the beginning of cavitation (kpa) Static pressure before valve 16 16C (32F) CVITTIONS Cavitation takes place in a valve when the velocity of the flow between the plug and seat increases to the extent that gas bubbles are created in the water. When, after the plug and seat, the velocity decreases, the gas bubbles collapse (implode), generating conciderable noise and causing conciderable wear on the valve. 14 12 1 8 6 4 2 14C (284F) 12C (248F) 1C (212F) 8C (176F) 2C (68F) 1 2 3 4 5 6 kpa Pressure drop over valve Pressure drop limit where cavitation might occur is dependent of valve inlet pressure and temperature of water. y means of the cavitation diagram shown in the figure it can be checked if risk of cavitation exists with the working conditions in the pertinent installation. Proceed as follows: Using the static pressure before the valve (e.g. 1 kpa), plot the horizontal line to the line for the temperature of the liquide (e.g. 12 C). From the intersection point, plot a vertical line downwards and read off the max.permissible pressure drop across the valve. If the computed pressure drop exceeds the value read from the diagram there is risk for cavitation. Schneider Electric Telephone Europe: Malmö, Sweden +46 4 38 68 5 Telephone sia Pacific: Singapore +65 6776 3166 www.schneider-electric.com/buildings 3-2681-3 January 211 co 211 Schneider Electric. ll rights reserved.

3 SPECIFICTION OF CTUTOR Use the diagram below to select actuator motor for the to close required c. suitable actuator is selected, using the summary data sheet F-1-6. CTUTOR POWER M8 / MG9 SR Δ INSTLLTION The valve should be mounted with flow direction in accordance with the valve marking. It is recommended to install the valve in the return pipe, in order to avoid exposing the actuator to high temperatures. The valve must not be installed with the actuator mounted below the valve. To ensure that suspended solids will not become jammed between the valve plug and seat, a filter should be installed upstream of the valve, and the pipe system should be flushed before the valve is installed. Schneider Electric Telephone Europe: Malmö, Sweden +46 4 38 68 5 Telephone sia Pacific: Singapore +65 6776 3166 www.schneider-electric.com/buildings 3-2681-3 January 211 co 211 Schneider Electric. ll rights reserved.

4 INSTLLTION. Circuit without local circulating pump. To obtain good function the pressure drop across the valve should be no less than half of the available pressure drop (). This will give a valve authority of 5%.. Circuit with local circulating pump. The K V value of the valve to be selected so that the entire available pressure drop,, falls across the control valve. C. Circuit with local circulating pump. The K V value of the valve to be selected so that the pressure drop across the control valve becomes equal to or greater than. PRESSURE DROP CHRT Press. drop psi kpa 2 Capacity Kv (m /h at Δp=1 kpa),25,4,63 1, 1,6 2,5 4 6,3 1 16 25 4 2 15 15 1 8 6 5 4 3 2 2 8 7 6 5 1 8 7 6 5 4 3 2 1 8 7 6 5 4 3 2 1,1,2,3,4,6,8,1,2,3,4,5,8 1 2 3 4 5 6 7 8 9 1 2 3 4 5 6 8 1 l/s,2,3,4,5,8 1, 2 3 4 5 6 8 1 2 3 4 5 8 1 2 3 5 1 Schneider Electric Telephone Europe: Malmö, Sweden +46 4 38 68 5 Telephone sia Pacific: Singapore +65 6776 3166 www.schneider-electric.com/buildings 3-2681-3 January 211 co gpm Flow 211 Schneider Electric. ll rights reserved.

5 DIMENSIONS ND WEIGHT M8 E H D C F G Part No Conn. Dimensions Weight 731- C D E F G H DN In. mm mm mm mm mm mm mm mm kg 1117 15 ½ 13 65 123 4x14 2 38 95 65 2.5 1121 15 ½ 13 65 123 4x14 2 38 95 65 2.5 1125 15 ½ 13 65 123 4x14 2 38 95 65 2.5 1129 2 ¾ 15 75 126 4x14 2 41 15 75 3.2 1133 25 1 16 8 131 4x14 2 46 115 85 3.8 1137 32 1¼ 18 9 144.5 4x19 2 59.5 14 1 6.6 1141 4 1½ 2 1 146 4x19 2 61 15 11 7.5 1145 5 2 23 115 161 4x19 2 76 165 125 1. SPRE PRTS Stuffing box Standard type S........... max 15 C (32 F) Item number................... 1-1-8- On October 1st, 29, TC became the uildings usiness of its parent company Schneider Electric. This document reflects the visual identity of Schneider Electric, however there remains references to TC as a corporate brand in the body copy. s each document is updated, the body copy will be changed to reflect appropriate corporate brand changes. ll brand names, trademarks and registered trademarks are the property of their respective owners. Schneider Electric Telephone Europe: Malmö, Sweden +46 4 38 68 5 Telephone sia Pacific: Singapore +65 6776 3166 www.schneider-electric.com/buildings 211 Schneider Electric. ll rights reserved. 3-2681-3 January 211 co