TransPort PT878GC Panametrics Ultrasonic Portable Gas Flowmeter. GE Sensing. Applications. Features

Similar documents
TransPort PT878GC Panametrics Portable Gas Ultrasonic Flowmeter. GE Sensing. Applications. Features

TransPort PT878GC Panametrics Ultrasonic Portable Gas Flowmeter. GE Infrastructure Sensing. Features. Applications

DigitalFlow GF868 Panametrics Flare Gas Mass Ultrasonic Flowmeter. GE Sensing. Features. Applications

DigitalFlow GF868 Panametrics Flare Gas Mass Ultrasonic Flowmeter with Extended Performance Range

780S Ultra High Purity Series

Flow and Energy Measurement F-5400 THERMAL MASS FLOW METER

Pro-V Multivariable Flowmeter Model M22 In-line Vortex

Pro-V Multivariable Flowmeter

For Multi-Parameter Meters see mvx

For Multi-Parameter Meters see mvx

XMO2. Panametrics Smart Oxygen Analyzer. Applications. Features. bhge.com. An oxygen transmitter for use in:

Features. Description

Over 20,000 Strain Gage Target flowmeters installed since 1952.

PanaFlow MV82. Insertion Style Multivariable Flowmeter. GE Measurement & Control. Key Benefits. Applications

analytical bulk flow distance FLOW level pressure temperature industrial communication

GFM. Typical Aluminum GFM Mass Flow Meter NIST MASS FLOW METERS. Principles of Operation. Design Features

Ultra High Purity Model 780S

Design Features. General Description

TEK-THERMAL 1700B. Thermal Mass Flowmeter. FLOW. Technology Solutions

Integral type Differential pressure flowmeter VNT Series

Pro-V Multivariable Flowmeter Model M22 In-line Vortex

Two-Wire In Situ Oxygen Analyzer (550 to 1400 C)

Steel-Mass Model 640S

Online data sheet FLOWSIC30 GAS FLOW METERS

Torque Tube TB300 Digital Transmitters

MASS FLOW SYSTEMS MASS FLOW MEASURING, CONTROLLING AND BLENDING SYSTEMS

COMPAFLOW. Compressed Air. Volumetric flow. Gas. Mass flow. Steam. Net volumetric flow. Liquid

Vortex Flow Meter Wafer or Flange Connection. - Steam - Liquid - Gas

Turbine Flowmeters for Gas Applications

Technical Data Sheet. OPTIMASS 7000 Custody Transfer Mass Flowmeter

DPI 610/615 Series. Druck Portable. Pressure Calibrators. GE Sensing. Features. Setting the Standard for Portable. Pressure Calibrators

3000 Series OPTIMASS Mass Flowmeter. Stainless Steel Hastelloy

7000 Series OPTIMASS Mass Flowmeters. Titanium Hastelloy Stainless Steel

Vortex flow sensor VA Di Ex-d with integrated, configurable transducer UVA in a flameproof enclosure for applications in explosive atmospheres

VersaFlow Vortex 100 Vortex Flow Meter Technical Datasheet. Specification. The all-in-one solution. Highlights. Industries.

Autocalibration Systems For In Situ Oxygen Analyzers

T EK-COR 1100A. Coriolis Mass Flowmeter. FLOW. Technology Solutions

Turbine Flowmeters for Gas Applications

3.0 Pressure Transmitter Selection

Depth/Level. Druck Submersible Pressure Sensors Product Guide. GE Sensing. Applications. Features

Wafer type. the product

mass flowmeter approved by Weights and Measures for custody transfer

TEK-SUB 4800B. Submersible Level Transmitter. Flow Level Temperature Pressure Valves Analyzers Accessories TekValSys LEVEL

T EK-COR 1100A Coriolis Mass Flowmeter

L3 Pressure and Level transmitter

Flowatch Multiphase Flow Meter

LUGB Vortex Flowmeter

THERMAL MASS FLOW MEASUREMENT FOR GASES

AFC. SDPROC and AFC Analog Mass Flow Controller ANALOG MASS FLOW CONTROLLERS. Principles of Operation. Design Features

Level transmitter LT 100

Vortex Flow Sensor VA Di Ex-d for flow measurement in gases; with integrated, configurable transducer UVA in Ex-d housing

Ultrasonic Flowmeter USZ 08

C-Flow Coriolis Mass Flow Meters

OEM Manual MODEL 2305 ECONOMICAL DIGITAL SINGLE CYLINDER SCALE

Thermatel Model TA2 Mass Flow Transmitter

TH-1800-T TRX-700-CNG Converter

Level switches Series LD Vibrating fork level switch for liquids and solids

Steel-Mass Model 640S

Aurora. Moisture Measurement for Industrial Gases. GE Measurement & Control

3M Electrial Markets Division EMS. Electronic Marker System

L 100. Bubble-Tube Level System. Installation, Operation and Maintenance Instructions

Electronic gas volume corrector model DGVC-04

Turbine Flowmeters for Gas Applications (Metric)

A review of best practices for Selection, Installation, Operation and Maintenance of Gas meters for Flare Applications used for Managing facility

SDX Submersible Depth Transmitter User Manual

Differential Pressure Transmiter

P9000 DESCRIPTION. For parts requiring RoHS compliance, please contact factory. P February /6

SDX Submersible Depth Transmitter User Manual

Micro Motion 7835 Series Density and Concentration Meters

Non-intrusive Natural Gas Flow Measurement

DTG - LCD Digital Temperature Gauge USER MANUAL

Vortex flowmeters. Product family introduction Principle of operation Product review Applications Key product features

WELCOME TO THE REVOLUTION

Two-Wire In Situ Oxygen Analyzer (550 to 1400 C)

TRZ 03-K Volumeter. Proven Technology. Superior Performance. TRZ 03-K Volumeter is a Turbine Gas Flowmeter for Secondary Gas Metering.

Variable Area Flow Meters

TFE-LINED VAREA-METER PVC-TUBE VAREA-METER

Level switches Series LD Vibrating fork level switch for liquids and solids

Optical Dissolved Oxygen Meter

G4S G4A1KY RESIDENTIAL CONVERSION KIT LOW PRESSURE CONVERSION KIT MEDIUM PRESSURE CONVERSION KIT HIGH PRESSURE CONVERSION KIT ULTRASONIC GAS METER

WL16 WATER LEVEL LOGGERS Submersible pressure transducer and USB datalogger combination

BUBBLER CONTROL SYSTEM

FTS SUBMERSIBLE PRESSURE TRANSMITTER USER S MANUAL

Benefits. Rev.III_032018_Oxybaby 6.0_engl subject to technical alterations

SonoMeter 30 Energy Meters

EPR High Precision 3000 psi Electronic Pressure Controller Accurate to 0.25% of full scale

Features. Main Voltage: Vdc. Input Control Signal: 0-5 Vdc or 4-20 madc (Sourcing) Monitor Output Voltage: 0-5 Vdc or 4-20 madc (Sourcing)

OSAT Series. Intrinsically Safe Infrared Temperature Sensor Operator's Guide

The intelligent alternative for VA meters: mass flow meters for gases with flow display

SFC. SKYLINE FLOW CONTROLS INC. The Leader of Accurate and Reliable Flow Measurement DESCRIPTION & APPLICATIONS: ADVANTAGES:

Level transmitters and indicators Series LU Ultrasonic level transmitter and indicator for liquids and solids

Pneumatic high-pressure controller Model CPC7000

Additel 761 Automated Pressure Calibrators Selection Guide

P499 Heavy Duty Pressure Transducer

Additel 761 Automated Pressure Calibrators

Echotel Model 3P1 Pump Controller and Ultrasonic Level Transmitter

MODEL ANALOG ALTIMETER USER'S MANUAL 330KHZ, 1000M DEPTH RATED 0.2 TO 100FT OPERATING RANGE ANALOG OUTPUT

UNDERSTANDING, ACCELERATED

Visualize Nitrogen Gas Consumption

RCD - Ultra-Rugged Differential Pressure Flowmeter

Transcription:

Applications The TransPort PT878GC clamp-on gas flowmeter is a complete ultrasonic flow metering system for measurement of most gases, including: Natural gas Compressed air Fuel gases Erosive gases Corrosive gases Toxic gases High-purity gases Air separation gases Features Clamp-on unobstructed installation No wetted parts No moving parts No pressure drop Sound speed output Standard volumetric flow calculation Small, lightweight and easy to use Large, backlit LCD display Rechargeable battery pack Logs over 100,000 flow data points Submersible package 32 site locations Optional thickness gauge TransPort PT878GC Panametrics Ultrasonic Portable Gas Flowmeter TransPort PT878GC is a Panametrics product. Panametrics has joined other GE high-technology sensing businesses under a new name _ GE Industrial,. g

Portable Flow Metering at Its Best The TransPort PT878GC flowmeter is a highly versatile, self-contained, portable transit-time system with options and accessories to meet a variety of gas flow measurement needs. Its compact size, lightweight, rechargeable battery pack, and universal power supply charger make it the ideal go-anywhere flowmeter. Historically, clamp-on flow metering was limited to liquids because existing methods could not work on metal pipes containing gases. GE developed new technology that extends all the benefits of clamp-on flow metering to gas measurement. This remarkable ultrasonic technology works with gases at high or low pressure in pipes made of metal and most other materials. The TransPort PT878GC flowmeter can be used to measure the flow of any gas. It is especially useful for metering erosive, corrosive, toxic, high-purity or sterile gases, or in any application where penetrating the pipe wall is undesirable. Since no tapping or cutting of the pipe is required, permanent installation costs are significantly reduced. The meter has no wetted or moving parts, causes no pressure drop and has very wide rangeability. The new meter was tested extensively on metal pipes with diameters as small as 0.75 inches and as large as 24 inches. This meter is suitable for measuring the flow of air, hydrogen, natural gas and many other gases. No Pressure Drop, Low Maintenance Because the transducers clamp onto the outside of the pipe, they do not obstruct the flow inside the pipe. This prevents the pressure drops typically caused by other types of flowmeters. The TransPort PT878GC has no components that will foul or collect debris, and there are no moving parts to wear out. As a result, it requires no lubrication and little or no routine maintenance. Advanced Clamp-On Ultrasonic s One of the biggest challenges in developing clamp-on ultrasonic transducers for gas applications is the difficulty in transmitting a coded ultrasonic signal through a metal pipe wall, through the gas, and then back through the pipe wall to the second transducer that is waiting to receive the signal. In gas systems, only 4.9 x10 7 percent of the transmitted sound energy is actually received by traditional ultrasonic transducers. This simply isn t enough to produce reliable measurements. The new line of clamp-on gas transducers produces signals that are five to ten times more powerful than those of traditional ultrasonic transducers. The new transducers produce clean, coded signals with very minimal background noise. The result is that the TransPort PT878GC flowmeter system performs well even with low-density gas applications. GE s technologically advanced clamp-on gas ultrasonic transducers TransPort PT878GC portable flowmeter and accessories

Quick and Easy to Use It s possible to make the first flow measurement within minutes of opening the box the TransPort PT878GC flowmeter is that easy to use. Input the site parameters, clamp the transducers onto the pipe, and adjust the spacing. No ancillary equipment is needed, and there s no need to break into the pipeline. An experienced user can make scores of different measurements in a single day. The TransPort PT878GC flowmeter is ideal for all kinds of flow survey work. Built to Be Economical and Stay Economical To be of real value, a portable flowmeter must be as economical to own and operate as it is capable in the field. The TransPort PT878GC flowmeter is built to stay in service for many years. Completely solid state, the device rarely wears out or needs servicing, resulting in little downtime and low maintenance costs. Optional Pipe Wall Thickness-Gauge Pipe wall thickness is a critical parameter used by the TransPort PT878GC flowmeter for clamp-on flow measurements. The thickness-gauge option allows accurate wall thickness measurement from outside the pipe. Gas flow Ultrasonic signal path Transit-time flow measurement technique The TransPort PT878GC Flowmeter Uses the Transit-Time Flow Measurement Technique The transit-time technique uses a pair of transducers, with each transducer sending and receiving coded ultrasonic signals through the fluid. When the fluid is flowing, signal transit time in the downstream direction is shorter than in the upstream direction; the difference between these transit times is proportional to the flow of velocity. The TransPort PT878GC measures this time difference and uses programmed pipe parameters to determine flow rate and direction. Alphanumeric and Graphic Liquid Crystal Display Completes the Picture A large, multifunction LCD presents measured data in both alphanumeric and graphic forms. In addition, it helps make programming easy by presenting a software menu that walks you through data entry and function selection. Standard alphanumeric functions include flow velocity, volumetric or mass flow, and totalized flow in either English (U.S.) or metric units. Optional pipe wall thickness gauge In graphic mode, the LCD shows both real time and logged data. The result is a chart recording right on the display, which is very useful for reviewing data and observing trends while on site.

1 14 13 11 2 5 4 3 7 12 9 8 10 6 PT878GC Accessories Submersible, Rugged Electronics Housing 1 TransPort PT878GC 2 TransPort PT878GC AC charger 3 Clamp-on gas transducers 4 LEMO BNC transducer interconnection cable 5 Input/output cable 6 RS232 to infrared dongle 7 Thickness gauge 8 Printer 9 Printer AC charger 10 CFG-V1/V4/V8/V12 clamping fixtures This flowmeter is protected from the day-to-day rigors of industrial usage. The TransPort PT878GC is equipped with a rubber boot that provides protection against vibration and shock. The completely sealed housing and ports meet IP67 requirements, so the flowmeter will withstand submersion in up to 3 ft (1 m) of water for limited periods of time. It will continue to function safely even if it is dropped in water. Wide Range of Clamping Fixtures Available alignment is crucial in obtaining accurate measurements in clamp-on gas installations. GE offers a wide range of clamping fixtures to help ensure proper alignment of transducers with minimal effort. 11 CFG-PI fixture with chain and alignment blocks 12 Preamplifiers Clamping Fixture Downstream Preamplifier 13 Alignment wrap 14 Couplant PT878GC Preamplifier Upstream Typical meter setup for portable clamp-on gas flow

PT878GC Installation Requirements Table The following table shows the minimum pressure requirements of the TransPort PT878GC for given pipe sizes and wall thicknesses. Also provided is the maximum flow velocity of the meter for each case. Refer to the TransPort PT878GC installation and operation manuals for more detailed data. Nominal Pipe Size Pipe Wall Thickness Minimum Pressure Maximum Flow Velocity in (mm) in (mm) psig (bar) ft/s (m/s) Air NG Steam Air NG Steam 3/4 (20) ±0.07 (1.8) 60 (5.1) - - 90 (27.4) - - 1 (25) ±0.14 (3.6) 60 (5.1) - - 90 (27.4) - - 1-1/2 (40) ±0.15 (3.8) 60 (5.1) - - 90 (27.4) - - 2 (50) ±0.16 (4.1) 60 (5.1) 200 (14.8) - 90 (27.4) 110 (33.5) - 3 (75) ±0.22 (5.6) 60 (5.1) 200 (14.8) - 120 (36.6) 120 (36.6) - 4 (100) ±0.24 (6.1) 60 (5.1) 150 (11.4) 110 (8.6) 120 (36.6) 120 (36.6) 120 (36.6) 4 (100) ±0.34 (8.6) 180 (13.4) 400 (28.6) 200 (14.8) 120 (36.6) 120 (36.6) 120 (36.6) 4 (100) ±0.68 (17.3) 300 (21.7) 800 (56.2) - 72 (21.9) 72 (21.9) - 6 (150) ±0.28 (7.2) 60 (5.1) 150 (11.4) 110 (8.6) 90 (27.4) 120 (36.6) 120 (36.6) 6 (150) ±0.44 (11.2) 180 (13.4) 400 (28.6) 200 (14.8) 90 (27.4) 120 (36.6) 120 (36.6) 6 (150) ±0.87 (22.1) 300 (21.7) 800 (56.2) - 55 (16.8) 72 (21.9) - 8 (200) ±0.33 (8.4) 60 (5.1) 175 (13.1) 120 (9.3) 80 (24.4) 100 (30.5) 100 (30.5) 8 (200) ±0.5 (12.7) 180 (13.4) 400 (28.6) 200 (14.8) 80 (24.4) 100 (30.5) 100 (30.5) 8 (200) ±0.88 (22.4) 300 (21.7) 800 (56.2) - 80 (24.4) 100 (30.5) - 10 (250) ±0.37 (9.4) 60 (5.1) 200 (14.8) 130 (10.0) 70 (21.3) 85 (25.9) 85 (25.9) 10 (250) ±0.5 (12.7) 180 (13.4) 500 (35.5) 200 (14.8) 70 (21.3) 85 (25.9) 85 (25.9) 10 (250) ±1.0 (25.4) 300 (21.7) 800 (56.2) - 70 (21.3) 85 (25.9) - 12 (300) ±0.38 (9.7) 60 (5.1) 250 (18.3) 140 (10.7) 55 (16.8) 70 (21.3) 70 (21.3) 12 (300) ±0.5 (12.7) 180 (13.4) 500 (35.5) 200 (14.8) 55 (16.8) 70 (21.3) 70 (21.3) 12 (300) ±1.0 (25.4) 300 (21.7) 800 (56.2) - 55 (16.8) 70 (21.3) - 14 (350) ±0.38 (9.7) 90 (7.2) 300 (21.7) - 50 (15.2) 60 (18.3) - 14 (350) ±0.5 (12.7) 270 (19.6) 800 (56.2) - 50 (15.2) 60 (18.3) - 16 (400) ±0.38 (9.7) 90 (7.2) 300 (21.7) - 40 (12.2) 54 (16.5) - 16 (400) ±0.5 (12.7) 270 (19.6) 800 (56.2) - 40 (12.2) 54 (16.5) - 18 (450) ±0.38 (9.7) 90 (7.2) 300 (21.7) - 35 (10.7) 50 (15.2) - 18 (450) ±0.5 (12.7) 270 (19.6) 800 (56.2) - 35 (10.7) 50 (15.2) - 20 (500) ±0.38 (9.7) 90 (7.2) 300 (21.7) - 35 (10.7) 43 (13.1) - 20 (500) ±0.5 (12.7) 270 (19.6) 800 (56.2) - 35 (10.7) 43 (13.1) - 24 (600) ±0.38 (9.7) 90 (7.2) 300 (21.7) - 30 (9.1) 36 (11.0) - 24 (600) ±0.5 (12.7) 270 (19.6) 800 (56.2) - 30 (9.1) 36 (11.0) - How to use this table: 1. Find pipe size of your application. 2. Find pipe wall thickness of your application. 2A. Determine if your application meets the minimum pressure requirements given pipe size and pipe wall thickness as determined by pipe wall thickness. 2B. Determine maximum flow velocity capability. 3. Consult factory for natural gas with sulfur or high carbon dioxide content. 4. Consult factory for applications that are not listed above.

PT878GC Specifications Operation and Performance Fluid Types Acoustically conductive gases with minimum pressure requirements. See Installation Requirements table. Pipe Size Ranges 0.75 to 12 in (20 to 300 mm) with TransPort PT878GC-01 electronics 4 to 24 in (100 to 610 mm) and larger with TransPort PT878GC-02 electronics Pipe Wall Thickness Thicker walled pipes require greater gas density. See Installation Requirements Table. Pipe Materials All metals and plastics. No lined pipes. Flow Accuracy (Velocity) For pipes 6 in (150 mm) and smaller: ±2% to 5% of reading typical For pipes over 6 in (150 mm): ±1% to 2% of reading typical Accuracy depends on pipe size and other factors. Repeatability ±0.2% to 0.5% of reading Range (Bidirectional) See Installation Requirements Table. Rangeability (Overall) 150:1 Specif ications assume a fully developed flow prof ile (typically 20 diameters upstream and 10 diameters downstream of straight pipe run) and flow velocity greater than 5 ft/s (1.5 m/s). Pipes 2 inches (50 mm) or less require a minimum of 10 ft (3 m) of continuous straight run without flanges, welds or coupling joints. Measurement Parameters Standard and actual volumetric flow, flow velocity and mass flow Electronics Flow Measurement Patented Correlation Transit-Time mode Enclosure Submersible IP67 Dimensions Weight 3 lb (1.36 kg), size (h x w x d) 9.4 x 5.5 x 1.5 in. (238 x 138 x 38 mm) Display 240 x 200 pixel backlit LCD graphic display Keypad 25-key, rubberized tactile membrane keypad Internal Battery Rechargeable battery: 8 hours of continuous operation Battery Charger Input 100 to 250 VAC, 50/60 Hz, 0.38 A Memory FLASH memory, field-upgradable Operating Temperature 20 to 55 C ( 4 to 131 F) Storage Temperature 40 to 70 C ( 40 to 158 F) To ensure maximum battery life, storage temperature exceeding 35 C (95 F) is not recommended for more than one month. Standard Inputs/Outputs One 0/4 to 20 ma current output One user-selectable pulse (solid state, 5 V maximum) or frequency (5 V square wave, 100 to 10,000 Hz) Two 4 to 20 ma analog inputs with switchable power supply for loop-powered temperature or pressure transmitter Digital Interface Infrared communication port for printer or PC interface Site-Parameter Programming Menu-driven operator interface using keypad and soft function keys Online help functions including pipe tables Storage for saving site parameters

PT878GC Specifications Data Logging Memory capacity to log over 100,000 flow data points Keypad programmable for log units, update times, and start and stop time Display Functions Graphic display shows flow in numerical or graphic format Displays logged data Extensive diagnostic parameters European Compliance Battery-powered system complies with EMC Directive 89/336/EEC Clamp-On Ultrasonic Flow s Temperature Ranges Standard: -40 to 130 C (-40 to 266 F) Optional (overall range): -40 to 230 C (-40 to 446 F) Materials Stainless steel and plastic Mountings Portable gas-transducer clamping fixtures in polycarbonate carrying cases: PCFG-1 for pipes smaller than 12 in (300 mm) in diameter PCFG-2 for pipes larger than 12 in (300 mm) in diameter Cables Standard: One pair of LEMO coaxial transducer connectors with 25-ft (8-m) cables Optional: 500-ft (154-m) extension cables available for most transducers Thickness-Gauge Option GE dual-element transducer Pipe-Thickness Range 0.05 to 3 in (1.3 mm to 76.2 mm) Pipe Materials Most standard metal and plastic pipe materials Accuracy ±1% typical or ±0.002 in (±0.05 mm) Thermal Exposure Continuous operation to 37 C (100 F); intermittent operation to 260 C (500 F) for 10 seconds followed by two minutes air cooling Additional Options Printer Infrared, portable, thermal printer with rechargeable battery and 120 to 240 VAC power supply/recharger Weight 13 oz (370 g), size 6.3 x 6.5 x 2.3 in (160 x 164.2 x 59 mm), print width 4 in (104 mm) RS232-to-Infrared Infrared adapter plugs into any available serial port to give desktop PCs infrared capability Mounting Couplant CPL-16 Area Classifications Standard: General purpose Optional: Weatherproof Type 4 IP65 Optional: Explosion-proof Class I, Division 1, Groups C,D Optional: Flameproof e II 2 G EEx md IIC T6 T3 (certification pending) TransPort PT878GC electronics are designed for general purpose areas.

g 2004 GE. All rights reserved. 920-031C All specifications are subject to change for product improvement without notice. TransPort and Correlation Transit-Time are trademarks or registered trademarks of GE. GE is a registered trademark of General Electric Co. Other company or product names mentioned in this document may be trademarks or registered trademarks of their respective companies, which are not affiliated with GE. www.gesensing.com

Instructions: Please fill out the fields in color. Any field with a title block is a required field. Today's Date: Name: Phone: Company: Fax: Address: E-mail: Installation Address: Account Manager/Sales rep (if known) Process Data Tag Number(s): Stream composition and %: Flow Rate: Molecular Weight Viscosity: Density: Pressure: Temperature: Liquid Droplets: NO YES If yes, please specify % by volume: Suspended Solids: NO YES If yes, please specify % by volume: Pipe Orientation: Horizontal Flow Vertical Flow Up Vertical Flow Down Pipe Details Pipe Material: Pipe Size: Wall Thickness/Pipe Schedule: Pipe Lining: Flange Rating: Approx. Stright run of pipe: Upstream: Downstream: 20 Upstream,10 Downstream Recommended Indoors Outdoors Location: Hazardous Nonhazardous Submersible If Hazardous, specify area rating: Measurement Parameters Volumetric Units: Actual ft3 Actual m3 Std ft3 Std m3 Other (specify) 0 to 20 ma 4 to 20 ma 4 to 20 ma (loop) Other Type other output Output Units: Foundation Fieldbus HART Modbus/RS485 Modbus/TCP Ethernet OPC Server PanaView/RS232 PanaView/RS485 Analog Inputs: 4 to 20 ma Direct RTD Frequency/Pulse Output Forward Reverse None (all meters totalize on screen) Alarms: None High/Low/Fault Other Type other Alarm Wants Here Quantities of Each I/O: Electronics Requirements Area Clasification: Non Hazardous Hazardous If Hazardous (Fill out Further Info) If Hazardous, specify area rating: Electronic Housing Requirements: Weatherproof, corrosion-resistant NEMA 4X Explosionproof NEMA 7 Portable Other Enter Other Housing Requirement Here Cable Distance from electronics to transducers (500 ft maximum): Power Available: 100/120 VAC 220/240 VAC 12 to 24 VDC Desired Accuracy (% of reading): Desired Repeatability (% of reading): GE Gas Clamp-On Flowmeter Application Data Sheet Contact Information Special Requirements (data Logging, remote, totalization, etc.): Insert Nonproprietary Isometric or Sketch of Installation below or Attach PDF of Isometric as a separate file