Safety Manual > Safety Checklist for Labs

Similar documents
Laboratory Safety Review Checklist One Shields Ave Davis, CA Phone: (530) Fax: (530)

Laboratory Safety Review Checklist One Shields Ave Davis, CA Phone: (530) Fax: (530)

Laboratory Inspection Checklist

PURPOSE OF THE POLICY

Biosafety Level 2 (BSL2) Laboratory Safety Inspection Checklist

FLAMMABLE & COMBUSTIBLE LIQUIDS PROGRAM

Laboratory Safety Inspection Checklist

STANDARD OPERATING PROCEDURES (SOP) FOR REPRODUCTIVE HAZARDS

Safe Operating Procedure

Research Laboratory Safety Self-Inspection: Chemical & Physical Safety Checklists

LABORATORY SAFETY INSPECTION

Laboratory Self Inspection Checklist LAB01

SECTION 2 APPLICATION OF FUNDAMENTALS

CITY AND COUNTY OF DENVER CR&CF RISK UNIT Compressed Gas Safety Standard

Western Sydney University Safety Inspection Checklist - Laboratory Environments

LABORATORY SAFETY. A general overview

STANDARD OPERATING PROCEDURE (SOP): URETHANE

Compressed Gases and Cryogens

TEMPLE UNIVERSITY A Commonwealth University Environmental Health & Radiation Safety (EHRS)

Environmental: Hazardous Waste: Satellite Accumulation Areas (SAA)

(2) Review the CHP at least annually and revise the document as necessary to reflect current regulatory practice.

SECTION 7 HAZARD COMMUNICATION PROGRAM

UNH Department of Forensic Sciences

BIOSAFETY SELF AUDIT PRINCIPAL INVESTIGATOR/PERMIT HOLDER: CONTAINMENT LEVEL: 1 2 (Shaded) RISK GROUP: 1 2 AUDIT TO BE COMPLETED BY (DATE):

Instructions for Completing the UW-Madison Laboratory Chemical Hygiene Plan Template

Laboratory Safety Training. Environmental Health and Safety

Safety Data Sheet. Zero Air 1 PRODUCT AND COMPANY IDENTIFICATION. Manufacturer NorLab a division of Norco 898 W. Gowen Rd.

Doc No: WELDHOT Midland Engineering Co., Inc. Initial Issue Date 12/14/15 Safety Management System

Hazard Communication Program

MINIMUM SAFETY REGULATIONS

DEPARTMENT SCHOOLS OF HEALTH. respiratory protection. Proper adherence to bloodborne pathogen handling protocols.

MATERIAL SAFETY DATA SHEET (MSDS) MATERIAL SAFETY DATA SHEET EM SCIENCE 1. CHEMICAL PRODUCT AND COMPANY IDENTIFICATION. Catalog Number(s):

Self Inspection Checklist

Laboratory Safety Manual Prepared by RAEIN-Africa & Partners. Under the Implementation of The National Biosafety Framework Project for Swaziland

Hot Work Program. University of Wisconsin-Platteville Reviewed 4/2016

Risk Management Resources

Operations: HSE. Health and Industrial Hygiene. Laboratory Safe Work Practice

SAFETY DATA SHEET (SDS)

Cylinder Exchange Training Manual

Laboratory Safety Inspection Form. Building: Department: Room(s): Contact Person: Inspection Performed by: Organization:

Purpose Written Program Hazard Classifications (GHS) SDS Sheets (GHS) Labels (GHS) Employee Training Chemical Safety Questions

CHECKLIST FOR LABORATORY BASED INSPECTIONS

DEPARTMENT SCHOOLS OF HEALTH

TYPICAL TOXIC GAS SYSTEM INSPECTION VIOLATIONS

Developing Safety Guidelines for Cryogenic Liquids.

SHOP SAFETY INSPECTIONS

Concordia College Moorhead, Minn.

SAFETY DATA SHEET (SDS)

CONTRACTOR SAFETY RULES

HAZCOMM & Lab Safety College of Dental Medicine Research Safety Specialist Environmental Health and Safety

To fill out this checklist online from a tablet or phone, please use the SIT tool on UC Safety Suite. Principal Investigator/Laboratory Supervisor:

SAFETY DATA SHEET (SDS)

Chemical Hygiene Plan

MATERIAL SAFETY DATA SHEET EM SCIENCE

The primary purpose of laboratory fume hoods is to keep toxic or irritating vapors out of the general laboratory working area.

SAFETY DATA SHEET (SDS)

SAFETY POLICY AND PROCEDURE MANUAL All Euramax Subsidiaries. Number K-3.0 Welding Safety Procedures

24 Hour Emergency CHEMTREC

Compressed Gases STANDARD OPERATING PROCEDURE

Safety and Health Policy and Procedure Manual. WELDING, CUTTING, and BRAZING PROGRAM Section 0140

MATERIAL SAFETY DATA SHEET EM SCIENCE 1. CHEMICAL PRODUCT AND COMPANY IDENTIFICATION

TFS Safety Manual. Laboratory and Research Safety

STORAGE OF COMPRESSED GAS CYLINDERS (SAF-SPI-15)

Ruptured Gas Cylinder Destroys Laboratory Hood at the University of Nevada

SAFETY DATA SHEET. Section 1: Company and Product Identification. Section 2: Hazard(s) Identification. Section 3: Product Composition

UNIVERSITY OF ROCHESTER ENVIRONMENTAL HEALTH & SAFETY

Compressed Gas Cylinders - Guideline

Post MD in Residence Placement

SAFETY DATA SHEET (SDS)

INSTALLATION MANUAL Matheson Tri-Gas Cabinet Enclosures

Management Plan for Confined Spaces

FLAMMABLE GASES AND FLAMMABLE CRYOGENIC FLUIDS

Cryogenic Materials Operating Procedure and Safety Requirements

Activated Carbon %

Refrigerant R170 - ETHANE

ESCONDIDO FIRE DEPT TRAINING MANUAL Section Truck Module Page 1 of 5 Utilities Gas Emergencies Revised

SDS SAFETY DATA SHEET

MATERIAL SAFETY DATA SHEET C-MUL SUN DRILLING PRODUCTS CORP.

: Accu-Sed Plus Normal & Abnormal ESR Control Kit

MINNESOTA STATE UNIVERSITY MOOHREAD CHEMICAL HYGIENE PLAN

Risk Management Resources

Vision Painting Inc Safety Management System

: Rinse skin with water/shower.

MATERIAL SAFETY DATA SHEET (MSDS) MATERIAL SAFETY DATA SHEET EM SCIENCE 1. CHEMICAL PRODUCT AND COMPANY IDENTIFICATION. Catalog Number(s):

Laboratory Preparedness Checklists for Advanced Planning, Preparing to Close & Safe Re-Entry

HEAT EXCHANGE AND TRANSFER, INC. 500 Superior Street Carnegie, PA (412) Fax: (412)

LABORATORY FUME HOOD SPECIFICATION AND MAINTENANCE PROGRAM

HAZARD COMMUNICATION SELF INSPECTION CHECKLIST

SAFETY DATA SHEET. Section 1: Company and Product Identification. Section 2: Hazard(s) Identification Anza Drive

Rapid Access Film Developer Concentrate

1. Safety glasses are to be worn at all times in the laboratory except in the study area adjacent to the lab.

Laboratory Safety Coordinator Meeting

UTMB RESPIRATORY CARE SERVICES GUIDELINES Respiratory Care Services Medical Gas Cylinder Storage, Use and Transport

GUIDELINES FOR CONDUCTING HYDROGENATION REACTIONS

Section 1.3: PRESSURE VESSEL COMPONENTS AND SYSTEMS AND COMPRESSED GAS CYLINDERS

Welding and Cutting (Hot Work) Operations Self-Audit Checklist. Building Room Supervisor Date

Hydrogen in Air % to 2%

Environmental Health and Public Safety. Graduate Student Safety Training

Electrical Safety. Introduction

Transcription:

Safety Manual > Safety Checklist for Labs Safety Checklist For Labs Where Infectious Agents And Recombinant DNA Research Is Performed This Checklist is to be used for research labs using infectious agents and/or recombinant DNA. For fire hazards, this checklist assumes that the lab is classified as a Class C lab for NFPA compliance. Class A and Class B (NFPA classification) lab units are higher hazard labs that must have special considerations in construction and operation. Item Yes No* Description Biological Safety 1 Have all people involved in the experiments or research been trained in the procedures to be used? Are training records available and adequate? 2 Are only authorized personnel permitted in the labs where infectious agents and/or recombinant DNA work is conducted? Are tours conducted only by the Director or PI or their designee? 3 Are emergency procedures in writing and understood by all? 4 Are infectious agents and recombinant DNA experiments confined to the designated laboratory areas? 5 Is there an approved Request for Approval of the Use of Recombinant DNA and Addendum to Recombinant DNA Use Form (as needed) on file for each protocol? 6 Are research related accidents, significant problems or violations of the NIH guidelines reported to the IBRDS Committee and the Office of Recombinant DNA Activities as required by NIH guidelines? 7 Is a copy of the NIH/CDC guidelines readily available for reference along with a copy of the University Manual for Investigators Using Infectious Agents and Recombinant DNA in Research? 8 Is the lab ventilation properly set up in accordance with the requirements using negative air pressure and laminar flow to assure containment of agents or other experiment emissions? Comments

Fire and Explosion Safety (A Laboratory Unit consists of the rooms used for lab work and administration, but rooms must be contiguous. It can range in size from a single room to an entire floor or building.) 1 Where storage cabinets and/or safety cans are not used, is the amount of Class I, II and III flammables in the lab unit less than the maximums per 100 sq. ft. shown below? Research Labs Teaching Labs Class I (Flash Point «73, Boiling Pt.«100F) 2 1 gallon Class I, II, and III (Flash Pts. «73-200F) 4 2 2 Where storage cabinets and/or safety cans are used, is the amount of Class I, II, and III flammables in the lab unit less than the maximums per 100 sq. ft. shown below? Research Labs Teaching Labs Class I (Flash Point «73, Boiling Pt.«100F) 4 2 Class I, II, and III (Flash Pts. «73-200F) 8 4 3 Is the total quantity of flammables in the laboratory unit less than the values below? Note: Use one half of these values for a teaching lab. Sprinklered No Sprinklers Class I totals No safety cans/cabinets 150 75 With safety cans/cabinets 300 150 Class I, II, III tot. No safety cans/cabinets 300 150 With safety cans/cabinets 400 200 4 During daily use is the storage of class I & II liquids limited to 10 when located outside of a storage cabinet? 60 for class III liquids? 25 for class I & II liquids when stored in safety cans outside of storage cabinets? 5 Are flammable liquids containerized properly according to the table below? Container Type Flammable Class IA IB IC II III

Glass 1pt 1qt 1gal 1gal 1gal Metal 1gal 5gal 5gal 5gal 5gal Safety Can 2gal 5gal 5gal 5gal 5gal Polyethylene 1gal 5gal 5gal 60gal 60gal 6 Are flammable liquid storage cabinets being used properly? Flammable Class Max. Storage Capacity class I, II total 60 Class I, II, III total 120 7 Are containers of materials that may become hazardous upon prolonged storage (ether, tetrahydrofuran, etc.) dated when first opened? Is the material evaluated every six months for continued safe use? 8 Is sprinkler head clearance of 18 in the clear maintained in all lab unit areas? 9 Are penetrations in the fire rated ceilings, floors and walls of your lab unit sealed to prevent smoke, fire and vapors from escaping to other areas? 10 Are floor openings sealed or curbed to prevent spillage into other rooms below? 11 Is a second means of exit provided when one or more of the following conditions exists? Explosion hazard blocks escape or access to work area. Lab work area exceeds 1000 sq. ft. A hood is located adjacent to the primary means of exit access. A compressed gas cylinder (larger than lecture bottle size) is in use that contains a gas that is flammable or has a health hazard rating of 3 or 4, and could prevent safe egress in case of accidental release of contents. A cryogenic container is in use that contains a gas that is flammable or has a health rating of 3 or 4, and could prevent safe egress in case of accidental release of contents.

12 Is furniture arranged so that a means of access to an exit can be reached easily from any point? Are hallways and exits clear of obstructions? 13 Is an evacuation and emergency action plan available for employees in the unit? Are Exit signs visible and functioning? 14 If fire doors are not self-closing, are they closed? 15 Is a portable fire extinguisher located within 25 feet of your lab unit? 16 Is access to lab units where explosion hazards exist restricted to only those necessary for the work? 17 Are compressed gas cylinders with a health hazard rating of 3 or 4 (and a rating of 2 where no physiological warning properties exist) kept inside a continuously mechanically ventilated hood or other enclosure with no more than 3 cylinders per hood or enclosure? 18 Are there no more than 6 compressed gas cylinders (10 50 in.) per 500 sq. ft. (3 in a non sprinklered space) of flammable gases/oxygen, no more than 3 liquified flammable gas cylinders (9 30 in.) per 500 sq. ft.(2 cylinders in non sprinklered space), and no more than 3 cylinders (4x15in.) of health hazard rating of 3 or 4? 19 Are compressed gas cylinders capped when not in use and secured at all times? 20 Are cylinders that are not necessary for current use stored outside the work area in a safe location? General Safety Considerations 1 Is a laboratory safety coordinator appointed for each department? 2 Are all chemical shipments dated when received and when opened? 3 Is there an inventory of chemicals with the suspect or known carcinogens identified? 4 Are chemical Safety Data Sheets (SDS) available in the laboratory? 5 Are chemicals stored by hazard classification and compatibility? 6 Is all laboratory equipment periodically inspected for defects?

7 Is protective equipment, such as gloves, face shields, etc., provided and used by lab personnel as called for on the SDS? 8 Are electrical outlets grounded? Where work with portable tools and/or cords is in a wet area, are ground fault interrupters used (unless the tools are double insulated)? 9 Are extension cords used only in temporary situations where the use will not exceed 90 days or the life of the experiment? Are they adequately sized for the electrical current and protected against damage? (The minimum size for an extension cord is #16AWG.) 10 Are all original and subsequent containers of chemicals and other agents labeled/identified, with precautionary information provided? Are the storage cabinets and other storage areas also labeled in the same manner? 11 Are entrances to laboratory units, laboratory work areas, storage areas, and associated facilities identified by signs to warn emergency response personnel of unusual or severe hazards not directly related to the fire hazard of contents? 12 Are written standard operating procedures that incorporate safety requirements such as personal protective equipment, etc., used? 13 Is regular surveillance for abnormal conditions made on unattended or automatic laboratory operations involving hazardous chemicals? 14 Are emergency eye wash/showers available to those exposed to chemical accidents? 15 Are emergency telephone numbers prominently posted on telephones? 16 Are lab unit workers trained in safety requirements such as fire extinguishers, first aid, etc.? * No answers must be accompanied by comments that explain corrective action needed Report completed by: Title: Laboratory Room #: Building:

Date of Report: