PVC Quick Drain Valve

Similar documents
Clean Regulator/Fluororesin Type

Pilot Check Valve: Metal Body Type

Regulator for 2 MPa ARX 20. How to Order. Bracket. Pressure gauge. Port size 1/8 1/4. Panel nut

Process Pump. PAF3000 Series/PAF5000 Series

Related Products: Auto Drain Valve. Model/Specifications. Model

Series AMJ. Drain Separator for Vacuum

F.R.L. Units Precautions 1 Be sure to read this before handling.

Series IRV1000/2000/3000

Series SFD. Clean Air Filter. Variations. Made to Order. Type. Cartridge (replaceable element) Disposable (non-replaceable element) Up to 100

SeriesTRBU. Flame Resistant (Equivalent to UL-94 Standard V-0) FR Double Layer Polyurethane Tubing

Air operated valve. VGA342R Series

Cautions : 1. Clogging of the element raises resistance to exhaust, thus lowering the

COMMON PRECAUTIONS Data Sheet - Be Sure To Read Before Handling Page 1 of 6

F.R.L. Units Precautions 1 Be sure to read this before handling products.

Series AS-FPQ/AS-FPG. Speed Controller with One-touch Fitting for Clean Room. Speed controllers for clean room use

Smooth Vent Valve. Series XVD XL XL Q D- XVD XGT CYV

Doc. No.SYJ300-OMO0002-A. Air Operated Valve PRODUCT NAME. SYJA300 / SYJ3000 Series MODEL/ Series

Process Pump Automatically Operated Type (Internal Switching Type) Air Operated Type (External Switching Type) How to Order. Option. Symbol.

Operation Manual Air Saver Unit ASV5000 Series

Process Pump. Series PAF3000/Series PAF5000

Smooth Vent Valve XVD. Series

Smooth Vent Valve. XVD Series

Low Friction Cylinders

No.IL02-OM00011-A PRODUCT NAME LOCK UP VALVE. MODEL/ Series IL201 IL211

5 Port Air Operated Valve

Power Valve: Precision Regulator. High precision, large capacity relief regulator

(1) Type (2) Thread size (T) (3) Wrench size specification : inch spec. (NPT, UNF) : mm spec. (M, R)

Pressure Relief 3 Port Valve New. Sonic Conductance 45% With the indicator window Step1. With locking holes

Cautions : 1. The gauge orientation on the GPU and GPM types can be changed by using

5.0 MPa Maximum Supply Pressure. New. Stepless control of air pressure proportional to an electrical signal. Series ITVX CAT.

Specifications. Construction. 2 port valve/series VHK2 3 port valve/series VHK3. Component Parts. Standard style. Flame resistant style

Hand Valve Series. Push-In Fitting Type Shut-off Valve (Residual Pressure Release Valve) Control Open/Close for Air Supply.

30% (SMC comparison) Silencer. New. New. The M5 silencer is now added! The resin silencer is now a more compact size! Series AN.

Cautions : 1. Be careful when you release the Stop Fitting with some internal pressure

Low torque Metal seal type Rotary joint

1/2 to 2-1/2 NPT; 0 to 230 PSI Advantages / Benefits

New Product. Air Consumption 70% Down. Precision Regulator Air Saving Type. RPE Series PRECISION REGULATOR RPE SERIES CC-1072A

Direct Operated Precision Regulator Modular Style. Standard Specifications

IR1000-A IR1010-A IR1020-A

Change Valve. Push-In Fitting Type Three-way Changeover Valve. Changeover Air Direction by 90. Lightweight and Compact Design.

Model GP PRESSURE REDUCING VALVE Installation & Operation Manual

(1) Name of tube (2) Tube dia. (O.D./I.D.) (3) Tube length. (4) Tube color. Model UD0425. UD1290 O.D. I.D. (mm) UD1075 UD0860 UD

Process Pump. Flare type (LQ3 fitting) added to the type with nut. Series PAF CAT.ES100-59C. Series PAF5000. Series PAF3000. New

reduces flow setting time and setting errors!

Coiling Tube with Twist-Proof Fitting

PRODUCT NAME. Main Line Filter. MODEL / Series / Product Number

Process Pump. Self-priming makes priming unnecessary. Air operated type. Air supply port. 5 port solenoid valves. Application Example

Booster Regulator/Air Tank

Model GPR Primary Pressure Regulating Valve. Instruction Manual

Maximum 0.85 MPa pressure setting Long-life, high flow perfect for balancer applications

Push-In Fitting Type Pressure Gauge

Angle Seat Valve / Air Operated Type

How to Order. Body size. Pressure: 2 MPa. Pressure increase ratio 0 Twice. Symbol. Thread type. Body size

Push-In Fitting Type with Stop Valve

Push-In Fitting Type Silencer

Filter-Regulator-Lubricator

(1) Type (2) Cylinder dia. (3) Gripper action : Single-acting closing gripper (normally open) (4) Holder type

Process Pump PB1000A

(2) Effective sectional area (no code for mini type) (3) Intake-side shape (no code for mini type) : Quick-fitting joint type : Taper pipe thread type

435 psi (3.0 MPa) Maximum Supply Pressure High Pressure Electro-Pneumatic Regulator. Maximum supply pressure. Set pressure range.

Type 2000 INOX. Quickstart. English Deutsch Français. 2/2-way angle seat valve 2/2-Wege Schrägsitzventil Vanne à siège incliné 2/2 voies

Filter-Regulator-Lubricator

THE HF-300 SERIES. Operating and Service Manual. Series includes all variants of HF-300/301

Insert Ring. Protection Ring from Tube Deformation. Protect tubes from deformation. Ultra soft tube is connectable to Fitting.

VACUUM REGULATORS CONTENTS

Needle valve. Contents. User s Manual. (1) Be sure to read the following warranty clauses of our product 1. (2) General operating instructions 2

Compact Regulator. ARX20 Series. 2.0 MPa compatible, piston type compact regulator ARJ

kpa or less 5.0. Compressed Air Preparation Filter. AFF/AM/AMD Series CAT.ES30-17B. 1 μm (Current model: 3 μm) 20% 60% 52% 160 mm.

(1) Union Filter for positive and negative pressure (2) Filter size. (3) Tube dia. (4) Holder option : without Holder : with Holder

User guide DIAPHRAGM SEALS. Industrial instrumentation for Pressure and Temperature

Instrument Operating Manual

(1) Type. (2) Tube dia. (ød) : ø8mm (ø5/16in.) (3) Thread size (T) (4) Specification. Fluid medium. Air, water * 1, * 2, * 3 Max. operating pressure

Apollo Standard Port, Full Port & One Piece Flanged Ball Valves Installation, Operation, & Maintenance Manual

Industrial Filter. FGD series

Installation Operating Instructions for Simple Duplex Manual Manifolds PX-TSD Series

Process Pump Automatically Operated Type (Internal Switching Type) Air Operated Type (External Switching Type) How to Order

Membrane Air Dryer. IDG1-C06 Series IDG1-C06-P Series

Vacuum Saving Valve Series ZP2V How to Order ZP2V A5 03 Connection thread symbol for the pad Male thread connection Symbol Thread Applicable fixed ori

Ball valve. Operating instructions for series. Version BA Print-No TR MA DE Rev001

Pressure Gauge Series

5 Port Solenoid Valve

Port size. Model Screw-in ZFA10 1/8 ZFA20 1/4 ZFB10 ZFB20 ZFB30 ZFB40 ZFC5 ZFC7

THE MF-400 SERIES. Operating and Service Manual. Series includes all variants of MF-400/401

Manual Actuated Boiler Blowdown Valves

THE BP-690 SERIES. Operating and Service Manual. Series includes all variants of BP-LF/MF-690/691

DC5A. Cyclone Separator Trap for Air. Copyright 2015 by TLV Co., Ltd. All rights reserved ISO 9001/ ISO MA-03 (DC5A) 19 June 2015

Modular valve block. Operating manual Series MVB 100/200. Version BA EN Print-No TR MA DE Rev001

Regulator. Accessory. Description. Symbol. Nil. With bracket. B With round. Port size. (Without limit indicator) With set nut (For panel mount)

SA121, SA122, SA123, SA128 and SA1219 Self-acting Temperature Control Systems (Dial Adjustment)

THE BP-301 SERIES. Operating and Service Manual. Series includes all variants of BP-301 (LF 0.1Cv / MF 0.5Cv)

(1) Type (2) Tube dia. (ød(1)) (3) Thread size (T) (4) Wrench size specification : inch spec. (NPT, UNF) : mm spec. (M, R)

GI Series Diaphragm Pressure Gauge Guard

Doc. No.VFR3000-OMH0005-B. 5 Port Air Operated Valve PRODUCT NAME. VFRA3000, 4000 Series MODEL/ Series

Recommended applicable tubing. Specifications. Operating vacuum pressure. 20 C to 80 C Threads. Principal parts material

Self-priming makes priming unnecessary Exhausts the air inside the suction pipe to suck up liquid. Air operated type.

Self Control Valves. User s Manual. Pressure Reducing Type (V182,V82) Pressure Relief Type (V185) Pressure Retaining Type (V186)

Clean Gas Filter. SF Series. Cartridge Type/Disposable Type IDFA IDFB IDH ID IDG IDK AMG AFF AM AMD AMH AME AMF ZFC SF SFD LLB AD GD SFC10

Wafer Check Valve. Contents. User s Manual. (1) Be sure to read the following description of our product warranty 1

Mounting and Operating Instructions EB 3007 EN. Self-operated Pressure Regulators. Differential Pressure Regulators (opening) Type Type 42-25

Specifications. Construction. 2 port valve/series VHK2 3 port valve/series VHK3. Component Parts. Standard style. Standard style

Transcription:

PVC Quick Drain Valve LVW Series Complies to JIS standard for polyvinyl chloride piping (JIS K 6742) Applicable fluids: Deionized water, Chemical liquids Application Example Cleaning Equipment Process pump Digital flow switch LVC LVA LVH LVD LVQ LVP LVW LQ1 LQ3 LVN LQHB TL TIL TLM TILM TD TID TH TIH Air operated valve Quick Drain Valve Fluid contact materials Body PVC Poppet PTFE (Standard) (Optional) Orifice size ø25, ø40, ø65, ø80 low-rate characteristics Cv factor: 10 to 198 Easy piping with union connection Applicable PVC piping external diameter ø32 to ø89 851

PVC Quick Drain Valve LVW Series How to Order LVW 60 25A Symbol PA B A PB Symbol 60 80 90 Body class 6 8 9 Series Orifice size ø25 ø40 ø65 ø80 Port size Symbol Applicable PVC piping external diameter Body class 25A ø32 6 32A ø38 40A ø48 8 50A ø60 65A ø75 9 80A ø89 material Symbol Material Nil N Pilot port thread type Symbol Thread type Nil Rc1/8 N NPT1/8 Standard Specifications Model Nominal diameter Applicable pipe size external diameter Operating pressure Orifice size Pilot pressure Kv Flow rate characteristics Cv Fluid temperature Valve leakage LVW60 25A ø32 ø25 8.5 10 LVW80 32A ø38 40A ø48 50A ø60 0 to 0.02 MPa ø40 ø65 0.3 to 0.5 MPa 18.8 22 43.7 51 71.1 83 0 to 60 C 0 cm 3 /min (with water pressure) LVW90 65A ø75 131.1 153 80A ø89 ø80 169.7 198 852

PVC Quick Drain Valve LVW Series Construction IN r t y LVC LVA e LVH u i o!0 Component Parts No. Description Material Optional 1 Body PVC LVD LVQ LVP q w 2 3 4 5 Housing Poppet Union end Union nut PVC PTFE PVC PVC LVW LQ1 6 7 LQ3 8 9 LVN OUT 10 LQHB TL TIL Dimensions TLM TILM TD TID TH TIH ød3 ød2 ød1 IN L1 2 x Rc1/8 (NPT1/8) Pilot port L2 PA PB L4 OUT L1 L3 Dimensions Part no. L1 L2 L3 L4 D1 D2 (mm) D3 LVW60-25A LVW80-32A LVW80-40A LVW90-50A LVW90-65A LVW90-80A 22 26 31 39 44 51 81.5 94 101 136.5 138.5 143.5 14.5 20.5 20.5 26 26 33 172 205 220 275 279 304 32 38 48 60 75 89 60 72 83 100 135 158 70 90 90 120 120 140 853

LVW Series Applicable Fluids PVC Quick Drain Valve Material and Fluid Compatibility Check List Ammonium hydroxide Isobutyl alcohol Isopropyl alcohol Hydrochloric acid Hydrogen peroxide Chemical Temperature 40 C or less Temperature 40 C or less Temperature 40 C or less Concentration 30% or less Concentration 5% or less, Temperature 50 C or less Compatibility Material option N Note 2) Note 1), 2) Note 1), 2) Note 2) Nitric acid (except fuming nitric acid) Deionized water Sodium hydroxide (Caustic soda) Nitrogen gas Ultrapure water Concentration 10% or less, Temperature 40 C or less Concentration 50% or less Note 2) Sulfuric acid (except fuming sulfuric acid) Concentration 30% or less Note 2) Phosphoric acid Concentration 50% or less The material and fluid compatibility check list provides reference values as a guide only. Note 1) Since static electricity may be generated, implement suitable countermeasures. Note 2) Fluid may pass through. Fluid that has passed through may have an impact on components made of different materials. Compatibility is indicated for fluid temperatures of 60 C or less. The material and fluid compatibility check list provides reference values as a guide only, therefore we do not guarantee the application to our product. The data above is based on the information presented by the material manufacturers. SMC is not responsible for its accuracy and any damage happened because of this data. Table symbol : Can be used : Can be used under certain conditions 854

LVW Series Specific Product Precautions 1 Be sure to read this before handling the products. Refer to back page 50 for Safety Instructions. Design/Selection 1. Check the specifications. Give careful consideration to operating conditions such as the application, fluid and environment, and use within the operating ranges specified in this catalog. 2. Fluids Operate after confirming the compatibility of the product's component materials with fluids, using the check list on page 854. Please contact SMC regarding fluids other than those in the check list. Operate within the indicated fluid temperature range. 3. Maintenance space Ensure the necessary space for maintenance and inspections. 4. Fluid pressure range Keep the supplied fluid pressure within the operating pressure range specified in this catalog. 5. Ambient environment Install the product in an environment where there is no effect from radiant heat caused by heat sources, etc., and use within the ambient operating temperature range. After confirming the compatibility of the product's component materials with the ambient environment, operate so that fluid does not adhere to the product's exterior surfaces. 6. Liquid seals When circulating fluid Provide a relief valve in the system so that fluid does not get into the liquid seal circuit. 7. Countermeasures for static electricity Since static electricity may be generated depending on the fluid being used, implement suitable countermeasures. Mounting 1. If air leakage increases or equipment does not operate properly, stop operation. After mounting, perform suitable function and leak tests to confirm that the mounting is correct. 2. Operation manual Mount and operate the product after reading the manual carefully and understanding its contents. Also, keep the manual where it can be referred to as necessary. Piping 1. Preparation before piping Before piping is connected, it should be thoroughly blown out with air (flushing) or washed to remove chips, cutting oil and other debris from inside the pipe. Install piping so that it does not apply pulling, pressing, bending or other forces on the valve body. 2. Use the tightening torques shown below for the pilot port. Tightening Torque of Pilot Port Pilot port Torque (N m) Rc, NPT1/8 0.8 to 1.0 3. Use of metal fittings In the case of threaded pilot port, do not pipe the metal fittings which can cause damage to the thread part. 4. Tighten the union nuts on both sides equally by hand. A watertight seal can be obtained by hand tightening. Never use a pipe wrench etc., as it may break the product. Table 1 shows the tightening torque for reference. Table 1 Tightening Torque of Union Nut Nominal dia. mm (inch) Tightening torque N m 25 (1) 4.0 32 (1 1 /4) 6.0 40 (1 1 /2) 8.0 5. When applying adhesive to the union end or union bushing, the seals can be damaged by the adhesive running into the seals. Always remove the union end and union nut from the body when applying adhesive. 6. In places where vibration could be applied to the union, take countermeasures to prevent vibration. 7. Do not tighten the union while there is pressure left in the piping. Pilot Air Supply 50 (2) 12.0 For fittings of 65A or larger, tighten the fittings by a further 1/8 rotation (45 ) with a belt wrench after tightening by hand. However, do not use metal tools. 1. Use clean air. Do not use compressed air which includes chemicals, synthetic oils containing organic solvents, salt, or corrosive gases, etc., as this may cause damage or malfunction. LVC LVA LVH LVD LVQ LVP LVW LQ1 LQ3 LVN LQHB TL TIL TLM TILM TD TID TH TIH 855

LVW Series Specific Product Precautions 2 Be sure to read this before handling the products. Refer to back page 50 for Safety Instructions. Operating Environment 1. Do not use in locations having an explosive atmosphere. 2. Do not operate in locations where vibration or impact occurs. 3. In locations near heat sources, block off radiation heat. 4. Do not use in environments which exceed the ambient temperature specifications of the product. Operating Precautions 1. Operate within the ranges of the maximum operating pressure. 1. Fluorine grease is used on the sliding part of the piston, so the grease is in contact with the fluid. PVC Piping 1. PVC fitting (union) The PVC fitting (union) must be mounted and joined by an engineer with sufficient knowledge. Be sure to confirm that there is no leakage from the fitting after mounting and joining. If it is mounted and joined by a person who does not have sufficient knowledge and skills, it may lead to failure such as leakage. 2. When selecting adhesive for the PVC fitting (union), confirm that its heat resistance and endurance are compatible with the operating temperature of the fluids used. Otherwise, this may cause leakage and damage. 3. Do not apply excessive force to the PVC piping. This may cause damage. 4. When the PVC piping type is used, the higher the fluid temperature, the lower the proof pressure will be. Therefore, adjust the water hammer pressure carefully so that it does not exceed the proof pressure. Return of Product If the product to be returned is contaminated or is possibly contaminated with substances that are harmful to humans, for safety reasons, please contact SMC beforehand and then employ a specialist cleaning company to decontaminate the product. After the decontamination prescribed above has been carried out, submit a Product Return Request Sheet or the Detoxification/Decontamination Certificate to SMC and await SMC s approval and further instructions before attempting to return the item. Please refer to the International Chemical Safety Cards (ICSC) for a list of harmful substances. If you have any further questions, please don t hesitate to contact your SMC sales representative. A Maintenance 1. Maintenance should be performed in accordance with the procedures in the operation manual. Incorrect handling can cause damage or malfunction of machinery and equipment, etc. 2. Before removing equipment or compressed air supply/exhaust devices, shut off the air and power supplies, and exhaust compressed air from the system. Further, when restarting equipment after remounting or replacement, first confirm safety and then check the equipment for normal operation. 3. Perform work after removing residual chemicals and carefully replacing them with deionized water or air, etc. 4. Do not disassemble the product. Products which have been disassembled cannot be guaranteed. If disassembly is necessary, please contact SMC. 5. In order to obtain optimum performance from valves, perform periodic inspections to confirm that there is no leakage from valves or fittings, etc. 1. Removal of drainage Flush drainage from filters regularly. 856