CATS Aeromedical Transfer (Clinical)

Similar documents
PRACTICE GUIDELINE EM004 EMERGENCY CENTRE EQUIPMENT

Section three - DETAILED GUIDANCE FOR THE TRANSPORT TEAM

A V A L A N C H E R E S C U E

excellence in care Procedure Management of patients with difficult oxygenation. For Review Aug 2015

HOBIT Trial Checklist

Manual: Biphasic Positive Airway Pressure (BiPAP) Ventilation

VENTILATORS PURPOSE OBJECTIVES

V8600 Ventilator. Integrated Invasive & Noninvasive Ventilation

Difficult Oxygenation Distribution: Sydney X Illawarra X Orange X

NOTE: If not used, provider must document reason(s) for deferring mechanical ventilation in a patient with an advanced airway

Oxylog 3000 plus Emergency & Transport Ventilation

Instructions/Procedure for Use of the Speaking Valve

CPAP Devices - Masks - Accessories for respiratory assistance in CPAP

Tracheostomy and Ventilator Education Program Module 11: Emergency Preparedness

Mechanical Ventilation

CCAT Mechanical Ventilation Clinical Practice Guideline

Operation and Maintenance of the EPV200 Portable Ventilator

MANAGEMENT OF LIQUID NITROGEN

Minimum equipment list for cardiopulmonary resuscitation Primary dental care

RFFS Procedures. Airside Operational Instruction 18. Content

Test Bank for Pilbeams Mechanical Ventilation Physiological and Clinical Applications 6th Edition by Cairo

3100A Competency Exam

Section 2.9 Decannulation

DEPARTMENT OF THE AIR FORCE AEROSPACE SUSTAINMENT DIRECTORATE (AFMC) ROBINS AIR FORCE BASE GEORGIA

The Crossvent 2i+ 2. Ventilator Concept (brief theory of operation and features)

OXY-VIVA 3 RESUSCITATOR OPERATING INSTRUCTIONS

Technical Data and Specifications

Virginia Beach EMS. Oxylator EMX. Debra H. Brennaman, RN, MPA, NREMT-P

Hospital and Transport for Controlled Breathing

EMS INTER-FACILITY TRANSPORT WITH MECHANICAL VENTILATOR COURSE OBJECTIVES

Oxylog 2000 plus. Step up your performance. Emergency Care Perioperative Care Critical Care Perinatal Care Home Care

Medical Issues in Aviation

ila ACTIVVE SYSTEM PLATFORM

Learning objectives. First Response Learning Module 2 Based on ILCOR and ANZCOR 2016

First Response Learning Module 2 Based on ILCOR and ANZCOR Victorian Newborn Resuscitation Project Updated March 2018

patient education program 4156 South 52 nd Street, Omaha, NE ChildrensOmaha.org/HomeHealthcare

Medical Instruments in the Developing World

OXYGEN THERAPY. (Non-invasive O2 therapy in patient >8yrs)

AIRPLANE AIRWORTHINESS; TRANSPORT CATEGORIES SUPPLEMENTAL OXYGEN REQUIREMENTS

Standard Operating Procedure

Doing Prehospital Medicine what s it like? John Glen Consultant, Anaesthesia & ICM, Glan Clwyd Hospital Clinical Lead, Helimed 61 (Caernarfon)

Equipment and supplies - pediatric intensive care service.

Endotracheal Suctioning: In Line ETT

EMERGENCY EQUIPMENT TROLLEY DAILY SIGNATURE SHEET. Please refer to the Emergency Equipment stock poster for detailed information

HONG KONG COLLEGE OF ANAESTHESIOLOGISTS TECHNICAL GUIDINES RECOMMENDATIONS ON CHECKING ANAESTHESIA DELIVERY SYSTEMS

AT Kelly Torso. Directions for Use

Chapter 2 Preparations for Tank Cleaning Work

Procedure: 1. The Crew Lead (Crew Member II or Crew Chief) will have ultimate responsibility for the Pre- Departure Checklist / Procedure.

PICU Resident Self-Study Tutorial The Basic Physics of Oxygen Transport. I was told that there would be no math!

Quick Response Pneupac VR1 Emergency Ventilator AIRWAYMANAGEMENT

CARDIOHELP System designed to save lives

Digital drainage systems. ATMOS Thorax COMFORT SAFETY FLEXIBILITY MOBILITY

Clinical Skills. Administering Oxygen

I. Subject: Medical Gas Systems Utility Failure Interim Procedure III. Purpose:

Installation, Operation and Maintenance Instructions for Mild Steel Buffer Vessel

TSS21 Sealed Thermostatic Steam Tracer Trap

CHEM 1211 Gases-Part 1 Worksheet 4-2. Name(s):

Chapter 4: Ventilation Test Bank MULTIPLE CHOICE

Recommendations on Checking Anaesthesia Delivery Systems

Lung Volumes and Capacities

Virginia Office of Emergency Medical Services Scope of Practice - Procedures for EMS Personnel

Automatic Transport Ventilator

FITTING INSTRUCTIONS. Atom V808 strapping of patient harness on the Stryker stretcher

SAFETY INFORMATION NOTICE

Gas exchange measurement in module M- COVX

DIVING PHYSICS EXAMPLE QUESTIONS

The right atmosphere for health. A system for medical gas supply

Anaesthetic infrastructure and supplies

ANNEX AMENDMENTS TO THE INTERNATIONAL CODE FOR FIRE SAFETY SYSTEMS (FSS CODE) CHAPTER 15 INERT GAS SYSTEMS

Solutions for transcutaneous monitoring

Emergency Transport and Ventilation

Recommended Minimum Facilities for Safe Anaesthetic Practice in Operating Suites

Oxylog Better to have one. Because you care. Emergency Care Perioperative Care Critical Care Perinatal Care Home Care

HELICOPTER SAFETY. Escambia County, Florida - ALS/BLS Medical Protocol

Aeromedical Evacuation

OFF OFFICE OF THE CHIEF OF RESCUE

Surgical Care at the District Hospital. EMERGENCY & ESSENTIAL SURGICAL CARE

HAMILTON-T1 Intelligent transport ventilation for armed forces

AT Kelly Torso. Directions for Use

The Airfield Volunteer Fire Service

OVERVIEW pg 3. Major Points to Consider pg 3 Minor Points to Consider pg 3. INSTRUCTIONS pg 4

Servo UNIVERSAL ADVANCED VENTILATION PLATFORM ALL PATIENT CATEGORIES

TUBINGS / CONNECTION PIECES

MEDAP-MOBILE GAS SUPPLY

Drum / cylinder handling

Operation and Maintenance of the MCV100 and MCV100-B Portable Ventilator

Operation of Oxylog 3000 ventilator

SATURN EVO COLOR A N A E S T H E S I A S Y S T E M. Manufacturer of high quality anaesthesia products

Bunnell LifePulse HFV Quick Reference Guide # Bunnell Incorporated

AIR CONDITIONING AND PRESSURIZATION CONTROLS AND INDICATORS

Airox Supportair Ventilator

Greater Manchester, High Peak and East Cheshire Neonatal Transport Service

High Altitude Concerns

Aeromedical Evacuation

IEC C LASSIFICATIONS:

VIMA. (Volatile Induction and Maintenance Anesthesia) How and Why. James H. Philip M.E.(E), M.D.

ATMOSPHERE AND PHYSIOLOGICAL REQUIREMENTS

Section 2: Using the Invasive Blood Pressure Module - An Introduction

Understanding Tracheostomy Care for your Child

On the Go with Oxygen

Transcription:

Children s Acute Transport Service CATS Aeromedical Transfer (Clinical) Document Control Information Author Lutman Author Position Head of Clinical Service Document Owner Polke Document Owner Position CATS Co-ordinator Document Version Version 1.3 Replaces Version 1.2 July 2013 First Introduced July 2009 Routine Review Schedule Every 2 years Active Date January 2016 Next Review January 2018 Applicable to All CATS staff Printed copies of this document may not be up to date. Always obtain the most recent version from www.cats.nhs.uk

CATS Aeromedical Transfer (Clinical) Scope This document describes the procedures to be followed for all air transfers. (see also: General Aeromedical Considerations, Aeromedical Decision Making, Use of Inhaled NO aeromedical, Use of SAR for Air Transfers) Guidance A CATS consultant must approve all air transfers before transport is booked. Air transfer should be considered for all referrals with a one-way journey time in excess of 2.5 hours. Air transfer will usually be necessary when retrieving from a centre separated by water (e.g. Channel Islands, Ireland etc.). Methods Helicopter (RW) are unpressurised and can operate from landing sites close to the hospital in many cases. This advantage means that they may be suitable for destinations such as into the Southwest or Midlands. They have more weather restrictions than fixed wing aircraft (safe flight planning for weather is the responsibility of the pilot in command). Poor visibility and freezing conditions can prevent helicopter transport. Bristow provides these transports with Search and Rescue Aircraft which will usually depart from Regents Park (military landing site). The helicopter environment makes monitoring and communication very difficult. Flight following will be provided by the ARCC/MRCC Kinloss/Swannick. Fixed wing (FW) are pressurised but require a landing facility. This restriction tends to reduce time advantage and results in fixed wing aircraft being reserved for more distant destinations in the North or Channel Isles. They have relatively fewer weather restrictions (safe flight planning for weather is the responsibility of the pilot in command). Fixed wing flights usually depart from London City Airport, Biggin Hill airport, Stapleford Airfield or Northolt (See Maps). Flight following will be provided by the aircraft operator. Preparation Teams should coordinate with the duty consultant, flight operator and duty administrator to formulate a logistical plan. The duty administrator will provide logistical support for connecting transportation and liaise with flight operators. The CATS team leader will formulate a medical plan with the duty consultant and oversee the flight kit and consumables package Page 2 of 6

Gas supply (oxygen and air) The FW aircraft may carry oxygen on board. However this must be confirmed when requesting the aircraft. Check gas connector compatibility. Calculation: Oxygen use must be calculated (please use oxygen calculation graph) with sufficient safety margin. Babypac For non-active PEEP modes assume 5 L/min. If Active PEEP is used, then consumption goes up to 11 L/min. Oxylog 3000 Check consumption using referring patient settings via the display interface. Additionally consider power and number of backup batteries required. STEP 1: Estimate the total air journey time for the patient STEP 2: Add 1 hour for loading, unloading and taxi time STEP 3: To provide a margin of error, carry twice the calculated volume on transport. MV (see above) X total air journey time in minutes (including 1 hour extra) X 2 Cylinders Oxygen cylinders come in a number of sizes and fittings. Never leave base without at least two cylinders, even if you have calculated that one will be sufficient. The following sizes are suitable for transport: D: 340L; suitable for moving between ambulance/plane and ward. CD: 460L; integral Schraeder valve. E: 640L; good for maintenance on board aircraft, fitted in the transport incubators ZD: 605L; standard CATS portable cylinder Monitoring Philips IntelliVue X2 is the default monitor. Consider spare lithium batteries in the battery carry case. Spare batteries to be carried in separate secure case Carry the MRX defibrillator/pacer and backup monitoring cables. There may not be any facility to provide back-up power on the aircraft, plug in to charge when ever the opportunity presents. Infusion Pumps Carry six pumps. You should ensure that there is one spare so that substitution may be made in the case of failure of a pump supplying a critical infusion. Page 3 of 6

Aerosled This consists of three parts, the Clip Deck (interface), the Aerosled (patient stretcher) and the Aerosled Bridge (monitor/vent equipment restraint). Please remember to take all the required components. The patient will be packaged on the Aerosled and the equipment restrained using the flight bridge. The Aerosled is usually attached to an aircraft base unit (FW), a Clip Deck (Non CATS ambulance trolley interface/bristow Helicopter) or the CATS trolley. Check that the Aerosled has been matched to the aircraft base unit in use before departure. Non-standard interfacing can be achieved using the Clip Deck. Staff Dress All staff must comply with the uniform policy. Staff are advised to take cold weather gear for aeromedical transports. Safety Do not at any time take any personal risks during an air transfer. You must follow the direction of the aircrew to the letter. In particular do no approach any aircraft until invited to by the crew. Stabilisation of a Patient for Air Transport Airway and ventilation Intubation If you are in any doubt about the patient s respiratory status, you should intubate. Intubation in-flight could be technically very difficult and access to the patient/monitoring may be quite limited. Fixation of ETT Melbourne strapping must be employed to secure all ETTs Gas expansion See below for details. Circulatory support and Infusions Access Two points of intravenous/ intraosseous access. Inotropes Each inotrope used or anticipated should be prepared as an infusion in sufficient quantities to last twice the anticipated journey time. Careful note should be taken of the time infusions are started and regular checks made on the progress of the infusion, as it is difficult to hear the pump alarms above the aircraft noise. Page 4 of 6

Decompression of Trapped Gas ETT cuff Manometry should be used on cuffed tubes. Bear in mind that an increase in altitude will cause cuff expansion which may risk tracheal mucosal integrity and descent will cause cuff deflation which may risk aspiration. Chest All pneumothoraces should be drained and connected to a heimlich valve for transfer. Head Patients with an open head injury or recent neurosurgery (48 hours) should be transferred at sea level cabin pressure. Abdomen A naso/oro gastric tube must be passed in all patients. This should be left on free drainage in order to decompress the stomach as the external pressure drops. Free air in the peritoneal cavity should be drained. Urinary Catheters Ensure that cuffs are water filled (as is standard practice) to avoid expansion problems. Vacuum Mattress If used will require suction prior to loading/unloading. Thermal regulation Attention must be paid to the patients temperature like any other retrieval. However there is likely to be more time spent outside (Transferring hosp-ambulance, ambulance-aircraft etc.) which may become especially significant on cold days. Environmental temperature monitoring is undertaken at CATS. Physical safety Patient Every effort should be made to secure the patient whilst allowing sufficient access for clinical support. Babies <5kg transported in the Pod should be placed on the vacuum mattress and nested/packed in with nappies and blankets. Larger children should be transported with the Ambulance Child Restraint (ACR) and the largest vacuum mattress, which can be secured to the aircraft stretcher. Staff All staff must take responsibility for their own safety. In particular aircraft must not be approached without explicit instructions from the pilots, aircrew or airfield ground staff. Approved lifting techniques must be employed when moving the incubator on or off the aircraft. When you board the aircraft, the flight crew will brief you on safety procedures. You must give this your full attention and ask questions if you are unsure. Page 5 of 6

In the event of decompression you must ensure that you secure your own oxygen supply before tending to the patient you will be of no use if you are unconscious! Equipment All equipment must be secured for take-off and landing and also during flight when not in use. It is never sufficient to hold onto something that might become a dangerous projectile in an emergency situation. Physiology Trapped gases Enclosed gases obey Boyle s law: at constant temperature as the atmospheric pressure decreases the volume of enclosed gases increases. The table below illustrates the expected changes as an aeroplane ascends: 1.1. Sea level Altitude 0 ft 5,000 ft 8,000 ft Atmosphere 1.0 0.83 0.77 Volume 1.00 1.20 1.33 18,000 ft 0.50 2.00 Oxygenation The partial pressure of oxygen in the alveolus (P A O 2 ) is approximately equal to the arterial partial pressure of oxygen (P a O 2 ) in a patient with normal lungs. P A O 2 can be derived by subtracting the partial pressure of water in the saturated gas and the partial pressure of CO 2 displacing the inspired gas at alveolar level. As P a O 2 is equal to atmospheric pressure (+ Pi when intubated) multiplied by its fractional content in the inspired gas. Therefore it can be seen that as atmospheric pressure drops (with altitude) so will P A O 2 and therefore P a O 2. As a rough guide P a O 2 will halve during the ascent to 8000 ft in an unpressurised aircraft. Page 6 of 6