Nitrogen Supply System

Similar documents
Installation, Operation, and Maintenance Manual Parker Balston Model N2-04 Nitrogen Generator

CSA Sample Draw Aspirator Adapter Operator s Manual

Model No Product Name Handpiece Only Complete System

OPERATION MANUAL NTF-15

OPERATION MANUAL NTF-60 Plus

453 Series Steam Heated Vaporizing Regulator

CF-SERIES HIGH FLOW REGULATORS

Accu-Tab Systems 1000 Series by Axiall Corporation

Oxygen Concentrator. Installation and Operation Manual. ClearWater Tech, LLC. Integrated Ozone Systems

4-in-1 Professional Inflator Kit

92831 TEL: (714) FAX:

MODEL CALIBRATION GAS DELIVERY SYSTEM

Nitrogen Advantage. Better Tire Pressure Retention. Improved Fuel Economy. Extended Tread Life. Elimination of Oxidation. Reduction in Tire Failures

Windy City II. User instruction manual WARNING: Fill pressure: 200 bar (approximately 2,900 psi)

RK-IR Sample Draw Aspirator Adapter Operator s Manual

ATD /8 x 50 Retractable Air Hose Reel Owner s Manual

Technical Information

Accu-Tab Systems 2000 P Series by Axiall Corporation

SERVICE MANUAL MODEL BA100BMST 100 SCFM PORTABLE AIR PANEL

TECHNICAL INFORMATION

RK LEL Sample Draw Aspirator Adapter Operator s Manual

SERVICE MANUAL MODEL BA050BMST BREATHING AIR PANEL

USER S MANUAL. N2-MISTRAL-0 / 25 L/min NITROGEN GENERATOR. Rev. 3 - August 2008

D Series Air and Water Kit Part# 02550

AIR HAMMERS MODEL NO: CAT138/CAT139 OPERATING & MAINTENANCE INSTRUCTIONS PART NO: / GC064

Operating Manual. Model BAC-30RT30/BAC-30DC

NB/NBR NITROGEN BOOSTER FOR AVIATION SERVICE

Installation Instructions Air Compressor Part # 2780, 2781

J Air and Water Kit Instructions Part# 02584

Operating Instructions for BAIR22-6 AIR-POWERED CRIMPING TOOL

ROPV R40 E Series User Manual

HUBEN K1 Pre-charged Pneumatic Air Rifle Owner s Manual

MODEL NUMBER: AS18-2 USER GUIDE

Model ASSEMBLY and OPERATING INSTRUCTIONS

Installation & Instruction Manual For Portable Series R.O. units:

P5523. Users Manual. Liquid to Gas Separator. Test Equipment Depot Washington Street Melrose, MA TestEquipmentDepot.

USER MANUAL FLOW SELECTOR PM1000 SAVE THESE INSTRUCTIONS. Federal (USA) law restricts this device to sale by or on the order of a physician.

Manual. FRESH AERO OneOP Model PC (Portable Compressors) Tire Inflator. Where Imagination Meets Innovation

User Instruction Manual

Yoke Block Instruction Manual

G7S Hand Pump Owner s Manual

92831 TEL: (714) FAX:

Acid- Rite ph Adjustment System 2500 by Axiall, a Westlake Company

TECHNICAL INFORMATION

Accu-Tab PowerBase 3012AT by Axiall Corporation

3" UC Ultra-Chuck Durable Lightweight Air Inflated Bladder Chuck Operation/Repair Manual. (76.2 mm) DOUBLE E COMPANY, INC.

TOP VALVE. Pat. #5,857,486 & 5,944,050. Mid-Range Pressure PSIG Back Pressure and Pressure Relief Valves. Instruction Manual

Operating Manual. Models AQT-02 & AQT-COO2 Manual No. MON004 (Rev 2 April 2000)

GETZ EQUIPMENT INNOVATORS PART NO.: 9G59554 MODEL: MS 36 SC-R HYDROSTATIC TEST PUMP

AC1810 / AC1810-A TECHNICAL SPECIFICATIONS. Operating Pressure psi ( kgs/cm²) [AC1810] Displacement. Net Weight

42045 Heavy Duty ADA Base Model Kit: 85/105 PSI (ADA Compressor Only) Heavy Duty ADA Base Model Kit: 110/145 PSI (ADA Compressor Only)

NTO-200 Operation Manual

PRODUCT OPERATING MANUAL

SIX R (P ) AND SEVEN R (P ) POSITION CYLINDERS Service Information

Portable Compressed CO 2 Regulator

SDS -Series 4C-D201/-D202 Supplemental Drying System User s Manual

Model C Pipe Line Strainer 6, 8 & 10 Inch (DN150, DN200 & DN250) 250 psi (17,2) General Description. Technical Data. Page of 6 MAY, 2006 TFP1644

SERVICE MANUAL MODEL BA600AMST-S1 BREATHING AIR PANEL

VOLUME BOOSTER RELAYS YT-300 / 305 SERIES

INSTALLATION. and INSTRUCTION MANUAL. for QUALITY AIR BREATHING SYSTEMS. Model 50-P-Mini Portable Systems Outfitted with ABM-725 Monitor

SERVICE MANUAL MODEL BA020ANM-S1 BREATHING AIR PANEL

Operating and Maintenance Instructions 3/8-inch Air Ratchet Wrench Model JNS-5052

Yoke Block Instruction Manual

97C COMPRESSOR KIT 12V PART NO C COMPRESSOR KIT 24V PART NO C COMPRESSOR KIT PART NO

PERSONAL AIR BREATHING UNIT

/ Air Line Kit AL - M1202. / OPERATION MANUAL P1 - P9 / English P11 - P19 OM-K0651

ACRYLIC FLOW METERS 0-30, 0-70 & LPM

BS Series Basket Strainer

FILTER REGULATORS MODEL NO: CAT155 & CAT156 FITTING & MAINTENANCE INSTRUCTIONS PART NO: & ORIGINAL INSTRUCTIONS

URC Voltage Sensor SEN-VOLT for use with MRX units containing sensor ports

CUT OFF TOOL MODEL: CAT113

AWG Fittings LLC. Pressure Relief Valve Up to 250 PSI. Product Number Read this instruction manual before use.

FlashGARD HP Reverse Osmosis Filtration System Model Number FSTMO75 Part Number

MODEL Maverick Heavy Duty Aerosol Compressor Operator s Manual

BREATHING AIR PURIFIER

OWNER S MANUAL. Table of Contents

SERVICE MANUAL MODEL BA020AMST BREATHING AIR PANEL

Operation Manual. O2 Quickstick. Oxygen Analyzer

AIR HYDRAULIC RIVETER

INSTALLATION & MAINTENANCE INSTRUCTIONS DESCRIPTION SPECIFICATIONS. CE (EMC) Compliant

Model B-1 Pipe Line Strainer 3, 4, 6 & 8 Inch (DN80, DN100, DN150 & DN200) 175 psi (12,1 bar) General Description. Technical Data

250C-IG COMPRESSOR KIT 12V PART NO C-IG COMPRESSOR KIT 24V PART NO

Installation, Operation and Maintenance Manual

ULTRA QUIET & OIL FREE

PORTABLE AFTERCOOLER MODEL CA-700 PORTABLE AFTERCOOLER/FILTER AFTERCOOLER OPERATION MANUAL ORIGINAL INSTRUCTIONS

TactAir PCP Fill Kit/Adapter. Operation Manual

250C-IG COMPRESSOR KIT 12V PART NO C-IG COMPRESSOR KIT 24V PART NO

SPECIFICATIONS Type: Twin stack, single phase Tank: 4 gallon Air Output: PSI; PSI Max PSI: 125 PSI HP: 1.

Installation, Operation, and Maintenance Manual

Freedom8 ShoeBox Compressor Manual

HAYWARD FLOW CONTROL TFS SERIES FLOW METER INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS

PLEASE READ CAREFULLY BEFORE INSTALLING OR USING MEGA POOL SAVER MPS 1100

INSTRUCTION MANUAL MP4AR Remote Convection Gauge Range: 1 x 10-3 Torr to 1 x 10+3 Torr

Parts Manual. Frusheez Machines

Tactical Sniper air rifle & carbine

100C Air Compressor Kit

ORBITAL AIR SANDER. Owner s Manual

3800 SERIES END SUCTION PUMP REPAIR PARTS INDEX. Model Model 3804

Copyright Trek Bicycle Corporation 2005 All rights reserved

User Operation Manual and Safety Instructions

Transcription:

ATMOSCOPE Nitrogen Supply System NS500 Users Guide Copyright 2001 EDSYN, INC. ATMOSCOPE Nitrogen Supply Systems

TABLE OF CONTENTS Introduction............................. 3 General Information....................... 4 Safety & Applications Information........... 5-6 Application & Installation.................. 7-9 Replacement Parts List.................... 10 Warranty Information...................... 11 Product Registration Form................. 12 User Notes.............................. 13-15 WARNING Read the Safety and Applications Information Section in the Operation and Maintenance Manual thoroughly before installing and using your ATMOSCOPE Nitrogen Supply System. 2

Introduction This manual will provide the user with the basic information to properly operate and maintain the EDSYN NS1000 & NS500 ATMOSCOPE Nitrogen Supply Systems. WARNING Failure to comply with the Application and Maintenance Guidelines, Filter Replacement Schedules, Monitoring Recommendations and Safety Guidelines contained herein and in other relevant product safety literature provided with the substances and equipment could result in risk of serious injury, fire or explosion If you encounter any difficulty operating your systems, or have any questions, call your local authorized EDSYN Distributor or contact EDSYN Applications Engineering directly at: Tel: (818) 989-2324 Service Fax: (818) 997-0460 The EDSYN ATMOSCOPE Nitrogen Supply System represent the latest technology in affordable Nitrogen Generation. These systems allow the production of nitrogen-enriched air for use in soldering applications. ENVIRONMENTAL SPECIFICATIONS Ambient Operating Temp: 0 C to 50 C Storage Temperature: -40 C to 125 C Ambient Operating Humidity: 90% relative humidity max. non-condensing Storage Humidity: 90% relative humidity max. non-condensing EDSYN, Inc. retains the right to make changes to specifications contained herein at any time, without notice. Contact your local authorized EDSYN Distributor or EDSYN, Inc. to obtain the latest specifications. Additional copies of this manual or other EDSYN literature may be obtained by contacting us at: 15958 Arminta Street Van Nuys, CA 91406 USA Tel: (818) 989-2324 Sales Fax: (818) 997-0895 Service Fax: (818) 997-0460 Web Site: www.edsyn.com Email: info@edsyn.com 2000 EDSYN Inc. 2001 3

GENERAL INFORMATION NS1000 & NS500 ATMOSCOPE Nitrogen Supply System Specifications Model Number NS1000 NS500 Max N2 Flow Rate *69 L/min *13 L/min # of soldering irons @ 99% N² *12 *2 Max Input Air pressure Power source 8.5 bar 8.5 bar 123 psi 123 psi No Electrical power required Outline Dimensions 720 x 270 x 300 mm 420 x 180 x 220 mm 28.3 x 10.6 x 11.8 16.5 x 7.0 x 8.66 Weight 18 kg / 39.69 lbs 8.5 kg / 18.75 lbs *These figures are based on 99 % nitrogen enriched airflow at 7 bar/101.5 psi, temp 25 C PERFORMANCE (based on new membrane performance) MODEL % OF NITROGEN FLOW RATE OF OUTPUT L/MIN 99.9 8.8 99 24.1 98 37 NS1000 97 47 96 58 95 69 99.9 2 99 5 NS500 98 7 97 9 96 11 95 13 Figures based on dry, clean air pressure of 7 bar/101.5 psi, temp 25 C 4

SAFETY & APPLICATIONS INFORMATION EDSYN ATMOSCOPE Nitrogen Supply Systems are designed to utilize the latest polyimide hollow fiber membrane technology to allow the generation of nitrogen from compressed air. The input compressed air pressure must not exceed 8.5 bar/123 psi, it is important to ensure all compressed air hoses and fittings are maintained and in good working order. DISCLAIMER EDSYN, Inc. hereby disclaims all responsibility for any personal injury, property damage, fine, citation or penalty imposed by any government or private entity which results from any use, misuse or mis-application of this product, failure of the user to regularly maintain the product according to the recommended guidelines, or failure to adequately monitor input and/or output air and the ambient workplace environment for the presence of harmful levels of gases, fumes and particulates. Compliance with all applicable environmental and personnel safety regulations is the sole responsibility of the user and adequate selfmonitoring of exhaust gases released into the atmosphere or the workplace as well as monitoring of the ambient workplace air is strongly recommended. WARNING Failure to comply with the Application and Maintenance Guidelines, Filter Replacement Schedules, Monitoring Recommendations and Safety Guidelines contained herein and in other relevant product safety literature provided with the substances and equipment could result in risk of serious injury, fire or explosion To insure continued effective performance, the following guidelines must be followed. 5

SAFETY & APPLICATIONS INFORMATION The basic principle of these products are that as compressed air flows through the hollow fibers contained within the membrane body, oxygen is selectively allowed to permeate through the fibre wall to atmosphere. This results in a nitrogen rich gas being obtained at the output of the hollow fibre membrane. Oxygen-enriched air Compressed air Nitrogen gas Permeation speed H 2 O, He, Fast CO 2, O 2, Medium Ar, N 2, Slow There are three main factors determining the removal of oxygen from the nitrogen rich air. a) Temperature - if this is maintained at close to 25 C then it can be ruled out of further calculations of oxygen. b) Flow rate - increasing the flow rate through the unit increases the level of oxygen present in the output. c) Pressure - increasing the pressure reduces the level of oxygen present in the output. FEATURES The NS1000 and NS500 are able to achieve Nitrogen purities of up to 99.9% on demand as stand alone units. Extremely quick set-up times, because the system can be connected into an existing compressed airline it can be positioned in minutes and is very portable. Low running costs: the NS1000 and NS500 require no power source other than compressed air. Using conventional bottled nitrogen can result in a nitrogen imbalance in the workplace. This system recycles oxygen maintaining the correct balance of oxygen and nitrogen in the workplace. The unit contains no moving parts so does not give rise to noise or dust. 6

APPLICATIONS / INSTALLATION The NS1000 and NS500 are designed to be used close to the process workbench. The following are recommended guidelines for setting up your EDSYN ATMOSCOPE Nitrogen Supply Systems. If you have any specific questions that this section does not cover, please consult your EDSYN Representative or call EDSYN, Inc. directly. 1. PLACEMENT There are two major considerations that need to be addressed for proper placement of the ATMOSCOPE Nitrogen Supply System: 1) Unit Location: The ATMOSCOPE Nitrogen Supply System unit should be located so that it will not block aisleways or impede normal operating traffic or material handling pathways. It is important to position the unit in such a way that allows for proper clearance to remove the access cover and replace the filters as needed. 2) Proximity to the work area: The ATMOSCOPE Nitrogen Supply System should be placed as close to the work area as possible. INSTALLATION SET UP Connection and Operation The unit is connected to a compressed airline max pressure 8.5 bar/123 psi. Ensure that the compressor is switched off while installing. Compressed Air Supply Details: Supply pressures should be regulated to the nitrogen supply system at a lower value than the compressors hysteresis to ensure constant operating pressure. The air supply should have no chemical, lubricant or particulate matter added to the airline. It is however acceptable to use both dry and lubricated compressors. Connection to the airline is made via ¼ BSP female fitting on the NS1000 and 1/8 BSP on the NS500. Output of nitrogen rich air is also via the same size fittings. *EDSYN recommends that you add internally to the system, a membrane dryer to be in line with incoming compressed air supply, (see optional items list in manual). 7

INSTALLATION SET UP CONTINUED Startup 1. Ensure the system pressure regulator is closed 2. Close off the flow regulator 3. Turn-on the compressed air to the unit 4. Open the system pressure regulator until gauge reads a nominal 7 bar/101.5 psi 5. Open flow rate regulator until desired rate is achieved 6. Run for 20-60 mins to allow system to stabilize before use. Shut Down 1. Close compressed air feed to unit 2. Leave open flow regulator 3. When nitrogen has stopped flowing from outlet, close system regulator flow regulator Once running the level of nitrogen can be controlled by both the flow rate regulator and the pressure regulator. Maintenance The units require no maintenance other than the replacement of the internal compressed air filters on a once yearly basis, or sooner depending on the quality of the input compressed air. The filters are essential to maintain the integrity of the membrane. The membrane will also need to be replaced from time to time, this will depend on quality of the input compressed air, product usage and purity of nitrogen required (approx membrane life based on average use 18-24 months). Air Filter Replacement procedure: 1. Remove screws from rear panel 2. Locate 3 stage filter module on left hand side of case 3. Unscrew each poly carbonate bowl in an counter-clockwise direction and remove 4. Remove filter element by undoing locking screw from underside 5. Replace new element by following notes 1-4 in reverse. 8

INSTALLATION SET UP CONTINUED Membrane Replacement procedure 1. ENSURE UNIT IS DISCONNECTED FROM AIR SUPPLY! 2. Remove screws from rear panel 3. Locate 2 x nitrogen separator modules on right hand side 4. Remove retaining brackets to free nitrogen separators 5. Disconnect pipes from both nitrogen separators at top and bottom. This is done by pushing in surrounding flange of fitting and pulling out pipe. 6. Remove nitrogen separators from case 7. Fit new separators by following points 2-6 in reverse. Ensure that when fitting pipes into connectors they are securely located. 9

MAINTENANCE & REPLACEMENT PARTS NS 1000 Replacement Parts List Description Part Number Note Nitrogen Separator SR832 Membrane Dryer SR834 Optional for Areas of high humidity Gauge SR836 1 Stage filter SR837 Element for SR837 SR838 2 stage filter SR839 Element for SR839 SR840 3 Stage filter SR841 Element for SR841 SR842 Pressure Regulator SR843 N2 Flow Regulator SR845 Carbon Bed Filter SR846 Optional for very low odor applications Bracket for SR846 SR847 Element for SR846 SR848 NS 500 Replacements Parts List Description Part Number Note Nitrogen Separator SR831 Membrane Dryer SR833 Optional for Areas of high humidity Gauge SR835 1 Stage filter SR837 Element for SR837 SR838 2 stage filter SR839 Element for SR839 SR840 3 Stage filter SR841 Element for SR841 SR842 Pressure Regulator SR849 N2 Flow Regulator SR844 Carbon Bed Filter SR846 Optional for very low odor applications Bracket for SR846 SR847 Element for SR846 SR848 10

LIMITED WARRANTY EDSYN warrants to the first user that this equipment will be free of defects in materials and workmanship for a period of one (1) year from the date of receipt by such user. This warranty does not cover repair or replacement required as a result of misuse, mishandling or improper storage. Failure to perform recommended routine maintenance, alterations or repairs made other than in accordance with EDSYN s directions, or removal or alteration of identification plates in any way will void this warranty. This warranty is available only to the first user, but the exclusions and limitations herein apply to all persons and entities. This warranty does not apply to consumable items such as filters, elements & hoses. EDSYN MAKES NO OTHER WARRANTY, EXPRESS OR IMPLIED, AND MAKES NO WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. EDSYN will, at its option, repair or replace any defective equipment or parts at its facility or other location approved by it at no charge to user, or provide parts without charge for installation by the user in the field at user s expense and risk. User will be responsible for all costs of shipping equipment to EDSYN or other location for warranty service. EXCEPT FOR THE REMEDY ABOVE DESCRIBED, UNLESS OTHERWISE REQUIRED BY APPLICABLE LAW, EDSYN WILL HAVE NO OTHER OBLIGATION WITH REGARD TO ANY BREACH OF WARRANTY OR OTHER CLAIM WITH RESPECT TO THE EQUIPMENT OR LIABILITY FOR ANY DIRECT, INDIRECT CONSEQUENTIAL, OR INCIDENTAL LOSS OR DAMAGE CAUSED BY OR OCCURRING IN CONNECTION WITH ANY OF THE EQUIPMENT. To obtain Warranty Service, contact your local authorized EDSYN Distributor or you may also contact EDSYN, Inc. at: 15958 Arminta St. Van Nuys, CA 91406 USA Tel: (818) 989-2324 Service Fax: (818) 997-0895 Do not return defective parts or equipment to EDSYN or your local authorized distributor without obtaining prior authorization. Any warranty or other claim with respect to the equipment must be made in writing delivered to EDSYN (or your local authorized EDSYN Distributor outside the US) within a reasonable time of the expiration date of this warranty with sufficient evidence of purchase and date of receipt, otherwise user s rights under this warranty shall be deemed waived. 11

WARRANTY REGISTRATION CARD To register your purchase with EDSYN, Inc., please fill in the form below and mail or FAX to EDSYN, Inc. 15958 Arminta Street Van Nuys, CA 91406, USA Tel: (818) 989-2324 Service Fax: (818) 997-0460 Web Site: www.edsyn.com Email: info@edsyn.com EDSYN Model and #: Serial #: Date Purchased: Purchased From: Address: City: State: Zip: Country: Tel.#: Fax#: Internet Address: Name: Authorized Signature, Title 12

USER NOTES 13

USER NOTES 14

USER NOTES 15

15958 Arminta Street Van Nuys, CA 91406 USA Tel: (818) 989-2324 Sales Fax: (818) 997-0895 Service Fax: (818) 997-0460 Web Site: www.edsyn.com Email: info@edsyn.com Copyright 2001 EDSYN, INC. NS500 ATMOSCOPE Nitrogen Supply System