NN- NAVY EXPERIMENTAL DIVING UNIT SECNIALRPOR NO. 6-9 NAV EPEIMETAL DI VING UIT~ TIC-99 DTIC QUAJLIXDISPECTED X

Similar documents
DTIC 1111II IGI~ ~I HI II17 04 AD-A NAVY EXPERIMENTAL DIVING UNIT REPORT NO OMMERCIALLY AVAILABLE IDI SCUBA REGULATORE

NAVY EXPERIMENTAL DIVING UNITC OTIC_

D TIC 0 F U AD-A IllllllIII ELECTE f1 JUN2 71M4 DEPARTMENT OF THE NAVY

AVExPERIMENTAL DVING UNIT

EVALUATION OF THE KMS 48 FULL FACE MASK WITH THE VIPER VERY SHALLOW WATER UNDERWATER BREATHING APPARATUS

AD-A Ott, pp, ELECTE NAVY EXPERIMENTAL DIVING UNIT

AD-A DIVING UNIT NAVY EXPERI:MENTAL ...DTIC ILKICT[ 000 CTL14 Ift,

POTENTIAL BENEFITS OF NAVY DIVE COMPUTER USE IN SHIPS HUSBANDRY DIVING: ANALYSIS OF DIVES CONDUCTED ON THE USS RONALD REAGAN (CVN-76)

EVALUATION OF INTRAVENOUS THERAPY DEVICES IN THE HYPERBARIC CHAMBER

EVALUATION OF THE KMS 48 FULL FACE MASK CONFIGURED FOR OPEN CIRCUIT UBA WITH CROSSOVER TO EITHER MK 16 MOD 0 UBA OR MK 25 UBA

200602q PULMONARY FUNCTION AFTER OXYGEN-ACCELERATED DECOMPRESSIONS FROM REPETITIVE SUB-SATURATION AIR DIVES

Design Of Semi-Closed Rebreathers To Minimize Variations In Circuit Oxygen Levels

ANALYSIS OF GASES PRODUCED BY THREE UNDERWATER CUTTING DEVICES

:Q WfiEi~RW DIVING UNIT~

XVAL-HE-4B: A MAXIMUM PERMISSIBLE TISSUE TENSION TABLE FOR REAL-TIME THALMANN ALGORITHM SUPPORT OF CONSTANT 1.3 ATM PO 2 -IN-HELIUM DIVING TO 200 FSW

TECHNICAL REPORT No MANNED EVALUATION OF THE CARLETON 1.3 ATA P0 2 PRIMARY ELECTRONICS ASSEMBLY WITH THE MK 16 UNDERWATER BREATHING APPARATUS

DEPARTMENT OF THE NAVY NAVY EXPERIMENTAL DIVING UNIT PANAMA CITY. FLORIDA NAVY EXPERIMENTAL DIVING -UNIT REPORT NO.

Appendix Breathing Gas Requirements EXO Balance Regulator Full-Face Mask

NONIII F/S 13/10 EVALUATION OF ME 12 SURFACE-SUPPORTED DIVING SYSTEM (,SSDS) MODI-ETCIUI JUN 81 E H PAHL UNCLASSIFIED NEDU-7-81

UNMANNED TEST AND EVALUATION OF THE TELEDYNE ANALYTICAL INSTRUMENTS R-10DN OXYGEN SENSOR FOR USE IN THE MK 16 MOD 1 UNDERWATER BREATHING APPARATUS

AFRL-RH-WP-TR

MK 15 MOD 0 ALTERNATE CARBON DIOXIDE

DEPARTMENT OF THE NAVY NAVY EXPERIMENTAL DIVING UNIT PANAMA CITY, FLORIDA Ill) REPORT NO t GARRY ASHTON JOSEPH J.

CD CD. This document has been approved for public rel:oz- cd sc!"; i ~i distribution is unlimited. NAVY EXPERIMENTAL DIVING UNIT

DEPARTMENT OF THE NAVY NAVY EXPERIMENTAL DIVING UNIT Panama City, Florida NAVY EXPERIMENTAL DIVING UNIT REPORT NO. 3-79

COMPREHENSIVE PERFORMANCE LIMITS FOR DIVERS' UNDERWATER BREATHING GEAR: CONSEQUENCES OF ADOPTING DIVER-FOCUSED LIMITS

ELEDT S APR24 19 DECOMPRESSION SICKNESS AFFECTING THE TEMPOROMANDIBULAR JOINT. Author:

RESEARCH REPORT 341. Breathing performance of Octopus demand diving regulator systems HSE

VVal-79 Maximum Permissible Tissue Tension Table for Thalmann Algorithm Support of Air Diving

EELmh~hi. ,id-ai EVALUATION OF DIGITAL DIVING &JATCHES(U) NAVY i/i EXPERIMENTAL DfVING UNIT PANAMA CITY FL E S MORRISON SEP 83 NEDU-2-83

AD-A MA~f TEJTLIG F THES UPErLig073DIVING HEiUIEMI LI DIUIPC UNIT PANAMA C TY FL HJCHWAATZ U8 U 1CLA SS IF IED NEDU-1-6 F/G 6/2 ML

Examples of Carter Corrected DBDB-V Applied to Acoustic Propagation Modeling

GAS FLOWS SUPPORTING UMBILICAL DIVING - REQUIREMENTS AND MEASUREMENTS

S... q. Psychometric Evaluation of the Mindstreams Neuropsychological Screening Tool. Navy Experimental Diving Unit

'40. j 1.8. IIJI25 11= L.6l MICROCOPY RESOLUTION TEST CHART NATIONAL BUREAU OF STANDARDS 1963 A

BREATHING RPPAPTUS(UJ) NAVY EXPERIMENTAL DIVING UNIT U S U PANAMA CITY FL F K BUTLER ET AL. MAR 84 NEDU-5-94 UNCASSIFIED F/G 611 N

DIVE LAB, INC. SURFACE SUPPLY BREATHING REQUIREMENTS AND RECOMMENDATIONS FOR KIRBY MORGAN HELMETS AND BAND MASKS

NAVY EXPERIMENTAL DIVING UNIT ELECT OCT DistributiMn Unlimitod C-) DISTRIBUIfON -STATEMENT A Appsovod fag public ilocz4 0

NAVY EXPERIMENTAL DIVING UNIT

REPORT NO EVALUATION OF DIGITAL DIVING WATCHES EDWARD S. MORRISON SEPTEMBER 1983

DiVING UNIT AD-A NAVY. EXEIETL x --), IAYEXPIERIMENTAL 'DIVING UNIT CONTAMINATED WATER DIVING SYSTEM (CWDSI EVALUATION

(UNDERWATER BREATHING APPRATUS)(U) NRYY EXPERINENTRI. DIVING UNIT PAUNM CITY FL. F K BUTLER NAY 66 NEDU-6-96 UNCLAIEE F/O6 M

Development of Low Volume Shape Memory Alloy Variable Ballast System for AUV Use

Influence of Very High Breathing Resistance on Exercise Tolerance, Part 1 Dry Exercise

Scuba Regulator Freezing Chilling Facts & Risks Associated with Cold Water Diving Publication Date: April 9, 2014

UHMS/NOAA DIVING PHYSICIANS COURSE US NAVY AIR DECOMPRESSION TABLES REVIEW

Marine Physical Laboratory AD-A TEST OF NEWTONIAN GRAVITY USING DSV SEA CLIFF. MPL-U-48/91 1' -,. = June 1991 \, of California, San Diego

CHAPTER 9 $LU'HFRPSUHVVLRQ

EXPERIMENTAL DIVING UNIT PANAMA CITY FL C 0 PRESSNOO MR 87 NEDU-1-87 UNCLASIFIEDF/0 23/5 UL. -EhEI/E-/m/IE IEEE..

GRAPHICAL ANALYSIS: DECOMPRESSION TABLES AND DIVE-OUTCOME DATA

UHMS/NOAA DIVING PHYSICIANS COURSE US NAVY NO-DECOMPRESSION TABLES REVIEW

Baltic Assessment Institute

DTICD I JTMMUTON STATEMEN DIVING UNIT NAVY EXPERIMENTAL. Ditrbuio. Uli ite j N REPORT NO NAVY EXPERIMENTAL DIVING UNIT

PULMONARY EFFECTS OF EIGHT-HOUR MK16 MOD I DIVES

IIIIIIIIIIIIIIIIIIiIiiiiii

REPORT DOCUMENTATION PAGE

Remote Monitoring of Dolphins and Whales in the High Naval Activity Areas in Hawaiian Waters

Introduction. U.S. Navy Diving Manual (Mar-1970)

DTIC NAVY EXPERIMENTAL DIVING UNIT. f - IA OF01. Lfl REOT O 28. ELECTE JUN of. ~~Z~IUO~nlimited AUDIBLE RECALL DEVICE

EXECUTIVE SUMMARY USN DIVE MANUAL REVISION 7 Change A

MANNED TESTING OF STANDARD MK 25 MOD 2 PURGE PROCEDURES WITH KMS 48 FULL FACE MASK

EDITOR-IN-CHIEF CDR F. Duane Duff ASSISTANT EDITORS-IN-CHIEF

U.S. Navy Dive Computer Validation

High Frequency Acoustical Propagation and Scattering in Coastal Waters

SHOCK WAVE PROPAGATION THROUGH AERATED WATER

PULMONARY OXYGEN TOXICITY WITH EXERCISE: SINGLE MK 25 REBREATHER DIVES OR SPLIT 6-HOUR EXPO~SURES

AN EXPERIMENTAL INVESTIGATION OF SPILLING BREAKERS

Navy Shipbuilding Industrial Base

z Interim Report for May 2004 to October 2005 Aircrew Performance and Protection Branch Wright-Patterson AFB, OH AFRL-HE-WP-TP

DoD Coral Reef Protection and Management Program

23th Capita Selecta Duikgeneeskunde. Amsterdam, 03/17/2018: 21 st. Century Decompression Theory

SPECIAL REPORT No FOR ALTITUDE CHAMBER OPERATIONS. Approved By. Captain Ashton Graybiel, MC, USN Director of Research.

Characterizing The Surf Zone With Ambient Noise Measurements

FP-180 Water Motor AFFF Proportioner First Article Procedure and Evaluation. Navy Technology Center for Safety and Surviability ChemisiyDvision

University System of Maryland (USM) Dive Plan Approval Form To be submitted to the USM Scientific Diving Safety Officer

Concrete Obstacle Vulnerability

Operation and Maintenance of the EPV200 Portable Ventilator

11. TDI Semi-Closed Circuit Rebreather Diver Course, Unit Specific- DOLPHIN, RAY, Atlantis, SUBMATIX ST100 & AZIMUTH

Naval Submarine Medical Research Laboratory

DIVING UNIT NAVY EXPERIMENTAL COP, I REPORT NO ELECTE. VTH~JRIMN STATEMEN4T A hppromd lw publii sftboi * OF.

What Can the U.S. Navy Contribute to Scientific Diving?

M2.50-cal. Multishot Capabilities at the US Army Research Laboratory

Interspiro has over 60 years of experience in the design of Breathing Apparatus for demanding firefighting and diving conditions

Air-Sea Interaction Spar Buoy Systems

Subject: Progress Report CLIN 0001AB, SBIR Topic No. N Legged Vehicle for Underwater Mobile Operations

Challenges in Undersea Medicine

US NAVY DIVING PROGRAM: DIVING TO 300 FT DEPTHS USING SURFACE-SUPPLIED AND SATURATION FLY-AWAY DIVING SYSTEMS. Introduction

SUBMARINE BASE, GROTON, CONN. REPORT NUMBER 855

CHAPTER 16 %UHDWKLQJ*DV0L[LQJ3URFHGXUHV

Hydro-Thermal Vent Mapping with Multiple AUV's AZORES-2001

20. TDI Advanced Mixed Gas Closed Circuit Rebreather, Unit Specific, Ambient Pressure Inspiration & Evolution, Diver Course

DIVING PHYSICS EXAMPLE QUESTIONS

The most common terms rating air flow capacity are ICFM, FAD, ANR, SCFM or nl/min

7. TDI Advanced Wreck Diver Course

Internal Waves and Mixing in the Aegean Sea

Table of Equivalents

I EXPERIMENTAL DIVING UNIT PANAMA CITY FL H J SCHWARTZ

Paper 2.2. Operation of Ultrasonic Flow Meters at Conditions Different Than Their Calibration

Physics 7b Midterm Exam #1 Fall Name: Disc. Section SID

Classification of Mechanical Ventilators

Transcription:

NN- TEHNCA REOR NO.~U 6-9 NAVY EXPERIMENTAL DIVING UNIT SECNIALRPOR NO. 6-9 IP NAV EPEIMETAL DI VING UIT~ TIC-99 DTIC QUAJLIXDISPECTED X

DEPARTMENT OF THE NAVY NAVY EXPERIMENTAL DIVING UNIT 321 BULLFINCH ROAD PANAMA CITY, FLORIDA 32407-7015 IN REPLY REFER TO: NAVSEA TA94-010 NAVY EXPERIMENTAL DIVING UNIT TECHNICAL REPORT NO. 6-94 COMMERCIALLY AVAILABLE PERFORMANCE INC. REGULATORS ENC(DV/SW) J. A. NOE APRIL 1994 DISTRIBUTION STATEMENT A: Approved for public ielease; distribution is unlimited. Su itted: Reviewed: Approved: J. A. NOE BERT MARSH ENC(DV/SW), USN CDR, MC, USN CDR, USN Task Leader Senior Medical Officer Commanding Officer 0 D. McKINLEY - LCDR, USN Senior Projects Officer J. R. CLARKE, Ph. D. Scientific Director 94-13939 M. V. LINDSTROM LCDR, USN Executive Officer 94 5 09 0"3

UNCLASSIFIED SECURITY CLASSIFICATION OF THIS PAGE REPORT DOCUMENTATION PAGE la. REPORT SECURITY CLASSIFICATION Unclassified lb. RESTRICTIVE MARKINGS 2a. SECURITY CLASSIFICATION AUTHORITY 3. DISTRIBUTION/AVAILABILITY OF REPORT DISTRIBUTION STATEMENT A: Approved for public release; 2b. DECLASSIFICATION/DOWNGRADING AUTHORITY distribution is unlimited 4. PERFORMING ORGANIZATION REPORT NUMBER(S) 5. MONITORING ORGANIZATION REPORT NUMBER(S) NEDU Report No. 6-94 6a. NAME OF PERFORMING 6b. OFFICE SYMBOL 7a. NAME OF MONITORING ORGANIZATION ORGANIZ. (If Applicable) Navy Experimental Diving 03E1 Unit 6c. ADDRESS (City, State, and ZIP Code) 7b. ADDRESS (City, State, and Zip Code) 321 Bullfinch Road, Panama City, FL 32407-7015 8a. NAME OF FUNDING SPONSORING 8b. OFF-CE SYMBOL 9. PROCUREMENT INSTRUMENT IDENTIFICATION NUMBER ORGANIZATION (If Applicable) Naval Sea Systems Command OOC 8c. ADDRESS (City, State, and ZIP Code) 10. SOURCE OF FUNDING NUMBERS 2531 Jefferson Davis Highway, Arlington, VA 22242-5160 PROGRAM PROJECT NO. TASK NO. WORK UNIT ELEMENT NO. 94-010 ACCESSION NO. 11. TITLE (Include Security Classification) (U) Commercially Available Performance Inc. Regulators 12. PERSONAL AUTHOR(S) ENC(DV/SW) J. A. Noe 13a. TYPE OF REPORT 13b. TIME COVERED 14. DATE OF REPORT (Year, Month, Day) 15. PAGE COUNT Test Report I FROM JAN 94 TO APR 94 APRIL 1994 15 16. SUPPLEMENTARY NOTATION 17. COSATI CODES 18. SUBJECT TERMS (Continue on reverse if necessary and identify by block number) FIELD GROUP SUB-GROUP Open-Circuit SCUBA Regulators, Cold Water Open-Circuit SCUBA Regulators, Authorized for Navy Use (ANU) list, Work of Breathing (WOB), Respiratory Minute Volume (RMV), Performance Goal Standard 19. ABSTRACT (Continue on reverse if necessary and identify by block number) Evaluations were conducted on Performance Inc, Chapel Hilt, NC, PDXL 700 and PDXL 1000 regulators, to determine which commercially available open-circuit SCUBA regulators were capable of meeting performance goat standards for Navy use. Bench testing of all candidate regulators was conducted to establish flow patterns and air delivery capacity. Unmanned testing using a breathing simulator at ventilation rates of 22.5, 40, 62.5, 75, and 90 L/min at test depths of 0 to 60 msw (0 to 198 fsw), in 10 msw (33 fsw) increments was conducted to determine work of breathing (WOB) values. Each candidate regulator model was subjected to five runs each and a mean of the WOB was established. This mean WOB value was then compared to the Performance Goat Standard of 1.37 Joules per Liter (J/L) at 60 msw (198 fsw). Testing was conducted in ambient temperature water, approximately 21'C (70 0 F), with a supply pressure of 10.34 MPa (1500 psi). All testing conducted determined that none of the candidate test regulators were capable of meeting the requirements for acceptance by the US Navy. 20. DISTRIBUTION/AVAILABILITY OF ABSTRACT 21. ABSTRACT SECURITY CLASSIFICATION UNCLASSIFIED/UNLIMITED Xt SAME AS RPT. I i DTIC USERS Unclassified 22a. NAME OF RESPONSIBLE INDIVIDUAL 22b. TELEPHONE (Include Area Code) 22c. OFFICE SYMBOL DO Form 1473 NEDU Litbrw ian 904-230-3100 UNCLASSIFIED SECURITY CLASSIFICATION OF THIS PAGE

GLOSSARY ANU fsw J/L Authorized for Navy Use List (NAVSEAINST 10560.2 series) Feet of Seawater Joules per liter, unit of measure for "Work of Breathing" normalized for tidal volume kpa Kilopascals, newtons/meter 2 MPa msw NAVSEA NEDU OSF psi RMV SCFM SLM WOB Megapascal Meters of Sea Water Naval Sea Systems Command Navy Experimental Diving Unit Ocean Simulation Facility Pounds per Square Inch Respiratory Minute Volume Standard Cubic Feet per Minute Standard Liters per Minute Work of breathing, a computer derived estimate of total respiratory effort obtained when breathing a regulator with a mechanical breathing simulator. Accesion For NTIS CRA&I DTIC TAB Unannounced Justification... By... Dist ibution I Dist A0 Availability Codes Avail and I or Special

CONTENTS Page No. INTRODUCTION... 1 UNMANNED EVALUATION M ETH O DS... 1 RESU LTS... 2 MANNED EVALUATION... 3 CONCLUSIONS/RECOMMENDATIONS... 3 REFERENCES... 4 iii

ILLUSTRATIONS Figure No. Page No. 1 PDXL 700 Flow Characteristics... 7 2 PDXL 1000 Flow Characteristics... 8 3 Comparison of PDXL 700 Performance to Performance Goal Standard at 10.34 MPa (1500 psi) Supply Pressure... 9 4 Comparison of PDXL 1000 Performance to Performance Goal Standard at 10.34 MPA (1500 psi) Supply Pressure... 10 Table No. Page No. 1 Unmanned PDXL 700 Open Circuit SCUBA Regulator Work of Breathing Results... 5 2 Unmanned PDXL 1000 Open Circuit SCUBA Regulator Work of Breathing Results... 6 iv

INTRODUCTION The requirement for an open circuit SCUBA regulator with the ability to perform within the Performance Goal Standard 1 to a depth of 60 msw (198 fsw) has evolved from changes in diver mission profiles and concern for diver safety in the FLEET DIVER community. To achieve this end, NEDU was tasked 2 to test and evaluate production models of commercially available open circuit SCUBA regulators to determine which ones meet the US Navy's demanding performance criteria. PERFORMANCE INC., Chapel Hill, N.C., provided two candidate models for evaluation, the PDXL 700 and the PDXL 1000. METHODS UNMANNED EVALUATION Unmanned evaluations of the two candidate regulator models measured Work of Breathing (WOB) levels and compared them to Performance Goal Standards 1, which represent ideal performance levels for open circuit SCUBA regulators. WOB levels are a computer derived estimate of total respiratory effort obtained when breathing a regulator with a mechanical breathing simulator, with units of joules per liter (J/L). Five different regulators were tested for each model. WOB averages represented the mean of the five test results. The performance goal' of 1.37 J/L at 40 msw (132 fsw) with a respiratory minute ventilation (RMV) of 62.5 liters per minute (L/min) and first stage supply pressure of 10.34 MPa (1 500 psi) was extended to include 50 and 60 msw (1 65 and 198 fsw). Testing was also conducted at the deeper depths, at high ventilatory rates, and reduced first stage supply pressure to characterize the performance of the regulators beyond the current performance standards. These extended tests were not part of the acceptance criteria. A hierarchical series of standardized testing 3 was conducted on each candidate regulator. Dry bench testing was first conducted to determine if the candidate regulators met the manufacturer's specifications for air delivery. Inhalation pressures were recorded at 141 SLM ± 1 SLM (5 SCFM) increments from 0 to 849 SLM ( 0 to 30 SCFM) of flow. A mean of the inhalation pressure (± 1 standard deviation) was derived from five test regulators per candidate model. Bench testing was terminated if cracking pressure varied from manufacturer's specifications by ± 0.13 kpa (0.50 inches of water). 1

A mechanical breathing simulator (Reimers Consultants, Falls Church, VA) provided sinusoidal breathing loops with RMV's ranging from 40 to 90 L/min, thus emulating varied diver work rates. Supply pressure to the first stage was maintained at 10.34 MPa (1500 psi) for the downward excursion, then reduced to 3.44 MPa (500 psi) to simulate worst case, for the upward excursion. Work of Breathing loops were taken at 10 msw (33 fsw) increments in both conditions. Test depths ranged from 0 to 60 msw (0 to 198 fsw). Water temperature was maintained at ambient, approximately 21 C (70'F). Testing at a specific RMV/depth parameter was terminated if inhalation or exhalation pressure exceeded 4 kpa, the working limits of the pressure transducers currently used in the Experimental Diving Facility. Additionally, if two regulators of one model exceeded 4 kpa within the Performance Goal Standard RMV/depth parameter, testing of that model was terminated. Descriptive statistics were used to obtain the mean and standard deviation of the data. To determine acceptability of WOB values that were slightly higher than Performance Goal Standard, a one sample T-test with significance established at P < 0.05 was performed. RESULTS Dry bench testing of candidate regulators revealed that the PDXL 700 delivered an average of 707 SLM (25 SCFM) at a high average inhalation pressure of 1.10 kpa (4.3 inches of water). Additionally, only one of the candidate regulators of this model was capable of delivering 849 SLM (30 SCFM). The PDXL 1000 was capable of delivering an average of 707 SLM (25 SCFM) at an average inhalation pressure of 1.02 kpa (4 inches of water). Additionally, only two of this model's candidate regulators was capable of delivering 849 SLM (30 SCFM). Flow characteristics for the PDXL 700 are shown in Figure 1. Figure 2 shows the flow characteristics for the PDXL 1000. WOB values for the PDXL 700 at 10.34 MPa (1500 psi) supply pressure are summarized in Table 1 and Figure 3. At 40 RMV, WOB values exceed Performance Goal Standard at 10 msw (33 fsw), and continue to increase with each incremental increase in test depth, to a maximum attainable test depth of 40 msw (132 fsw). At 62.5 and 75 RMV, WOB values are beyond Performance Goal Standard at 0 msw, and increase markedly to maximum attainable test depths of 30 and 20 msw (99 and 66 fsw) respectively. WOB values were unattainable at the extreme ventilatory rate of 90 L/min. Due to the extremely high WOB values attained with two candidate regulators at the 10.34 MPa (1500 psi) supply pressure, any further testing of this model was terminated. 2

Table 2 and Figure 4 summarizes WOB values for the PDXL 1000 at 10.34 MPa (1500 psi) supply pressure. Performance Goal Standard was exceeded at 40 RMV and above from 0 to 60 msw (0 to 198 fsw). At 62.5 RMV, termination criteria was met at 30 msw (99 fsw). For the higher ventilatory rates of 75 and 90 L/min, termination criteria was met at 20 msw (66 fsw). Due to the extremely high WOB values attained with two candidate regulators at the 10.34 MPa,1500 psi) supply pressure, any further testing of this model was terminated. MANNED EVALUATION Due to the extremely poor performance evidenced during the unmanned testing phase, no manned testing was conducted for either candidate model regulator. CONCLUSIONS/RECOMMENDATIONS It is important to note that the establishment of performance criteria to 60 msw (198 fsw) is solely a Navy requirement and is not an endorsement by NEDU that casual/standard SCUBA dives be conducted to such depths with these regulators. Additionally, performance goals are not acceptance criteria for diving equipment approval and diving equipment that exceed these goals are not necessarily unsafe for diver use. Work of Breathing results obtained from the PDXL 700 clearly identify this as a sub-standard performing regulator, not capable of meeting Performance Goal Standard at any depth or ventilatory rate. Based on the results obtained during unmanned evaluations of the PDXL 700, NEDU recommends that this regulator be excluded from the ANU list. Work of Breathing results obtained from the PDXL 1000 show that this regulator also is not capable of meeting the performance criteria of the US Navy. Based on the results obtained during the unmanned evaluations of the PDXL 1000, NEDU recommends that this regulator be excluded from the ANU List. 3

REFERENCES 1. J. R. Middleton and E. D. Thalmann, Standardized NEDU Unmanned UBA Test Procedures and Performance Goals, NEDU TR 3-81, Navy Experimental Diving Unit, July 1981. 2. NAVSEA Task 94-010, Commercial Diving Equipment Test and Evaluation, January, 1994. 3. Evaluation of Commercial Open Circuit SCUBA Regulators (Unmanned/Manned), NEDU Test Plan 93-21 (Limited Distribution), Navy Experimental Diving Unit, May 1993. 4. Evaluation of Commercial SCUBA Regulators OSF Bounce Dive Series to 190 FSW (Manned), NEDU Test Plan 92-44 (Limited Distribution), Navy Experimental Diving Unit, November 1992. 4

TABLE 1 PDXL 700 OPEN CIRCUIT SCUBA REGULATOR WOB RESULTS MEAN ± 1 STANDARD DEVIATION EXPRESSED IN JOULES PER LITER (J/L) 10.34 MPa (1500 PSI) SUPPLY PRESSURE DEPTH IN RESPIRATORY MINUTE VOLUME METERS 40 62.5 75 90 0 1.28 ± 0.14 1.72 ± 0.19 1.98 0.21 # 10 1.66 ± 0.23 -_.28 ± 0.27 2.81 + 0.26 # 20 1.90 ± 0.20 3.03 ± 0.20 3.96 + 0.27 # 30 2.19 ± 0.23 3.93 ± 0.31 # i 40 2.51 ± 0.23 # # # 50 # # # # 60 # # # # # Denotes WOB value beyond termination criteria 5

TABLE 2 PDXL 1000 OPEN CIRCUIT SCUBA REGULATOR WOB RESULTS MEAN ± 1 STANDARD DEVIATION EXPRESSED IN JOULES PER LITER (J/L) 10.34 MPa (1500 PSI) SUPPLY PRESSURE DEPTH IN RESPIRATORY MINUTE VOLUME METERS 40 62.5 75 90 0 1.42 0.08 1.90 ± 0.97 2.18 ±-O-.10 2.57 ± 0.05 ----- 1-0 1.96 0.14 2.68 ±--0.07-3.24 ±-0-.11-3.93m 0.10 20 2.19 0.14 3.35 ±-0.07------ 4.20-± 0.21 # 30 2.51 o.14 4.14 ± 0.24 # # 40 2.81 0.19 # # # 50 3.12 0.14 # # # 60 3.48 0.21 # # # # Denotes WOB value beyond termination criteria

1.4 S1.2 w c 1.0 Co) w 0.8 z 0.6 0 < 0.4 "1- r z 0.2 0 141 283 424 566 707 849 FLOW RATE (SLM) Figure 1. PDXL 700 Flow Characteristics 7

1.4 (L 1.2 wlu n" 1.0 C/) w 0.8 cc n" z 0.6 0 7-0.4- z 0.2 0.0., 0 141 283 424 566 707 849 FLOW RATE (SLM) Figure 2. PDXL 1000 Flow Characteristics 8

4.00/ 3.75 --- 40 RMV 3.50 -f 62.5 RMV 3.25-75 RMV "3.00 (.9 z 2.75-2.50-.<. 2.25" 2.00-1.75 PERFORMANCE GOAL o 1.50" STANDARD ýe 1.25- O 1.00- S~0."75-0.50 0.25 0.00-,,,,,, 0 10 20 30 40 50 60 DEPTH IN METERS Figure 3. PDXL 700, 10.34 MPa (1500 psi) Supply Pressure 9

4.00 3.75-3.50 3.25-3.00- z 2.75- I 2.50 40 RMV 2.25-62.5 RMV w 75 RMV cc 2.00 1.75 PERFORMANCEGOAL 90 RMV 1.50 -STANDARD o ve 1.25 - o 1.00-0.75-0.50 0.25 0.00,,,,, 0 10 20 30 40 50 60 DEPTH IN METERS Figure 4. PDXL 1000, 10.34 MPa (1500 psi) Supply Pressure 10