Finex Airspray Package Sprayer

Similar documents
OPERATION / 3Z9305G 1:1 RATIO TRITON / Spray Packages / / / List of Models, page 2 / / / 100 psi (7 bar, 0.7 MPa) Maximum Working Pressure

OPERATION. Zinc Sprayer. For Maximum Working Pressure see page 2. Rev. E

2-Liter Pressure Cup. Instructions - Parts List C

INSTRUCTIONS PARTS LIST

2-Quart (1.9 Liter) Pressure Cup

For use with all Graco/Gusmer spray guns (not included). 3 Gallon Solvent Tank

Back Pressure Regulator

INSTRUCTIONS PARTS LIST U.S. PAT: 6,874,404; 6,516,707; 6,223,645

Color/Catalyst Dispense Valves

Fire-Ball 300 and 425 Grease Pumps

BACK PRESSURE VALVE. Instructions Parts List J

SSFU SUPER SPRAYFAST UNIVERSAL ADHESIVE APPLICATOR

Huskyt/ Twistorkt Package

Feed and Solvent Flush Kits

Dyna-Star HP Pump System

Heavy Fluid Air Spray Gun

15:1 Ratio Fire-Ball Undercoater Pumps

Pistol-Grip Mastic Flo-Gun

Fluid Regulators. Instructions/Parts List C. High Pressure II 2 G. Read warnings and instructions. See page 3 for model information.

Husky 307 Air Spray/HVLP Systems

Instructions Parts List

50:1 Fire Ball 300 Pump Module

Ball Valves, Check Valves, and Swivels

Hotmelt/Warm Melt Heated Hose

Instructions Parts List. Contents E. HIGH VOLUME Air Control Kits. 250 psi (1.7 MPa, 17.2 bar) Maximum Air Inlet Pressure

INSTRUCTIONS-PARTS LIST

3600 psi (25.0 MPa, 250 bar) Maximum Fluid Working Pressure

M2K Mix Manifolds. Instructions - Parts B EN. Part 17D763 - M2K manifold Part 24W861 - Remote M2K manifold

Instructions Parts List

INSTRUCTIONS PARTS LIST

Electric Airless Sprayer

APS-100 Primer Spray Module

INSTRUCTIONS PARTS LIST

LD Series Enclosed Hose Reels

RS Gun Universal Adapter Kit

Instructions Parts List

INSTRUCTIONS-PARTS LIST

Instructions Parts List. Table of Contents H. AIR OPERATED Valve Assembly

Husky 1050A, CSA-Certified Diaphragm Pumps

Instructions Parts List

Fluid Regulators. Instructions -Parts List. Table of Contents Z EN HIGH PRESSURE

Air Consumption Recommended Usage Siphon Feed

Instructions Parts List

INSTRUCTIONS-PARTS LIST

Instructions Parts List

Operation and Parts 3A5616A EN ADJUSTABLE FLOW CAP KIT

Instructions Parts List

G700N Air Spray Package

T1-Titanium HVLP Siphon Feed Spray Gun

1:1 Extruder. Operation H EN. Table Of Contents. Part No Part No

HVLP EDGE Gun G EN

Instructions Parts List

Instructions Parts List

Instructions Parts List

INSTRUCTIONS-PARTS LIST

WARNING: HIGH PRESSURE.

INSTRUCTIONS PARTS LIST

Instructions Parts List

President 10:1 Ratio Powerflo System

Instructions Parts List

Instructions-Parts List

Fluid Pressure Regulators

GlasCraft Catalyst Pump

Wall Mount Airless Packages

Instructions Parts List

INSTRUCTIONS PARTS LIST

Instructions Parts List

Series 700 Hose Reels

President 10:1 Ratio Air Spray System

High Speed Spindl-Gard Lubrication System with Electric Pump

Cart Mounted Air Assisted Package

Cart-Mounted Airless Package

Instructions Truck Mounted Bare Hose Reel for Grease

INSTRUCTIONS-PARTS LIST

T2 2:1 Ratio Transfer Pump

T1-Titanium HVLP Pressure Feed Spray Gun

Cart-Mounted Zinc Spray Package

Cart-Mounted Airless Package

Operation. Diaphragm Pump 3A2578D. Maximum Working Pressure: 125 psi (0.86 MPa, 8.6 bar) Read all warnings and instructions in this manual and in your

Cart Mounted, Heated Air Assisted Package

Operation. Interior Texture Sprayer TX B. For Water-Based Materials Only

Husky Air-Operated Diaphragm Pump

Volumetric Fluid Flow Meter High Pressure Meters 4000 psi (28 MPa, 276 bar) Maximum Working Fluid Pressure

INSTRUCTIONS PARTS LIST This manual contains important warnings and information. READ AND RETAIN FOR REFERENCE

Therm-O-Flow Plus For all Drum Unloaders

Instructions Parts List

HVLP Compressor/Cart INSTRUCTIONS PARTS LIST. Related Manuals. GTS-ProCart. 240V AC 50/60 Hz

Instructions Parts List

Husky 2200 Air-Operated Diaphragm Pump

Instructions-Parts List

AA200hs Air-Assisted Airless Spray Package

Instructions Parts List

Operation 3A1169B EN. Interior Texture Sprayer TS F psi (.41 MPa, 4.1 bar) Maximum Fluid Working Pressure

7500 PSI Airless Spray Gun

INSTRUCTIONS-PARTS LIST

Hydra-Cat Proportioners

Series 350 Hose Reels

3500 PSI Airless Spray Gun

Cart-Mounted Airless Package

Series 500 Hose Reels

Transcription:

Instructions - Parts Finex Airspray Package Sprayer 312473B ENG Package solutions for pumping and spraying finishing materials. For professional use only. Important Safety Instructions Read all warnings and instructions in this manual and in your respective pump manual. Save these instructions. Models: 289353 with Finex Airspray Gun 100 psi (7 bar, 0.7 MPa) Maximum Working Pressure 289354 with Finex HVLP Gun 100 psi (7 bar, 0.7 MPa) Maximum Working Pressure TI10823A

Related Manuals Contents Related Manuals........................... 2 Warnings................................. 3 Installation................................ 5 Grounding.............................. 5 Flush Before Using Equipment.............. 5 Components............................... 6 Sprayer Components..................... 6 Required Components (not included)......... 6 Recommended Components............... 6 Pump Operation and Repair.................. 6 Pressure Relief............................ 6 Typical Installation......................... 7 Setup/Installation........................... 8 Grounding................................ 9 Flush..................................... 9 Prime.................................... 10 Spraying................................. 11 Shutdown................................ 11 Maintenance.............................. 12 Troubleshooting........................... 13 Parts.................................... 14 Finex Sprayer Package................... 14 Dimensions............................... 15 Technical Data............................ 15 Graco Standard Warranty................... 16 Graco Information......................... 16 Related Manuals Manual Description 308553 Husky 307 Air-Operated Diaphragm Pumps 312388 Finex Gun 308325 Fluid Pressure Regulators 2 312473B

Warnings Warnings The following warnings are for the setup, use, grounding, maintenance, and repair of this equipment. The exclamation point symbol alerts you to a general warning and the hazard symbol refers to procedure-specific risk. Refer back to these warnings. Additional, product-specific warnings may be found throughout the body of this manual where applicable. WARNING FIRE AND EXPLOSION HAZARD Flammable fumes, such as solvent and paint fumes, in work area can ignite or explode. To help prevent fire and explosion: Use equipment only in well ventilated area. Eliminate all ignition sources; such as pilot lights, cigarettes, portable electric lamps, and plastic drop cloths (potential static arc). Keep work area free of debris, including solvent, rags and gasoline. Do not plug or unplug power cords, or turn power or light switches on or off when flammable fumes are present. Ground all equipment in the work area. See Grounding instructions. Use only grounded hoses. Hold gun firmly to side of grounded pail when triggering into pail. If there is static sparking or you feel a shock, stop operation immediately. Do not use equipment until you identify and correct the problem. Keep a working fire extinguisher in the work area. EQUIPMENT MISUSE HAZARD Misuse can cause death or serious injury. Do not operate the unit when fatigued or under the influence of drugs or alcohol. Do not exceed the maximum working pressure or temperature rating of the lowest rated system component. See Technical Data in all equipment manuals. Use fluids and solvents that are compatible with equipment wetted parts. See Technical Data in all equipment manuals. Read fluid and solvent manufacturer s warnings. For complete information about your material, request MSDS forms from distributor or retailer. Check equipment daily. Repair or replace worn or damaged parts immediately with genuine manufacturer s replacement parts only. Do not alter or modify equipment. Use equipment only for its intended purpose. Call your distributor for information. Route hoses and cables away from traffic areas, sharp edges, moving parts, and hot surfaces. Do not kink or over bend hoses or use hoses to pull equipment. Keep children and animals away from work area. Comply with all applicable safety regulations. PRESSURIZED EQUIPMENT HAZARD Fluid from the gun/dispense valve, leaks, or ruptured components can splash in the eyes or on skin and cause serious injury. Follow Pressure Relief Procedure in this manual, when you stop spraying and before cleaning, checking, or servicing equipment. Tighten all fluid connections before operating the equipment. Check hoses, tubes, and couplings daily. Replace worn or damaged parts immediately. 312473B 3

Warnings WARNING TOXIC FLUID OR FUMES HAZARD Toxic fluids or fumes can cause serious injury or death if splashed in the eyes or on skin, inhaled, or swallowed. Read MSDS s to know the specific hazards of the fluids you are using. Store hazardous fluid in approved containers, and dispose of it according to applicable guidelines. Always wear impervious gloves when spraying or cleaning equipment. PERSONAL PROTECTIVE EQUIPMENT You must wear appropriate protective equipment when operating, servicing, or when in the operating area of the equipment to help protect you from serious injury, including eye injury, inhalation of toxic fumes, burns, and hearing loss. This equipment includes but is not limited to: Protective eyewear Clothing and respirator as recommended by the fluid and solvent manufacturer Gloves Hearing protection PRESSURIZED ALUMINUM PARTS HAZARD Do not use 1,1,1-trichloroethane, methylene chloride, other halogenated hydrocarbon solvents or fluids containing such solvents in pressurized aluminum equipment. Such use can cause serious chemical reaction and equipment rupture, and result in death, serious injury, and property damage. 4 312473B

Installation Installation Grounding The equipment must be grounded. Grounding reduces the risk of static and electric shock by providing an escape wire for the electrical current due to static build up or in the event of a short circuit. Pump: use the ground wire and clamp (supplied). See FIG. 1. Use the ground screw (GS) and lock washer (LW) to attach the ground wire (N) at the rear of the air motor. Tighten the screw securely. Connect the other end of the ground wire to a true earth ground (P). To maintain grounding continuity when flushing or relieving pressure: hold metal part of the spray gun/dispense valve firmly to the side of a grounded metal pail, then trigger the gun/valve. Flush Before Using Equipment The equipment was tested with water. To avoid contaminating your fluid with water, flush the equipment with a compatible solvent before using the equipment. See your pump manual. See Related Manuals, page 2. N P GS, LW FIG. 1. Ground Wire TI10824A Air and fluid hoses: use only electrically conductive hoses. Air compressor: follow manufacturer s recommendations. Spray gun / Dispense valve: ground through connection to a properly grounded air or fluid hose and pump. Air hose is conductive and used to ground gun. If adding lengths to hose be sure to use conductive hoses. Fluid supply container: follow local code. Object being sprayed: follow local code. Solvent pails used when flushing: follow local code. Use only conductive metal pails, placed on a grounded surface. Do not place the pail on a nonconductive surface, such as paper or cardboard, which interrupts grounding continuity. 312473B 5

Controls and Components Controls and Components Pump Operation and Repair Trapped air can cause the pump to cycle unexpectedly, which could result in serious injury from splashing or moving parts. Sprayer Controls Pump air pressure regulator (C): a locking regulator to adjust air pressure to the motor and fluid outlet pressure of pump. View the air pressure gauge to read air pressure. Gun air pressure regulator (D): a locking regulator to adjust air pressure to the gun. View the air pressure gauge to read air pressure. Fluid pressure regulator (E): used to adjust the fluid pressure to the spray gun. Follow the Pressure Relief Procedure in your pump manual before cleaning or repairing your equipment. For complete instructions and warnings see your respective pump manual. See Related Manuals, page 2. Bleed-type master air valve (L): required in your system to relieve air trapped between it and the air motor when the valve is closed. Required Components (not included) Main Air Supply (J): connects air supply from air compressor to pump. Recommended Components Air line filter (F): removes harmful contaminants from entering the air control module and air motor. Air line moisture drain valve (M): installed at the bottom of each air line drop, to drain moisture. 6 312473B

Typical Installation Typical Installation B True Earth Ground M A E I F J F H C K D L G TI10825A FIG. 2: Typical Installation (Finex Airspray Gun Shown) Key: A Pump B Bleed-type Master Air Line Shutoff Valve C Pump Air Pressure Regulator D Gun Air Pressure Regulator E Gun Fluid Pressure Regulator F Air Filter G H I J K L M Hose Set Suction Hose Pump Ground Wire (required) Main Air Supply Line Spray Gun, Finex Airspray or HVLP Bleed Type Master Air Valve Air Line Moisture Drain 312473B 7

Pressure Relief Pressure Relief 3. Connect the gun fluid hose to fluid regulator. Tighten securely. Follow pressure relief procedure when you stop spraying and before cleaning, checking, or servicing the equipment. 1. Shut off the bleed-type air valve. TI10829A 4. Connect the fluid hose to the gun. Tighten securely. 2. Hold the gun firmly against a grounded metal pail and trigger the gun. - TI10826A TI10831A 5. Ground the pump. See Grounding, page 9. Setup/Installation TI10828A TI10824A 6. Connect the main air supply to the bleed-type air valve. Before using the equipment for the first time, follow this procedure. 1. Connect the air hose to the gun air regulator. 7. Flush. See Flush, page 9. TI10829A FLUSH TI10835A WASTE TI10828A TI10829A 8. Prime. See Prime, page 10. 2. Connect the air hose to the gun. PAINT TI10832A WASTE TI10828A TI10830A 9. Spray. See Spraying, page 11. TI10833A 8 312473B

Grounding Grounding 4. Turn off both air regulators. - - Read Fire and Explosion Hazard. See page 3. 5. Open the bleed-type air valve. TI10836A 1. Connect the ground wire clamp to a true earth ground. + TI10827A 6. Open the pump air regulator until the pump starts. TI10824A + 2. Ground the object being sprayed, fluid supply container, and all other equipment in the spray area. TI10836A 7. When clean solvent flows without air from the gun stop spraying. TI10832A TI10832A 3. Ground all solvent pails. Use only metal pails. Do not place on a non-conductive surface such as paper or cardboard. TI10870A 8. Remove the suction tube from the solvent. Continue to spray until all solvent is out of the gun. TI10835A TI10835A TI10870A Flush 9. Close the bleed type air valve. 1. Relieve pressure. See Typical Installation, page 7. 2. Remove the air cap. Clean separately. - TI10826A 10. Relieve pressure. See Typical Installation, page 7. TI10834A 3. Place the suction tube in solvent. TI10835A 312473B 9

Prime Prime 1. Shut off both air regulators and the bleed-type air valve. 7. Adjust the fluid pressure regulator. + TI10837A - - TI10836A - TI10826A 8. Hold the gun firmly against a grounded metal pail and trigger the gun until fluid flow is steady. Release the trigger. The equipment is ready to spray. 2. Shut off the fluid regulator. - TI10828A TI10837A 3. Install the air cap. TI10834A 4. Place the suction tube in the fluid. TI10832A 5. Open the bleed-type air valve. + TI10827A 6. Open the pump air regulator until the pump starts. + TI10836A 10 312473B

+ Spraying Spraying 1. Adjust fluid flow using the pump air regulator or the fluid pressure regulator. + Shutdown 1. Flush. See Flush page 9. 2. Relieve pressure. See Typical Installation, page 7. TI10836A TI10837A 2. Adjust fluid pressure so stream from gun travels 6 8 in. straight before falling off. 6 in. to 8 in. (152 mm to 203 mm) TI10838A 3. Adjust the gun air regulator to achieve proper spray gun atomization. TI10836A + 4. Test the spray pattern. Read the fluid manufacturer s recommendations. Adjust as necessary. TI10839A TI10833A 312473B 11

Maintenance Maintenance 6. Clean the accessory air filter (not supplied) in your main air line. Relieve pressure before servicing. See Typical Installation, page 7. TI10871A 1. Flush. See Flush, page 9. 2. Clean the air cap and fluid nozzle. TI10834A TI10840A 3. Clean the suction tube and inlet strainer, using a compatible solvent. TI10841A TI10842A 4. Clean the outside of the sprayer, using a soft cloth and compatible solvent. TI10823A 5. Check the hoses, tubes, and couplings every day. Tighten all fluid connections before each use. TI10830A TI10829A 12 312473B

Troubleshooting Troubleshooting Relieve pressure before servicing. See Typical Installation, page 8. Problem Cause Solution Pump will not run, or stops. Air line valve shut off. Open valve. Clogged fluid line or spray gun. Clear, service. Do not allow fluid to setup in the pump and lines. Stuck or damaged pump air valve. Service pump. Use filtered air. Pump runs erratically. Clogged suction line or inlet strainer. Clear. Pump runs too fast. Exhausted fluid supply. Refill fluid supply and prime sprayer. Pump cycles at stall or fails to hold Worn check valves or o-rings. Service pump. pressure at stall. Audible air leak. Worn air valve. Service pump. Air bubbles in fluid. Loose suction line. Tighten. Use a compatible liquid thread sealant or PTFE tape on connections. Ruptured diaphragm. Service pump. Poor finish or irregular pattern. Incorrect fluid or air pressure at gun. See gun manual; read fluid manufacturer s recommendations. Use fluid regulator. Fluid is too thick or too thin. Thin or thicken fluid; read fluid manufacturer s recommendations. Dirty, worn, or damaged spray gun. Service gun. Fluid is settling out. Order Part No. 245081 Agitator Kit. 312473B 13

Parts Parts 289353 with Finex Airspray Gun 289354 with Finex HVLP Gun 11 3 6 2 21 8 9 12 19 17 10 23 16 22a, 22b 18 25 24 7 1 15 13 5 4 TI10872A Ref. Part Description Qty. 1 289609 PLATE, mounting 1 2 D31331 PUMP, diaphragm 1 3 164856 FITTING, nipple, reducing 2 4 15D921 LEG, right, (finished) 1 5 15D922 LEG, left, (finished) 1 6 241976 REGULATOR, press, fluid 1 7 162453 FITTING, 1/4 NPSM X 1/4 NPT 1 8 116513 REGULATOR, air 2 9 110436 GAUGE, pressure air 2 10 115219 FITTING, tee, 1/4 NPT 1 11 289610 HANDLE, wire pump 1 12 15R472 FASTENER, hex HD, flanged 1/4-2 4 13 114104 SCREW, mach, hex wash HD 4 15 289608 STRAINER, suction line 1 16 111864 CONNECTOR, male 2 Ref. Part Description Qty. 17 590570 HOSE, polyethylene 4ft 18 116473 VALVE, vented 2 way 1 19 237686 WIRE, ground assembly w/clamp 1 20 289522 HOSE, set, bundled (not shown) 25ft (289353) 240421 HOSE, set, bundled (not shown) 25ft (289354) 21 608780 FITTING, elbow male 2 22a 289254 GUN, GRACO Finex, conv, press 1 22b 289249 GUN, GRACO Finex HVLP 1 23 115942 NUT, lock hex 8 24 104641 FITTING, bulkhead 1 25 111763 FITTING, elbow 1/4 NPT 1 26 513066 TUBE, 3/8 OD Nylon (not shown) 1ft 14 312473B

Dimensions Dimensions 19.19 in. (48.74 cm.) TI10874A 19.26 in. (48.92 cm.) 12.02 in. (30.53 cm.) TI10873A Technical Data Maximum fluid working pressure............. 100 psi (0.7 MPa, 7 bar) Maximum incoming air pressure............. 100 psi (0.7 MPa, 7 bar) Operating temperature range............... 40-109 F (4.4-43 C) Package Weight.......................... 19.8 lbs (9.0 kg) Wetted Parts Pump..................... see related manuals, page 2. Gun....................... see related manuals, page 2. Fluid Regulator............. see related manuals, page 2. Other...................... nylon, acetal, SST, polyethylene Sound levels: Refer to related pump and gun manuals. See page 2. 312473B 15

Graco Standard Warranty Graco warrants all equipment referenced in this document which is manufactured by Graco and bearing its name to be free from defects in material and workmanship on the date of sale to the original purchaser for use. With the exception of any special, extended, or limited warranty published by Graco, Graco will, for a period of twelve months from the date of sale, repair or replace any part of the equipment determined by Graco to be defective. This warranty applies only when the equipment is installed, operated and maintained in accordance with Graco s written recommendations. This warranty does not cover, and Graco shall not be liable for general wear and tear, or any malfunction, damage or wear caused by faulty installation, misapplication, abrasion, corrosion, inadequate or improper maintenance, negligence, accident, tampering, or substitution of non-graco component parts. Nor shall Graco be liable for malfunction, damage or wear caused by the incompatibility of Graco equipment with structures, accessories, equipment or materials not supplied by Graco, or the improper design, manufacture, installation, operation or maintenance of structures, accessories, equipment or materials not supplied by Graco. This warranty is conditioned upon the prepaid return of the equipment claimed to be defective to an authorized Graco distributor for verification of the claimed defect. If the claimed defect is verified, Graco will repair or replace free of charge any defective parts. The equipment will be returned to the original purchaser transportation prepaid. If inspection of the equipment does not disclose any defect in material or workmanship, repairs will be made at a reasonable charge, which charges may include the costs of parts, labor, and transportation. THIS WARRANTY IS EXCLUSIVE, AND IS IN LIEU OF ANY OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING BUT NOT LIMITED TO WARRANTY OF MERCHANTABILITY OR WARRANTY OF FITNESS FOR A PARTICULAR PURPOSE. Graco s sole obligation and buyer s sole remedy for any breach of warranty shall be as set forth above. The buyer agrees that no other remedy (including, but not limited to, incidental or consequential damages for lost profits, lost sales, injury to person or property, or any other incidental or consequential loss) shall be available. Any action for breach of warranty must be brought within two (2) years of the date of sale. GRACO MAKES NO WARRANTY, AND DISCLAIMS ALL IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE, IN CONNECTION WITH ACCESSORIES, EQUIPMENT, MATERIALS OR COMPONENTS SOLD BUT NOT MANUFACTURED BY GRACO. These items sold, but not manufactured by Graco (such as electric motors, switches, hose, etc.), are subject to the warranty, if any, of their manufacturer. Graco will provide purchaser with reasonable assistance in making any claim for breach of these warranties. In no event will Graco be liable for indirect, incidental, special or consequential damages resulting from Graco supplying equipment hereunder, or the furnishing, performance, or use of any products or other goods sold hereto, whether due to a breach of contract, breach of warranty, the negligence of Graco, or otherwise. FOR GRACO CANADA CUSTOMERS The Parties acknowledge that they have required that the present document, as well as all documents, notices and legal proceedings entered into, given or instituted pursuant hereto or relating directly or indirectly hereto, be drawn up in English. Les parties reconnaissent avoir convenu que la rédaction du présente document sera en Anglais, ainsi que tous documents, avis et procédures judiciaires exécutés, donnés ou intentés, à la suite de ou en rapport, directement ou indirectement, avec les procédures concernées. Graco Information For the latest information about Graco products, visit www.graco.com. TO PLACE AN ORDER, contact your Graco distributor or call to identify the nearest distributor. Phone: 612-623-6921 or Toll Free: 1-800-328-0211 Fax: 612-378-3505 All written and visual data contained in this document reflects the latest product information available at the time of publication. Graco reserves the right to make changes at any time without notice. This manual contains English. MM 312473 Graco Headquarters: Minneapolis International Offices: Belgium, China, Japan, Korea GRACO INC. P.O. BOX 1441 MINNEAPOLIS, MN 55440-1441 Copyright 2007, Graco Inc. is registered to ISO 9001 www.graco.com Revised 08/2009