Standard HRiM Editing Techniques

Similar documents
Standard HRaM Editing Techniques. Standard HRaM Editing Techniques

Chicago Classifications. Quick Start Guide for Suite P

Sailwave Scoring Instructions for Thursday Night Races 2017

WMS 8.4 Tutorial Hydraulics and Floodplain Modeling HY-8 Modeling Wizard Learn how to model a culvert using HY-8 and WMS

Users Group Conference 2018

Chromat Calibration Updated October 27th, 2017

Mapping a Magnetic Field. Evaluation copy. Figure 1: Detecting the magnetic field around a bar magnet

Armfield Distillation Column Operation Guidelines

ACQUIDATA FAMILY CALIBRATION PROCEDURE CALIBRATION CHECKING

iworx Sample Lab Experiment HE-5: Resting Metabolic Rate (RMR)

Calculations of hydraulic resistance of simple pipelines for liquid viscous and non-newtonian products.

Lab 3. The Respiratory System (designed by Heather E. M. Liwanag with T.M. Williams)

CT Transcatheter Aortic Valve Replacement (TAVR) Planning VPMC-13165C

CHRVA Referee Certification Process

Boyle s Law: Pressure-Volume Relationship in Gases

iworx Sample Lab Experiment HE-5: Resting Metabolic Rate (RMR)

Experiment 11: The Ideal Gas Law

Cardiovascular and respiratory adjustments to exercise

Utilizing intraluminal pressure differences to predict esophageal bolus flow dynamics

Trial # # of F.T. Made:

Biology 347 General Physiology Lab Basic Pulmonary Functions: Respirometry and Factors that Effect Respiration

Investigating Natural Gas Production and Consumption with Web GIS

ARCCOS 360 NEW USER GUIDE

iworx Sample Lab Experiment HE-4: Respiratory Exchange Ratio (RER)

Module No GETTING ACQUAINTED GENERAL GUIDE TIMEKEEPING

FIG: 27.1 Tool String

Respiration. Exercise 1A: Breathing in Resting Volunteers Aim: To measure breathing parameters in a resting individual.

Figure 1 Example feature overview.

Superconducting Susceptometer (MPMS-5S) Quantum Design Room 296 (MPMS)

Experiment HS-2: Breathing and Gravity

Lab 13: Hydrostatic Force Dam It

Cover Page for Lab Report Group Portion. Boundary Layer Measurements

Page 2 of 46 Prepared by: Engr. Ram Sankar

Operating Manual. BACVis. Manual BACVis. for. Sensors and MilliGascounter. Rev

Restrictive and Obstructive Airway Diseases

Lucid System In-Service Training

v2.3 USER MANUAL

TrackMan Operator Training

SmartMan Code User Manual Section 5.0 Results

Experiment HE-9: Resting, Active, and Exercising Metabolic Rates

Experiment HE-9: Resting, Active, and Exercising Metabolic Rates

Set-up, programming and analysis RotorGene 3000/6000, Rotor-Gene Q

Tutorial 2 Time-Dependent Consolidation. Staging Groundwater Time-dependent consolidation Point query Line query Graph Query

Saphir Guided Session #8

Lung Volumes and Capacities

ALGE DIVE! ALGE. ALGE-TIMING GmbH & Co

B04 Guided Interpretation #4

Quantitative Analysis of Hydrocarbons by Gas Chromatography

UNITY 2 TM. Air Server Series 2 Operators Manual. Version 1.0. February 2008

SS32L Dissolved O 2 Probe

Microsoft Windows Software Manual for FITstep Stream Version 4

Quick Start Guide. For Gold and Silver Editions

Diver-Office. Getting Started Guide. 2007, Schlumberger Water Services

Variable Temperature Operation

Plié 3 Microprocessor Knee

CHRVA Scorer Certification Process Adult Provisional Scorer Certification Requirements

RESPIRATORY PHYSIOLOGY, PHYSICS AND PATHOLOGY IN RELATION TO ANAESTHESIA AND INTENSIVE CARE

5890II GC Standard Operating Procedure 9/2/2005

[MYLAPS INTEGRATION]

Hydrus 1D Tutorial. Example: Infiltration and drainage in a large caisson. 1) Basic model setup. Sebastian Bauer Geohydromodellierung

PowerStroke TM Operating Instructions. November 2015 PROTECTED BY ONE OR MORE OF THE FOLLOWING US PATENTS 7,387,029; 7,377,180; D528,451

APA software instruction manual

Lesson 12 New Procedure PULMONARY FUNCTION I

FROG-4000 TM Chemical Analysis System

GETTING STARTED. Main MENu SCREEN: When starting E6, the Main Menu screen displays the following buttons:

Table of Contents Diagnosis ICD9 to ICD10 GEM Report... 1 Diagnosis Form... 5 Helpful Hints on Correcting Issues... 8 Disclaimer...

TR Electronic Pressure Regulator. User s Manual

Cardiac Output Simulation for Specific Makes of Monitor. Each injection yields in a time-temperature curve whose area represents the cardiac output:

EXPERIMENT 12 GAS LAWS ( BOYLE S AND GAY-LUSSAC S LAW)

Lab #1 Pressure: Bubblers and Water Balloons CEE 331 Fall 2003

Experiment AMe-1: Small Animal Respiratory Exchange Ratio (RER)

Quick Start Guide. A. Hardware installation B. Software installation C. Start the software for the first time D. Do your first measurement

Sesam HydroD Tutorial

In Response to a Planned Power Outage: PPMS EverCool II Shut Down and Re-start Procedure

BLOOD PRESSURE SENSOR BT17i USER S GUIDE

Start - All Programs - Class Software - Scratch - Scratch move move move Sound play drum move move move play drum Control forever forever forever

IRBManager Instructions

Roster Maintenance. How-to Access Your Club Roster

Wave Load Pattern Definition

A RAPID PULL-THROUGH TECHNIQUE FOR MEASURING LOWER ESOPHAGEAL SPHINCTER PRESSURE

ThopEasy + INSTRUCTIONS FOR USE. Precious life Progressive care. Thopaz. Thopaz+

Downloading/Transferring Golf Courses

Biology 347 General Physiology Lab Human Diving Response

GA-300 Gas Analyzer. Technical Note. Overview. Front Panel. iworx Systems, Inc. GA-300

Student Exploration: Distance-Time Graphs

Air Ball! Evaluation copy

For clarification or assistance with TDM-web or any USTA web-based application,

DRS25 PROCESS DEVELOPMENT GUIDE.

FireHawk M7 Interface Module Software Instructions OPERATION AND INSTRUCTIONS

Mechatronic System Design (ENT473)

Magellan crosses the Atlantic Ocean

Table of Content IMPORTANT NOTE: Before using this guide, please make sure you have already set up your settings in

McKnight Hockey Association

Lab 4: Pressure Gradients over a Wing

EXPERIMENT XI. Careful!! Improper handling of the vacuum line may result in the release of SO 2 which is an irritating and suffocating gas.

Section 2: Using the Invasive Blood Pressure Module - An Introduction

New Cortex Software User Guide

ClubHub. User s Guide

DANGER WARNING IMPORTANT

CENTER PIVOT EVALUATION AND DESIGN

Transcription:

Standard HRiM Editing Techniques

Opening the Study: Double click on the Sandhill Applications icon on the desktop. Click 'Analysis'. Click 'Select Patient': The path to find the patient file is: C:\Sandhill\Patients\EFT Temperature Compensation Change Time to 1 minute. Scroll to the end of the study. Click once just after the probe was removed from the patient. A flashing reference line will appear. Click 'Edit' on the Toolbar. Click 'Create Compensation. This will adjust the ClouseVIEW colors based on patient body temperature. Click 'OK'. LES Profile: Gastric Baseline, Distal, PIP, Proximal Click 'Ranges' on the Toolbar. Select '0 LES Profile'. Turn off the ClouseVIEW. 2

Correct the Gastric Baseline Measurement: *Zero all channels so that each waveform is positioned on the zero axis: Click and drag the zero axis to the waveform. **Adjust the measurement box size to avoid any areas of contraction: Click and drag the side of the box to adjust box Scroll to the next visible yellow box in order to be positioned at the proper probe depth: Distal, PIP and Proximal should be annotated after the probe depth mark in the study. PIP: Starting from the distal waveforms, identify a positive pressure wave with respiration by clicking once on a peak wave. A flashing reference line will appear. Follow the reference line proximally until a negative wave is identified with respiration. (the waves will invert at the point of the diaphragm.) Right Click and select 'Create Event', Name the event PIP. Choose the channel where the wave has inverted. Click OK Turn on ClouseVIEW and turn off waveforms. 3

Click and drag the dotted reference bar to the bottom of the LES color band. Right Click and select 'Create Event', Name the event 'Distal'. The channel and location will automatically be identified by the software when in the ClouseVIEW mode. Click OK. Click and drag the dotted reference bar to the top of the LES color band. Right Click and select 'Create Event', Name the event Proximal. The channel and location will automatically be identified by the software when in the ClouseVIEW mode. Click OK. Lower Body/LES: MII Swallow, Swallow-Relax Click 'Ranges' on the Toolbar. Select '1 Lower Body-LES' Turn off the ClouseVIEW. Esophageal Baseline: The Esophageal Baseline and the LESP are both acquired at the same time. The Esophageal Channels are the 4 proximal pressure channels. The Esophageal Baseline measurement is located directly above the LESP. Correct the Esophageal Baseline Measurement. Activate the Esophageal box by clicking anywhere within the measurement box. A black dashed line will always indicate the active measurement box: **Zero all channels so that each waveform is positioned on the zero axis: Click and drag the zero axis to the waveform. **Adjust the measurement box size to avoid any areas of contraction: Click and drag the side of the box to adjust box. 4

Open the Analysis Tool and click on the LESP measurement directly below the Esophageal Baseline. The LES channels are the distal 5 pressure channels. **Adjust the measurement box size to avoid any areas where a swallow or peristaltic wave is present: Click and drag the side of the box to adjust the measurement box. Observe the LESP data in the analysis box. The number displayed in bold is the high pressure zone and will be the reported value. ****IMPORTANT: Once the Baselines and LESP have been edited, the software must reanalyze all measurements based on these corrections. Click 'Analyze' in the Toolbar and select 'Analyze All measurements'. Do Not Re-Analyze again. MII Swallow: Impedance rules for Complete Bolus Transit: 1. The bolus must have entry in the proximal impedance channel... wave drops below 50% threshold (dotted line) of the baseline. 2. The bolus must exit in the distal 3 channels... wave rises above 50% threshold (dotted line) of the baseline. 3. The bolus must accomplish Complete Bolus Transit within 15 seconds and remain complete for at least 5 seconds. 5

Evaluate each impedance measurement (Liquid and Viscous): Complete BT: Yes: No editing is required. Complete BT: No (Time): No editing is required. Complete BT: No (Exit): Verify. IF Exit is not observed, no editing is required. Complete BT: No (Exit): Verify. IF Exit is observed, edit as follows: 6

Expand the right side of the measurement box so that all exits and a 5 second recovery is included. If Analysis still does not correct the measurement, right click in the missing channel and add the bolus exit. Swallow-Relax Measurements These measurements measure the pressures in the esophagus and lower esophageal sphincter during a swallow. The proximal 4 pressure channels are designated to measure the esophageal activity. These channels will have 2 vertical lines indicating begin and end of contraction and an 'X' indicating the peak of contraction. The distal 5 channels are designated to calculate the relaxation of the sphincter. Note: All 5 channels may not be in the sphincter depending on the patient's LES length. The LES channels will have an 'X' indicating the point of relaxation during the swallow. 7

Relaxation Editing: First look in the Analysis box and find the channel labeled LES that has the Black bold number. This is the channel the software has selected as the highest residual pressure in the measured area and will be the reported value. Verify the position of the 'X' so that it is within the peristaltic wave and that this channel is within the true sphincter. (Use Clouse VIEW to verify.) Ignore any respiration changes when identifying LES relaxation. The basal pressure should decrease. Clouse VIEW: The five closely spaced waves should be at the level of the LES. 8

If the 'X' is not in the correct position, click and drag the 'X' to the correct position. ***Note: At times, you may need to use a different channel than the software identifies. Corrected : The 'X' was moved to the correct position and the relaxation data is now correct. Esophageal Body Editing: The proximal 4 pressure channels are positioned 5,10,15 and 20 cm above the LES. The vertical lines identify the onset and completion of the contraction at each level. The 'X' identifies the Peak or highest pressure within the contraction. The onset and end of contraction lines should be positioned at the main upstroke and downstroke of the contraction waves. 9

If needed, Click and drag the vertical line to the correct position: At times, the software will incorrectly identify intrabolus pressure as the onset point. Corrected Contraction Onset: **Note it is very important to accurately identify onset points in the distal 2 channels when evaluating Onset Velociy (peristalsis) Periodically Click the Save button in your Tool Bar. UES and Upper Body Study: UESOB, UESP, UES Coordination Click 'Ranges' on the Toolbar. Select '2 Upper Body- UES'. Scroll back to the beginning of the study. The upper pressure channels are now visible. 10

Correct the Esophageal Baseline Measurement for the upper body: *Zero all channels so that each waveform is positioned on the zero axis: Click and drag the zero axis to the waveform. **Adjust the measurement box size to avoid any areas of contraction: Click and drag the side of the box to adjust box. Corrected Esophageal Baseline Create the UESP (Upper Esophageal Sphincter Pressure): Scroll to the first Liquid Swallow marker (LS). Identify a quiet area just before the swallow. Click and drag across all channels where a rise off baseline is identified. The rise in pressure signifies the Upper Esophageal Sphincter. A green box will indicate the selected area. Right Click and select 'Create Measurement'. Name the Measurement 'UESP'. Click OK 11

Create the Pharyngeal Baseline: Click and drag across all channels above the UESP measurement. A green box will indicate the selected area. Right Click and select 'Create Measurement'. Name the Measurement 'Pharyngeal Baseline'. Click OK. Creating UES Coordination Measurements: During the Liquid Swallow, identify the most proximal UES channel. Click and drag across and up during the UES whole relaxation during the swallow to include the proximal UES channel and 3 Pharyngeal channels. (The UES wave will look like a 'J' or 'M' during relaxation.) Right click and select 'Create Measurement'. 12

First: Name the Measurement 'UES Coordination'. Then uncheck the 2 middle pharyngeal channels. This will allow for movement of the UES during the swallow. Click OK. Create 3-5 Liquid UES Coordination measurements. Open the Analysis Tool. Click on each UES Coordination measurement. Pharyngeal Channel: Adjust the vertical lines as needed: The onset and end of contraction lines should be positioned at the main upstroke and downstroke of the contraction wave. The 'X' is positioned at the peak of contraction. UES Channel: Adjust the vertical lines as needed: The onset and end of relaxation lines should be positioned at the beginning and end of the relaxation. (Downstroke and upstroke of the middle of the 'M' or 'J'. The 'X' should be positioned at the lowest point of relaxation, smoothing out the curve. 13

Create Upper Body Measurements. Scroll to the first Liquid Swallow Measurement. Identify the first channel just below the UES: During the swallow, a contraction will be observed. Click and drag across the contraction during the Liquid Swallow. Only 1 channel should be selected. Right click and select 'Create Measurement' Name the Measurement, 'Swallow UESOB' Click OK. Create 3-5 Liquid Upper Body Swallow measurements. Open the Analysis Tool. Click on each Swallow UESOB measurement and edit: Adjust the vertical lines as needed: The onset and end of contraction lines should be positioned at the main upstroke and downstroke of the contraction wave. The 'X' is positioned at the peak of contraction. 14

Procedure Report Once ALL measurements are edited, Create the Report: Click 'Report' in the Toolbar. Click 'Create Report' Click 'OK' The Report will then start creating the thumbnails of the measurements to be included in the report. A Thumbnails Preview screen will open. Unselect All. Review each thumbnail and select as many or few thumbnails to be included in the report. Once all thumbnails are selected, click 'OK' Review the Report data. Print 15

Sandhill University... Innovators in Clinical Education The objective of Sandhill University is to provide clinical users with the knowledge and skills necessary to effectively acquire and analyze High Resolution Impedance-Manometry studies, impedance-ph reflux monitoring studies and anorectal manometry studies. Sandhill University Online Courses Webinars Cybercoaching Sandhill SuperVision As the global leader in G.I. diagnostics, Sandhill Scientific continues to offer state-of-theart clinical education courses throughout the world. To learn about courses in your area of the globe, please contact a Sandhill representative. Corporate Headquarters 102 East Keefe Avenue Milwaukee, WI 53212 USA 800.558.6408 or 414.265.7635 Fax 414.265.7628 sales@sandhillsci.com orders@sandhillsci.com Technical Research & Training Center 9150 Commerce Center Circle #500 Highlands Ranch, CO 80129 USA 800.558.6408 or 303.470.7020 Fax 303.470.2975 technicalsupport@sandhillsci.com clinicalsupport@sandhillsci.com clinicaleducation@sandhillsci.com 2015 Sandhill Scientific, All rights reserved. PL-14-009 Rev. 2