2 Properties Table 1 Window Operating forces Resistance to wind load Air permeability Watertightness Impact resistance Load-bearing capacity of safety devices Change of dimension EN 12046 EN 1026 EN 12211 EN 1027 EN 49 EN 14351 -% of test specimen overall area -% / +% of test specimen overall area -% of frame width and height of test specimen -% / +% of test specimen overall area > test specimen overall area Dry and silicone glazing, glazing beads of steel, stainless steel and aluminium -% of test specimen overall area 01.535 12.540 32.518 35 12.540 32.518 32.7 01.535 12.540 32.518 18 32.7 32.335 32.7 35 12.540 32.518 0 32.335 single leaf side-hung window FFB x FFH 825 x 2040 Fittings: 907110-907111, 907122-907124 double leaf side-hung window FFB x FFH 1640 x 2040 Fitting: 907119-907120 0 3 C3/B3 5A 3 Requirement (0 Pa) (1200 Pa) (200 Pa) (4mm) fulfilled single leaf side-hung window FFB x FFH 825 x 2040 Fitting: 907110-907111, 907122-907124 double leaf side-hung window FFB x FFH 1640 x 2040 Fitting: 907119-907120 Sealing pieces: 9 and 9151 bottom and top 0 4 C3/B3 7A 3 Requirement (0 Pa) (1200 Pa) (300 Pa) (4mm) fulfilled 18 32.7 0 32.335 32.335 single leaf side-hung window FFB x FFH 825 x 2040 Fitting: Giesse PROVENCE (fixed-point mounting) double leaf side-hung window FFB x FFH 1640 x 2040 Fitting: Giesse PROVENCE (fixed-point mounting) Sealing pieces: 9 and 9151 bottom and top 2 3 C2/B2 6A 2 Requirement (0 Pa) (0 Pa) (2 Pa) fulfilled Locking piece in steel, bottom and top, in-house production FFB = leaf rebate width FFH = leaf rebate height
3 Properties Table 1.1 Window 01.535 01.535 12.540 12.540 32.518 32.518 01.535 12.540 32.518 Operating forces Resistance to wind load Air permeability Watertightness Impact resistance Load-bearing capacity of safety devices Change of dimension 01.535 12.540 32.7 32.518 32.7 32.7 EN 12046 EN 1026 EN 12211 EN 1027 EN 49 EN 14351 -% of test -% / -% of -% / > test -% of test specimen +% of test frame width +% of test specimen specimen overall area specimen and height of specimen overall area overall area overall area test specimen overall area Dry and silicone glazing, glazing beads of steel, stainless steel and aluminium 32.7 32.335 32.335 01.535 01.535 12.540 12.540 32.335 32.518 32.518 single leaf tilt and turn casement window (with and without screen abutment) FFB x FFH 826 x 2040 Forster fitting with Euro-groove 1 4 C2/B2 5A 3 Requirement (0 Pa) (0 Pa) (200 Pa) (4mm) fulfilled 32.335 32.7 32.7 01.535 01.535 0 32.518 12.540 12.540 32.518 32.518 7 32.7 32.7 32.335 32.335 2.519 12.540 32.518 single leaf tilt and turn casement window (with and without screen abutment) FFB x FFH 826 x 2040 Forster fitting with Euro-groove 1 4 C2/B2 9A 3 Requirement (0 Pa) (0 Pa) (0 Pa) (4mm) fulfilled Fixed glazing: seal the glass rebate on bottom and sideways (up to 200mm height) with "Tremco Illbruck sealing strip TwinAktiv W" 32.335 32.335 32.335 2.8 32.7 01.535 12.540 32.518 2.635 32.335 32.7 30 32.335 FFB = leaf rebate width single leaf tilt and turn casement window (with and without screen abutment) FFB x FFH 826 x 2040 Fitting: Giesse PROVENCE (fixed-point mounting) 2 2 C2/B2 3A 3 Requirement (300 Pa) (0 Pa) ( Pa) (4mm) fulfilled Fixed glazing: seal the glass rebate on bottom and sideways (up to 200mm height) with "Tremco Illbruck sealing strip TwinAktiv W" Locking piece in steel, bottom and top, in-house production combined side hung & tilt and turn casement window FFB x FFH 1640 x 2040 Forster fitting with Euro-groove Sealing pieces: 9152 und 9153 bottom and top 0 4 C3/B3 4A 3 Requirement (0 Pa) (1200 Pa) (1 Pa) (4mm) fulfilled FFH = leaf rebate height
4 Acoustic performance Window Forster presto/norm EN ISO 140-1, EN 20140-3, EN ISO 717-1 Change of dimension: see EN 14351-1, table B3 Dry and silicone glazing, glazing bead in steel, stainless steel and aluminium Window Forster presto/norm, single leaf Glass: R w,p 40 db R W (C;C tr) = 40 (-2; -5) db FFB 1170mm x FFH 1420mm Glass: R w,p 42 db R W (C;C tr) = 42 (-3; -8) db FFB 1170mm x FFH 1420mm Fitting: - Roto 32.0 32.3 32.1 Window Forster presto/norm, 32.1 double leaf Glass: R w,p 40 db R W (C;C tr) = 40 (-1; -4) db FFB 1170mm x FFH 1420mm 32.5 32.3 2.0 32.3Glass: R w,p 42 db R W (C;C tr) = 41 (-2; -5) db FFB 1170mm x FFH 1420mm Fitting: - Roto.0 32.3 32.1 32.5 32.3 32.1 2.5 32.0 32.3 Window Forster presto/norm, single leaf 32.3 Glass: R w,p 36 db R W (C;C tr) = 36 (-2; -5) db FFB 11mm x FFH 1430mm Glass: R w,p 37 db R W (C;C tr) = 38 (-1; -5) db FFB 11mm x FFH 1430mm Fitting: - C-rail fitting (907111) 32.7 32.851 32.1.0 32.3 32.1 32.5 32.3 0032.3 32.7 32.851 Window Forster presto/norm, double leaf Glass: R 2.5 32.3 w,p 36 db R W (C;C tr) = 36 (-2; -6) db FFB 11mm x FFH 1430mm Glass: R w,p 37 db R W (C;C tr) = 40 (-3; -7) db FFB 11mm x FFH 1430mm Fitting: - C-Schienen-Beschlag (907120).532.7 32.3 32.851 32.7 32.851 Fixed glazing Forster presto/norm Glass: R w,p 36 db R W (C;C tr) = 35 (-2; -6) db B 985mm x H 2110mm Glass: R w,p 37 db R W (C;C tr) = 37 (-2; -6) db B 985mm x H 2110mm 32.7 32.851 32.7 32.851 LB = clearance width LH = clearance height B = Dimension of outer frame width H = Dimension of outer frame height See table 1 and table 1.1 for mandated properties according to product standard EN 14351-1.
5 Thermal transmittance Window Forster presto/norm 32.5 32.0 32.5 32.032.5 32.3 32.5 32.3 U 1 1 f = 6,4 W / (m 2 x K) U f = 6,6 W / (m 2 x K) 1 32.5 32.0 1 32.5 32.3 EN ISO 77-2 90 90 Filling components thickness: 24mm 32.5 32.0 profiles: steel, stainless steel 90 Window Forster presto/norm with Euro-groove 32.852 32.852 02.635 02.635 1 1 32.5 32 90 2.5 32.0 32.5 32.032.5 32.3 32.5 32.3 90 90 32.7 32.7 Window Forster presto/norm with standard sealing groove U f = 6,1 W / (m 2 x K) 32.852 32.852 U f = 6,6 W / (m 2 x K) 02.635 02.635 32.852 02.635 32.852 32.7 01.535 01.535 32.523 12.0 32.523 12.0 01.535 32.523 12.0 32.7 2.635 Window Forster presto/norm with sealing corner groove U f = 7,0 W / (m 2 x K) U f = 7,6 W / (m 2 x K) U f = 6,8 W / (m 2 x K) 1 1 1 8 32.7 32.7 01.535 01.535 32.523 12.0 32.523 12.0 77 77 32.5 32.0 32.5 32.0 32.5 32.5 32.3 32.0 32.5 32.3 32.5 32.3 Transoms Forster presto/norm U f = 8,1 W / (m 2 x K) U f = 6,8 W / (m 2 x K) U f = 8,3 W / (m 2 x K) 77 77 0 77 90 90 90 32.852 32.852 32.852 02.635 02.635 02.635 See table 1 and table 1.1 for mandated properties according to product standard EN 14351-1.
6 CE conform applications presto/norm Fenster Seal the ends of the transom profiles seal with sealing compound art. no. 9001 Drainage of the horizontal profiles (leaf and glazing) 0 View A Horizontal profiles, standard version (Watertightness up to 200 Pa) 9 Ø 9.5 A min. 5mm Horizontal profiles with sealed glass rebates (Watertightness up to 0 Pa) seal with suitable sealing compound or foil against water diffusion
7 CE conform applications Water and steam decompression Steam decompression on leaf A 23 5 15 Ø8 Section A Water decompression on leaf Ø8 22 Section B Water decompression on frame B 9101 Section C 9 C
8 CE conform applications Water and steam decompression Steam decompression on leaf A 16 5 22 Ø8 35 Ø8 Section A Water decompression on leaf Section B Water decompression on frame B 9101 Section C 8 C
9 CE conform applications Water and steam decompression Steam decompression on leaf A Water decompression on leaf 16 35 5 Ø8 Ø8 19 Section A Section B B 9101 Water decompression on frame Section C 9 C
10 CE conform applications presto/norm Fenster Tilt- and top-hung windows Windows with corner seal also in construction depth 40 mm Connection of elements Compression tape or suitable sealing
11 Not CE conformed applications (npd) Segment arch and pitched window npd (no performance determined) Glazing beads with spring clip npd (no performance determined) Double sided glazing beads npd (no performance determined)