MICRO DIAPHRAGM LIQUID PUMPS DATA SHEET NF 100/1.100 NF 100 / 1.100

Similar documents
MICRO DIAPHRAGM GAS PUMPS

DIAPHRAGM VACUUM PUMPS AND COMPRESSORS

MINI DIAPHRAGM VACUUM PUMPS AND COMPRESSORS

DIAPHRAGM PRESSURE CONTROL VALVE FDV 30 / 31, FDV 1.30 / 1.30 FDV 300 / 301, FDV / 1.301

MINI DIAPHRAGM VACUUM PUMPS

DIAPHRAGM VACUUM PUMPS AND COMPRESSORS

MICRO DIAPHRAGM GAS PUMPS

Willkommen. Welcome to KNF - presentation

DIAPHRAGM PUMPS WITH KNF STABILIZATION SYSTEM

CHEMICALLY RESISTANT DIAPHRAGM GAS SAMPLING PUMPS

DIAPHRAGM VACUUM PUMPS AND COMPRESSORS

CHEMICALLY RESISTANT DIAPHRAGM GAS SAMPLING PUMPS

DIAPHRAGM GAS SAMPLING PUMPS

DIAPHRAGM VACUUM PUMPS AND COMPRESSORS

LIQUID PUMPS ACCESSORIES OVERVIEW

Pocket Bellows Pumps. 180 Hines Ave. Bellville, OH PH: FAX:

DIAPHRAGM GAS SAMPLING PUMPS

DIAPHRAGM VACUUM PUMPS WITH KNF STABILIZATION SYSTEM

MINI DIAPHRAGM VACUUM PUMPS

GAS SAMPLING PUMPS WITH KNF DOUBLE DIAPHRAGM SYSTEM

DIAPHRAGM VACUUM PUMPS AND COMPRESSORS

Instruction Manual Contact Pressure Vacuum Gauge

DIAPHRAGM VACUUM PUMPS AND COMPRESSORS

Expert Hydrostatic Level Transmitters

Best Practices for Installation of Gaseous Sample Pumps

2 Overview. SITRANS P measuring instruments for pressure. Transmitters for gage and absolute pressure. Z series for gage pressure

Accessories for Sanitary Installations

N SERIES PROCESS VACUUM PUMPS AND COMPRESSORS

Instruction Manual. LKHSP Self-Priming Centrifugal Pump (Appendix) ESE02222-EN

Pressure relief valve DHV 712 DN 65-80: 0,5-10 bar, DN : 0,3-4 bar, DN 100: 0,5-6 bar

HAYWARD FLOW CONTROL Series PBV Back Pressure Valve and Series RPV Pressure Relief Valve INSTALLATION, OPERATION, AND MAINTENANCE INSTRUCTIONS

DIAPHRAGM VACUUM PUMPS AND COMPRESSORS

HUMOR 20. High-precision Humidity Calibrator HUMOR 20. Operation

SITRANS P measuring instruments for pressure

GRUNDFOS DATA BOOKLET. Hydro Solo-E. Complete pressure boosting systems 50/60 Hz

CASH VALVE TYPE KP BACK PRESSURE VALVES

OPERATING INSTRUCTIONS MANUAL FOR QACV PNEUMATIC DOSING PUMP

Diaphragm Vacuum Pumps and Compressors

Pressure relief valve DHV 716 set range: 0,5-10,0 bar

Glass tube flowmeters Series 2000

DataSheet. Series AA Electronic Metering Pumps. Configuration Data. Dimensions. Specifications. Model AA HI. ISO 9001 Certified

PULSAR4 Pressure regulating valve (Unloader)

Modulating Valves for Atmospheric, Infrared, and Direct Fired Burners

Pressure Relief Valve DHV 718

ANNEX AMENDMENTS TO THE INTERNATIONAL CODE FOR FIRE SAFETY SYSTEMS (FSS CODE) CHAPTER 15 INERT GAS SYSTEMS

TROUBLESHOOTING GUIDELINES

VB85/ Pressure regulating valve (Unloader)

Level switches Series LD Vibrating fork level switch for liquids and solids

Compact pressure switches for gas and air

Level switches Series LD Vibrating fork level switch for liquids and solids

Pressure Transmitter P41

TOP VALVE. Pat. #5,857,486 & 5,944,050. Mid-Range Pressure PSIG Back Pressure and Pressure Relief Valves. Instruction Manual

2-step solenoid valve Type ICLX

MINI GAS SAMPLING PUMPS WITH DOUBLE DIAPHRAGM SYSTEM

Pneumatic valve islands

Pressure Reducing Valve DMV 750 set range: bar

OPTIBAR P 1010 C Technical Datasheet

SAFETY MANUAL FOR FLAMMABLE PRODUCT TRANSFER

better measurement Simply a question of SCHMIDT Flow Sensor SS The cost-effective alternative in pressurised systems up to 10 bars.

ALPHADYNAMIC has filed with the TUV NORD certification body the documentation certifying

BACK PRESSURE / SUSTAINING

Accessories. Valves. Adjustable Pressure Relief Valves

Compressors. Basic Classification and design overview

MJK Expert 700 / 800 / 900 / 7070 / 7060 MJK Expert 1400 / 3400

Diaphragm-Gas Sampling Pumps with double diaphragm System N 143 AN.12 E N 143 AV.12 E. N 143 SN.12 E N 143 SV.12 E Operating and

Liquid ring vacuum pumps in compact design

Tubes Components Valves Units Engineering SO EVERYTHING KEEPS FLOWING. Safety valves Bunging valves Vacuum valves Tank dome fittings

Solenoid valve type EVR for Hydrocarbons

DANFLO Control Valves 400 Series Model 20

Solenoid valves VZWF, force pilot operated

DIAPHRAGM VACUUM PUMPS AND COMPRESSORS

OWNER S TECHNICAL MANUAL

2/2-Way Solenoid Control Valve

How to specify a product. Process Sensors and Mechanical Instruments

E 158 E 198 E 248. Tank top mounting Connection up to G11 / 4 Nominal flow rate up to 250 l/min e d

Liquid ring vacuum pumps in compact design

TBV-CM. Combined control & balancing valves for small terminal units For modulating control

E 328 E 498 Tank top mounting Connection up to G1½ and SAE 2 Nominal flow rate up to 600 l/min

VRPP 200/280 Pressure regulating valve by pneumatic control

Pressure Reducing Valve DMV 755

PULSAR4 Pressure regulating valve (Unloader)

TECHNOLOGIES. M Series. Positive return metering pumps [API675]

Liquid ring vacuum pumps in compact design

Body Material: PVC, PP, PVDF Bonnet Material: Glass Filled PP Size: ½ - 2 Pressure Rating: 150 psi Set Pressure: 4 to 150psi Seals:

Measurement of Low GAS & Liquid Flows

OFFICINE OROBICHE S.p.A. 1/9

Pressure relief valve DHV 725 set range: 0,2-10,0 bar

Instruction Manual Differential Pressure Transmitter

Liquid ring compressors

M/MR Modulating Valves TABLE OF CONTENTS DESCRIPTION SPECIFICATIONS. For Atmospheric, Infrared, and Direct Fired Burners

TA-COMPACT-P. Combined control & balancing valves for small terminal units Pressure independent balancing and control valve (PIBCV)

QUICK CONNECT FOR 2.0, 4.0 & 5.0 GASES

2-step solenoid valve Type ICLX

Your local gas generation partner. Precision series Modular gas generation solution for GC.

Inverse Prop. Pressure-Relief Cart., Size 2 4

Cash Valve TYPE KP PILOT OPERATED BACK PRESSURE VALVE. ISSUED - DECEMBER 2000 CAVMC-0518-US-0208 ISO 9001 Certified

Hydrostatic. Continuous level measurement. Overview Page 188 VEGAWELL 52 Page 190 VEGABAR 86, 87 Page 192 Accessory Page 196 AL-EN

Gas Injection Systems

VERTICAL AIR COMPRESSORS

2-port and 3-port seat valves, PN16

Transcription:

MICRO DIAPHRAGM LIQUID PUMPS DATA SHEET /1.100 / 1.100 KP.51 DC NF 1.100 KPE KP.27 AA Concept KNF diaphragm liquid pumps are based on the principle of the oscillating displacement pump which is remarkably simple in design. The circular power from the motor is convert ed into vertical movement by an eccentric. This motion is then transferred to a diaphragm by means of a connecting rod which in conjunction with an inlet and outlet valve creates a pumping action. /1.100 type liquid pumps can be mounted in any position and can deliver up to 1.3 l/min depending on the model and will operate against pressures of up to 60 mwg. The KNF modular system contains a wide standard range of materials, motors, voltages and frequencies to enable the selection of an optimal solution for your application. Features Self-priming and excellent for pressure Sophisticated diaphragm technology and precise valve structures enable performanc es, depending on model, of up to 4 mwg suction and 60 mwg pressure. Extreme chemical resistance The use of chemically resistant materials such as, PVDF, or other material combinations for the parts which come in contact with the liquid allows almost all neutr al or corrosive liquids to be pumped. Dry running, durable and maintenance free The carefully considered design of these pumps allows them to be run dry and ensures safe operation and a long life even under the most severe conditions. Areas of use The versatility of KNF pumps allows a wide field of applications to be covered. Over many years our pumps have proved themselves in the follow ing areas: Analysers Medical / pharmaceutical Environmental / water treatment Food / toxicology Laboratory Filtration Chromatography Cleaning industry Cuvette cleaning Sterilisers Industrial washing machines Printing Ink jet printing Photographic / film development Other applications for diaphragm liquid pumps include: fuel cells, hydrogen generators, CD coating, dental technology, textiles and many more. Data Flow rate Suction Pressure 1.2 3 10 NF 1.100 1.3 3 60

Basic models General note This Data Sheet provides an overview of the options with our /1.100 pumps. Certain standard options will be explained in more detail where necessary. Flow curves The flow curves illustrate how the flow rate alters in relation to the pressures before and after the pump. In the case of a combination of both we would be very happy to advise what the expected flow rate would be. The values given in the curves are dependant upon the liquid, choice of materials and the type of hoses being used. Therefore a cert ain deviation is to be expected. Note: The flow rate is measured with water at C. Basic models Copying of this document and giving it to others and the use or communication of the contents thereof, are forbidden without expre ss authority. Offenders are liable to the payment of damages. All rigths are reserved in the event of the grant of a patent or the registration of a ity util model or design. Liquid diaphragm pump for pressures of up to 10 mwg (1 barg).27 Integrated overpressure relief valve The integrated overpressure relief valve is available for all /1.100 pumps. How it works If the pump runs against a closed system the pressure will increase rapidly thus exceeding the allowed limits. In order to prevent this from happening a relief valve has been integrated into the. Should the pressure exceed the adjusted value (min. 1.5 barg), the valve will open allowing the liquid to pass through the built-in bypass from the outlet to the inlet side. Note: The valve is adjusted in the factory to a standard value of 1.5 barg () and 6.5 barg (NF 1.100). Adjusting bolt Locknut Spring.27 NF 1.100 Liquid diaphragm pump for pressures of up to 60 mwg (6 barg) 1 Materials of components KNF FLODOS offers a wide range of different materials for those parts which come in contact with the liquid thus allowing the possibility of pumping most liquids. Weitergabe sowie Vervielfaeltigung ieser d Unterlage, Verwertung und Mitteilung ihres Inha lts nicht gestattet, soweit nicht ausdruecklic h zugestanden. Zuwiderhandlung verpflichten zu Scha denersatz. Alle Rechte fuer den Fall der Patent erteilung oder 2 types - Standard The pump of the /1.100 is made up of the following main parts. The diaphragm, intermediate plate, connection plate, O Ring, resonating diaphragm and the valves are the only parts which come in contact with the liquid. The materials which are available as standard can be seen in the table. Gebrauchsmuster-Eintragung vorbehalt en. Areas of use The valve can be used to prevent damage from occurring to the pump itself, hoses, valves and the system as a whole due to excessive press ures which can build up because of blockages Ersetzt durch or faulty valves. Replaced by 00 Zeichnungsfreigabe 29.09.1...... Rev. Aenderungen / Modification Dat. Ersatz fuer Massstab Scale 3:2 Replacement for Freigabe / Format Toleranzen Material DIN ISO 2768-mH Tolerances Size Kasten = - >6 >30 >1 <0 DIN A3 <6 <30 <1 0.1 0.2 0.3 0.5-2.5x Grösse Datenblatt 3 Motors Typ / (Pro/E: Sprachen über Folien gesteuert) Benennung / 162399 Zeichnungnu Description DB ZEICHNUNG KOPF.27 3.8.01 E Shaded pole motor (AC) plate O-Ring Connection plate AA DC DCB Capacitor motor (AC) Direct current motor Brushless direct current motor This type of motor has no brushes which can wear down thus giving it a lifetime comparable with an AC motor. Option: control possibility via PWM or 0-5V DC signal Intermediate plate 4 Voltages / Frequencies Choose from the different electrical connection possibilities. Special variations are available.

-E / AA -DC / DCB -E 1.2 3 10 -AA 1.2 3 10 -DC 1.2 3 10 -DCB 1.2 3 10 E AA Voltage (V) 230V / 50Hz 230V / 50Hz Power rating (W) 43 86 I max. load. (A) 0.37 0.36 I max. (A) 0.43 0.50 EMV guideline EN 55014 EN 55014 Weight (g) 1100 2430 Motor protection factor IP 00 IP 54 DC DCB Voltage (V) 6 / 12 / 24 12 / 24 Power rating (W) 26 / 26 / 24 11 / 11 I max. load. (A) 1.07 / 0.9 / 0.3 0.67 / 0.37 I max. (A) 4.4 / 2.2 / 1.0 0.93 / 0.46 EMV guideline EN 55014 EN 55014-1 1) EN 6100-2-6 Weight (g) 600 4 Motor protection factor IP 50 IP 30 1) In order to comply with the above standards attention must be paid to the specifications in the operating instructions. -E -DC.27 E.27 DC E 31.5 63.5 DC 86 71 71 102 (109) 22.5 63.5 4x 4.3 45 61 5 27 4x M4 109 300 42 -AA -DCB.27 AA.27 DCB AA 124 (131) 119 DCB 250 75 4x 5.5 70 184 93 105 116 75 45 4x 4.3 54 Flow curve -E /-AA Flow curve -DC /-DCB 1. 1. 1. 0. 0..27 1. 0. 0..27 0. 6 4 2 0 2 4 6 8 10 0. 6 4 2 0 2 4 6 8 10 Suction [mwg] Pressure [mwg] Suction [mwg] Pressure [mwg]

NF 1.100-E / AA NF 1.100-DC / DCB NF 1.100-E 1.3 3 60 NF 1.100-AA 1.3 3 60 NF 1.100-DC 1.3 3 60 NF 1.100-DCB 1.3 3 60 E AA Voltage (V) 230V / 50Hz 230V / 50Hz Power rating (W) 66 86 I max. load. (A) 0.42 0.36 I max. (A) 0.50 0.50 EMV guideline EN 55014 EN 55014 Weight (g) 1600 2450 Motor protection factor IP 00 IP 54 DC DCB Voltage (V) 6 / 12 / 24 12 / 24 Power rating (W) 39 / 33 / 34 18 / 18 I max. load. (A) 2.7 / 1.3 / 0.5 1.29 / 0.75 I max. (A) 6.5 / 2.8 / 1.0 1.50 / 0.75 EMV guideline EN 55014 EN 55014-1 1) EN 6100-2-6 Weight (g) 7 500 Motor protection factor IP 50 IP 30 1) In order to comply with the above standards attention must be paid to the specifications in the operating instructions. NF 1.100-E NF 1.100-DC NF 1.100.27 E NF 1.100.27 DC NF 1.100 E G1/8" G1/8" 31.5 63.5 NF 1.100 DC 86 71 71 102 (109) 63.5 22.5 45 136 4x 4.3 61 5 27 4x M4 124 300 42 NF 1.100-AA NF 1.100-DCB NF 1.100.27 AA NF 1.100.27 DCB NF 1.100 AA 124 (131) 119 NF 1.100 DCB 250 4x 5.5 75 70 184 93 105 116 45 83 4x 4.3 54 Flow curve NF 1.100-E /-AA Flow curve -DC /-DCB 1. 1. 1. 1. 0. 0. NF 1.100.27 NF 1.100 0. 0. NF 1.100.27 NF 1.100 0. 6 4 2 0 10 30 50 60 0. 6 4 2 0 10 30 50 60 Suction [mwg] Pressure [mwg] Suction [mwg] Pressure [mwg]

The KNF Modular Concept of Selection Modules Our versatile self-selection program allows you to personally determine the optimum characteristics that you require from your pump. Select your diaphragm pump from the following characteristics: atmos. pressure Pump type Basic model 1.2 3 10 1.3 3 60 NF 1.100 Components 1 2 3 4 1 Werkstoffe (Kopfmaterialien) 2 types KP / KP.51.27 PP EPDM EPDM - Standard model.27 Integrated overpress relief valve KT TT FT.27.27 PP PVDF 3 Motors E AA DC DCV Shaded pole motor (AC Capacitor motor (AC) Direct current motor Brushless direct current motor 4 Voltages / Frequencies 230V / 50Hz 115V / 60Hz 100V / 50-60Hz for AC motors * food conformity according to the standard NSF/ANSI 169, details see options 6 / 12 / 24V for DC motors 12 / 24V for DCB motors

Accessories Options pressure control valve The pressure control valve can be used for a more accurate control of flow against a fluctuating back pressure, metering into a vacuum and from a pressurised system. Used correct it can save pumps, plumbings and other fittings from damage. NSF National Sanitary Foundation NSF is market leader in the development and controlling of standards relevant for equipment used for handling foodstuffs. By using different toxicological tests our products will be certified according to the standard NSF/ANSI 169. This certification will confirm that all of the pumps with the code.51 are certified for the use with foods/consumables. In addition to this it also means that the pumps are constructed with wetted parts which come with a FDA* declaration of conformity. A yearly audit from NSF will be carried out to ensure that these standards are being maintained. A list of the various products are available on request. * FDA = Food and Drug Administration Further options Special hose connections: UNF 1/4-28, compression fitting for ID 4mm; OD 6mm hosing Suitable for pressures over 1.0 bar Other materials Motors with special voltages and frequencies The incorporation of customers special requirements, or example special electrical connections (Molex, AMP, etc.) Pulsation damper This very versatile pulsation damper reduzes the vibration in hoses and pipes and it helps to remove pulsation which is preventing the system from functionning correctly. It also protects instrumentation connected after the pump. Further accessories Hoses Hoses connections Shock mounts We specialise in tailor made solutions. For all the possible options feel free to contact us. KNF FLODOS AG, Wassermatte 2, 6210 Sursee, Switzerland - www.knf-flodos.ch, info@knf-flodos.ch Technical Status: 11/12 Printed in Switzerland KNF FLODOS reserves the right to make technical changes ID Nr. 067 629