GAS FRYER Instruction Manual Model #5099NS

Similar documents
UNIVERSAL GAS FRYER Instruction Manual Model #8065NS


Birdie Ball Game Instruction Manual Model #7756- Birdie Ball Insert Model #7757-Alley and Tub

Parts Manual. Frusheez Machines

Standard Gas Countertop Griddle

Gas Countertop Hot Plates

INSTALLATION AND OPERATING INSTRUCTIONS BIG TEX VENTED GAS LOGS

installation instructions

For use with select HPC Fire Pits ONLY- refer to product catalog or website. 100K BTU Maximum WARNING: FOR OUTDOOR USE ONLY

Installation Instructions

INSTALLATION AND OPERATING INSTRUCTIONS

OPERATING INSTRUCTIONS

INSTALLATION & OPERATION MANUAL FOR Stockpot Range

INSTALLATION, OPERATION, SERVICE & PARTS MANUAL FOR STOCK POT RANGE MODELS VSP100, VSP200 & VSP300

Natural Gas High-Altitude Conversion Kit For Installations in the United States (2,001 10,000 Feet)

Installation Instructions WARNING: WARNING: WARNING: LP AND HIGH ALTITUDE LP GAS CONVERSION KIT FOR UNITED STATES INSTALLATIONS

G196 Series BASOTROL Redundant Combination Gas Valve with Manual Shutoff Valve

Operator Manual Gas Griddle / Cheesemelter

ROBERT H. PETERSON CO. AUTOMATIC REMOTE LIGHTING SAFETY PILOT SYSTEM WITH VARIABLE FLAME-HEIGHT REMOTE FOR NATURAL OR PROPANE GAS. Model APK-17(M)(P)

G196 Series BASOTROL Redundant Combination Gas Valve with Manual Shutoff Valve

/2004 US/CA

SUMMITTM 400 & 600. Natural Gas Barbecues. Step-By-Step Guide

ESG35T * * Installation & Operation Manual. For Service, Call (318) Price: $6.00

JACKSON GRILLS PATIO FIRE

ACCESSORIES MAY BE PURCHASED SEPARATELY.

Natural Gas Conversion Kit

INSTALLATION & OPERATION MANUAL FOR Teppan-Yaki Griddles

ASSEMBLY & OPERATING INSTRUCTIONS

Your safety and the safety of others are very important.

Installation and Operation Instructions

INSTALLATION INSTRUCTIONS MANUAL ON/OFF SAFETY VALVE/PILOT KIT MODEL GA9050A-1 (F0235)

G96 Series BASOTROL Dual Operator Valve

Natural Gas to L.P. Gas Conversion Kit

WARNING: Installation Instructions. Natural Gas High Altitude Conversion Kit United States Installations Only

WARNING: FOR OUTDOOR USE ONLY

Natural Gas to L.P. Gas Conversion Kit

Installation Instructions

Instruction Manual for the Globe Gas Stock Pot Range Model: GSP18G

INSTRUCTION MANUAL. Gas Salamander

Congratulations! Hand Held Torch. Warranty Policy PARTS

Gas Countertop Griddle

Robert H. Peterson Company

ACCESSORY KIT INSTALLATION INSTRUCTIONS

USER MANUAL Wok Range

INSTALLATION GUIDE Gas Rangetops

ACCESSORY KIT INSTALLATION MANUAL

GAS VALVE RETROFIT KIT Pull Through Tube Heater Models

DANGER. Keep this Manual in a Convenient Location for Reference

Tri-Safem Model I1 Regulator. INSTRUCTIONS and PARTS

OWNER S MANUAL 28" GRIDDLE COOKING STATION

BGA158 Series CE Approved Class B Shutoff Gas Valve

Thanks for shopping with Improvements! Monterey Propane Fire Column Item #574852

ASSEMBLY & OPERATING INSTRUCTIONS

Sweeper Dual Control. Automatic Sweeper Switching System SW SERIES SWEEPERS SW-4815 SW-4820 SW-4825 MAGUIRE PRODUCTS INC.

Owners Manual Models: 075-AQF-CX. Aquatrol Backwashing Catalytic Carbon Filter. Visit us online at.

Dual Solenoid Gas Valve Installation

BGA158 Series CE Approved Class A Shutoff Gas Valve

G92 Series BASOTROL Automatic Pilot Gas Valve

OWNER'S MANUAL WARNING WARNING WARNING WARNING. Factory No.: HYFP Item No.: 67668ST

GAS FUEL VALVE FORM AGV5 OM 8-03

HOT SHOT OPERATING INSTRUCTIONS AND OWNER S MANUAL. Model SPC-500. (Propane Torch)

Owner's Manual and Instructions

60 farm jack. Distributed exclusively by Harbor Freight Tools Mission Oaks Blvd., Camarillo, CA 93011

AUTOMATED INDUSTRIAL MACHINE, INC

MODEL CALIBRATION GAS DELIVERY SYSTEM

APCO ASU-SCAV & ASU-CAV SINGLE BODY COMBINATION AIR VALVES

Installation Instructions JATCO Environmental Protection Tank Model J-5000CX

WATER HEATER THERMAL EXPANSION TANKS Owner s Manual. Safety Instructions Installation Maintenance Warranty. Models: 2-5 Gallon Capacity

TOP VALVE. Pat. #5,857,486 & 5,944,050. Mid-Range Pressure PSIG Back Pressure and Pressure Relief Valves. Instruction Manual

VOLLEYBALL SPIKE TRAINER. Assembly Instructions. Owner s Manual. Model # VST-400. Club Volleyball Gear

SSFU SUPER SPRAYFAST UNIVERSAL ADHESIVE APPLICATOR

Operating and Maintenance Instructions

453 Series Steam Heated Vaporizing Regulator

Types 749B and R130 Changeover Manifolds

WARNING: Gas Conversion Kit Instructions Applies to: Model UDAP, UDAS, UDBP, and UDBS Unit Heaters. General and Warnings FOR YOUR SAFETY

SUMMITTM 475 & 675. Natural Gas Barbecues. Step-By-Step Guide THIS GAS APPLIANCE IS DESIGNED FOR OUTDOOR USE ONLY.

Installation, Operation and Maintenance Manual

INSTALLATION & OPERATION MANUAL GAS RESTAURANT RANGES

Gas Conversion Kits Push Through (Positive Pressure) Tube Heater Models

GAS SUPPLY APPLICATION GUIDE

Yoke Block Instruction Manual

Viking Installation Guide

HYDRAULIC WINCH FOR AUGERS UP TO WR10 X 71 / W130 X 41 ASSEMBLY & OPERATION MANUAL

Type S301 & S302 Gas Regulators INTRODUCTION INSTALLATION. Scope of Manual. Description. Specifications. Type S301 and S302. Instruction Manual

2000 lb manual winch

INSTRUCTIONS FOR CONVERTING CONDENSING GAS MOBILE HOME FURNACES MODEL SERIES: CMA3*, CMC1*, VMA3*, VMC1*

BGA158, BGA171 and BGA110 Series Shutoff Gas Valve

The conversion of new certified central heating gas appliances must conform to directions outlined in this instruction.

WEATHERIZING INSTRUCTIONS

VR8200A Continuous Pilot Combination Gas Controls

Model B-1 Pipe Line Strainer 3, 4, 6 & 8 Inch (DN80, DN100, DN150 & DN200) 175 psi (12,1 bar) General Description. Technical Data

Gas Conversion Kits CERAMIC HEATER SERIES (1, 2, 3, 4 Burner Units)

ROBERT H. PETERSON CO.

ACCESSORY KIT INSTALLATION INSTRUCTIONS

1 Square = Foot/Feet Revision G 1/18/2013 Titan Controls

ULTRA HIGH PRESSURE PAINT GRATE CLEANER FCT-JS OPERATION AND MAINTENANCE MANUAL

GM-7000 Series CE Approved Gas Control Valve

ACCESSORY KIT INSTALLATION INSTRUCTIONS

FPK Spark Ignition Safety Manual Installation & Operation Instructions. This Product is for use with Natural Gas Only.

Operating Manual. Model 25200B/25202B Refrigerant Recovery Unit. (Not for use in automotive R-134a applications)

Transcription:

Part No. 89932 Revised: March 2004 GAS FRYER Instruction Manual Model #5099NS Cincinnati, OH 45241-4807 USA

GAS SAFETY PRECAUTIONS GAS FUNNEL CAKE FRYER 2 MODEL #5099NS

GAS FUNNEL CAKE FRYER SAFETY PRECAUTIONS 3 MODEL #5099NS

OPERATING INSTRUCTIONS GAS FUNNEL CAKE FRYER UNPACKING AND ASSEMBLY After unpacking your GAS FUNNEL CAKE FRYER, set it on a counter where you intend to use it. Remove all tape. Observe the following clearances: Front and sides: 10 inches Back and front: 10 inches Ensure proper clearances for air supply and maintenance. NOTE: Locate the fryer on a base that is strong enough to safely support the fryer when full of oil. To restrain fryer use 3/8-16 bolts through the counter into tapped holes in the bottom of the fryer. INSTALLATION: When installing your GAS FUNNEL CAKE FRYER, you must conform with local codes, or in the absence of local codes, with National Fuel Gas code, ANSI Z223.1 (latest edition). NOTE: Some local codes may require ventilation hoods or automatic fire systems. During any pressure testing of the gas supply piping system at pressure equal to or less than ½ psig (3.45 kpa), the appliance must be isolated from the gas supply piping system by closing its individual manual shutoff valve. After installation, all gas connections must be checked for leaks with a soap solution. TYPES OF GAS The data plate is marked at the factory to indicate the type of gas the appliance uses. The 5099NS is designed for Propane only. 4 MODEL #5099NS

GAS FUNNEL CAKE FRYER ALTITUDE RANGE: The factory has sized the orifices for elevations up to 2000 feet above sea level. For high altitude applications, please contact Gold Medal customer service. NOTE: This fryer must be attached to a 100 pound LP cylinder. This fryer will not operate properly on small (20-40 lb.) cylinders. GAS PRESSURE We have determined that optimum frying occurs when the gas pressure is adequate. For propane gas, we recommend a manifold pressure setting of 11 inches of water column. The pressure is measured at the appliance when the main burner is ignited. LIGHTING AND SHUT DOWN INSTRUCTIONS Follow these steps to light your unit: 1. Turn the gas safety valve to the PILOT position. 2. Depress the button next to the safety valve handle. 3. Light the pilot burner with a household match. Continue to hold the safety valve button for approximately 30-45 seconds. Release the safety valve button and the pilot burner will remain lit. 4. Turn the gas safety valve handle to the ON position. The main burner will ignite. 5. To extinguish both the pilot and the main burner flames, lift the lock button on the gas safety valve and turn the safety valve handle to the OFF position. 6. Should the burner become extinguished because of the high-limit tripping, shut off the gas supply until the fryer cools down, then re-ignite. If the pilot is turned off, a 5 minute shutdown period is required before relighting. FILLING THE OIL TANK The tank will hold 50 lbs. of cooking oil. The surface on this amount of oil will be approximately 2 ¾ inches above the bottom of the tank. NOTE: Cooking oil expands upon heating. Do not overfill the tank as overfilling could result in a dangerous situation. 5 MODEL #5099NS

ORDERING SPARE PARTS GAS FUNNEL CAKE FRYER 1.Identify the desired part by checking it against the photos, illustrations, and/or the parts list. 2.When ordering, please include part number, part name, and quantity desired. 3.Please include your model name and machine serial number (located on the machine nameplate) with your order. 4.Address all parts orders to: Parts Department Gold Medal Products Co. 10700 Medallion Drive Cincinnati, Ohio 45241-4807 or, place orders at: (513) 769-7676 Fax: (513) 769-8500 E-mail: goldme19@eos.net 6 MODEL #5099NS

GAS FUNNEL CAKE FRYER Control Valve P/N/ 89679 Safety Valve 74027 Not Shown: 89166 Burner with Tips 89920 Regulator with 5 foot hose 4300 Dial Thermometer 8055 Fine Mesh Skimmer 89014 Tank Drain Valve Aluminum Tube P/N 74561 High Limit Control P/N 89615 Wire Assy. P/N 89767 (2) Thermocouple P/N 89762 11 in. w.c. regulator P/N 89916 Pilot Burner Assy. P/N 74032 Bracket - 89754 7 MODEL #5099NS

GAS FUNNEL CAKE FRYER WARRANTY WE WARRANT to the original purchaser the Gold Medal equipment sold by us to be free from defects in material or workmanship under normal use and service. Our obligation under this warranty shall be limited to the repair or replacement of any defective part for a period of six (6) months from the date of sale to the Original Purchaser with regard to labor and two (2) years with regard to parts and does not cover damage to the equipment caused by accident, alteration, improper use, voltage, abuse, or failure to follow instructions. THIS WARRANTY IS IN LIEU OF ALL OTHER WARRANTIES EXPRESSED OR IMPLIED, AND OF ALL OTHER OBLIGATIONS OR LIABILITIES ON OUR PART, INCLUDING THE IMPLIED WARRANTY OF MERCHANTIBILITY. THERE ARE NO WARRANTIES WHICH EXTEND BEYOND THE DESCRIPTION ON THE FACE HEREOF. We neither assume, nor authorize any other person to assume for us, any other obligation or liability in connection with the sale of said GOLD MEDAL equipment or any part thereof. The term Original Purchaser as used in this warranty shall be deemed to mean that person, firm, association, or corporation who was billed by the GOLD MEDAL PRODUCTS COMPANY, or their authorized distributor for the equipment. THIS WARRANTY HAS NO EFFECT AND IS VOID UNLESS THE ORIGINAL PURCHASER FIRST CALLS GOLD MEDAL PRODUCTS COMPANY AT 1-800- 543-0862 TO DISCUSS WITH OUR SERVICE REPRESENTATIVE THE EQUIPMENT PROBLEM, AND, IF NECESSARY, FOR INSTRUCTIONS CONCERNING THE REPAIR OR REPLACEMENT OF PARTS. NOTE: This equipment is manufactured and sold for commercial use only. GOLD MEDAL PRODUCTS COMPANY 10700 Medallion Drive Cincinnati, Ohio 45241-4807 USA 8 MODEL #5099NS