Rupture Disc Sizing for Micro Motion Coriolis Sensors

Similar documents
Micro Motion Pressure Drop Testing

44 (0) E:

S.A. Klein and G.F. Nellis Cambridge University Press, 2011

Case Study Results on Natural Gas Custody Transfer Measurement with Coriolis Meters in Saudi Arabia

Challenges in Relief Design for Pilot Plants

The capacity of the cargo tank venting system (46 CFR );

Device Description. Operating Information. CP Q (eq. 1) GT. Technical Bulletin TB-0607-CFP Hawkeye Industries Critical Flow Prover

CALCULATING THE SPEED OF SOUND IN NATURAL GAS USING AGA REPORT NO Walnut Lake Rd th Street Houston TX Garner, IA 50438

Tube rupture in a natural gas heater

Design and Safety Document for the Vacuum Windows of the NPDGamma Liquid Hydrogen Target at SNS

ONSITE PROVING OF GAS METERS. Daniel J. Rudroff WFMS Inc West Bellfort Sugar Land, Texas. Introduction

Applied Fluid Mechanics

Installation Manual , Rev BC January Micro Motion R-Series Coriolis Flow Sensors

Operational Settings:

For Multi-Parameter Meters see mvx

This portion of the piping tutorial covers control valve sizing, control valves, and the use of nodes.

No E. General Information. Averaging Pitot Tube Flow Sensor HITROL CO., LTD.

Installation Manual MMI , Rev AA April Micro Motion TA-Series Flow and Density Meters

TEK-THERMAL 1700B. Thermal Mass Flowmeter. FLOW. Technology Solutions

Vortex Tube Short Course February 2017

Comments on Homework. Quiz. Class 3 - Pressure. Atmospheric Pressure. 2. Gauge vs. Absolute Pressure. 1. Definitions. Temperature conversion

COMPAFLOW. Compressed Air. Volumetric flow. Gas. Mass flow. Steam. Net volumetric flow. Liquid

Micro Motion H-Series Hygienic Coriolis Flow and Density Meters

For Multi-Parameter Meters see mvx

Restriction Orifice. Single or Multi Stage Orifice to. Reduce Pressure or. Limit the Flow Rate

Comments on Homework. Class 4 - Pressure. Atmospheric Pressure. Gauge vs. Absolute Pressure. 2. Gauge vs. Absolute Pressure. 1.

SB AXIAL FLOW VALVES

REFERENCE GUIDE. Rev. 0 15/09/2016

ONSITE PROVING OF GAS TURBINE METERS Daniel J. Rudroff Invensys Metering Systems

Impact of imperfect sealing on the flow measurement of natural gas by orifice plates

Modeling a Pressure Safety Valve

ASHRAE made significant changes in 2001 to the calculations. Fundamentals of Safety Relief Systems

A Study of Pressure Safety Valve Response Times under Transient Overpressures

I. CHEM. E. SYMPOSIUM SERIES NO. 85

Looking Beyond Relief System Design Standards

A REVIEW OF THE 2000 REVISIONS TO ANSI 2530/API MPMS 14.3/AGA REPORT NO. 3 - PART2 Paul J. LaNasa CPL & Associates

Tank Blanketing Pressure Regulators RHPS Series

Types 627W and 627WH Direct-Operated Pressure Reducing Liquid Regulators

Design Review Agenda

COMMITTEE DRAFT. API 520 Part I 10 th Edition Ballot Item 2.1. This ballot covers the following item:

Steam generator tube rupture analysis using dynamic simulation

Safety Aspects and Design of the Vent Isolation Chamber. Prepared: W.M. Snow Checked: H. Nann Approved: W. M. Snow

Permeability. Darcy's Law

MONROE BROTHERS LTD Customer Sigmaphi Project JLab Dipole Safety Relief MB / Description Chimney Vent Capacity & Pressure Drop 301 Issue 1

Test Report # Rev 0. Adiabatic Compression With Constant Bleed Valve

North American 7339 High Pressure Gas Regulators

627 Series Pressure Reducing Regulators

Tutorial. BOSfluids. Relief valve

Ron Gibson, Senior Engineer Gary McCargar, Senior Engineer ONEOK Partners

FUNDAMENTALS OF PRESSURE REGULATORS ROBERT BENNETT MANAGER OF TRAINING ELSTER AMERICAN METER

The API states the following about tube rupture for a shell-and-tube heat exchangers:

NORDCALC Introduction... 2 Registration... 2 Flow Calculations tab Torque Calculation & Actuator Mounting Data tab... 21

STANDARD SPECIFICATION FOR FLOW INSTRUMENTS DOCUMENT NO : 44-LK /J.02/0006-A4

Installation Operation Maintenance

Type 299 Pressure Reducing Regulators

Pro-V Multivariable Flowmeter

North American Orifice Metering System

INSTRUMENTATION EQUIPMENT

Single & Headered Relief Vent Piping Analysis

Ball Float Steam Trap UNA 45 MAX, UNA 46 MAX, UNA 46A MAX PN 40/Class 300 DN 40, 50, 65

Becker* Products Below Ground Ball Valve Regulators

OVERVIEW OF THE CONVAL 10 SERVICE RELEASES

TWO PHASE FLOW METER UTILIZING A SLOTTED PLATE. Acadiana Flow Measurement Society

Variable Area Flow Meters

Integral type Differential pressure flowmeter VNT Series

FLOW MEASUREMENT WITH ORIFICES. Types: BLS500 / BLS550

Ratio Regulator Zero Governor. FRG/6 Series

6.6 Relief Devices. Introduction

Hand-operated regulating valves in stainless steel Types REG-SA SS and REG-SB SS

Water Hammer In Irrigation Systems 1

Lab # 03: Visualization of Shock Waves by using Schlieren Technique

Write important assumptions used in derivation of Bernoulli s equation. Apart from an airplane wing, give an example based on Bernoulli s principle

Chapter 22 Testing Protocols

VALVCHEQ BACKFLOW PREVENTERS FIGURE RP03

Pro-V Multivariable Flowmeter Model M22 In-line Vortex

Blast Damage Consideratons for Horizontal Pressure Vessel and Potential for Domino Effects

COMPONENT AVAILABILITY EFFECTS FOR PRESSURE RELIEF VALVES USED AT HYDROGEN FUELING STATIONS

Guide for Evaluating Your Hose Assembly Supplier

Continuous Flow Gas Lift Design By Jack R. Blann 2/9/2008 1

Micro Channel Recuperator for a Reverse Brayton Cycle Cryocooler

Limited quantities of compressed gases.

THE NATURAL CHOICE. High end valves for the natural gas value chain. Inspired By Challenge

Installation Manual , Rev BB December Micro Motion H-Series Hygienic Coriolis Flow and Density Sensors

1 Exam Prep NFPA 99 Health Care Facilities Questions and Answers (Plumbing Contractor)

Use equation for the cylindrical section and equation or for the ends.

Flow in a shock tube

IRC 2011 All Rights Reserved

Detailed Thermal Inbreathing Analysis for API 12-F Tanks

Wet Gas Flowmetering Guideline

GP1 & GP2. Electropneumatic Regulators FOR PRESSURE CONTROL TO 1,000 PSI

Standard Pneumatic Test Procedure Requirements for Piping Systems

Vortex Flow Meter Wafer or Flange Connection. - Steam - Liquid - Gas

ACCURATE PRESSURE MEASUREMENT FOR STEAM TURBINE PERFORMANCE TESTING

Hall C SHMS Q2, Q3, and Dipole: Magnet Pressure Safety. Eric Sun. October 12, Experiment Readiness Review of Physics Division.

INTRODUCTION TO REGULATOR AND RELIEF VALVE SIZING. Introduction

How to Optimize the Disposal System With Staggered Analysis Using BLOWDOWN Technology. Jump Start Guide

FLAMMABLE GASES AND FLAMMABLE CRYOGENIC FLUIDS

Fisher L2sj Low Emission Liquid Level Controller

Cover Page for Lab Report Group Portion. Compressible Flow in a Converging-Diverging Nozzle

Study to Establish Relations for the Relative Strength of API 650 Cone Roof Roof-to-Shell and Shell-to- Bottom Joints

Transcription:

Rupture Disc Sizing for Micro Motion Coriolis Sensors www.emerson.com/micromotion

Rupture Disc Sizing White Paper 1 Introduction Emerson s Micro Motion Coriolis flow meters are widely used in many industries that require high accuracy flow and density measurements. Micro Motion Coriolis meters are designed to the ASME B31.3 standard, and are classified as part of the Process Pressure Piping, which is used in most customer installations worldwide. The process fluid is contained within a pressure boundary formed by two process connections, two manifolds and two tubes, all welded together. The flow tubes, which make the mass flow measurement, are contained inside an outer housing (case) which protects them from the environment. Please refer to Figure 1 for a visual representation of the components described above. The sensor s electronics are contained within an outer enclosure. The feedthrough is a glass-tometal seal that provides a means for the electrical circuits to pass to the electronics and serves as a secondary seal. meter case. Furthermore, a few standards exist in the industry that provide guidance on the use of Rupture Disk in applications, please see Table 1 below. This white paper deals with how Micro Motion sizes rupture disks for our Coriolis meters. Table 1: Industry Standards API MPMS 5.6 (Manual of Petroleum Measurement Standards Chapter 5 Metering, Section 6 Measurement of Liquid Hydrocarbons by Coriolis Meters) ISO 10790 (Measurement of Fluid Flow in Closed Conduits Guidance to the Selection, Installation and Use of Coriolis Meters) ISA 12.27.01 (Requirements for Process Sealing Between Electrical Systems and Flammable or Combustible Process Fluids) Electronics Feedthrough Figure 1: Depiction of Coriolis meter Manifolds Flanges Tubes inside outer housing Micro Motion Coriolis flow meters are used in a wide variety of applications that cover many different pressure ranges. Many Micro Motion Coriolis meters have, at least, a primary containment pressure rating of 1450 psig. There are also Micro Motion Coriolis meters that have an even higher primary containment pressure rating that goes up to 15,000 psig. In certain applications, the case that protects the tubes has a burst pressure below the primary containment pressure of the tubes. Some customers want to add an extra measure of safety to their piping system by having a rupture disk installed in the Coriolis 2 Sizing Methodology The primary design goal for a rupture disk is to size the disk orifice large enough to allow for any pressurized fluid to exit the case before the pressure within the case can exceed its safe working pressure. A methodology has been put in place to size the rupture disk using compressed gas theory. Compressed gas that enters the case, due to a breach in the flow tube, is the worstcase condition because the pressurized gas expands as it enters the case. Fluids that are incompressible do not expand as it exits the flow tube and is therefore a much less catastrophic condition. Sizing a rupture disk for compressed gas will also encompass the needs of liquid applications. Cryogenic applications are not considered in this analysis and further calculations should be performed before selecting a rupture disk for cryogenic applications. The model used for sizing the rupture disk is taken from an article published in Hydrocarbon Processing, February 1992. Important references in this article are Crane Technical Bulletin 410, API RP 520 and API RP 521. Although the Hydrocarbon Processing article is directed at shell and tube heat exchangers, it has direct applicability to the sensor s pressure containment design. Figure 2 shows a cross-section of a Coriolis meter s pressure boundary which will be used as the model to develop the sizing methodology. Three distinct areas Page 2

Rupture Disc Sizing are shown in the diagram, inside the flow tube (line pressure), inside the case, outside of case (atmospheric pressure). Flow Tubes P 1 T 1 P c T c Case Rupture Disk Patm Tatm Example location for tube rupture (e.g. orifice) Assuming two concepts from fluid dynamics, continuity of flow and the choked fluid flow is limited by the sonic velocity across the tube breach, it is then possible to determine the mass flow rate exiting the rupture disk and the fluid pressure inside the case. The rupture disk area is sized to maintain a pressure within the safe pressure containment region of the case. In this analysis, the worst-case condition is assumed, the flow through the tube rupture is assumed to be steady state choked flow. Assuming ideal gas behavior, steady-state choked flow occurs when the downstream pressure falls below a critical pressure. The critical pressure at the throat of the orifice is given by Equation 1, where k is the ratio of specific heats for the gas. Figure 2: Cross section of flow meter pressure boundaries The model can be considered as three different volumes, each with a thermodynamic state defined by pressure and temperature. The three volumes are: Volume 1 inside flow tube (system pressure), Volume 2 inside the case, Volume 3 outside the case (atmospheric conditions). The process conditions of the primary containment are known. The atmospheric conditions outside the vent are assumed to be standard conditions. The state of the fluid in the case volume is dependent upon the state of the fluid in the other two volumes and the flow rate of process fluid through the tube rupture. In the event the sensor s primary containment fails due to a breach in the flow tube, the process fluid will flow into the case and then from the case to the atmosphere. A detailed discussion of how the crack size is determined is discussed in Appendix A. The breach opening for all sensors is assumed to be 40% of the wall thickness in width and 180 around one tube. Assuming the process pipeline has a limitless supply of fluid, the maximum flow exiting the cracked tube is then limited by the sonic velocity of the expanding gas (the crack is acting as an orifice). The flow is sonic (Mach 1) at the throat of the tube crack, and cannot exit any faster due it being choked flow. This is an important fluid dynamics principle that governs the analysis in this paper. The flow rate cannot increase even if the downstream atmospheric conditions change, because the sonic condition at the throat still exists. Equation 1: Critical pressure for choked flow The mass flow rate (lb/hr) through the rupture disk is given by Equation 2, and is a function of: the area of the breach, A (in2); the process pressure P 1 (psi); the upstream fluid density, ρ (lb/ft3); and the pressure drop, dp (psi). The pressure drop used in Equation 2 is the lesser of the two values as calculated by Equation 3. Equation 2: Mass flow through the tube rupture Equation 3: Pressure drop across tube rupture Using Equations 1, 2, and 3 it is possible to determine the size of the rupture disk opening necessary to prevent the pressure within the case from exceeding a safe pressure. Page 3

Rupture Disc Sizing White Paper 3 Example Calculation The F100P will be used as an example for calculating the required size of the rupture disk. The scenario used to determine the size of the rupture disk is the tube ruptures and pressurizes the case, at the same time the rupture disk is venting enough fluid out of the case to ensure a safe pressure is always maintained inside the case. All the rupture disk sizes are calculated in the same manner. Cryogenic applications are not considered in this analysis. The input values for this example calculation are shown in Table 2. The flow conditions are also shown graphically in Figure 3. The first step is to start with Equation 1 and determine the critical pressure of the tube rupture, which is found to be 3419 psia. Steady state choked flow happens when the downstream pressure is lower than the critical pressure. The max pressure in the case can only be 865 psia which is lower than the critical pressure causing the choked flow through the tube rupture. The choked flow condition governs the mass flow rate that can exit the rupture. Table 2: Input values for F100P Calculation Fluid Natural Gas k 1.3 ID 0.547 in Wall thickness 0.086 in Crack size 0.034 in width 180 around one tube (half-moon shape) A 0.0171 in P 1 6265 psia T 1-40 C Pc 864 psia Tc -40 C Patm 14.7 psia Tatm 60 C Rupture disk size 1.0 in Rupture disk relief pressure 64 psig Process line density 22.3 lb/ft3 The second step is to check the critical pressure at the throat of the rupture disk. The ambient pressure (14.7 psia) is below the critical pressure of 471 psia, thus the rupture disk is also choked. The third step is to determine the pressure drop value to be used in Equation 2, which is calculated using Equation 3. The pressure drop across the tube rupture has the lower pressure drop and is the value to be used to determine the mass flow rate. Figure 3: Simplified diagram of Coriolis pressure boundary with flow conditions Volume 1 High pressure side P 1 =6265 psia T 1 =-40 C Volume 2 Low pressure side P c =864 psia T c =-40 C Volume 3 Back pressure side Patm=14.5 Psia Tatm=60 C P critical = 3419 psia P critical = 471 psia Tube Wall Breach Area Tube Wall Case Wall Page 4

Rupture Disc Sizing The fourth step is to calculate the mass flow rate exiting the tube rupture using Equation 2. The fifth step is to calculate the required rupture disk area. The mass flow exiting the case must be equal or greater than the mass flow exiting the tube breach. Therefore, rupture disk must flow 5443 lb/hr out of the case to maintain a safe pressure of 865 psia in the case. Rearranging Equation 2 and solving for the area gives the required rupture disk area and diameter. The F100P requires a rupture disk diameter of 0.40 in. The F100P sensor has a rupture disk of 1.0 inch installed which exceeds the minimum requirement. 4 Summary A methodology is discussed that calculates the rupture disk size based on the theories laid out in steady state choked flow. The example discussed above shows the methodology used to calculate rupture disk installed on Coriolis sensors at Micro Motion. The rupture disk sizes for Micro Motion sensors are listed in Table 3. Table 3: Sensor Case Diameters Sensor Diameter (in) CMF010H 0.5 CMF010L 0.5 CMF010M 0.5 CMF010P 0.5 CMF025H 0.5 CMF025L 0.5 CMF025M 0.5 CMF050H 0.5 CMF050L 0.5 CMF050M 0.5 CMF100H 0.5 CMF100L 0.5 CMF100M 0.5 CMF200A 1.0 CMF200B 1.0 CMF200H 0.5 CMF200L 0.5 CMF200M 0.5 CMF300A 1.0 CMF300B 1.0 CMF300H 0.5 CMF300L 0.5 CMF300M 0.5 CMF350A 1.0 CMF350M 1.0 CMF350P 1.0 CMF400A 1.0 CMF400B 1.0 CMF400H 1.0 CMF400M 1.0 CMF400P 1.0 CMFHC2A 1.5 CMFHC2M 1.5 CMFHC3A 1.5 CMFHC3M 1.5 CMFHC4M 1.5 CMFS007M 0.5 Sensor (continued) Diameter (in) CMFS010H 0.5 CMFS010M 0.5 CMFS010P 0.5 CMFS015H 0.5 CMFS015M 0.5 CMFS015P 0.5 CMFS025H 0.5 CMFS025M 0.5 CMFS025P 0.5 CMFS040M 0.5 CMFS050H 0.5 CMFS050M 0.5 CMFS050P 0.5 CMFS075M 0.5 CMFS100H 0.5 CMFS100M 0.5 CMFS100P 0.5 CMFS150H 0.5 CMFS150M 0.5 CMFS150P 0.5 F025A 0.5 F025B 0.5 F025H 0.5 F025P 0.5 F025S 0.5 F050A 0.5 F050B 0.5 F050H 0.5 F050P 0.5 F050S 0.5 F100A 0.5 F100B 0.5 F100H 0.5 F100S 0.5 F100P 1.0 F200H 0.5 F200S 0.5 F300H 0.5 F300S 0.5 HPC010P 0.5 Page 5

Appendix A: Determination of Tube Crack Size The primary containment breach dimension and size are the most important assumptions made in this analysis. Micro Motion experience has shown that if there is a relief path between the high-pressure gas (e.g. a rupture disc) and atmosphere, catastrophic case failure does not occur. When a crack forms in the tube, gas simply escapes into the secondary case and pops the relief feature at low pressure (64 psi). When the relief feature pops, gas flows in a controlled manner to atmospheric conditions. Micro Motion has studied a number of tube failures over the years and has used that data to develop an understanding of a typical tube crack size. A typical failed tube is shown in Figure 4. The tube crack is on a ½ diameter tube with a wall thickness of 0.062 inches. Process fluid was natural gas at approximately 3500 psi. As noted in the figure the crack is less than 0.01 inches in width, or 16% of the wall thickness. Figure 5 shows the cross section of the crack, which is approximately 90 around the circumference of the tube. Compiling historical primary containment breaches, the conservative assumption Micro Motion uses in this model is that the crack width is 40% of the wall thickness and length of the crack goes 180 around the circumference of the tube. Appendix B: Reference Documents Crane Technical Bulletin 410 API RP 520 API RP 521 Figure 4: Tube crack Figure 5: Crack cross section 0.04 inches Written by Tony Pankratz Director, Sensor Technology Emerson Automation Solutions 7070 Winchester Circle Boulder, CO USA 80301 T +1 303 527 6277 F +1 303 530 8459 www.emerson.com 2018 Micro Motion, Inc. All rights reserved.