Measuring Flow with. Centre County PaSEC. QC Team July P a g e

Similar documents
CCPaSEC. Procedure for the Quality Control Yearly Equipment Check. July 2018 CCPaSEC Quality Control Team

#LZ400 LEAKALYZER. Water Loss Sensor INSTRUCTION MANUAL Country Dr. #190 St. Paul, MN

reported in stream flow.

The Crease Matic 150 is quiet in operation and the drive motor shuts down if not used for a period of time.

Pocket Weather Meter INSTRUCTION MANUAL. with Backlight

TOP:001.3 U.S. Fish and Wildlife Service TECHNICAL OPERATING PROCEDURE

SS32L Dissolved O 2 Probe

Experiment #2. Density and Measurements

TRAINING LAB BLOOD AS EVIDENCE BLOOD DROPS FALLING AT AN ANGLE NAME

YSI Model 550a Dissolved Oxygen (DO) Meter

Experiment C-6 Gas Solubility

GEOL 106: Earthquake Country Activity 08: Discharge Measurements. Name: Date:

Duplex Commercial Softeners

WASHINGTON CONSERVATION DISTRICT STANDARD OPERATING PROCEDURE (S.O.P.)

Evaluation copy. Interdependence of Plants and Animals. computer OBJECTIVES MATERIALS

Presents the following instructional slide show:

reported in flow for stream flow.

Model 130M Pneumatic Controller

Paper #: POWER

Kestrel 5700 Elite. App Quick Start Guide

Commercial Softeners. Installation, Operation & Maintenance Guide. Manual 002.1

Observing Waves, Their Properties, and Relationships

Biology Unit 2, Structure of Life, Lab Activity 2-3

FIELD PROCEDURE: FLOW

Survey Technical Support Notes October 2015

Land Survey. 1. Pick the two points (A and B) that you would like to measure. You must be able to see clearly between the two points.

STATION 1: HOT WHEELIN PHYSICS 1. Define Newton s First Law. 2. Describe the motion of the untaped washer when the car hits the pencils.

Relative Humidity Calibration Kit

Special Olympics Junior Athletes. Floorball

Water Quality Monitoring Using a Handheld Sonde for in situ Measurements Date Prepared: 11/17/2017

The Oxygen Sensor can be connected to all types of einstein Tablets, einstein LabMate, and einstein LabMate +.

Gravity: How fast do objects fall? Teacher Version (Grade level: 4 7)

(Lab Interface BLM) Acceleration

High Pressure Chem-SCAN Operating Manual

Technique Sheet 16. Using the Metric Ruler

SHOT PUT - GLIDE TECHNIQUE

Exploring the Properties of Gases

Measurements. Metric System

Sontek RiverSurveyor Test Plan Prepared by David S. Mueller, OSW February 20, 2004

Instructions for Assembly, Installation, and Operation of the Gas Addition Kit Accessory with the CEM Discover Systems

ISE-730 Oxygen Electrode and DO2-100 Currentto-Voltage

1. Open Stick Block Tackle: Tackle Box. 2. Open Stick Block Tackle: Letters and Numbers

FLOW MEASUREMENT (SEMI-SUBMERGIBLE OBJECT METHOD)

Three Lakes Association Hydrolab for Dummies. Table of Contents:

Lab 1: Pressure and surface tension. Bubblers, gravity and the mighty paper clip.

Optical Dissolved Oxygen Meter

Experiment 11: The Ideal Gas Law

Scholarship 2018 Earth and Space Science

ACQUIDATA FAMILY CALIBRATION PROCEDURE CALIBRATION CHECKING

Slide 1 - Welcome to an Overview of the Student Center and New Titan Online

River Study Fieldwork Sheets

UsER manual for Watersens ph -REDOX

CONSUMER MODEL INSTALLATION GUIDE

ACV-10 Automatic Control Valve

Optical Dissolved Oxygen Meter

Flow Rate Sensor Product Number: ENFLO-A254A

Sampling Equipment Catalog. MicroPurge Low-Flow Pump Control

PR4 Installation, Operation & Maintenance Instructions (DOT Certification Included)

Refillable ORP/Redox Probe: Model MTC30101 or MTC30103

Copyright Velocomp LLP 2006

Potential and Kinetic Energy: The Roller Coaster Lab Student Version

Finally Out of the Sand

Outdoor Station 1. K-5 Water Balloons. Station Description

Dissolved Oxygen/Temp Waterproof Tester

Equipment Standard Operating Procedure Greg Allion and Kimberly Appel

FUNdamentals Pratice Plans

Pass. Tackle. Year 2. Save. Hockey. Goal. Turn. Shoot

Fix Your Swing Series. Table of Contents

BC Ministry of Forests. March Fish Stream Crossing Guidebook. Forest Practices Code of British Columbia.

Relevent SOL s. Materials and Resources:

Coaching Principles. 1. Introduce 2. Demonstrate 3. Explain 4. Organize 5. Execute 6. Correct 7. Practice

The Discus. By Al Fereshetian. Nature of the Event

TrackMan Operator Training

Bante821 Portable Dissolved Oxygen Meter Instruction Manual

Measuring the Conductivity of Pure Water Using USP<645>

How Fast Is Your Toy Car?

Discus Technique: Basic Technique A Technical Analysis Grip Fork Gr Purpose: To provide control over Discus is held with Discus is held

Earthworks X200 Quick Reference Guide

Trampoline & Enclosure Assembly Instructions

Trampoline & Enclosure Assembly Instructions

Pegas 4000 MF Gas Mixer InstructionManual Columbus Instruments

ESCONDIDO FIRE DEPT TRAINING MANUAL Section Truck Module Page 5 of 14 Water Rescue Procedures Revised

INSTALLATION & START-UP INSTRUCTIONS FLECK 9100SXT METER TWIN ALTERNATING WATER SOFTENER SYSTEMS

icreasepro Creaser Operators Manual

LAB : Using A Spark Timer

Adrift A Classroom Activity for Ocean Gazing Episode 18: The princeʼs predictions: Part II

Rocket Activity Foam Rocket

Quick Guide. SGX-CA500 Cycle Computer SGY-PM Series Power Meters

Figure 4, Photo mosaic taken on February 14 about an hour before sunset near low tide.

TRAVELLERS SPORTS SWIMMING COACHING MANUAL

Culvert Design for Low and High Gradient Streams in the Midwest. Dale Higgins, Hydrologist Chequamegon-Nicolet National Forest

LABORATORY INVESTIGATION

How to Measure R7.1. Reference. I. Linear dimensions

Exploring the Properties of Gases. Evaluation copy. 10 cm in diameter and 25 cm high)

Experiment P18: Buoyant Force (Force Sensor)

! USPPA PPG1 Written Test Revised 2/23/ Formating & Clarity

Low-Flow Purging Procedure with MicroPurge basics Equipment. MP10 Bladder Pump Controller MP15 Control. MP30 Drawdown Meter.

Unit 7: Waves and Sound

ADVANCED PORTABLE LAUNCH MONITOR. ES14 User Manual

SERVICE INSTRUCTIONS

Transcription:

Measuring Flow with Centre County PaSEC QC Team July 2018 1 P a g e

Safety Considerations We are responsible for our own safety, but we also need to be ready to assist our teammates. Safety measures and unique team issues are to be discussed annually among all volunteers. Teams should let someone else know when you intend to return, know your site location, and what to do if you do not return on time. Teams of three or more are preferred. No one should perform sampling alone. Only one person need enter the water to collect samples or perform flow measurements using the FloWatch meter. A partner must be present and remain on shore. The decision on going into the water should be made by someone who is not going in so that pride and ego are not part of the decision. Risk/benefit analysis = data not worth the risk! Don ts: We should not sample if severe weather is predicted, Listen to weather reports. STOP the process if a storm occurs while at the sampling location. Avoid Sampling if there are small creek flood warnings or advisories. Do not enter the water or collect a sample if the stream site is posted as unsafe for personal contact. Winter adds extra safety concerns with ice and snow that reduce footing and with cold air and water temperatures that reduce physical capabilities. Avoid wading in swift or high water. Do not wade if depth is greater than knee-deep. Avoid unstable stream banks. Disturbing these banks, including the vegetation growing upon them, can accelerate erosion and lead to a collapse. Do s: Entering the stream: We recommend you use a walking stick or staff to steady yourself. One of the consequences of using the flow meter with no separate stabilizing pole may result in using the flow meter shaft to reach stabilization which would lead to damage to the flow meter. A partner must be present and remain on shore. We suggest that people who enter the water leave their important items like wallet, keys, etc. in a safe place. To avoid having to enter the stream we recommend that teams rinse and scoop a water sample using a bottle or beaker with a long handled dipper and to perform the ph, conductivity, TDS, Salinity tests on shore. NOTE: We need to clean foot ware to help prevent cross contamination of sites from the New Zealand mud snails. Some hip boots that have felt soles, intended to improve stability, may to be more prone to capture and transport the snails. Some states have band them. 2 P a g e

Setting up the meter Assemble the SMALL turbine onto the wand. Do not push it on by the blue housing. Hold it by the black tube and pull it onto the wand. It must be fully seated as shown in the illustration or the meter will not record velocity. Please do not remove it. Keep it installed on wand. The larger propeller may be used for very low velocities and is assembled in the same way. Test the operation of the meter by gently blowing on the turbine or gently swing it in the air. The turbine should spin freely. If not, try sliding the metal guard ring back and forth inside the blue housing. 3 P a g e

Recommended Setup Press and hold this button to turn the meter on. Press it again momentarily if you want to turn on the axillary light. Press and hold it to turn the meter off. Average speed (at the center if AV is selected) Press the setup button momentarily. To scroll through the available functions, press the setup button again to select the function you want to change. A bar will flash to indicate which function you may select. Use the up/down arrows to select the units for the function then press the setup button to save that selection. NOTE: If you did not change the setting, the setup button will shift to the next function. After you have stepped through all the functions the meter will return to the normal operations The meter will return to normal mod several seconds after no buttons have been pushed. 1) Press this button momentarily to turn the meter ON. 3) Press the up/down arrows to select the units for the setting. 2) Press this button to enter the settings mode. Pressing the button again will step you through the settings and will cause the system to confirm a new setting if there has been a change. If not, then it goes to the next setting. As you step through the settings a bar will flash to indicate which setting you selected. Set the meter to AVERAGE (AV). Set the flow to cm/sec. as indicated on the display. Set the temperature units to degrees centigrade Set the average period to 6 seconds as shown. 4 P a g e

Determining Flow Determining flow is limited by the equipment available to us and in some degree depend on our procedure and the site selection. The flow meter improved accuracy and volunteer safety over the float method because it reduced the number of measurements needed and provides automatic averaging of the velocity. With it, the time the volunteer is in the stream is shortened and only one person need enter the water. It is important that we be consistent in the application of the method and location we use at the stream site so that we can monitor seasonal changes. NOTE: We also need to recognize the need to clean foot ware to help prevent cross contamination of sites from the New Zealand mud snails. Some hip boots that have felt soles, intended to improve stability, may be more prone to capture and transport the snails. Some states have band them. Choose a location reasonably free of large rocks or obstructions, with a relatively flat streambed, away from the influence of abrupt changes in channel width or depth and free of stream side back eddies. Select location Example location to measure Flow: Lick Run 5 P a g e

Procedure: Flow in a Small Stream Establish a cross-section Determine the width of the stream using a measuring tape at a right-angle to the flow. Divide the width into approximately equal Intervals. Five minimum, ten or more Intervals are recommended, up to 20 are accommodated by our flow calculator. Adjust the lanyard so that the tape measure end is over the edge of the stream. Recommended Units of measure Width: measurements in meters (m). See tables on pages 11 and 12 for suggested spacing. Depth: measurements in centimeters (cm). Velocity: Measure the average velocity at approximately 60% of the stream depth in cm/sec. 6 P a g e

Velocity as a Function of Width & Depth. The velocity of moving water varies both with the width of a stream channel and from the surface to the bottom of the stream. Irregularities slows the water near the bottom and sides of a channel so that the fastest water is usually near the center of the channel and near the surface. We measure the average velocity at about 60% of the depth from the surface to determine the average. Depth Choosing how many intervals The stream widths may vary greatly during the year and the topology of the stream bed may force a major portion of the flow into a narrow zone. In those situations, it may be useful to change the number of intervals to either simplify the process in the case of a very narrow stream or to capture an unusual narrow flow zone. The proper way to include a narrow zone is to adjust the number of intervals to capture that zone. If you find it necessary to choose a different number of intervals (say 6 or 15 up to 7 P a g e

20) you still need to locate your intervals evenly across the stream width so that we calculate a proper average rate of flow (The calculator determines the AREA of each cell by dividing the width by the number of intervals). Online Flow Calculator Our flow calculator includes an option for the number of intervals or cells included in the sampling for up to 20 locations. We recommend using 10 and not to use less than 5 but you may use any number up to 20. Use the latest CCPaSEC field data sheet available on our WEB site: Water Monitoring Site Physical and Chemical. Use the latest CCPaSEC field data sheet available on our WEB site: Water Monitoring Site Physical and Chemical 3/26//2016 p. 2. Go to the CCPaSEC WEB site for the online flow calculator. Note: the velocity must be in units of cm/sec. and ENTER DATA in the yellow cells. As you enter the depth readings you will see the profile chart develop. You may enter data for up to 20 Intervals. The calculator will calculate the flow as you enter the data. 8 P a g e

Clear all previous entries before starting another calculation by first clicking on one entry and then pressing the Delete key. This process must be repeated for each entry in both lines of data. Please print, record or download your results, then: Press the Refresh/Reload icon on your browser tool bar to clear all entries for the next calculation. Common Calculator Issues Be sure you used the correct units you used to record velocity (cm/sec), width (Meters) and depth (centimeters). Clear all previous entries before starting another calculation. The calculator must have an entry for the stream width. It uses that number to determine the area of each Interval cell. Check that you ve entered the data correctly with the proper decimals. Please print, record or download your results, then: Press the Refresh/Reload icon on your browser tool bar to clear all entries for the next calculation 9 P a g e

The calculator The calculator uses our depth measurements, stream width to define the approximate size, number and the area of individual cells very similar to the method used by Professionals. The area of each cell is approximated by dividing the stream width measurement (meters) by the number of depth measurements (intervals) you used and multiplied by the depth (converted to meters) at that interval. The calculator logic lets you use any number of intervals up to 20. The flow for each cell is determined by multiplying the area of that cell times the average velocity you entered for that cell location (converted to meters per second). The calculator sums the results of the averaged cell flows to provide the total flow in cubic meters/second. 10 P a g e

Calibrating the meter You need to provide an alternating magnetic field to calibrate the FloWatch. This can be done by holding probe close to a small motor running at 60 Hz single phase. Turn the FloWatch on. Hold the probe near the motor to pickup a reading. It should read 205 cm/sec. If not, it will need recalibration. Probe 1. Turn meter on. 2. Press both bottom buttons simultaneously. A count down will start on the screen. 3. Before the countdown ends release the bottom left button (do not release the bottom right) and press the top right button. 4. Release both buttons and use the arrows to set the value on the screen to 123. 5. The meter will return to normal mod several seconds after no buttons have been pushed. Step 1. Turn the meter on by momentarily pressing this button. Step 2. To calibrate the meter, press and hold these two buttons simultaneously. Step 3. A countdown begins to clear the memory. Keep pressing the right button and release the left setup button before it stops. Step 4. While still pressing the lower right button - press the top right button to enter the calibration mode. The screen should show 123 If not. Adjust the number with the up/down arrows (buttons). 11 P a g e

12 P a g e

13 P a g e

Chemical Data Recording Sheet table for Flow 3/26//2016 p. 2 Centre County Senior Environmental Corps Water Monitoring Site Physical & 14 P a g e