ST30 Round Bidata Owner s Handbook

Similar documents
TOP BLEED Position for SeaTalk 2 colour logo ST 30. COMPASS Operation and Installation

ST40 Bidata Instrument Owner s Handbook. Document number: Date: March 2006

ST60 Depth Instrument Owner s Handbook. Document number: Date: 1 April 2004

ST60+ Depth Instrument Owner s Handbook

INTRODUCTION TO NETWORK WIND 3 MOUNTING THE UNIT 14 SELECTING THE DISPLAY MODE 5 ABBREVIATIONS AND DEFINITIONS 17

INSTALLING THE ECHO SOUNDER TRANSDUCER CHANGING THE OPERATING CONFIGURATION

SP-110 Autopilot OPERATION

USER GUIDE FOR DATALINE-X SDX. Stowe Marine Ltd. Tel +44(0)

Copyright 2004 by the Thomas G. Faria Corporation, Uncasville CT No part of this publication may by reproduced in any form, in an electronic

S100 Controller. User guide. English Date: Document number: EN 2006 Raymarine UK Limited

CLIPPER DEPTH METRES ENTER SHALL DEEP ILLUM CLIPPER ECHO SOUNDER

ECHO MANUAL WARNING. L B A ltim e te rs. ECHO is a trademark of LB Altimeters, Denmark

Portable Gas Monitor GX User Maintenance Manual (H4-0050)

PLAQUE MFM0680 UNDERWATER LIGHT. Operating Instructions

Steer to Wind angle, Wind Mode, when connected to the h1000 Wind Interface

ST70 Autopilot Controller User Reference Guide

Horizon Strike 200/220s

S1000+ / S2000+ Tiller Pilots

INSTALLATION AND USER INSTRUCTIONS for TARGET 2 LOG, DEPTH & WIND MARINE INSTRUMENTS

mn100 Analog Display

ST1000 Plus & ST2000 Plus Tiller Pilots Owner s Handbook. Document number: Date: June 2001

CLIPPER DUET M P H DEPTH F E E T SPEED TOTAL TRIP ILLUM. Duet COMBINED LOG AND ECHO SOUNDER

ST5000+ Sterndrive & Hydraulic Autopilots. Owner s handbook. English Date: Document number: EN 2006 Raymarine UK Limited

Getting to know your Sureshotgps micro V3

DESIGNED AND MANUFACTURED IN ENGLAND CLIPPER DEPTH DEPTH METRES ECHO SOUNDER.

Software updates Check the website for the latest software releases for your product.

WIND. - Instrument - Installation and Operation Manual English

WlND & CLOSE HAULED/WIG Operation and installation. .i f :ia. c Ir -

PLAQUE MFM18240 UNDERWATER LIGHT. Operating Instructions

RAM 4021 Operation Manual

MP15 Jockey Pump Controller

PULSAR 5000 SERIES OPERATING & INSTALLATION INSTRUCTIONS SERIES 5000 PLEASE READ CAREFULLY BEFORE INSTALLING

User s Guide Temperature Sensor Converter TSC-599

S1000+ / S2000+ Tiller Pilots. Owner s manual

SmartPilot X5 Sport Installation & Setup Guide

Calibration Gas Instrument INSTRUCTION MANUAL. Release I. Advanced Calibration Designs, Inc.

CONUS MSR0680 UNDERWATER LIGHT. Registered Community Design. Operating Instructions

URC Voltage Sensor SEN-VOLT for use with MRX units containing sensor ports

PART 5 - OPTIONS CONTENTS 5.1 SYSTEM EXPANSION 5-3

RAM Operation Manual. Worldwide Manufacturer of Gas Detection Solutions

METEOR LSR36500 LIGHTING UNDERWATER POOL LIGHT. Operating Instructions

T i m i n g S y s t e m s. RACEAMERICA, Inc. P.O. Box 3469 Santa Clara, CA (408)

DIVER NAVIGATION BOARD. RJE International, Inc. RJE International Feb 1, TAC-100D Revision 10

SPECIFICATIONS APCEPH1

ST7001 Smartpilot Controller Operating Guide

GasSense NDIR User Manual

81270_1.book Page i Wednesday, November 9, :33 PM. ST7002 SmartPilot Controller Operating Guide

PIRANHA I & 2 OPERATION GUIDE

RAM 4021-PR. Operation Manual. Worldwide Manufacturer of Gas Detection Solutions

Parts and Owners Manual

Manual Leveling Control Installation/Operation

COMBAT SWIM BOARD. RJE International, Inc. RJE International January 16, TAC-300 Revision 4

This document to be used with Hurley traditional Davits

RAM Operation Manual. Worldwide Manufacturer of Gas Detection Solutions

Simple, Robust, Reliable Measures ph Doses either acid (lower) or alkali (raise) Displays ph, Total Dose Count (DCT) and Dose Count per hour (DC/h)

DISASSEMBLING & REASSEMBLING CARTRIDGE INSTALLING SEATPOST ON BIKE

SIX R (P ) AND SEVEN R (P ) POSITION CYLINDERS Service Information

RAM 4021-DPX Operation Manual

Do not install and/or operate this safety product unless you have read and understand the safety information contained in this manual.

Digital Melting Point Apparatus

OPERATION AND INSTALLATION MANUAL

PRODUCT SUPPORT MANUAL YACHT BEAM 6M Searchlight Remote Control System with Joystick Remote Control Panel

2 GALLON TWIN STACK AIR COMPRESSOR W/ HOSE REEL

Installation Instructions Air Compressor Part # 2780, 2781

ST600R Autopilot Control Unit Owner s Handbook. Document number: Date: May 2001

COMBAT SWIM BOARD. RJE International, Inc. RJE International Feb 1, TAC-300 Revision 6

Model 6812C Dual Lane Scoreboard Owner s Manual

User's Manual. Heavy Duty Dissolved Oxygen Meter. Model

MODEL 100 NITROGEN INFLATION CART

SmartPilot X5 Sport Operating Guide

GEMS SENSORS & CONTROLS

L230 LED 40 Watt Searchlight

FLANGED TWO-PIECE BALL VALVES

Sterile Visual Flow Indicator

D10S/D20S Wall/Post Mount Inflator Quick Start Manual

PILOT PEDAL DRIVE INSTRUCTIONS

E2K-L. Liquid Level Sensor That Is Unaffected by the Color of the Pipe or Liquid. Liquid Level Sensor. Ordering Information

6 digital caliper with case

Digital Inflation Equipment

INSTALLATION. and INSTRUCTION MANUAL. for QUALITY AIR BREATHING SYSTEMS. Model 50-P-Mini Portable Systems Outfitted with ABM-725 Monitor

DEEPSEA. Power & Light. Micro SeaLaser. Operator s Manual Ruffin Road San Diego, CA USA T: (858) F: (858)

Foldable Magne c Exercise Bike

The Univentor 1250 Anaesthesia Unit

EMC Conformance. Important

FLANGED TWO-PIECE BALL VALVES

Digital Vacuum Regulator

VISO Manual. LARSEN & BRUSGAARD Mosevej Kirke Hyllinge, Denmark Phone: Fax:

PERSONAL AIR BREATHING UNIT

CONTENTS STEER TO VANE MODE...

RAM Operation Manual

81131_8.book Page i Thursday, October 7, :03 AM. ST4000+ Wheel & Tiller Autopilots Owner s Handbook

Digital Inflation Equipment 89XDA 89XDD 89XDB 89XDE.

NB/NBR NITROGEN BOOSTER FOR AVIATION SERVICE

OPERATOR'S MANUAL GRASS CATCHER GC-4D

OPERATOR'S MANUAL. MODEL GC-F4 Fabric Grass Catcher P/N 9055 GRASS CATCHER GC-F4. PART Rev.2 SC301G

HAI UPB 15A Relay Switch and Auxiliary Switch Installation and Operating Instructions

TOP VALVE. Pat. #5,857,486 & 5,944,050. Mid-Range Pressure PSIG Back Pressure and Pressure Relief Valves. Instruction Manual

MODEL NUMBER: P PORTABLE COMPRESSOR

Operation Manual. Pro CO 2 Analyzer. Carbon Dioxide Analyzer. Rev

Wireless Belt Pack BP Conductor with Radio Transmit

Transcription:

ST30 Round Bidata Owner s Handbook Document number: 81075_4 Date: 1st April 2001

Copyright Raymarine Limited 2001

Preface i Important information WARNING Although your ST30 instrument is designed to give accurate and reliable performance, it should serve only as an aid to navigation and should never lead to the erosion of good seamanship. Always maintain a permanent watch and be aware of situations as they develop. EMC conformance All Raymarine equipment and accessories are designed to the best industry standards for use in the leisure marine environment. The design and manufacture of Raymarine equipment and accessories conform to the appropriate Electromagnetic Compatibility (EMC) standards, but correct installation is required to ensure that performance is not compromised. Handbook information To the best of our knowledge, the information in this handbook was correct when it went to press. However, the Raymarine policy of continuous product improvement may change product specifications without notice. Consequently, unavoidable differences may occur between the product and the handbook from time to time, for which Raymarine cannot accept liability.

ii ST30 Round Bidata Owner s Handbook

Preface iii Contents Important information... i WARNING... i EMC conformance... i Handbook information... i Preface... vii Parts supplied... viii Chapter 1: Operation... 1 1.1 Introduction... 1 1.2 Depth key functions... 2 Water depth... 2 Shallow alarm... 2 Adjusting shallow depth... 2 Silencing the shallow alarms... 3 Turning shallow alarm ON and OFF... 3 Offset... 3 Default display... 3 Loss of signal... 3 1.3 Speed key functions... 4 Speed... 4 Trip distance... 4 Resetting Trip Distance... 4 Ships log... 4 1.4 LCD illumination... 5 Chapter 2: Maintenance and Fault Finding... 7 2.1 Maintenance... 7 Servicing and safety... 7 Cleaning the instrument... 7

iv ST30 Round Bidata Owner s Handbook Condensation... 7 Cables... 8 2.2 Fault finding... 8 Chapter 3: Installation... 9 3.1 Introduction... 9 EMC installation guidelines... 9 Suppression ferrites... 10 Connections to Other Equipment... 10 3.2 Installing the instrument... 10 3.3 Connecting the power supply direct... 12 3.4 Power via SeaTalk... 13 3.5 Adding an independent lighting switch... 13 3.6 Installing the Biducer transducer... 14 Cable connections... 14 3.7 Calibration requirement... 14 Chapter 4: Calibration... 15 4.1 Introduction... 15 EMC conformance... 15 4.2 Basic calibration... 15 Offset entry... 16 Depth units... 17 Speed and log units... 17 Log calibration... 17 Procedure... 18 Exiting basic calibration... 18 4.2 Intermediate calibration... 18 Software version... 19 Repeater... 19 Saving intermediate calibration... 19

Preface v Exit intermediate calibration without saving... 19 Default display... 20 4.3 Extended calibration... 20 Calibration... 21 Boat show... 21 Depth and speed damping... 21 Saving extended calibration... 21 Exit extended calibration without saving... 21 Specification... 23

vi ST30 Round Bidata Owner s Handbook

Preface vii Preface Thank you for purchasing a Raymarine product. We are sure your ST30 instrument will give you many years of trouble-free operation. This instrument is designed to provide reliable performance, even under the most demanding conditions. depth bidata speed depth speed D1601-2

viii ST30 Round Bidata Owner s Handbook Parts supplied depth bidata speed depth speed ST30 Round Bidata instrument Sealing gasket Display bezel (1 black & 1 grey supplied) SeaTalk 2 m (6.5 ft) power cable Fixing studs (x2) Thumb nuts (x2) SeaTalk SeaTalk Interconnection cable "C" bracket Biducer ST30 Round Bidata Owner's Handbook Worldwide Distributors Owner's Handbook Warranty document and fitting template included in Handbook Worldwide Service Centre Handbook Cue Card Notes: The items shown are supplied for an ST30 Round Bidata system. If an instrument is purchased separately, a transducer is not included. If any item is not present, contact your Raymarine Dealer. If the ST30 Round Bitata is to be flush mounted, do not fit a display bezel. D1603-3

Chapter 1: Operation 1 Chapter 1: Operation 1.1 Introduction The ST30 Round Bidata instrument is designed for the powerboat market, and displays speed and depth information simultaneously on a split LCD. The Bidata can also display trip and log distances, sound a user-defined shallow alarm, and function as a repeater. The instrument can be surface or flush mounted and fits the standard 85.7 mm (3 3 / 8 inch) diameter facia apertures, common on many sports boats. The Bidata uses an easy-to-install transom mount transducer (Biducer) combining both speed and depth elements in a single housing. If the Bidata is used in conjunction with a SeaTalk autopilot, the speed input provided by the instrument enhances the pilot's steering performance. depth bidata speed depth speed The operating procedures are presented as a combination of flow charts and text. Unless otherwise stated, the illustrated key presses are momentary. The Bidata can display depth and speed information in metric and imperial units. These are set during basic calibration (see Chapter 4, Calibration). D1601-2

2 ST30 Round Bidata Owner s Handbook 1.2 Depth key functions The following flow chart shows the depth key functions. depth bidata speed depth speed WATER DEPTH SHALLOW ALARM OFFSET D1763-2 Water depth Depth is displayed in feet (0 to 400 ft) or metres (0 to 120 m). Shallow alarm The shallow alarm displays the depth (feet or metres) at which point audible and visual alarms will be triggered. These alarms can be silenced by pressing the speed or depth key. Adjusting shallow depth 1. From the shallow depth alarm display, press depth and speed together momentarily to display CAL. 2. Press depth and speed together again momentarily to enter edit mode (+ and - displayed). 3. Press depth to increase and speed to reduce the displayed value. 4. Press and hold depth and speed together for 2 seconds, to exit edit mode and save the new value.

Chapter 1: Operation 3 Offset Silencing the shallow alarms Press speed or depth to silence the audible alarm for a period of two minutes. If, after 2 minutes, the water depth is still below the alarm setting, the alarm will be activated again. Note: When the audible alarm is silenced the alarm icon continues to flash. Turning shallow alarm ON and OFF 1. Ensure the shallow alarm screen is displayed. 2. Press depth and speed together momentarily to enter CAL mode. 3. Press depth to switch the alarm ON or OFF. 4. Press depth and speed together for 2 seconds to exit CAL mode. This is the distance (feet or metres) from the Biducer to the bottom of the hull or to the waterline, which can be a positive (+) or negative (-) value. Default display The depth display will always default back to water depth 8 seconds after the last key press. Loss of signal If there are no depth echoes for 10 seconds, the feet/metres legend flashes and the last recorded depth is displayed until a new echo is received.

4 ST30 Round Bidata Owner s Handbook 1.3 Speed key functions The following flow chart shows the speed key functions. depth bidata speed depth speed SPEED TRIP LOG D1764-2 Speed The speed display can be either knots (Kts), miles per hour (Mph), or kilometres per hour (Kph). Trip distance Ships log Trip is the distance covered between power on and power off. This can be nautical miles (NM), kilometres (KM), or statute miles (SM). Resetting Trip Distance Press and hold the speed key until the trip distance is zeroed - distance flashes after 1 second and during the resetting process. When this value exceeds 999 NM, SM, or KM, the Bidata displays the log as thousands (th) and, after 3 seconds, hundreds, tens, and units. For example, 1525 nm would be displayed as 1th then 525.

Chapter 1: Operation 5 1.4 LCD illumination depth bidata speed depth speed 1 second High (L3) Medium (L2) Low (L1) OFF (L0) D1765-2 The Bidata has four illumination settings, off, low (L1), medium (L2), and high (L3). The Bidata automatically returns to normal operation 5 seconds after the last key press. If the shallow depth alarm is activated the illumination display is ignored.

6 ST30 Round Bidata Owner s Handbook

Chapter 2: Maintenance and Faultfinding 7 Chapter 2: Maintenance and Fault Finding 2.1 Maintenance Servicing and safety Raymarine equipment should be serviced only by authorised Raymarine service technicians. They will ensure that service procedures and replacement parts used will not affect performance. There are no user serviceable parts in any Raymarine product. Some products generate high voltages, so never handle the cables/ connectors when power is being supplied to the equipment. When powered up, all electrical equipment produces electromagnetic fields. These can cause adjacent pieces of electrical equipment to interact with one another, with a consequent adverse effect on operation. In order to minimise these effects and enable you to get the best possible performance from your Raymarine equipment, guidelines are given in the installation instructions, to enable you to ensure minimum interaction between different items of equipment, i.e. ensure optimum Electromagnetic Compatibility (EMC). Always report any EMC-related problem to your nearest Raymarine dealer. We use such information to improve our quality standards. In some installations, it may not be possible to prevent the equipment from being affected by external influences. In general this will not damage the equipment but it can lead to spurious resetting action, or momentarily may result in faulty operation. Cleaning the instrument Periodically clean the instrument should be cleaned with a soft, damp cloth. Do NOT use chemical or abrasive materials. Condensation Certain atmospheric conditions may cause a small amount of condensation to form on the instrument window. This will not harm the instrument and will clear after the instrument has been switched on for a short period.

8 ST30 Round Bidata Owner s Handbook Cables 2.2 Fault finding Periodically examine the SeaTalk, Biducer, and power cables for evidence of damage to the outer shield, and if necessary, replace with genuine Raymarine cables. If you appear to have a problem with your Bidata unit, please refer to this table before contacting your Raymarine Dealer. Fault Display blank No speed information No depth information Speed/log information inaccurate Action Poor power cable connection or cable damaged. Check the circuit breaker/fuse. Biducer paddlewheel obstructed. Poor Biducer cable connection or cable damaged. Aerated water, boat wakes or propeller wash. Normal operation will return once you are clear of the disturbed water. Poor Biducer cable connection or cable damaged. Log calibration has not been carried out (see Chapter 4). Unable to enter basic Calibration is set to off (see Chapter 4). and intermediate calibration Feet/metres display flashes. continuously Poor Biducer cable connection or cable damaged.

Chapter 3: Installation 9 Chapter 3: Installation 3.1 Introduction Please read this chapter thoroughly before attempting to install the instrument and transducer. Always use genuine Raymarine cables. The use of unapproved/inferior cables, for which Raymarine cannot be held liable, could affect the performance of the Bidata and other instruments on the SeaTalk bus. The Bidata may be flush mounted by installing the instrument from behind the instrument panel. The display bezel must not be assembled to the instrument if the Bidata is to be flush mounted. EMC installation guidelines All Raymarine equipment and accessories are designed to the best industry standards for use in the leisure marine environment. Their design and manufacture conforms to the appropriate Electromagnetic Compatibility (EMC) standards, but correct installation is required to ensure that performance is not compromised. Although every effort has been taken to ensure that they will perform under all conditions, it is important to understand what factors could affect the operation of the product. The guidelines given here describe the conditions for optimum EMC performance, but it is recognised that it may not be possible to meet all of these conditions in all situations. To ensure the best possible conditions for EMC performance within the constraints imposed by any location, always ensure the maximum separation possible between different items of electrical equipment. For optimum EMC performance, it is recommended that wherever possible: Raymarine equipment and cables connected to it are: At least 1 m (3 ft) from any equipment transmitting or cables carrying radio signals e.g. VHF radios, cables and antennas. In the case of SSB radios, the distance should be increased to 2 m (7 ft). More than 2 m (7 ft) from the path of a radar beam. A radar beam can normally be assumed to spread 20 degrees above and below the radiating element.

10 ST30 Round Bidata Owner s Handbook The equipment is supplied from a separate battery from that used for engine start. Voltage drops below 10 V in the power supply to our products, and starter motor transients, can cause the equipment to reset. This will not damage the equipment, but may cause the loss of some information and may change the operating mode. Raymarine specified cables are used at all times. Cutting and rejoining these cables can compromise EMC performance and so must be avoided unless doing so is detailed in the installation manual. If a suppression ferrite is attached to a cable, this ferrite should not be removed. If the ferrite needs to be removed during installation it must be reassembled in the same position. Suppression ferrites The following illustration shows typical cable suppression ferrites fitted to Raymarine equipment. Always use the ferrites supplied by Raymarine. D3548-2 Connections to Other Equipment If your Raymarine equipment is to be connected to other equipment using a cable not supplied by Raymarine, a suppression ferrite MUST always be fitted to the cable close to the Raymarine unit. 3.2 Installing the instrument When selecting a location for the Bidata instrument, ensure that: It is at least 230 mm (9 in) from a compass It is at least 500 mm (20 in) from radio receiving equipment There is sufficient clearance behind the bulkhead to house the rear of the instrument, fixing studs, C bracket, and SeaTalk cables.

Chapter 3: Installation 11 bidata depth speed depth speed 84.4 mm (3.32 in) 94.15 mm (3.7 in) 17 mm (0.67 in) 89.1 mm (3.5 in) 94.15 mm (3.7 in) 37.5 mm (1.47 in) 54.5 mm (2.15 in) D1598-2 CAUTION Where it is necessary to cut holes (e.g. for cable routing and instrument mounting), ensure that these will not cause a hazard by weakening critical parts of the vessel s structure. If in doubt, seek advice from a reputable boat builder. 1. If appropriate, use the template provided near the back of this book to mark the intended location of the Bidata instrument. 2. Use a tank cutter to machine an 85 mm (3 3 / 8 in) clearance hole for the instrument. Note: If you do not wish to use a tank cutter, the hole can be machined using a hole saw and a file. D1599-2 2. Remove any burrs from the aperture.

speed 12 ST30 Round Bidata Owner s Handbook 3. Pass the SeaTalk and transducer cables through the seal. Plug these cables into appropriate instrument ports. 4. Secure the instrument using the fixing studs, C bracket, and thumb nuts as shown. depth bidata depth speed D1600-2 3.3 Connecting the power supply direct CAUTION Ensure that the power supply is protected by a 5 A fuse or circuit breaker. 1. Plug the 2 m (6 ft) power cable into one of the SeaTalk ports. 2. Connect the red wire to 12 V (+) and the screen to 0 V (-). Protect the circuit with a 5 A fuse/circuit breaker. D1602-2

Chapter 3: Installation 13 3.4 Power via SeaTalk CAUTION Ensure that the power supply is protected by a 5 A fuse or circuit breaker. If the Bidata is to be used with other SeaTalk instruments, the power supply is passed from instrument to instrument via the daisy loom cable as shown. 3.5 Adding an independent lighting switch When the Bidata is part of a SeaTalk system the lighting is controlled from the keypad or from another SeaTalk instrument on the bus. If you have an independent lighting switch, this can be connected to the terminal so that the Bidata lighting can be switched with your existing equipment. 1 2 +12V 1 Power cable 2 Lamp connection to instrument panel D1744-2

14 ST30 Round Bidata Owner s Handbook 3.6 Installing the Biducer transducer The ST30 Round Bidata is supplied with a combined speed and depth transducer (Biducer). This should be installed in accordance with the instructions provided. Cable connections The cable from the Biducer consists of five cores which should be connected to the Bidata as follows: Cable colour Green Screen Red Blue Black Bidata connection Green SPEED Grey SPEED Red SPEED Blue DEPTH Black DEPTH 3.7 Calibration requirement Once installation is complete and before you use your instrument, carry out the calibration procedures detailed in Chapter 4, Calibration.

Chapter 4: Calibration 15 Chapter 4: Calibration 4.1 Introduction This chapter describes how to set and adjust features contained in the basic, intermediate, and extended calibration menus. The calibration procedures must be carried out before the equipment is used operationally, to optimise the performance of the instrument with the vessel. All key presses are momentary unless otherwise stated. EMC conformance 4.2 Basic calibration Always check the installation before going to sea to make sure that it is not affected by radio transmissions, engine starting etc. Use the following flow chart to carry out basic calibration.

16 ST30 Round Bidata Owner s Handbook depth bidata speed depth speed 2 sec CAL d OFFSET d DEPTH UNITS d LOG UNITS d LOG CALIBRATION If CAL OFF is displayed, press depth or speed to return to normal operation then use the Extended calibration procedure to turn on basic calibration. Offset entry This option is used to select whether the displayed water depth is from the surface or below the Biducer. Set a 0 (zero) offset, to give the depth from the transducer to the seabed. Set a negative offset, to give the depth from the keel to the seabed. Set a positive offset, to give the depth from the waterline to the seabed. 1. At the OFFSET display, press depth and speed together momentarily to enter edit mode. D5040-2

Chapter 4: Calibration 17 2. Use the depth key to increase or speed to decrease the displayed offset. 3. Press depth and speed together momentarily to exit edit mode. Actual Water Depth Biducer Negative Offset D1762-2 Actual Water Depth Biducer Positive Offset D1766-2 Depth units The available depth units are metres or feet. These units are toggled with the depth or speed key. Speed and log units The available speed and log units are Kmh, Mph, Kts, SM and NM. These units are toggled with the depth or speed key. Log calibration To ensure correct speed and log values are displayed, a correction factor must be entered at the log display. The correction factor = Charted distance Average Distance. The charted distance is the distance between two charted objects. Ideally, this should be about 1 nm.

18 ST30 Round Bidata Owner s Handbook Point 1 Point 2 Approximately 1Nm Procedure 1. With the trip display active, motor from point 1 to point 2 and record the distance displayed by the Bidata. 2. Motor from point 2 to point 1 and record the displayed distance. 3. Add the recorded distances together and then divide by two to obtain the average. 4. At the LOG calibration display, press depth and speed together momentarily to enter edit mode. 5. Enter the correction factor (charted distance divided by the average) using the depth key to increase the displayed value and speed to decrease the value. 6. Press depth and speed together momentarily to exit edit mode. Exiting basic calibration D699-2 Press and hold depth and speed together for 2 seconds. 4.2 Intermediate calibration Use the following flow chart to carry out intermediate calibration.

Chapter 4: Calibration 19 depth bidata speed depth speed 6 sec VERSION d REPEATER D5041-1 Software version Repeater Displays the Bidata software version. The Bidata can be used as a master instrument connected directly to the transducer, or, alternatively, as a repeating unit displaying speed and depth information from another instrument. Press speed to toggle between MASTER (R0) and REPEATER (R1) operating modes. In repeater mode: You cannot enter basic calibration. You cannot view or adjust alarms or offsets, or carry out log calibration. Saving intermediate calibration Press and hold depth and speed for 2 seconds. Exit intermediate calibration without saving Press depth and speed together momentarily.

20 ST30 Round Bidata Owner s Handbook Default display The Bidata returns to normal operation 8 seconds after the last key press. 4.3 Extended calibration Use the following flow chart to carry out extended calibration. The extended calibration features illustrated below are cycled using the depth key. depth bidata speed depth speed 15 sec CAL d Momentary s CALIBRATION d BOAT SHOW d DEPTH DAMPING d SPEED DAMPING D5042-1

Chapter 4: Calibration 21 Calibration This screen controls access to basic calibration, to protect the settings from accidentally being changed. Use the speed key (toggle action) to select the required setting: CAL ON (1) or CAL OFF (0). Boat show This is a simulation program for dealer use only: 1 = ON and 0 = OFF. Depth and speed damping Damping controls the rate at which the displayed data is updated. The selectable range, adjusted using the speed key, is between 1 and 15, with 1 providing a rapid update and 15 a slow but smooth display update. Saving extended calibration Press and hold depth and speed together for 2 seconds. Exit extended calibration without saving Press depth and speed together momentarily.

22 ST30 Round Bidata Owner s Handbook

Chapter 6: Specification 23 Specification Voltage range: Size: Depth range: Speed range: Trip: Log: Shallow alarm: Depth offset: Illumination: Operating modes: Transducer type: 10 V to 16.5 V maximum (12 V nominal) 94.15 mm x 54.5 mm 0 to 120 metres 0 to 400 feet 0 to 99.9 knots, mph, or kph 0 to 999 nm, sm, or km 0 to 5999 nm, sm, or km 3 to 33 feet 1 to 10 metres -9.9 to + 9.9 feet -4.0 to + 4.0 metres 3 levels via SeaTalk Single level via 12 V switch Master or repeater Transom mount Biducer

24 ST30 Round Bidata Owner s Handbook

ST30 Round Bidata Template Cut out shaded area only Cut hole to 86 mm (33 /8 in) diameter (max.)

Limited Warranty Certificate Raymarine warrants each new Light Marine/Dealer Distributor Product to be of good materials and workmanship, and will repair or exchange any parts proven to be defective in material and workmanship under normal use for a period of 2 years/24 months from date of sale to end user, except as provided below. Defects will be corrected by Raymarine or an authorized Raymarine dealer. Raymarine will, except as provided below, accept labor cost for a period of 2 years/24 months from the date of sale to end user. During this period, except for certain products, travel costs (auto mileage and tolls) up to 100 round trip highway miles (160 kilometres) and travel time of 2 hours, will be assumed by Raymarine only on products where proof of installation or commission by authorized service agents, can be shown. Warranty Limitations Raymarine Warranty policy does not apply to equipment which has been subjected to accident, abuse or misuse, shipping damage, alterations, corrosion, incorrect and/or non-authorized service, or equipment on which the serial number has been altered, mutilated or removed. Except where Raymarine or its authorized dealer has performed the installation, it assumes no responsibility for damage incurred during installation. This Warranty does not cover routine system checkouts or alignment/calibration, unless required by replacement of part(s) in the area being aligned. A suitable proof of purchase, showing date, place, and serial number must be made available to Raymarine or authorized service agent at the time of request for Warranty service. Consumable items, (such as: Chart paper, lamps, fuses, batteries, styli, stylus/drive belts, radar mixer crystals/diodes, snap-in impeller carriers, impellers, impeller bearings, and impeller shaft) are specifically excluded from this Warranty. Magnetrons, Cathode Ray Tubes (CRT), TFT Liquid Crystal Displays (LCD) and cold cathode fluorescent lamps (CCFL), hailer horns and transducers are warranted for 1 year/12 months from date of sale. These items must be returned to a Raymarine facility. All costs associated with transducer replacement, other than the cost of the transducer itself, are specifically excluded from this Warranty. Overtime premium labor portion of services outside of normal working hours is not covered by this Warranty. Travel cost allowance on certain products with a suggested retail price below $2500.00 is not authorized. When/or if repairs are necessary, these products must be forwarded to a Raymarine facility or an authorized dealer at owner s expense will be returned via surface carrier at no cost to the owner. Travel costs other than auto mileage, tolls and two (2) hours travel time, are specifically excluded on all products. Travel costs which are excluded from the coverage of this Warranty include but are not limited to: taxi, launch fees, aircraft rental, subsistence, customs, shipping and communication charges etc. Travel costs, mileage and time, in excess to that allowed must have prior approval in writing. TO THE EXTENT CONSISTENT WITH STATE AND FEDERAL LAW: (1) THIS WARRANTY IS STRICTLY LIMITED TO THE TERMS INDICATED HEREIN, AND NO OTHER WARRANTIES OR REMEDIES SHALL BE BINDING ON RAYMARINE INCLUDING WITHOUT LIMITATION ANY WARRANTIES OF MERCHANTABLE OR FITNESS FOR A PARTICULAR PURPOSE. (2) Raymarine shall not be liable for any incidental, consequential or special (including punitive or multiple) damages. All Raymarine products sold or provided hereunder are merely aids to navigation. It is the responsibility of the user to exercise discretion and proper navigational skill independent of any Raymarine equipment. Document number: 84064-8 April 2001

Factory Service Centers United States of America Raymarine Inc 22 Cotton Road, Unit D Nashua, NH 03063-4219, USA Telephone: +1 603 881 5200 Fax: +1 603 864 4756 www.raymarine.com Sales & Order Services Telephone: +1 800 539 5539 Ext. 2333 or +1 603 881 5200 Ext. 2333 Technical Support Telephone: +1 800 539 5539 Ext. 2444 or +1 603 881 5200 Ext. 2444 Email: techsupport@raymarine.com Product Repair Center Telephone: +1 800 539 5539 Ext. 2118 UK, Europe, Middle East, Far East Raymarine Ltd Anchorage Park, Portsmouth PO3 5TD, England Telephone: +44 (0)23 9269 3611 Fax: +44 (0)23 9269 4642 www.raymarine.com Customer Support Telephone: +44 (0)23 9271 4713 Fax: +44 (0)23 9266 1228 Email: techsupport@raymarine.com Stick barcode label here Purchased from Purchase date Dealer address Installed by Installation date Commissioned by Commissioning date Owner s name Mailing address This portion should be completed and retained by the owner.