datasheet M25S 24VDC motor Features & benefits

Similar documents
E2K-L. Liquid Level Sensor That Is Unaffected by the Color of the Pipe or Liquid. Liquid Level Sensor. Ordering Information

1999 Microcomponents Technology SLYA017A

Operating instructions Safety Rope Emergency Stop Switches ZB0052 / ZB0053 ZB0072 / ZB0073

Installation & Maintenance Instructions TEC-11N TIMER. Analogue electronic timer 02/09

T i m i n g S y s t e m s. RACEAMERICA, Inc. P.O. Box 3469 Santa Clara, CA (408)

METEOR LSR36500 LIGHTING UNDERWATER POOL LIGHT. Operating Instructions

TECHNICAL MANUAL DHR80 LED. Den Haan Rotterdam MED96/98/EC

Lap Count Display Owner s Manual

SANTA CRUZ BICYCLES Geometry Adjust Flip Chip

2000 lb manual winch

Norrsken Family Booklet

OPERATION AND INSTRUCTION MANUAL

TECHNICAL MANUAL DHR60 LED. Den Haan Rotterdam MED96/98/EC

EPRB-2 Pressure Transducer

DISCLAIMER & COPYRIGHT CONTENTS

Model ASSEMBLY and OPERATING INSTRUCTIONS

COMPACT METAL bender 99826

User's Manual. Heavy Duty Dissolved Oxygen Meter. Model

INSTALLATION INSTRUCTIONS AT-SERIES ANCHOR ASSEMBLY PART NUMBER: F-04CAJP 450 LB. [204kg] MAXIMUM CAPACITY (PRO POOL LIFT)

TECHNICAL MANUAL DHR40 LED. Den Haan Rotterdam MED96/98/EC

3800 SERIES END SUCTION PUMP REPAIR PARTS INDEX. Model Model 3804

OPERATION AND INSTRUCTION MANUAL Swivel Anchor Model: SWY100N

6PS SERIES HERMETIC STAINLESS STEEL PRESSURE SWITCH Introduction

Installation Instructions Air Compressor Part # 2780, 2781

Getting to know your Sureshotgps micro V3

PLAQUE MFM0680 UNDERWATER LIGHT. Operating Instructions

Upper Extremities USER MANUAL ARMS-ESF3GP. Stealth s User Manual and Maintenance Guide for the 3G Fixed Elbow Stop

TWB Shoulder Retractors

Index Table. Model 794. Installation, Operating and Maintenance Instructions

E8AA. Pressure Sensor of Stainless Steel Construction Is Ideal for a Wide Range of Applications. Pressure Sensor (Stainless Steel Diaphragm)

2/2-Way Solenoid Control Valve

444C DUAL PERFORMANCE VALUE PACK

200 PSI COMPRESSORS - MODEL NUMBERS

TANK MANAGER FOR TWO TANKS OPERATING MANUAL. 10/31/11 C-More T6C L color touch panel

ASAHI/AMERICA EFFECTIVE: 12/01/08. Dimensional Guide. Halar (E-CTFE) Piping & Valves

Conductor Bushings Series 8174

TECHNICAL MANUAL DHR55N. Den Haan Rotterdam MED96/98/EC

Model 6810A Dual Lane Scoreboard Owner s Manual Rev B

TECHNICAL MANUAL. DHR70N Polar. Den Haan Rotterdam

RADROVER REAR RACK INSTALLATION MANUAL

GRAVITY BIKE RACK ASSEMBLY & OPERATING INSTRUCTIONS

CONUS MSR0680 UNDERWATER LIGHT. Registered Community Design. Operating Instructions

Owner s Manual & Safety Instructions

Model No Product Name Handpiece Only Complete System

OPERATION AND INSTRUCTION MANUAL Swivel Anchor Model: HD26248

CHANGZHOU TRINA SOLAR ENERGY CO.,LTD. LIMITED WARRANTY FOR TRINA SOLAR BRAND CRYSTALLINE SOLAR PHOTOVOLTAIC MODULES PS M 0020 Rev. M Nov.

Operating Instructions

SonoMeter 30 Energy Meters

A U T O O P E N S E R I E S C A P P R E S S O P E R A T O R S M A N U A L

O P E R A T O R S M A N U A O P E R A T O R S M A N U A L L

MODEL CALIBRATION GAS DELIVERY SYSTEM

TECHNICAL MANUAL DHR80 LED. Den Haan Rotterdam

Fingertip Pulse Oximeter

OPERATION AND INSTRUCTION MANUAL ROLLER SLING Model: IN106.3FT & IN106.2FT

URC Voltage Sensor SEN-VOLT for use with MRX units containing sensor ports

Vevazz. Operation Manual. Vevazz, LLC Rancho California Road. Suite Temecula, CA Phone: (773) Fax: (888)

NuVinci N360 Parts Catalog

FlashGARD HP Reverse Osmosis Filtration System Model Number FSTMO75 Part Number

AC1810 / AC1810-A TECHNICAL SPECIFICATIONS. Operating Pressure psi ( kgs/cm²) [AC1810] Displacement. Net Weight

2018 ACCESSORY ATTACHMENTS OWNER S MANUAL

Introduction INDEX. INTRODUCTION HSE

MP15 Jockey Pump Controller

UNIMAT Basic. Material Testing Machine. for the. Quality Control. with. Software (intern) for Stand Alone Usage

97C COMPRESSOR KIT 12V PART NO C COMPRESSOR KIT 24V PART NO C COMPRESSOR KIT PART NO

Control the air. Control your business.

VOLLEYBALL ALBERTA - WEB PRIVACY POLICY

Series P48. Pressure Controls for Steam, Air or (hot) Water. Product Bulletin. Generous wiring space provided. Splash-proof enclosure (IP54)

MODELS (2 foot Version) (4 foot Version)

METEOR LSR0640 UNDERWATER POOL LIGHT. Operating Instructions

TECHNICAL MANUAL DHR70N. Den Haan Rotterdam

Mini-Pro CO2 Sensor User s Manual - ANALOG MODEL -

ASG-SD2500 ASG-SD2500

)RU FHUWLILHG FRPSDQLHV ROTEX 509 +HDWLQJ FLUFXLW GLVWULEXWRU 2SHUDWLQJ LQVWUXFWLRQV

OVA Privacy Policy. a) Arranges and encourages volleyball matches and competitions within Ontario;

HAI UPB 15A Relay Switch and Auxiliary Switch Installation and Operating Instructions

ASM. Asynchronous Spindle Motors. SEM Limited Faraday Way Orpington, Kent BR5 3QT United Kingdom

Proportional Pressure-Relief Cartridge Valve, Size 2...4

Sensoric 4-20 ma Transmitter Board Operation Manual

PLAQUE MFM18240 UNDERWATER LIGHT. Operating Instructions

Pressure switch KP-E. Data sheet

Inverse Proportional Pressure-Relief Cartridge, Size 10

Inverse Proportional Pressure-Relief Cart., Size 2 4

Transmitter CS 21 Operation Manual

SERIES L4E & L6E LADDER EXTENSIONS

Operating Instructions of BROSA tension load cells, types 0111, 0113

Please have your date code when inquiring about parts.

Cutting device S-16. Operating Instructions Habasit AG Postfach, CH-4153 Reinach-Basel Phone Fax

AE R1 February 2015

OPERATION AND INSTRUCTION MANUAL Flat Roof Anchor Model: FRA250L-10X-CTS

UBEC 1AT. AUTO TANK Fill System Installation, Operation, & Setup Instructions

Fiber Cable Puller with Tuf-Lugger lite

accidents which arise due to non-observance of these instructions and the safety information herein.

The MAXX Press DIGITAL CAP OPERATOR S MANUAL

OptiAir CA09 Pneumaticfluidizing

Mounting instructions. Strain transducer SLB-700A. B 26.SLB700A.10 e

100C Air Compressor Kit

SDS -Series 4C-D201/-D202 Supplemental Drying System User s Manual

TorMinal. Operating instructions V OCE-Rev.L_EN

Acid- Rite ph Adjustment System 2500 by Axiall, a Westlake Company

420C AIR COMPRESSOR KIT PART NO C AIR COMPRESSOR KIT PART NO

Transcription:

datasheet M25S 24VDC motor Features & benefits Slow Start, Slow Stop Starting from any position, the M25S starts very slow for a better quality feel of movement. The end position is smoothly approached by a slow stop. Tension release The fabric or slat package at the top position is slightly turned back, preventing the fabrics sticking in a moist environment. Cord stress and stretching is reduced for extended product lifetime. Three-product-mode The M25S can be used for free hanging and tensioned Duette and Plissé shades, but also with free hanging Venetian blinds. Special features are activated for each product type. Automatic recalibration On each cycle, the motor resets its internal pulse counter when top position is reached. Product elongation over time due to slip or local environment conditions will not affect the end limit positions. Obstacle detection The motor will stop moving the product when it touches a fixed obstacle (e.g. window handle). Less hardware components No more spindle stop for free hanging products is required. No more TimeStop TS-24 module for tensioned Duette /Plissé shades is required. Smart electronics The motor is equiped with current and speed detection. The motor direction is automatically assigned after the first end limits programming. Motorisation version: 1.6

Technical data Rated voltage (VDC) 24 Number of wires 2 (power cable) 3 (programming cable) Nominal torque (Nm) 0.8 Nominal speed (rpm) 30 Current consumption (A) 0.5 Protection rate IP 40 Duty rating Operation temp. ( C) 8 min. on / 8 min. off 0 +60 Prog. cable length (m) 0.14 Power cable length (m) 2.4 Power cable colour White (+); white/grey (-) Connecting cable Ø (mm) 1.43 (AWG 24) Weight (kg) 0.17 Approvals CE Page 2 of 5 version: 1.6

Dimensions Logistics / Applications Article number 17.0120.0000 Min. order qty Application 20 pcs EOS Duette shades EOS Plissé shades Venetian blinds 16/25mm Page 3 of 5 version: 1.6

Accessories Description Product code Packing Unit Figure Motor adapter 29.7645.0952 100 pcs Motor bearing XL 29.7550.0000 200 pcs Grubscrew M3x8 29.7546.0000 250 pcs Square nut M3 29.7857.0000 250 pcs Limit B key 17.0124.0155 10 pcs Handheld programming tool 17.0127.0000 1 pc Page 4 of 5 version: 1.6

Safety instructions The motor may only installed by qualified personnel who: have read and understood the mounting instructions of both blind and motor are familiar with the electronic safety aspects recognize and avoid danger which can be produced from the mechanical or electrical components always observe and are familiar with the local safety, labour regulations and laws Never drop the motor! Never drill into the motor! Do not immerse into liquid! Avoid collisions! Do not cut any cables! Important notice Hunter Douglas Europe B.V. and its affiliates (Hunter Douglas) reserve the right to make corrections, enhancements, improvements and other changes to its products and services, and to discontinue any product or service. Buyers should obtain the latest relevant information before placing orders and should verify that such information is current and complete. All products (also referred to herein as "components") are sold subject to Hunter Douglas terms and conditions of sale supplied at the time of order acknowledgment. Hunter Douglas warrants performance of its components to the specifications applicable at the time of sale, in accordance with its standard warranty terms. Testing and other quality control techniques are used to the extent Hunter Douglas deems necessary to support this warranty. Except where mandated by applicable law, testing of all parameters of each component is not necessarily performed. Hunter Douglas assumes no liability for applications assistance or the design of Buyers' products. Buyers are responsible for their products, applications and interfaces using Hunter Douglas components. To minimize the risks associated with Buyers' products and applications, Buyers should provide adequate design and operating safeguards. Hunter Douglas does not warrant or represent that any license, either express or implied, is granted under any patent right, copyright, mask work right, or other intellectual property right relating to any combination, machine, or process in which Hunter Douglas components or services are used. Information published by Hunter Douglas regarding thirdparty products or services does not constitute a license to use such products or services or a warranty or endorsement thereof. Use of such information may require a license from a third party under the patents or other intellectual property of the third party, or a license from Hunter Douglas under the patents or other intellectual property of Hunter Douglas. Reproduction of Hunter Douglas information in Hunter Douglas data sheets is permissible only if reproduction is without alteration and is accompanied by all associated warranties, conditions, limitations, and notices. Hunter Douglas is not responsible or liable for any altered documentation. Information of third parties may be subject to additional restrictions. Resale of Hunter Douglas components or services with statements different from or beyond the parameters stated by Hunter Douglas for that component or service voids all express and any implied warranties for the associated Hunter Douglas component or service and is an unfair and deceptive business practice. Hunter Douglas is not responsible or liable for any such statements. Buyers acknowledge and agree that they are solely responsible for compliance with all legal, regulatory and safety-related requirements concerning its products, and any use of Hunter Douglas components in its applications, notwithstanding any applications-related information or support that may be provided by Hunter Douglas. Buyers represent and agree that they have all the necessary expertise to create and implement safeguards which anticipate dangerous consequences of failures, monitor failures and their consequences, lessen the likelihood of failures that might cause harm and take appropriate remedial actions. Buyers fully indemnify Hunter Douglas and its representatives against any damages arising out of the use of any Hunter Douglas components in safety-critical applications. Page 5 of 5 version: 1.6