A Higher Level of Performance. Data Sheet. Series Pressure and Level Transmitters. For more information, please visit >

Similar documents
Series INTELLIGENT PRESSURE- AND LEVEL TRANSMITTERS For all industries. Description ALL STAINLESS DESIGN

Series INTELLIGENT PRESSURE- AND LEVEL TRANSMITTERS For all industries. Description ALL STAINLESS DESIGN

x act i Precision Pressure Transmitter for Food Industry, Pharmacy and Biotechnology Stainless Steel Sensor accuracy according to IEC 60770: 0.

9700 Transmitter Submersible hydrostatic level transmitter

2 Overview. SITRANS P measuring instruments for pressure. Transmitters for gage and absolute pressure. Z series for gage pressure

SITRANS P measuring instruments for pressure

x act i Precision- Pressure Transmitter for Food Industry, Pharmacy and Biotechnology Stainless Steel Sensor

Pressure Measurement. Transmitters for basic requirements SITRANS P Z for gauge pressure. 2/4 Siemens FI Overview

ATM/Ex - Analog Pressure Transmitter

DMK 458. Pressure Transmitter for Marine and Offshore. Ceramic Sensor. accuracy according to IEC 60770: standard: 0.25 % FSO option: 0.

ED 701 Hygenic Pressure Transmitter

ATM/Ex - Intrinsically Safe Analog Pressure Transmitter - ATEX / IECEx Certified

ATM.ECO/IS - Analog Transmitter with Temperature compensation

INSTRUCTION MANUAL ("HART") "INTELLIGENT" PRESSURE- AND LEVEL TRANSMITTERS

How to specify a product. Process Sensors and Mechanical Instruments

OPTIBAR P 1010 C Technical Datasheet

Hydrostatic. Continuous level measurement. Overview Page 188 VEGAWELL 52 Page 190 VEGABAR 86, 87 Page 192 Accessory Page 196 AL-EN

Pressure Measurement Single-range transmitters for general applications

ATM.1ST/Ex - High Precision Transmitter

ATM/GR. Electronic pressure switches CUSTOMER BENEFITS

2600T Series Pressure Transmitter Models 264DC Differential and 264HC Gage Level Transmitters. Kent-Taylor

ATM - Analog Pressure Transmitter

Technical Datasheet. D Series SMART Pressure Transmitter Model: DPC D-Series. Key Features. Series Overview. Product applications

Differential Pressure Transmiter

200A Series ELECTRONIC LEVEL TRANSMITTER

Level switches Series LD Vibrating fork level switch for liquids and solids

RTX 1000H Series. Versatile Transmitters for a World of Pressure. GE Measurement & Control. Features

Expert Hydrostatic Level Transmitters

Torque Tube TB300 Digital Transmitters

L (up to 25 m) Electronic part. working temp.: Ñ IP 66 / IP67. Mounting bracket ÐÑ. Sensor type. working temp.:

Level switches Series LD Vibrating fork level switch for liquids and solids

3.0 Pressure Transmitter Selection

Type N-10, N-11 Hazardous Area Non-incendive Transmitters

C-Flow Coriolis Mass Flow Meters

Pressure Transmitter P41

KDV HIGH ACCURACY GLASS TUBE ROTAMETER

Bourdon tube pressure gauge for diaphragm seals

SITRANS P measuring instruments for pressure

PULP & PAPER INDUSTRY

MJK Expert 700 / 800 / 900 / 7070 / 7060 MJK Expert 1400 / 3400

Ultrasonic. 58 Overview VEGASON 60 VEGASON 61, 62, 63

Climatic Independent Level Sensor LAR

VersaFlow Vortex 100 Vortex Flow Meter Technical Datasheet. Specification. The all-in-one solution. Highlights. Industries.

ATM.1ST. Pressure transmitters CUSTOMER BENEFITS

High-performance submersible pressure transmitter For level measurement Model LH-10

Siemens AG Transmitters with WirelessHART 1/42 SITRANS P280 for gauge and abs. pressure. Transmitters for food, pharmaceuticals

ATM.ECO - Analog Pressure Transmitter

1 Overview. Pressure Measurement Transmitters for basic requirements. 1/16 Siemens FI SITRANS P220 for gauge pressure

NivuBar Plus II

Pressure Measurement Single-range transmitters for general applications

Ultrasonic level transmitter and indicator

KTE6000 / KTU6000 Series OEM pressure transmitters for industrial media

Pressure Transmitter cerabar M PMC 41, PMC 45 cerabar M PMP 41, PMP 45

KDV HIGH ACCURACY GLASS TUBE ROTAMETER

Mobrey 9700 Transmitter Submersible Hydrostatic Level Transmitters

Smart performance with innovative and ever-strong coil drive even under harsh working environments

Ultrasonic. Continuous level measurement. Overview Page 64 VEGASON series 60 Page 66 AL-EN

Technical Datasheet. Pressure Transmitter: Analogue Series 387. Performance characteristics. Product applications. How can we help you?

Type S-10, S-11 General Purpose Pressure Transmitters

Level transmitters and indicators Series LU Ultrasonic level transmitter and indicator for liquids and solids

L3 Pressure and Level transmitter

APG. Intrinsically Safe, Heavy Duty Pressure Transducer Series: PT-400

UNIK 5600/5700 Marine Certified Pressure Sensing Platform

TYPE APPROVAL CERTIFICATE

Viatran s Sanitary Pressure and Level Measurement Family

JUMO dtrans p30 Pressure Transmitter

SITRANS. Pressure transmitter SITRANS P, Z series for gauge and absolute pressure. Introduction. Safety instructions 2.

The M-Series Eletta Flow Meter High accuracy DP Flow Meter with multiple functions

Climatic Independent Level Sensor LAR

1 Overview. Pressure Measurement Single-range transmitters for general applications. 1/16 Siemens FI US Edition

VG5 Supplementary instructions

MPM426W/436W Submersible Level Transmitter

2600T Series Pressure Transmitter

P900. P900, Datenblatt Seite 1 DESCRIPTION

MPM416W/WK/WRK Submersible Level Transmitter

LMP 307. Stainless Steel Probe. Stainless Steel Sensor. accuracy according to IEC 60770: standard: 0.35 % FSO option: 0.25 % / 0.

SITRANS P pressure transmitters The best in pressure measurement. sitrans

P9000 DESCRIPTION. For parts requiring RoHS compliance, please contact factory. P February /6

High-performance submersible pressure transmitter For level measurement Model LH-10

Programmable pressure and temperature transmitters PTM/RS485

Dynisco SPX Industrial (2280/2281) Series

ellison sensors international

sitrans p Operating Instructions (de/en) Edition 03/2004

Mechanical Pressure Measurement

INDUSTRIAL. Pressure Transmitters. Product Guide. Low cost to high accuracy portfolio. Ranges from 70 mbar to 1400 bar. Flexible, rugged and reliable

Programmable pressure and temperature transmitters PTM/RS485

Climatic Independent Level Sensor LAR

3000 Series OPTIMASS Mass Flowmeter. Stainless Steel Hastelloy

Two-Wire In Situ Oxygen Analyzer (550 to 1400 C)

Climatic Independent Level Sensor LAR

Certified according to DIN EN ISO 9001 Technical Datasheet TRICOR Series Mass Flow Meters

Differential pressure

XMO2. Panametrics Smart Oxygen Analyzer. Applications. Features. bhge.com. An oxygen transmitter for use in:

BSP Pressure Sensor Balluff GmbH, BA Marco Zorcic.

Pressure transmitter PASCAL Ci4

PRESSURE & TEMPERATURE GAUGES PRESSURE TEMPERATURE. Catalogue H20200a

Pressure Switches Application Guideline

Brooks TMF-Zone 1 Models 5816-Ex/5864-Ex

Cerabar M PMC41/45, PMP41/45/46/48

Pressure Transmitters 36 F-27839

Transcription:

A Higher Level of Performance Data Sheet Pressure and Level Transmitters For more information, please visit > www.hawkmeasure.com

Description Intelligent pressure and level transmitters for all industries () The is a complete range of intelligent pressure and level transmitters with local display and adjustment by three push buttons. The push buttons are used to set Zero and Span. Test pressures are not required for calibration. The display which can indicate a number of chosen engineering units is also used during programming to assist the easy operation. Process temperatures can be shown and damping times can be adjusted from 0 to 25 secs. Also a 4-20 ma Current Simulation can be performed. The is fully temperature compensated. Over 40 different process connections are available including many flush diaphragm designs. Options include ATEX approval, HART protocol or PROFIBUS-PA output. HART is a registered trademark of the HART Communication Foundation Features All Stainless design Easy calibration without test pressure by 3 push buttons Accuracy 0.1% 4-20 ma and HART protocol ATEX II 1 G and II 1 D Wide rangeability Local display Adjustable damping More than 40 different process connections Profibus-PA

Description The series 2000 pressure transmitter has been specially designed for measuring pressure in pulp and paper mills and similar industries where plugging is a problem. The transmitters are fully temperature compensated, and have very strong, flush mounted diaphragms. Zero and span can be adjusted without test pressure by 3 push buttons or by hand-held-terminal (HART, option). Specifications Accuracy : 0,1% of adjusted span Measuring ranges : 0-0,1 bar to 0-100 bar Output signal : 4-20 ma / 2-wire HART protocol (option) PROFIBUS-PA (option) Adjustment : by 3 push buttons or H.H.T. Power supply : 12-36 Vdc (Exi: 13-26,5 Vdc) Protection grade : IP66 (Option: IP68) Process temperature : -20 C to +80 C (Option: 100 C) Ambient temperature : -20 C to +70 C* Temperature effect : ±0,010% / K Wetted parts : AISI 316 (standard) Electronic housing : AISI 304 Process connections : See below. Also available PMC, Vega, E+H, etc... Specify code X.. Process connections ZERO SPAN PROG Code: W Weld-on nipple ø 33 mm Code: X12 PASVE connection Code: S 1 BSP (G1 ) Dimensions (mm) Code W Parts description 1. Cover 2. Push buttons + display (behind cover) 3. Cover with Venting 4. Venting 5. Cable entry 6. O-ring 7. Electronics housing 8. Foot with cooling fins 9. O-ring (code W), code S = G1 thread 10. O-ring 11. M8 Bolt 12. Diaphragm 13. Weld-on nipple ø 33 mm Code S 3

-SAN Description The 2000-SAN series are designed for all pressure and level measurements in the food and beverage, chemical and pharmaceutical industries. All hygienic process connections are available, most of them are according to the EHEDG, 3-A and FDA regulations. The transmitters are fully temperature compensated, and have very strong, flush mounted diaphragms. Zero and span can be adjusted without test pressure, over wide ranges, by 3 push buttons, or hand-held terminal (HART, option). Specifications Accuracy: Measuring ranges: Output signal: Adjustment: Power supply: External load: Protection grade: 0,1% of adjusted span 0-0,04 bar to 0-100 bar 4-20 ma / 2-wire HART protocol (option) PROFIBUS-PA (option) by 3 push buttons or H.H.T. 12-36 Vdc (Exi: 13-26,5 Vdc) 600 Ohm / 24V to 1200 Ohm / 36V IP66 (Option: IP68) Process temperature: -20 C to +100 C (145 / 45 min) Ambient temperature: -20 C to +70 C* Temperature effect: ±0,010% / K Wetted parts: AISI 316 (standard) Option: Hastelloy C, Tantalum or Goldplated Electronic housing: AISI 304 Process connections: all industrial process connections available (more than 40*) Process connections ZERO SPAN PROG Code: M Milkcoupling (DN 25, 40 or 50) Code F Flange (DIN or ANSI) Code W85 Weld-on nipple ø 85 mm Dimensions (mm) Code F Parts description 1. Cover 2. Push buttons + display (behind cover) 3. Cover with venting 4. Venting 5. Cable entry 6. O-ring 7. Electronics housing 8. Foot 9. Lock ring 10. Weld-on nipple (W) or Flange (F) 11. Packing 12. Flush diaphragm Code W Also available with separate (remote) electronics. Vented cable between process connection and SS electronics housing, type: 2000-SAN-Cable 4

Series CER 2000 - Peramic S Description The Peramic S, series CER-2000, is a pressure transmitter based on a ceramic measuring sensor. The CER-2000 series is fully temperature compensated and is made for all pressure applications in clean liquids, gases and vapours. The ceramic measuring cell can withstand high overpressures, and is sealed by an o-ring (viton as standard, other materials on request). Zero and span can be adjusted without test pressure over wide ranges, by 3 push buttons or by a hand-held terminal (HART, option). Specifications Accuracy: Measuring ranges: Output signal: Adjustment: Power supply: Protection grade: 0,1% of adjusted span 0-2 bar to 0-400 bar 4-20 ma / 2-wire HART protocol (option) PROFIBUS-PA (option) by 3 push buttons or H.H.T. 12-36 Vdc (Exi: 13-26,5 Vdc) IP66 (Option: IP68) Process temperature: -20 C to +90 C Ambient temperature: -20 C to +70 C* Temperature effect: ±0,010% / K Measuring sensor: ceramic (Al2O3) Sensor sealing: viton o-ring (standard) other materials on request Other wetted parts: AISI 316 (standard) Material housing: AISI 304 Process connections Code: R 1/2 BSP (DIN 16288) Code S 1/2 BSP M and 1/4 BSP F ZERO SPAN PROG Code N 1/2 NPT M and 1/4 NPT F Dimensions (mm) Code R Parts description 1. Cover 2. Push buttons + display (behind cover) 3. Cover with venting 4. Venting 5. Cable entry 6. O-ring 7. Electronics housing 8. Foot with cooling fins 9. Ceramic sensor 10. Process connection Code S 5

General Information Calibration As standard the is always equipped with a display and 3 push buttons for easy calibration. Both the measured and the calibrated value can be read locally. A full calibration can be completed using the three push buttons or with the optional handheld terminal (HART ), or with special software. Zero and span can be calibrated very easy, without test pressure, also in vacuum ranges. Linearisation can be made for various tankshapes like horizontal and conical tanks (P111). For all other adjustable points see table right. The series 2000 will as standard be delivered with 2 closed covers, so the 3 push buttons and the standard display are behind the cover. A cover with transparent plastic can be delivered as an option (I). In that case you can use the display as a local indicator. Adjustable points P101 Zero adjustment (4 ma) P102 Span adjustment (20 ma) P103 Cancel mounting position effect P104 Adjustment pressure unit (see conversion table) P105 4-20 ma* 20-4 ma (reverse output) P106 Damping adjustment (0 to 25 sec) P107 Indication of process temperature (read out on display) Certificates and options P108 0 = CELC C * 1 = FAHR F P109 Read out on display: 0 = current (4-20 ma) * 1 = pressure unit 2 = percent % P110 Current simulation (4-20 ma) P111 Linearisation (Various tankshapes) * = factory setting Temperature Compensation All our transmitters are fully temperature compensated. All transmitters with flush diaphragm are equipped with the unique Flush Diaphragm Technology. (Detailed documentation available). For High Temperature Applications where the process temperature is continuously above 100 C we manufacture special transmitters with cooling fins to reduce the temperature (-SAN with HT option). With a compact 2000-SAN transmitter with option HT we can go up to 200 C and with separation by a cable between process connection and electronics housing (Type: 2000-SAN-Cable- HT) we can go up to 300 C continuously! The HT option is only available on series 2000-SAN (except range 1 and 2) * Transparent cover (I) with option Ex: Min. amb. temp. -10 C 2000-SAN-HT 6

Ordering Codes / 2000-SAN Ranges (bar) Maximum overpressure (bar) Adjustable span range (bar) 0-0,1...0,4 6,4 0-0,1 to 0-0,4 1 0-0,3...1,2 10,5 0-0,3 to 0-1,2 2 0-1...10 30 0-1 to 0-10 3 0-5...30 100 0-5 to 0-30 4 0-20...100 200 0-20 to 0-100 5 PROCESS CONNECTIONS: Weld-on nipple diam. 33 mm (flush diaphragm / pulp & paper) W G1" (1" BSP) threaded connection (flush diaphragm) S PASVE 1" connection (Satron / Valmet) X12 Other connections: i.e. PMC (X2), Valcom, Vega etc (specify X code) X.. OPTIONS: Transparent cover, display functions as local indicator I Vacuum Ranges (Specify Relative or absolute) Compound ranges available (example -1 / +1 bar) V Intrinsically safe: ATEX II 1 G Ex ia IIC T4 Ga and/or II 1 D Ex ia IIIC T100 o C Da IP6X Ex HART Protocol PROFIBUS-PA output (Not available in Ex) H P -SAN -SAN -SAN Ranges (bar) Maximum overpressure (bar) Adjustable span range (bar) 0-0,1...0,4 6,4 0-0,1 to 0-0,4 1 0-0,3...1,2 10,5 0-0,3 to 0-1,2 2 0-1...10 30 0-1 to 0-10 3 0-5...30 100 0-5 to 0-30 4 0-20...100 200 0-20 to 0-100 5 PROCESS CONNECTIONS: Milk coupling DIN 11851, DN 25 (only ranges 3 and 4), DN 40, DN 50 (all ranges) M.. Hygienic weld-on nipple diam 62 mm or 85 mm (specify, for example: W85) W.. Tri-clamp 11/2, 2 or 3 (specify size) L.. Flange: DN 25, 40, 50 or 80 (DIN) or 11/2, 2 or 3 (ANSI) (specify size) F.. Other connections: G11/2 (X3), Varivent(X4), IDF(X5), DRD(X7), SMS (X9), etc... (specify X code) X.. OPTIONS: Transparent cover, display functions as local indicator I Vacuum Ranges (Specify Relative or absolute) Compound ranges available (example -1 / +1 bar) V HIGH Temperature version with cooling fins. Always specify Process Temperature HT Intrinsically safe: ATEX II 1 G Ex ia IIC T4 Ga and/or II 1 D Ex ia IIIC T100 o C Da IP6X Ex HART Protocol PROFIBUS-PA output (Not available in Ex) H P 7

Ordering Codes Series CER-2000 Series CER-2000 Series CER-2000 Series CER-2000 Ranges (bar) Maximum overpressure (bar) Adjustable span range (bar) 0-2...10 50 0-2 to 0-10 3 0-10...40 120 0-10 to 0-40 4 0-40...200 350 0-40 to 0-200 5 0-150...400 300 0-150 to 0-400 6 PROCESS CONNECTIONS: G 1/2 ( 1/2 BSP) manometer (gauge) connection DIN 16288 R G 1/2 (male) and G 1/4 (female) S 1/2 NPT (male) and 1/4 NPT (female) N OPTIONS: Transparent cover, display functions as local indicator I Vacuum Ranges (Specify Relative or absolute) Compound ranges available (example -1 / +1 bar) V Intrinsically safe: ATEX II 1 G Ex ia IIC T4 Ga and/or II 1 D Ex ia IIIC T100 o C Da IP6X Ex HART Protocol PROFIBUS-PA output (Not available in Ex) H P All company or product names are registered trademarks or trademarks of their respective owners. Hawk Measurement Systems Hawk Measurement (Head Office) 96 Glenn Street 15-17 Maurice Court Lawrence, MA 01843, USA Nunawading VIC 3131, AUSTRALIA Phone: +1 888 HAWKLEVEL (1-888-429-5538) Phone: +61 3 9873 4750 Phone: +1 978 304 3000 Fax: +61 3 9873 4538 Fax: +1 978 304 1462 info@hawk.com.au info@hawkmeasure.com For more information and global representatives: www.hawkmeasure.com Additional product warranty and application guarantees upon request. Technical data subject to change without notice. Represented by: DOC-SERIES2000-DAT Rev.1.0 0216