INSTALLATION AND OPERATING INSTRUCTIONS

Similar documents
Semi-Automatic Controllers

INSTALLATION AND OPERATING INSTRUCTIONS

MAGNA-CHEM AUTOMATIC CHLORINATOR - MODEL: CSA-2P MAGNA ORP Chlorine Pump

VX Series Salt Chlorinator S Model

Hurlcon KX Siesta Above Ground Salt Water Chlorinator by AstralPool Australia

VX Series Salt Chlorinator T Model

INSTALLATION AND OPERATING INSTRUCTIONS

INSTALLATION AND OPERATING INSTRUCTIONS

INSTALLATION AND OPERATING INSTRUCTIONS

Bolero ND Cleaner. VX - 3 Series Salt Chlorinator INSTALLATION AND OPERATING INSTRUCTIONS

HIGH PERFORMANCE POOL & SPA PUMPS

INSTALLATION AND OPERATING INSTRUCTIONS

INSTALLATION AND OPERATING INSTRUCTIONS

VX-3 Series Salt Chlorinator

Vessel Installation and Operating Manual

Jacuzzi. J-SS40 Salt System Installation and Operating Instructions

Operating Manual RP and SMT Models

RAMZONICS. Saltwater Chlorinator

Installation and Operating Manual

VAC-U DRIVE Swinging float arm for Acrobat like agility 36 Fin disk with DEEP VEE Scoop

APVMA Approval No /3/0204. Instruction Manual & Warranty Card

INSTALLATION & OPERATION MANUAL

SPECIFICATIONS Type: Twin stack, single phase Tank: 4 gallon Air Output: PSI; PSI Max PSI: 125 PSI HP: 1.

PLEASE READ CAREFULLY BEFORE INSTALLING OR USING MEGA POOL SAVER MPS 1100

Installation and Operating Instructions

CLEANING AUTO CELL OWNERS HANDBOOK

CARTRIDGE FILTERS. Models: CF50, CF75, CF100, CF150,

ROK:XP Salt Chlorinator INSTALLATION & OPERATION. performance on demand. focus. NORIA performance on demand WATER FLOW DIRECTION POWER TIMER CELL

Purifier for Vinyl Lined Pools

RG2200 BC Integrated Octopus

MPULSE 3000TM. Instruction & Owner s Manual. Pool Water Treatment System. 890 W.Grant Rd., Tucson, AZ, (877) * (520) Fax

OWNER S MANUAL NMB SERIES

INSTALLATION AND OPERATING INSTRUCTIONS

INSTALLATION AND OPERATING INSTRUCTIONS

OXYGEN MINERALE ABSOLUTE RANGE OWNER S MANUAL OXY MINERALE 600/1000 SERIES

444C DUAL PERFORMANCE VALUE PACK

NB/NBR NITROGEN BOOSTER FOR AVIATION SERVICE

Accu-Tab PowerBase 3070AT by Axiall Corporation

400C & 450C DUAL PERFORMANCE VALUE PACKS

Parts and Owners Manual

MODEL NUMBER: AS18-2 USER GUIDE

CastCreations PRODUCT DESCRIPTION. Redwood Stump Fire Pit Item #: C1002. CastCreations Ph: Aurora, Utah

IMPORTANT SAFETY INSTRUCTIONS

INSTALLATION AND OPERATING INSTRUCTIONS

Swimming Pool IAQUALINK WEB CONNECT

SSFU SUPER SPRAYFAST UNIVERSAL ADHESIVE APPLICATOR

INSTALLATION AND OPERATING INSTRUCTIONS. Chlorinator

Installation and Operation Manual

User Instruction Manual

FLUSHMATE III FLUSHMATE FLUSHOMETER - TANK SYSTEM. Owner s Service Manual. 503 Series. 503 Series

100C Air Compressor Kit

Page INDEX SAFETY INSTRUCTIONS... 2 HOW YOUR AQUASPHERE CHLORINATOR WORKS... 3 AQUASPHERE CHLORINATOR OPERATION... 4 CONTROL PANEL FUNCTIONS...

Pressure Injection Cell Operator s Manual

CHEMICAL INDUCTION KIT (Pt.No Issue 6, October 2015)

2 GALLON TWIN STACK AIR COMPRESSOR W/ HOSE REEL

Saltwater Chlorinator. Instruction Manual & Warranty

UNIVERSAL GAS FRYER Instruction Manual Model #8065NS

Model No Product Name Handpiece Only Complete System

PoolNaturally. Pure. Simple. Genius. Installation and Product Use Instructions In ground and above ground pools

480C DUAL PERFORMANCE VALUE PACK

accidents which arise due to non-observance of these instructions and the safety information herein. SPECIFICATIONS

400H HARDMOUNT AIR COMPRESSOR KIT PART NO H HARDMOUNT AIR COMPRESSOR KIT PART NO

SPECIFICATIONS APCEPH1

Accu-Tab PowerBase 3140AT by Axiall Corporation

450P AUTOMATIC PORTABLE COMPRESSOR EXTREME SERIES

200 PSI COMPRESSORS - MODEL NUMBERS

Installation of Your SprayMaster System

SIX R (P ) AND SEVEN R (P ) POSITION CYLINDERS Service Information

H.R.UV-C. Installation & Operating Manual HR-55 HRP-55 HR-110 HRP-110

Pressure Dump Valve Service Kit for Series 2300 Units

Pressure Dump Valve Service Kit for Series 3000 Units

Part IV: Troubleshooting

420C AIR COMPRESSOR KIT PART NO C AIR COMPRESSOR KIT PART NO

MODEL NUMBER: P PORTABLE COMPRESSOR

MODEL NUMBER: P-A AUTOMATIC PORTABLE COMPRESSOR

PRISTINE CHLORINATOR & CELL OWNER S MANUAL

WATER HEATER THERMAL EXPANSION TANKS Owner s Manual. Safety Instructions Installation Maintenance Warranty. Models: 2-5 Gallon Capacity

RG3100 and RG3100Ice Regulator System

250C-IG COMPRESSOR KIT 12V PART NO C-IG COMPRESSOR KIT 24V PART NO

450P- RV AUTOMATIC PORTABLE COMPRESSOR EXTREME SERIES

Assembling & Installing your Pool Cleaner

AQQWALKING TREAD MILL

Parts Manual. Frusheez Machines

250C-IG COMPRESSOR KIT 12V PART NO C-IG COMPRESSOR KIT 24V PART NO

User's Manual. MixRite TF 10. Edition 05.08

G7S Hand Pump Owner s Manual

DISASSEMBLING & REASSEMBLING CARTRIDGE INSTALLING SEATPOST ON BIKE

97C COMPRESSOR KIT 12V PART NO C COMPRESSOR KIT 24V PART NO C COMPRESSOR KIT PART NO

Water Management System User Manual

MODEL NUMBER: M20005 AIR SOURCE KIT. 30% Duty Compressor on. 2.0 Gallon Air Tank SAVE THIS MANUAL FOR FUTURE REFERENCE

AWG Fittings LLC. Pressure Relief Valve Up to 250 PSI. Product Number Read this instruction manual before use.

Jacuzzi. J-CQ420 Cartridge Filter Installation and Operating Instructions

Gas Countertop Hot Plates

Accu-Tab PowerBase 3012AT by Axiall Corporation

R E D I C O N T R O L S

310 SERIES TILT-TO-LOAD ROTATOR. The Specialist In Drum Handling Equipment

AIR COMPRESSOR. Failure to follow all instructions as listed below may result in electrical shock, fire, and/or serious personal injury.

Standard Gas Countertop Griddle

Accu-Tab Systems 1000 Series by Axiall Corporation

XpressFill XF4500C Counter Pressure Can Filler. Operating Instructions

Transcription:

INSTALLATION AND OPERATING INSTRUCTIONS I INSTALLATION AND OPERATING INSTRUCTIONS Bolero RC1 Semi-Automatic ND Cleaner Controllers INSTALLATION AND OPERATING INSTRUCTIONS Melbourne: 03 8796 8600 Gold Coast: 07 5552 2600 Perth: 08 9350 2600 Sydney: 02 9853 2100 Townsville: 07 4750 3100 sales@astralpool.com.au Brisbane: 1/08/2014 07 3308 5400 Adelaide: 08 8152 7600 www.astralpool.com.au

Congratulations, you have made a good choice in purchasing a RolaChem RC1 controller by Astral Pool. Swimming pool chemistry is quite interesting and dynamic. There is no one setting that is right for every swimming pool or spa. Let the RC1 settle down over a couple of days and then if necessary alter the setting to suit your pool or spa. If large quantities of chemicals are dumped in the pool water, this excess quantity should be circulated well and then, allowed to settle down before this machine starts to give true readings. If you have any questions please contact your Astral Pool supplier or us directly. INDEX Note: The appliance is not intended for use by young children or infirm person without supervision. Please ensure that young children are supervised to ensure that they do not play with the appliance. If the supply cord is damaged, it must be replaced by the manufacturer or its service agent or a similarly qualified person in order to avoid a hazard. Power to this controller must be either; Supplied by an isolating transformer Supplied through a residual current device (RCD) with a rated residual operating current not exceeding 30mA INDEX STARTING UP.. 3 INSTALLATION 3 RC-1 TYPICAL INSTALLATION. 5 MAINTENANCE.. 6 TROUBLE SHOOTING GUIDE 6 WARRANTY 7 INST234 RolaChem RC1 Semi - Automatic Controllers V07_14 2

STARTING UP Before starting up your RC1 controller, it is advisable that the pool water be balanced. Recommended chemical ranges (depending on pool location and pool surface) are: CHLORINE: 1-3ppm ph 7.2-7.8 STABILISER: 30-50 mg/l TOTAL ALKALINITY: 80-150 mg/l CALCIUM HARDNESS: 90-300 mg/l INSTALLATION PLEASE READ ALL THESE INSTRUCTIONS CAREFULLY BEFORE INSTALLING & OPERATING THE UNIT AND LEAVE THE MANUAL ON SITE FOR OWNER/OPERATOR S USE ROLA CHEM SYSTEMS SHOULD OPERATE ONLY WHEN THE POOL FILTER IS OPERATING.THE UNIT MUST NOT BE CONNECTED WITHOUT ADEQUATE EARTH CONNECTIONS AND A VOLTAGE OTHER THAN 230-250V Before installing the unit in position on the wall or post, the length of the PVC tubing provided should be measured and taken into consideration. To avoid loss of water from the system, close all stop valves before cutting any lines. Connection of lines (see illustration page 4) Install the T pieces into the return line. Cut an appropriate piece out of this line and glue the T piece in position, using a PVC adhesive. Thread the PVC tube through the hole in the cap or shoulder of the chemical container and fit the non-return or check valve and the weight. Ensure that the non-return valve is fitted correctly (arrow indicates the direction of flow) Drop the weight, with the non-return valve into the bottom of the container. TIP: Soaking the ends of the PVC tubing in hot water or gentle heating with a lighter makes it easier to push onto the barb. When installing chemical containers (especially acid), in filter enclosures, which have no ventilation, it is recommended that the hole in the cap of the container is cut to fit tightly around the tubing, so that fumes from the acid or chlorine will not corrode the equipment. It will be necessary to drill a second hole in the cap fitted tightly with a length of tubing which should then be vented outside the filter enclosure. This procedure is recommended only where the filter enclosure has no ventilation and is to protect the equipment. IMPORTANT: RolaChem pumps dose against a maximum pressure of 150-175 kpa (20-25 psi), avoid excessive pressure situations such as: In-floor cleaners (when using for pool applications): The recommended position of the injection point and probe is on the suction line. ACID SHOULD BE DILUTED MINIMUM 1:2, MORE DILUTION IS OK ALWAYS ADD ACID TO WATER (NOT WATER TO ACID) NEVER MIX CHEMICALS INST234 RolaChem RC1 Semi - Automatic Controllers V07_14 3

Placement of Chemicals Placement of Rola Chem Unit Connection of Lines INST234 RolaChem RC1 Semi - Automatic Controllers V07_14 4

RC-1 TYPICAL INSTALLATION Select number 10 setting on the control dial. The machine will commence to draw the chemical from the controller when the chemical begins to drop down the PVC tubing reset the dial to the desired level. The RC 1 has a pre purge built into the machine and therefore has a delay start up of 1 minute. RC1 Dial Setting * Pool Volume Acid Dosing ** Chlorine Dosing 1RPM 5RPM 20RPM 5RPM 20RPM 100RPM 25000 2 N/A N/A 1.5 N/A N/A 30000 2 N/A N/A 2 N/A N/A 40000 2.5 1 N/A 2 N/A N/A 50000 3 1 N/A 2.5 1 N/A 60000 3.5 1 N/A 3 1 N/A 75000 4 1.5 N/A 3 1 N/A 90000 5 1.5 N/A 4 1.5 N/A 120000 6 2 N/A 5 1.5 N/A 150000 8 2 N/A 6 2 N/A 200000 10 2.5 1 8 2 N/A 250000 N/A 3 1 10 2.5 N/A 300000 N/A 3 1.5 N/A 3 1 500000 N/A 5 2 N/A 5 1.5 * Based on 8 hours operation per day * Based on 1 part hydrochloric acid to 2 parts water mix. If using different types or concentrations of acid, please consult your pool professional. INST234 RolaChem RC1 Semi - Automatic Controllers V07_14 5

MAINTENANCE 1. The injection point (where the chlorine discharges into the pool line) should be checked periodically for any build up of solid matter like Calcium at the end of the PVC tubing and kept clean. This may otherwise cause blockage hindering the passage of chlorine into the pool and shorten the life of the pump tube and roller block. While unscrewing the black injection nut, take care not to lose the rubber grommet and silver ring. 2. Lubricate the squeeze (pump) tube every 6 months, more often in commercial applications. Use only the recommended lubricant RC Tube Lube, available from Hurlcon, or any compatible silicone lubricant, otherwise damage can result. 3. Depending on usage, the squeeze (pump) tube may need replacement after 1-2 years on a domestic pool installation, after 6 months on a commercial installation. Before replacing the tube make sure that any stop valves in the filter system are closed. Otherwise water loss may occur. (To replace this tube, remove the retaining screws or wing nuts and the plastic face plate and pull the tube free. Disconnect the squeeze tube from the barbs and reconnect the new squeeze tube, making sure that the new squeeze tube is correctly connected to the PVC tubing as per instructions. Reposition the squeeze tube in the unit as before, lubricate the new squeeze tube with the recommended lubricant. Replace the plastic face plate and retaining screws. PLEASE DO NOT OVERTIGHTEN THESE SCREWS OR WING NUTS. USE OF A SUNSCREEN CHEMICAL (CYANURIC ACID) FOR OUTDOOR POOLS IS RECOMMENDED. CHECK WITH YOUR LOCAL POOL SHOP AND USE THE CORRECT DOSAGE. MAKE SURE YOUR POOL WATER IS BALANCED. TROUBLE SHOOTING GUIDE TROUBLE RC1 runs continuously on lower settings of the dial and dispenses excess chemicals It should run continuously on FULL setting The roller Block on the inside of the unit rotates but does not dispense chemicals Water returns to the chemical drum POSSIBLE CAUSE/SOLUTION 1. ECM (Time Switch) faulty 2. ECM needs replacement 1. No chemicals in the tank 2. Tubing in the tank coiled up (must maintain a straight line) 3. Injection point blocked 4. Air leak at the connection where the tube from the drum connects onto the pump (squeeze) tube 5. Chemical container airtight (air must enter container) 6. Non return valve fitted incorrectly (check arrow direction) 7. Roller block broken or worn 8. Pump head cracked 9. Squeeze tube needs replacement. Check points 7, 8 and 9 above. Replace non-return valve, if fitted. If not please fit INST234 RolaChem RC1 Semi - Automatic Controllers V07_14 6

WARRANTY Your Astral Pool RC1 is covered against defects in materials and workmanship from the date of purchase (plus 30 days to allow for installation) for a period of 12 months. The warranty covers infield labour within capital city metropolitan areas or within a 20km radius of an authorized Astral Pool service agent. This warranty is subject to the conditions and limitations listed herein. All warranties apply to the original purchaser of the product and are not transferable to new owners. You must notify Astral Pool upon the failure of any component within the warranty period to make a valid claim. The warranty offered is only valid when the equipment has been used in a normal manner, for the purpose for which it was intended and in accordance with the operating and instruction manual. The replacement of maintenance items used in routine general maintenance are not covered by this warranty. Maintenance items may include (but not limited to); Supply tube Squeeze tube This warranty does not cover any equipment that has been improperly installed, misused, neglected, damaged whether intentionally or accidentally, or repaired/replaced without authorization from Astral Pool or altered in any way from its original form. Extreme operating conditions beyond the control of Astral Pool such as improper power supply, extreme temperatures or other conditions that adversely affect the performance or life of the equipment will void the warranty. Insect infestation or penetration by sand, dust or other foreign bodies will void warranty. Where in field labor warranty is provided, a 20km radius from an authorized Astral Pool agent is applied. If the location of the equipment is outside this area, travel charges will apply. If your request for a service call is deemed to be non warranty, you will be charged for a diagnostic service call. Astral Pool reserve the right to repair or replace defective components or products at its sole discretion. Astral Pool shall have no liability for incidental or consequential damages or delays caused either directly or indirectly by any malfunction of or defect of or failure of the equipment. Where the equipment is installed in commercial situations including (but not limited to) hotels, motels, caravan parks, health clubs, public pools, body corporate installations, etc the warranty is limited to 12 months. Proof of Purchase must be retained for all warranty claims. Warranty will not be considered without Proof of Purchase. No person is authorized to make any representation or warranty on behalf of Astral Pool without express written consent from Astral Pool. INST234 RolaChem RC1 Semi - Automatic Controllers V07_14 7

INSTALLATION AND OPERATING INSTRUCTIONS I INSTALLATION AND OPERATING INSTRUCTIONS INST234 RolaChem RC1 Semi - Automatic Controllers V07_14 8

INST234 RolaChem RC1 Semi - Automatic Controllers V07_14 9