FIELD TIP SHEET. Mark the bag with black permanent marker before filling it with water.

Similar documents
The Maine Healthy (Coastal) Beaches Program: Training Plan for Collecting Water Samples and Recording Environmental Data

Manual Refractometer PCE-ALK

Laboratory practice. Preparation and use of an ice point bath as a reference temperature. Document number TE-LP-001. Version: 07

Density and Stress in Plastics Mary V. McCrary

Part A: 20 minutes plus 30 minutes setting time Part B: day 1, 20 minutes; then 5 minutes each day for about 5 days

Technical Procedure for General Laboratory Equipment

Operating manual Analogue refractometer

Fruit Testing during Long Term Storage

Aseptic Techniques. Techniques for Sterile Compounding. Pharmacy Technician Training Systems Passassured, LLC

EXPERIMENT. Introduction: Microbiology- Rules for Success

INDEX. Specifications 1. Important Safety Precautions 2. Operating Instructions 3, 4. Optional Extras (Meal Tray & Footrest) 5.

Procedure 85 Attaching The Humidifier To The Oxygen Flow Meter Or Regulator. Procedure 86 Administering Oxygen Through A Nasal Cannula

Before you start sampling, be sure to read

Instruction Sheet. Important Note: Information that requires special emphasis. Note: Information that supplements points in the main text.

Ultrasound Compatible Lumbar Puncture/ Epidural Simulator

Operating manual Analogue Brix Refractometer

RayPette Plus Autoclavable Pipette. User Manual

Making a Cartesian Diver Toy

Making a Barometer and Using It

UNCC Biotechnology and Bioinformatics Camp. Dr. Jennifer Weller Summer 2010

The pipettes cover a volume range from 0.1µl to 10ml.

Patients Guide for Self Administering Intravenous Antibiotics General points

R2S Standard Sampling Assembly OPERATION PROCEDURE

Salt Lowers the Freezing Point of Water

Southview Elementary School

MassWWP Standard Operating Procedure R-2 Dissolved Oxygen Rev.0 Page 1 of 10

VOLUMETRIC TECHNIQUES

Instruction Manual. PE-25/32/37 Tapping Machines. POLYTAPP Valves

Abbe 5 Refractometer

Decontamination Procedures for Gilson Pipettes

1.0 PURPOSE The purpose of this procedure is to describe the use of basic aseptic technique.

Pipettor. User Manual

Roy G. Biv Charles W. McLaughlin

SMA1060 INSTRUCTIONS FOR SELF INSPECTION SMA1061 MANUAL INFLATION SMA1062 AUTO INFLATION

Gas Pressure Probe. Information Sheet. Total Dissolved Gas

How Fast Is Your Toy Car?

PARTICLE SPACING PART 1

B. Assemble the Method-25 sample train with a heated probe/filter.

Fiber Optic Lighted Bubbler Spillway Pot (DLP-45) Installation Manual

How Environment-friendly Is Your Home?

Module IV Administration of Medications and Treatments Handouts

ASSEMBLY & USE MANUAL

Instruction Manual Updated 7/26/2011 Ver. 2.2

HOW TO DIG A TEST PIT

Topic Seismographs measure the intensity of earthquakes.

EXPERIMENT 2. Laboratory Procedures INTRODUCTION

State of Nevada Department of Transportation Materials Division METHOD OF TEST FOR DETERMINING THE LIQUID LIMIT OF SOIL

Dissolved Oxygen in Water. Evaluation copy. Table 1. Temperature Range ( C) Trout Smallmouth bass Caddisfly larvae

BOYLE S / CHARLES LAW APPARATUS - 1m long

SMA1500 Instructions for Self Inspection SMA MANUAL INFLATION SMA AUTO INFLATION

Space Dust. Part A: 1 hour Part B: 10 minutes on day 1, 20 minutes on each of several subsequent days

Second Edition Chemistry Experiment Supplies MODULE #1

Standard. Standard. Venepuncture Arm. Light. Part No: Brown. Part No: Black. Part No: 00332

EMT EnvironmentalMonitoringTECHNOLOGIES

ST 18 Aluminium Gas Model

REQUIREMENTS FOR PACKAGING. Wim Renders

Measuring Mass and Volume

PLASTIC FINES IN GRADED AGGREGATES AND SOILS BY THE USE OF THE SAND EQUIVALENT TEST FOP FOR AASHTO T 176 (11)

SALX. Interpretation Guide. Salmonella Express System

How to Weather and Ballast Track

Gas Countertop Griddle

Chemical Spill Clean-up Protocol

Title of Manual: Specimen Collection Document Number: GPA.SPC.45.0

For accurate measurements and to prevent damage to the micropipets, follow these important guidelines:

OxyCheq Expedition-X Oxygen Analyzer. Operator s Manual

VWR UHP j :01 Page 1. ENGLISH 1 22 DEUTSCH FRANÇAIS ESPAπOL ITALIANO

ROCKS, FOSSILS AND SOILS SECTION 5: ENRICHING THE SOIL From Hands on Science by Linda Poore, 2003

Cleaning rod: spring steel, stainless steel or carbon fibre cleaning rod - only use a one-piece rod. Avoid using snakes.

CVC Insertion Simulator

Evergreen Park Elementary School District 124 District School Supply List School Year Kindergarten

APPENDIX A CORRECT USE OF DIGITAL PIPETTES

An Inuit Yo-Yo Sandra J. Walton

WEATHERIZING INSTRUCTIONS

A N B P F G J I C D D L A B C D E F

DuPont Personal Protection Instruction Manual for Universal Pressure Test Kit No

TITLE: Pulse Oximetry COMPETENCY #: Resp #1 NEW COMPETENCY REVISION DATE: 10/18/12 EMPLOYEE NAME. DATE INITIAL RE-EVALUATION ANNUAL (if required) PRN

THE UNIVERSITY OF NEWCASTLE - DISCIPLINE OF MEDICAL BIOCHEMISTRY

MAKE YOUR SAMPLE COUNT! A PRIMER ON COLLECTING QUALITY, REPRESENTATIVE SAMPLES

Adaptations of Desert Plants

INSTALLATION INSTRUCTIONS 1/2 THERMOSTATIC VALVE AND TRIM

MAGNETIC INDOOR CYCLING BIKE

Using a micropipette to transfer exact liquid measurements in scientific experiments By: Nicole Hume

ST 18 Aluminium Gas Model

QUIK-jet Micro-Injection System

Florida s Wildlife Contingency Plan for Oil Spill Response June 2012 Carcass Collection Protocols. Carcass Collection Protocols

For accurate measurements and to prevent damage to the micropipets, follow these important guidelines:

3M Liqui-Cel EXF-10x28 Series Membrane Contactor

QUALITY ASSURANCE HATCHERY

The Outer Seal is highly abrasion resistant and provides mechanical stiffness to the splice in order to better match the cable stiffness.

OPERATOR S MANUAL Ar-Gone Weld Gas Analyzer

3M Liqui-Cel EXF-10x28 Series Membrane Contactor with ANSI or JIS Connections with Integrated End Caps

P5513. Users Manual. Pneumatic Comparison Test Pump. Test Equipment Depot Washington Street Melrose, MA TestEquipmentDepot.

YSI Model 550a Dissolved Oxygen (DO) Meter

Emergency Shower & Eyewash. Training Guide

The Surge of the Storm By Margaret Olsen and Katie Greganti

PRODUCT SHEET. Order probe only as RXPROBE02

ROHO QUADTRO SELECT CUSHION ADJUSTMENT INSTRUCTIONS

FILTER REGULATORS MODEL NO: CAT155 & CAT156 FITTING & MAINTENANCE INSTRUCTIONS PART NO: & ORIGINAL INSTRUCTIONS

BELT DRIVE INDOOR CYCLING BIKE SF-B1712 USER MANUAL

Standard Operating Procedure for Zooplankton Sample Collection and Preservation

Transcription:

Maine Healthy Beaches Program Field Methods Esperanza Stancioff March 2007

FIELD TIP SHEET When taking a sample, be sure to: Mark the bag with black permanent marker before filling it with water. Mark the bag with the sample site number (OOB-1), DATE and TIME (military) only. See example below. Look around at each station and record observations that could affect water quality. (For example: 25 gulls, 3 seals, seasonal cottage occupied, heavy runoff in stream in cove to north.) Be very careful not to contaminate the bag by opening it too early. Do not touch the bag near the perforated opening. Wade into water to 3 feet of depth, or at the level you see people in the water. Sample water 6-8 inches below the surface. Fill the bag two-thirds full. Keep samples upright in the cooler. (Cooler temperature between 4 and 10 C). Be sure samples are not touching the ice directly! --------------------------------------- SAMPLE SITE # DATE TIME OOB-1 08/01/07 1015 Remember to calibrate refractometer with distilled water and dry with kimwipe before reading salinity Remember to record air and water temperatures Remember to bring cooler down to water s edge!

FIELD PROCEDURES 1 List of Equipment ~ Whirlpak bags (sterile bags) ~ Sample tongs ~ Digital Thermometer ~ Permanent markers ~ Plastic pipette ~ Distilled water in 125 ml squirt bottle ~ Kimwipes in zip lock bag (refractometer) ~ Clipboard with datasheets, sample sites map, and field tip sheet (should have a plastic cover for these to protect them in inclement weather or laminate tip sheet and tape to back of clipboard. ~ Pencil (soft pencils will write on damp surfaces) and indelible pen. ~ Cooler and ice packs (3-4 blue ice packs more may be needed in hot weather) ~ Hand-held Refractometer ~ Tray or cut-off gallon jug to separate samples when appropriate ~ MHB field equipment bag

2. Sample Collection and Transport Monitoring of coastal sites should be conducted weekly. Tuesdays, Wednesdays or Thursdays work well since the results would be back to the beach manager just before the weekend when usage is highest. The following procedures are for taking a water sample that will be analyzed for bacteria content. In the case of beach monitoring the indicator being monitored is Enterococci. All sampling personnel should be aware of the concept of aseptic technique and the integrity of sterile systems. It is imperative, especially under primitive field conditions, that precautions are taken against bacterial contamination or cross-contamination of containers or samples. Safety is of utmost concern! Use good safety practices, and when in doubt, do not ever risk personal safety for sample collection. Consider wearing a personal floatation device (pfd). This is especially important while wearing waders, as they may fill up and pose a risk. Do not touch eyes and mouth during and after sample collection and be sure to wash your hands. Consider wearing gloves while monitoring areas with high bacteria levels. Working in pairs is recommended for safety, efficiency and quality control. STEP 1 At the beginning of sample collection, record the sample site number, time, and date on the environmental datasheet. STEP 2 Record air temperature in degrees Celsius while the thermometer is still dry. Be sure the probe isn t touching anything, and is in the shade or out of direct sunlight for one to two minute before reading. Tidal stage should be recorded (indicate falling or rising tidal stage if possible), as well as present weather conditions and previous weather conditions. (See field Tip Sheet). STEP 2 Collect water samples for bacterial examination in sterile plastic container, such as whirlpak bags. Protection against contamination of the sample and container before, during, and after collection is extremely important. Sterile bags or bottles must first be labeled on the bottom third of the bag starting with the area letter for your beach sample site number, date, and (military) time. STEP 3 Wade into the water, being careful not to disturb the bottom, to a 3 ft depth to take measurements and to collect the sample. Take the water temperature at each site

at a depth of 6 to 8 inches by holding the thermometer in the water 1-2 minutes before reading the value. STEP 4 Samples should be collected with the aid of sampling tongs. Keep the sample container closed until immediately before filling. During sampling, protect the container closure from contamination. To collect the sample, hold the bag with one hand and place the alligator clips of the sample tongs on the white tabs (Hint: located on side of bag, not yellow, paper-covered wires used to close bag) with the other hand. Try to position alligator clips on tabs at the smallest end (strongest end) of the clips. Also take care to keep the spring-loaded tongs together while placing the clips on the tabs. Tear off top of bag at the perforation, taking care not to touch the opening. Squeeze tongs together and plunge bag below the surface 6 to 8 inches. Then tilt it with bag open and pointed toward current. Before bringing the bag to the surface, close the opening by squeezing the tongs together. To facilitate shaking the sample in the laboratory, fill only two thirds full. Carefully pour or flip out any excess water so that an air space will remain in the two-thirds full bag of water. STEP 5 Twirl the bag away from you, holding the ends, and then twist the yellow papercovered wire closures together over the top of the bag. Samples are then placed upright in the cooler, containing ice or ice pack(s), which should be kept between 4-10 C. During the hot summer months place several ice paks in the cooler prior to sampling, assuring that the temperature in the cooler is 4-10 degrees C. (Plastic quart or gallon milk jugs cut in half make good containers for keeping the samples in place and upright.) Only sample bags and ice packs should be transported in the cooler. All other equipment should be stored in the MHB bag or another container. STEP 7 Record the water temperature on data sheet. Be sure to complete the data sheet as each sample is taken: sample number, temperature, time, salinity, time of tide, weather conditions and any observations that might relate to water quality (e.g. flooding, 10 seals on rocks, oil on surface of water, rotten egg odor, etc.) (See codes on back of field datasheet) 3. Salinity Using a Hand-Held Refractometer These instruments are fairly easy to use.

STEP 1 To calibrate using distilled water, adjust the boundary line to read at the o o/oo of the scale by turning the scale-adjusting knob. This diagram is reversed. The instrument has Salinity on the right-hand side. STEP 2 Open the daylight plate and apply one or two drops of a sample solution on the prism surface. STEP 3 Close the daylight plate gently. The sample solution spreads like a thin film between the daylight plate and the prism. Make sure there are no bubbles in the sample solution. STEP 4 Hold the refractometer with the daylight plate upward, direct it toward the light, and observe the field of view through the eyepiece. When the field of view is not clear, adjust it by turning the grooved plastic portion of the eyepiece either clockwise or counter clockwise. Salinity is read in parts per thousand or 0/00. STEP 5 The upper field of view appears in blue and the lower field of view appears in white. Read the scale where the boundary line of the blue and white fields cross the scale. The value read on the right hand scale (in parts per thousand) is the salinity of the sample. STEP 6 Clean the refractometer after use with a soft cloth soaked in fresh water and wipe off the moisture with a dry cloth. If the prism surface is smeared with oil or similar liquids, it will repel the sample and obstruct the measurement. Wipe off the contaminant with alcohol, then with fresh water. NOTE: You can adjust for your eyesight by twisting the black ring near the eyepiece. 4. Chain of Custody-These measures are to ensure the safe transport and integrity of the collected samples. Record cooler temperature, and wait one to two minutes

before reading. DO NOT crush the thermometer cable between the lid and cooler lip. Record date, time and signature at the bottom of the datasheet. 5. Environmental Data-Transfer all the data recorded on the field datasheet into the MHB Program Database by the end of the scheduled sampling day. Have this verified by another colleague for accuracy when possible. Methods adapted from: Stancioff, Esperanza. Clean Water: A Manual for Coastal Water Quality Monitoring, published by the University of Maine Sea Grant, 1992, revised 1996