Radiation-based Overview Page 214 FIBERTRAC Page 216 SOLITRAC Page 218 MINITRAC Page 220 POINTRAC Page 222 WEIGHTRAC Page 224

Similar documents
Radiation-based. 166 Overview PROTRAC 170 FIBERTRAC SOLITRAC POINTRAC MINITRAC WEIGHTRAC VEGASOURCE 31, 35

Ultrasonic. Continuous level measurement. Overview Page 64 VEGASON series 60 Page 66 AL-EN

Ultrasonic. 58 Overview VEGASON 60 VEGASON 61, 62, 63

Hydrostatic. Continuous level measurement. Overview Page 188 VEGAWELL 52 Page 190 VEGABAR 86, 87 Page 192 Accessory Page 196 AL-EN

Differential pressure

TDR Guided Wave Radar

Level, Pressure, and Density Instrumentation for the Petrochemical Industry

Product information. Capacitive. Level detection with bulk solids VEGACAP 62 VEGACAP 65 VEGACAP 66 VEGACAP 67. Document ID: 29982

Product information. Capacitive. Level detection in liquid VEGACAP 62 VEGACAP 63 VEGACAP 64 VEGACAP 66 VEGACAP 69. Document ID: 29983

Torque Tube TB300 Digital Transmitters

Product information. Capacitive. Level measurement in liquid VEGACAL 62 VEGACAL 63 VEGACAL 64 VEGACAL 66 VEGACAL 69. Document ID: 30138

SITRANS P measuring instruments for pressure

Product information Vibrating

1 Overview. Pressure Measurement Single-range transmitters for general applications. 1/22 Siemens FI

1 Overview. Pressure Measurement Single-range transmitters for general applications. 1/22 Siemens FI US Edition

Electropneumatic Positioner Type 4763 Pneumatic Positioner Type 4765

Pressure Measurement Single-range transmitters for general applications

1 Overview. Pressure Measurement Transmitters for basic requirements. 1/16 Siemens FI SITRANS P220 for gauge pressure

How to specify a product. Process Sensors and Mechanical Instruments

Pressure measurement is a family affair

Certified according to DIN EN ISO 9001 Technical Datasheet TRICOR Series Mass Flow Meters

Series INTELLIGENT PRESSURE- AND LEVEL TRANSMITTERS For all industries. Description ALL STAINLESS DESIGN

Level transmitter LT 100

User s Manual EJX/EJA-E Series NEPSI Certification [Option code: /NF2, /NS21, /NS24 and /NS25] IM 01C25A00-12E

Pressure Measurement. Transmitters for basic requirements SITRANS P Z for gauge pressure. 2/4 Siemens FI Overview

ATM.1ST/Ex - High Precision Transmitter

Technical Datasheet. D Series SMART Pressure Transmitter Model: DPC D-Series. Key Features. Series Overview. Product applications

Series INTELLIGENT PRESSURE- AND LEVEL TRANSMITTERS For all industries. Description ALL STAINLESS DESIGN

Pressure measurement is a family affair

Two-Wire In Situ Oxygen Analyzer (550 to 1400 C)

TYPE APPROVAL CERTIFICATE

Flow metering in gases Introduction to COMBIMASS family

1 Overview. Pressure Measurement Single-range transmitters for general applications. 1/16 Siemens FI US Edition

Flow Measurement SITRANS F C

Petrochemical Industry

A Higher Level of Performance. Data Sheet. Series Pressure and Level Transmitters. For more information, please visit >

L (up to 25 m) Electronic part. working temp.: Ñ IP 66 / IP67. Mounting bracket ÐÑ. Sensor type. working temp.:

VG5 Supplementary instructions

2 Overview. SITRANS P measuring instruments for pressure. Transmitters for gage and absolute pressure. Z series for gage pressure

Technical Data. General specifications Switching element function DC Dual NC Rated operating distance s n 3 mm. Short-circuit protection

Bourdon tube pressure gauge for diaphragm seals

ELECTRIC ACTUATORS for continuous underwater use

Electropneumatic Positioner and Pneumatic Positioner Type 3760 JIS

LMP 307. Stainless Steel Probe. Stainless Steel Sensor. accuracy according to IEC 60770: standard: 0.35 % FSO option: 0.25 % / 0.

Brief Operating Instructions Gammapilot M FMG60

Smart performance with innovative and ever-strong coil drive even under harsh working environments

Expert Hydrostatic Level Transmitters

Pressure Measurement Single-range transmitters for general applications

JUMO dtrans O2 01 Two-wire Transmitter for dissolved oxygen (DO)

better measurement Simply a question of SCHMIDT Flow Sensor SS The cost-effective alternative in pressurised systems up to 10 bars.

Magnetic level switch type MR783 Instruction Manual

Compact differential pressure switch Flameproof enclosure Ex d Models DE, DEC

ATM.ECO/IS - Analog Transmitter with Temperature compensation

Pressure Measurement Single-range transmitters for general applications

FAS-W. Features. Applications. Automatic condensation hygrometer

Micro Motion 3098 Gas Specific Gravity Meter

Safety Instructions Liquiphant FailSafe FTL80, FTL81, FTL85

Level MEASUREMENT 1/2016

Siemens AG psi (6 bar) 145 psi (10 bar) 464 psi (32 bar) 1450 psi (100 bar) 3626 psi (250 bar) 8700 psi (600 bar) psi (800 bar)

NivuBar Plus II

VersaFlow Vortex 100 Vortex Flow Meter Technical Datasheet. Specification. The all-in-one solution. Highlights. Industries.

Liquid level switch BM 34

ATM/Ex - Analog Pressure Transmitter

UHrasonic Sensor VEGASON60 type series SN6*.CI**H***

ATM/Ex - Intrinsically Safe Analog Pressure Transmitter - ATEX / IECEx Certified

Pressure transmitter PASCAL Ci4

TF- & DM-Series. Turbineflowmeter

Dimensions. Technical Data General specifications Switching element function DC Dual NC Rated operating distance s n 3 mm

Miniature flowmeters DK 46, DKR 46 DK 47, DK 48, DK 800

C-Flow Coriolis Mass Flow Meters

Reliable, low-maintenance pressure measurement with SITRANS P

OPTIBAR P 1010 C Technical Datasheet

Level measurement. Continuous level measurement Guided wave radar transmitters. SITRANS LG series. 4/208 Siemens FI

Pressure Transmitters 36 F-27839

Point Level Measurement. Switching Technology for Liquid and Solid Level Measurement

Level detection in bulk solids. Vibration VEGAVIB VEGAWAVE Product Information

Oxymax W COS51D. Technical Information. Digital sensor for measuring dissolved oxygen Membrane-covered amperometric sensor

Technical Data. Dimensions

OSAT Series. Intrinsically Safe Infrared Temperature Sensor Operator's Guide

DPZ-plus. Application example. Pneumatic 3-Finger Centric Grippers Sealed Grippers. Gripping force 520 N N. Sizes

SPD310/SPD360 Air Differential

Pro-V Multivariable Flowmeter Model M22 In-line Vortex

Level transmitters and indicators Series LU Ultrasonic level transmitter and indicator for liquids and solids

Ultrasonic level transmitter and indicator

TGD-L (LP) Tank Gauging Device TGD L (Level) TGD LP (Level Pressure) Main features:

dtrans O2 01 Two-wire Transmitter for dissolved oxygen (DO)

ATEX VACUUM PUMPS AND GAUGES CHEMICALLY RESISTANT, OIL-FREE AND SAFE

DMK 458. Pressure Transmitter for Marine and Offshore. Ceramic Sensor. accuracy according to IEC 60770: standard: 0.25 % FSO option: 0.

Level switches Series LD Vibrating fork level switch for liquids and solids

Liquid level instruments BM 24 /BM 51

Operating Instructions VEGAPULS 66

For the highest operational safety around the clock

better measurement Simply a question of

EX-RECESSED CEILING LIGHT FITTINGS

Flow Measurement SITRANS F X

High-performance submersible pressure transmitter For level measurement Model LH-10

IDL01. Battery Powered Precision Digital Gauge for Leak Testing. Stainless Steel Sensor. class 0.05

Gripping modules Pneumatic 2-finger parallel gripper Long-stroke gripper for small components Gripping force 120 N..

Electropneumatic Positioner and Pneumatic Positioner Type 3760 JIS

FLAMMABLE GAS SENSOR/TRANSMITTER

Transcription:

Detectors Radiation-based Overview Page 214 FIBERTRAC Page 216 SOLITRAC Page 218 MINITRAC Page 220 POINTRAC Page 222 WEIGHTRAC Page 224 213

FIBERTRAC, SOLITRAC, MINITRAC, POINTRAC, WEIGHTRAC Radiation-based sensors for level, density and mass flow measurement Measuring principle In the radiation-based measurement, a Caesium 137 or Cobalt 60 isotope emits focused gamma rays. A special sensor located at the opposite side of the vessel receives this radiation. The so called scintillator converts the gamma rays into signals, their number is detected and processed. Because gamma rays are damped when penetrating the substance, the sensor can calculate the level, the limit level, the density or the mass flow out of the received radiation. Applications Level measurement With FIBERTRAC and SOLITRAC level changes are contactlessly measured through the vessel wall. Since the measuring facility is mounted on the outside of the vessel, the measurement is insensitive to extreme process conditions. Also measurements on pressurized vessels or on vessels with agitators can be simply realized. For round vessel forms the flexible FIBERTRAC is recommended, which can be simply mounted on the vessel. A high reliability can be reached with SOLITRAC on cylindrical vessels. The sensors are cascadable for very large measuring ranges. Density measurement The non-contact, continuous density and concentration measurement of liquids and bulk solids with MINITRAC is suitable for pipelines and vessels. The measuring principle is independent of aggressive products and ensures a high reliablity. The sensor mounting is carried out on existing pipelines. With small tube diameters an inclined radiation or the use of a measuring track is recommended. In case there is also a temperature sensor connected, then MINITRAC takes the heat expansion of the medium into account. Furthermore the mass flow of MINITRAC can be calculated with the signal of a flow volume measuring instrument. This ensures reliable measurement results and permanent process continuity even with extreme process conditions. Flow measurement The WEIGHTRAC determines contactlessly the exact delivery volume of solids. Through the frame construction, the sensor can be simply mounted to the conveyor belt. The measurement runs wear and maintenance-free. A simple and reliable adjustment of the sensor saves time during setup. The WEIGHTRAC is suitable for conveyor systems, for example conveyor belt weighers, screw conveyors, chain trough conveyors, steel plate conveyors, bucket conveyors. 214 Radiation-based PROTRAC

Overview Instrument type Version Measuring range Process fitting Reproducibility FIBERTRAC 31 Sensor with flexible plastic detector ø 42 mm up to 7 m From outside on the vessel ± 0.5 % SOLITRAC 31 Sensor with PVT rod detector up to 3 m From outside on the vessel ± 0.5 % MINITRAC 31 Sensor with integrated NaI detector --- From outside on the vessel or on pipelines ± 0.1 % POINTRAC 31 Sensor with PVT rod detector up to 305 mm From outside on the vessel or on pipelines --- WEIGHTRAC 31 Sensor with PVT rod detector up to 1600 mm Through supplied measuring frame ± 1 % of measuring range final value Radiation-based Radiation-based PROTRAC 215

FIBERTRAC 31 Radiation-based sensor for continuous level and interface measurement Application area The FIBERTRAC 31 is a radiation-based sensor for continuous measurement of liquids and bulk solids. It is suitable for level and interface measurement under extreme process conditions, in aggressive products or critical product features. The FIBERTRAC 31 delivers precise measuring results even under hardest application conditions. Your benefit High plant availability through non-contact measurement Simple mounting on round and conical vessels through flexible detector Cost saving through use of only one sensor up to 7 m measuring range Technical data Version: sensor with flexible plastic detector ø 42 mm Measuring range: up to 7 m Mounting: from outside on the vessel Reproducibility: +/- 0.5 % SIL qualification: optionally up to SIL2 ø 85,7 mm (3.37") 61,4 mm (2.42") 111,5 mm (4.39") L Measuring length 180 mm (7.09") 291 mm (11.46") 143,6 mm (5.65") 50 mm (1.97") L ø 42 mm (1.58") You will find further process fittings and options under www.vega.com/configurator. You will find further drawings and tables under www.vega.com/downloads. You will find mounting accessory, welded sockets and housing overviews in chapter "Accessory". 216 Radiation-based FIBERTRAC 31

Approval XX Without... DK ATEX II 2G Ex d ia IIC T6+1D,2D Ex td IP66 T... TX ATEX IM 2 (M1) Ex d [ia Ma] I Mb... DK IEC Zone 1 Ex d ia IIC T6+Ex td A20,A21 IP66 T... TX IEC Ex d [ia Ma]I Mb... Version / Ambient temperature 1 Standard / -20º...+50ºC... Electronics V Four-wire 4...20mA/HART... S Four-wire 4...20mA/HART with SIL qualification... A Four-wire 4...20 ma/hart (Explosion Proof Output)... I Four-wire 4...20 ma/hart (Explosion Proof Output) SIL... L Four-wire 4...20 ma/hart (Intrinsic. Safe Output) SIL... F Four-wire Foundation Fieldbus... C Four-wire Foundation Fieldbus (Explosion Proof Output)... P Four-wire Profibus PA... E Four-wire Profibus PA (Explosion Proof Output)... Housing / Protection D Aluminum / IP66/IP67... W 316L SS / IP66/IP67... Cable entry / Cable gland / Plug connection M M20x1.5 / with / without... N 1/2 NPT / without / without... Indicating / Adjustment module (PLICSCOM) X Without... B Side mounted with backlight... Additional equipment X without... Active length A10 1000 mm... A15 1500 mm... A20 2000 mm... A25 2500 mm... A30 3000 mm... A35 3500 mm... A40 4000 mm... A45 4500 mm... A50 5000 mm... A55 5500 mm... A60 6000 mm... A65 6500 mm... A70 7000 mm... Radiation-based FT31. Radiation-based FIBERTRAC 31 217

SOLITRAC 31 Radiation-based sensor for continuous level and interface measurement Application area The SOLITRAC 31 is a radiation-based sensor with PVT rod detector for continuous measurement of liquids and bulk solids. It is suitable for level and interface measurement under extreme process conditions, with critical product features or in aggressive products. The SOLITRAC 31 is ideal for use in cylindircal vessels, reactors, autoclaves, separators and mixing vessels. Your benefit High plant availability through non-contact measurement Best measurement performance through PVT detector with maximum sensitivity Simple mounting through supplied accessory Technical data Version: sensor with PVT rod detector Measuring range: up to 3 m Mounting: from outside on the vessel Reproducibility: +/- 0.5 % SIL qualification: optionally up to SIL2 ø 85,7 mm (3.37") 61,4 mm (2.42") 111,5 mm (4.39") L Measuring length 143,6 mm (5.65") ø 76,2 mm (3") 36 mm (1.42") L 180 mm (7.09") 256 mm (10.08") You will find further process fittings and options under www.vega.com/configurator. You will find further drawings and tables under www.vega.com/downloads. You will find mounting accessory, welded sockets and housing overviews in chapter "Accessory". 218 Radiation-based SOLITRAC 31

ST31. Approval XX Without... DK ATEX II 2G Ex d ia IIC T6+1D,2D Ex td IP66 T... TX ATEX IM 2 (M1) Ex d [ia Ma] I Mb... DK IEC Zone 1 Ex d ia IIC T6+Ex td A20,A21 IP66 T... TX IEC Ex d [ia Ma]I Mb... Version / Ambient temperature 1 Standard / -40º...+60ºC... Electronics V Four-wire 4...20mA/HART... S Four-wire 4...20mA/HART with SIL qualification... A Four-wire 4...20 ma/hart (Explosion Proof Output)... I Four-wire 4...20 ma/hart (Explosion Proof Output) SIL... L Four-wire 4...20 ma/hart (Intrinsic. Safe Output) SIL... F Four-wire Foundation Fieldbus... C Four-wire Foundation Fieldbus (Explosion Proof Output)... P Four-wire Profibus PA... E Four-wire Profibus PA (Explosion Proof Output)... Housing / Protection D Aluminum / IP66/IP67... W 316L SS / IP66/IP67... Cable entry / Cable gland / Plug connection M M20x1.5 / with / without... N 1/2 NPT / without / without... Indicating / Adjustment module (PLICSCOM) X Without... B Side mounted with backlight... Additional equipment X without... Length A05 500 mm... A10 1000 mm... A15 1500 mm... A20 2000 mm... A25 2500 mm... A30 3000 mm... Radiation-based Radiation-based SOLITRAC 31 219

MINITRAC 31 Radiation-based sensor for density measurement Application area The MINITRAC 31 is a radiation-based sensor for non-contact density measurement of liquids and bulk solids. The MINITRAC 31 determines the density contactlessly from outside through pipelines or the vessel wall. Through its compact design it is ideal for mounting in positions hardly to access and in narrow space applications. Your benefit Simple retrofitting during production processes High plant availability through non-contact measurement Exact measuring results independent of the process conditions Technical data Version: sensor with integrated NaI detector Mounting: from outside on pipelines or the vessel Reproducibility: +/- 0.1 % SIL qualification: optionally up to SIL2 ø 85,7 mm (3.37") 61,4 mm (2.42") 111,5 mm (4.39") 180 mm (7.09") 291 mm (11.46") 143,6 mm (5.65") You will find further process fittings and options under www.vega.com/configurator. You will find further drawings and tables under www.vega.com/downloads. You will find mounting accessory, welded sockets and housing overviews in chapter "Accessory". 220 Radiation-based MINITRAC 31

Approval XX Without... DK ATEX II 2G Ex d ia IIC T6+1D,2D Ex td IP66 T... TX ATEX IM 2 (M1) Ex d [ia Ma] I Mb... DK IEC Zone 1 Ex d ia IIC T6+Ex td A20,A21 IP66 T... TX IEC Ex d [ia Ma]I Mb... Version / Ambient temperature 1 Standard / -40º...+60ºC... Electronics V Four-wire 4...20mA/HART... S Four-wire 4...20mA/HART with SIL qualification... A Four-wire 4...20 ma/hart (Explosion Proof Output)... I Four-wire 4...20 ma/hart (Explosion Proof Output) SIL... L Four-wire 4...20 ma/hart (Intrinsic. Safe Output) SIL... F Four-wire Foundation Fieldbus... C Four-wire Foundation Fieldbus (Explosion Proof Output)... P Four-wire Profibus PA... E Four-wire Profibus PA (Explosion Proof Output)... Housing / Protection D Aluminum / IP66/IP67... W 316L SS / IP66/IP67... Cable entry / Cable gland / Plug connection M M20x1.5 / with / without... N 1/2 NPT / without / without... Indicating / Adjustment module (PLICSCOM) X Without... B Side mounted with backlight... Additional equipment X without... S Int. lead coating to protect against ambient radiation... MT31. Radiation-based Radiation-based MINITRAC 31 221

POINTRAC 31 Radiation-based sensor for level detection Application area The POINTRAC 31 is a radiation-based sensor for universal level detection of liquids and bulk solids. Independent of the mounting location, it monitors reliably the limit level in vessels. The sensor can be used for applications in all industries. Due to the high sensitivity POINTRAC 31 is an economical solution with minimum radiation activity. Your benefit Exact measuring results independent of process conditions High process reliability through determination of buildup Economical level detection under arduous application conditions Technical data Version: Measuring range: Mounting: SIL qualification: sensor with PVT rod detector up to 305 mm from outside on the pipeline or vessel optionally up to SIL2 ø 85,7 mm (3.37") 61,4 mm (2.42") 111,5 mm (4.39") 143,6 mm (5.65") ø 76,2 mm (3") 36 mm (1.42") 180 mm (7.09") L 256 mm (10.08") You will find further process fittings and options under www.vega.com/configurator. You will find further drawings and tables under www.vega.com/downloads. You will find mounting accessory, welded sockets and housing overviews in chapter "Accessory". 222 Radiation-based POINTRAC 31

PT31. Approval XX Without... DK ATEX II 2G Ex d ia IIC T6+1D,2D Ex td IP66 T... TX ATEX IM 2 (M1) Ex d [ia Ma] I Mb... DK IEC Zone 1 Ex d ia IIC T6+Ex td A20,A21 IP66 T... TX IEC Ex d [ia Ma]I Mb... Version / Ambient temperature 1 Standard / -40º...+60ºC... Electronics V Four-wire 8/16 ma/hart... S Four-wire 8/16 ma/hart with SIL qualification... A Four-wire 8/16 ma/hart (Ex d output)... I Four-wire 8/16 ma/hart (Ex d output) w. SIL qualif.... L Four-wire 8/16 ma/hart (Ex ia output) w. SIL qualif.... F Four-wire Foundation Fieldbus... C 4-wire Foundation Fieldbus (Explosion Proof Output)... P Four-wire Profibus PA... E 4-wire Profibus PA (Explosion Proof Output)... Housing / Protection D Aluminum / IP66/IP67... W 316L SS / IP66/IP67... Cable entry / Cable gland / Plug connection M M20x1.5 / with / without... N 1/2 NPT / without / without... Indicating / Adjustment Module (PLICSCOM) X Without... B Side mounted with backlight... Additional equipment X without... Length 006 152 mm... 012 305 mm... Radiation-based Radiation-based POINTRAC 31 223

WEIGHTRAC 31 Radiation-based sensor for mass flow determination Application area The WEIGHTRAC 31 is a radiation-based sensor for precise flow measurement of bulk solids. It is ideal for mass flow determination on conveyor belts and in conveyor spirals in all industries. Due to its frame construction, the WEIGHTRAC 31 can be simply retrofitted on the conveyor belt. Your benefit Wear-free, because non-contact measurement Exact determination of the delivery volume through simple setup Technical data Version: Measurement width: Mounting: Accuracy: sensor with PVT rod detector up to 1600 mm through the supplied measurement frame +/- 1 % of the measuring range final value B 30 mm (1.81") 30 mm (1.81") Note: Source container not in the scope of delivery A E D 136 mm (5.35") 70 mm (2.76") 122 mm (4.80") C 70 mm (2.76") You will find further process fittings and options under www.vega.com/configurator. You will find further drawings and tables under www.vega.com/downloads. You will find mounting accessory, welded sockets and housing overviews in chapter "Accessory". 224 Radiation-based WEIGHTRAC 31

WT31. Approval XX Without... DK ATEX II 2G Ex d ia IIC T6+1D,2D Ex td IP66 T... TX ATEX IM 2 (M1) Ex d [ia Ma] I Mb... DK IEC Zone 1 Ex d ia IIC T6+Ex td A20,A21 IP66 T... TX IEC Ex d [ia Ma]I Mb... Version / Ambient temperature 1 Standard / -40º...+60ºC... Electronics V Four-wire 4...20mA/HART... A Four-wire 4...20 ma/hart (Explosion Proof Output)... F Four-wire Foundation Fieldbus... C Four-wire Foundation Fieldbus (Explosion Proof Output)... P Four-wire Profibus PA... E Four-wire Profibus PA (Explosion Proof Output)... Housing / Protection D Aluminum / IP66/IP67... W 316L SS / IP66/IP67... Cable entry / Cable gland / Plug connection M M20x1.5 / with / without... N 1/2 NPT / without / without... Indicating / Adjustment module (PLICSCOM) X Without... B Side mounted with backlight... Additional equipment X without... Frame construction A LCS w/epoxy Powder Coating... C 316L SS... Conveyor width (A) N1 500 mm... P1 800 mm... Q1 1000 mm... R1 1200 mm... S1 1600 mm... Source holder configuration B Single SHLD-1 mounting plate... D Dual SHLD-1 mounting plates... Radiation-based Radiation-based WEIGHTRAC 31 225

226 Radiation-based