Shut-off Liquid level and regulating valves for for Industrial Refrigeration

Similar documents
Liquid level regulating valves Types PMFL / PMFH and SV

Float valves Types SV 4, SV 5 and SV 6

Modulating liquid level regulators, servo-controlled PMFL / PMFH and SV

Float valves Types SV 1 and SV 3

Modulating liquid level regulators, direct-controlled, type SV 1 and 3 REFRIGERATION AND AIR CONDITIONING. Technical leaflet

2-step solenoid valve Type ICLX

2-step solenoid valve Type ICLX

Solenoid valves, two-step on/off Type PMLX REFRIGERATION AND AIR CONDITIONING. Technical leaflet

Pressure regulating valves Types OFV, OFV-SS

for for Industrial Refrigeration

Overflow valves Type OFV Type OFV-SS REFRIGERATION AND AIR CONDITIONING. Technical leaflet

Safety relief valves Type SFV 20-25

Dual position solenoid valve Type ICSH 25-80

Safety relief valves SFV 20-25

Solenoid Valves, one - or two step, on/off ICLX

Safety relief valves Type SFA 15 and SFA 15-50

Overflow valves Type OFV REFRIGERATION AND AIR CONDITIONING. Technical leaflet

Regulating valves Type REG 6-65 Type REG-SS REFRIGERATION AND AIR CONDITIONING. Technical leaflet

Safety relief valves, type SFA 15 REFRIGERATION AND AIR CONDITIONING. Technical leaflet

Hand-operated regulating valves in stainless steel Types REG-SA SS and REG-SB SS

Regulating valves REG-SA and REG-SB

Gas powered stop valves, type GPLX REFRIGERATION AND AIR CONDITIONING. Technical leaflet

Safety relief valves, type SFA 15

MAKING MODERN LIVING POSSIBLE. Pilot operated internal safety valves type POV REFRIGERATION AND AIR CONDITIONING DIVISION.

Safety relief valves Type BSV-8

Hand operated regulating valves Types REG-SA and REG-SB

Pilot valves for pilot operated servo valves

Safety relief valves, type BSV 8 REFRIGERATION AND AIR CONDITIONING. Technical leaflet

Shut-off valve Type QDV

Water valve Type WVO. Data sheet MAKING MODERN LIVING POSSIBLE

Evaporator pressure regulator Type KVP

Valve station ICF 15, ICF 20, ICF 25, ICF 50 and ICF 65

Solenoid valve type EVR for Hydrocarbons

Condensing pressure regulator, type KVR Differential pressure valve, type NRD

Liquid level glasses, type LLG REFRIGERATION AND AIR CONDITIONING. Technical leaflet

Crankcase pressure regulator, type KVL REFRIGERATION AND AIR CONDITIONING. Technical leaflet

Reliable System Performance PM valves

Capacities Valve Station, type ICF 15, 20, 25

Quick closing oil drain valve, type QDV 15 REFRIGERATION AND AIR CONDITIONING. Technical leaflet

Condensing pressure regulator, type KVR Receiver pressure regulator, type NRD

Capacity regulator (hot gas bypass)

Evaporator pressure regulator Type KVP

Capacity regulator (hot gas bypass), type TUH/TCHE/TRHE REFRIGERATION AND AIR CONDITIONING. Technical leaflet

Instructions. Control Solution ICF 20-4, ICF 25-4, ICF ICF 40-4, ICF 20-6, ICF 25-6, ICF 32-6, ICF 40-6, Direction and Position.

Selection of ICF made easy Save even more time with ICF

Instructions. Control Solution ICF 20-4, ICF 25-4, ICF ICF 40-4, ICF 20-6, ICF 25-6, ICF 32-6, ICF 40-6, Direction and position.

Pressure reduction controller (PN 16, 25, 40)

Automatic Balancing Valve Pressure difference controller with integrated flow limiter AB-PM DN

CHECK VALVES APPLICATIONS

Valve Station ICF 15, 20 and 25

Electric expansion valves Types AKV 10, AKV 15 and AKV 20

Ball Float Steam Trap UNA 45 MAX, UNA 46 MAX, UNA 46A MAX PN 40/Class 300 DN 40, 50, 65

Differential pressure controller (PN 25) AVP - return and flow mounting, adjustable setting

Technical leaflet. Pressure and Temperature Regulators. January 1999 RC.4X.B1.22. Danfoss A/S

Pressure reducing valves Index

Evaporating Pressure Regulating Valve Type KVQ REFRIGERATION AND AIR CONDITIONING. Technical leaflet

for Building facilities Industrial facilities etc.,multipurpose Pilot operated type(high capacity)

USM21 Sealed Bimetallic Steam Trap for use with Pipeline Connectors Installation and Maintenance Instructions

PRESSURE REDUCING VALVE RP45 (EN)

Ball Float Steam Trap UNA 43 PN 16/CL 125/JIS 10K UNA 46 PN 40/CL 150/CL 300/JIS 10K/JIS 20K DN 80, 100, 150, 3", 4", 6"

Electric regulating valves Type CCMT 2 - CCMT 8 / CCMT 16 - CCMT 42

Pressure and/or Temperature Pilot Operated Steam Regulators Series 2000

756 Safety Relief Valves

Differential pressure and flow controller (PN 16) AVPQ - return mounting, adjustable setting

Differential pressure controller (PN 16) AVPL return mounting, adjustable setting

TECHNICAL DATA. Page 1 of 12

HANDBOOK SAFETY DEVICES. Ed SAFETY DEVICES DS-ED 01/ ENG 1

PRESSURE REDUCING VALVE RP45 (ANSI)

Mounting and Operating Instructions EB 3007 EN. Self-operated Pressure Regulators. Differential Pressure Regulators (opening) Type Type 42-25

Differential pressure controller (PN 16) AHP - return mounting, adjustable setting

776 Cryogenic Safety Valve

HANDBOOK SAFETY DEVICES. Ed SAFETY DEVICES DS-ED 01/ ENG 1

AVP-F. p setting range (bar) Code No. 003H6200

SV5 Safety Valve Installation and Maintenance Instructions

Pressure Reducing Valve for Steam Type 2333 A

TECHNICAL DATA. Pressure Regulation 531a. April 24, 2009

Series 42 Self-operated Regulators Differential Pressure Regulators with Type 2424/Type 2428 Actuator (closing) Type Type 42-28

Si C132. Safety valves for pressure relief in accordance to PED, DIN/EN and ASME. Engineering GREAT Solutions

Description Supply pressure Pressure range Connection Device Page max. bar bar thread

Differential pressure controller (PN 16) AVPL - return mounting, adjustable setting

HANDBOOK SAFETY DEVICES. Ed SAFETY DEVICES DS-ED 01/ ENG 1

TECHNICAL DATA CAUTION

POP Safety Valve. POP Safety Valve INTRODUCTION DEFINITIONS

Gas Pressure Regulator HON 300

Water. VAG DUOJET Automatic Air Valve Single-chamber type PN 10/16/25/40 - DN KAT-A 1912

Pipe threads for tubes and fittings where pressure-tight joints are not made on the threads. (requires PTFE sealing tape or liquid sealant).

SCA Series Inverted Bucket Steam Traps

Model GP PRESSURE REDUCING VALVE Installation & Operation Manual

Ball valve HKSF-W100. Ball valve HKSF-W100. RMA Kehl GmbH & Co. KG Oststrasse 17 D Kehl / Germany

Pressure Reducing Valve DMV 755

V43 Pressure Actuated Water Regulating Valve

safety Shut-Off Valve HON 721

Differential Pressure Regulator Type Type 45-6 (0.1 to 1 bar, DN 15) Mounting and Operating Instructions EB 3226 EN

IP2, IP2A and IP2D. Spirax-Monnier International Compressed Air Filter/ Regulators

Shut-off ball valve Type GBC

The Compact, Portable, Efficient and Economical Solution to boost Shop Compressed Air Pressure by 2 or 3 times

Series MG Mixing Tubes

Self-operated Pressure Regulators for special applications

PTF4 Pivotrol Pump (patented) version Dual Mechanism - Pressure Powered Pump

Sales Office: Danfoss Expansion Valves. T*2 Range Order valve and orifice separately Range N -40 C to +10 C Without MOP

Transcription:

Catalogue Shut-off Liquid level and regulating valves for for Industrial Refrigeration Contents Page Float valve, type HFI... 3 Float valves, types SV 1 and 3... 17 Float valves, types SV 4, SV 5 and SV 6... 27 Liquid level regulating valves, types PMFL / PMFH and SV.... 39 Liquid Level Alarms, types RT28A, RT281A.... 53 Sight glasses, type LLG 185-155... 59 AF24258644423en-78 1

Shut-off Float valve and regulating valves for Type Industrial HFI Refrigeration Contents Page Features... 5 Design... 6 Technical data... 6 The principle of high pressure control... 6 Insert for the high pressure float valve.... 7 Computation and selection... 7 High pressure control in refrigeration system with condenser / evaporator... 1 Material specification............................................................................. 11 Connections... 12 Dimensions and weights.... 13 Volumes... 15 Ordering... 15 AF24258644423en-77 218.6 AF24258644423en-78 3

Shut-off Float valve and regulating valves for Type Industrial HFI Refrigeration HFI is a high pressure float valve with internal liquid measuring device. The float valve is designed for direct flange mounting or welding on to plate heat exchanger type condensers, as illustrated in fig 1. HFI is direct acting, therefore no differential pressure is required to activate the valve. HFI is sturdy and reliable owing to its simple design. The float valve is equipped with a purge valve for purging non condensable gases e.g. air from the top of the valve housing. This facility is also useful if the valve has to be serviced. The HFI is available with two external connections on the housing for drainage and pressure equalizations. Features Designed for direct flange mounting on to plate heat exchanger type condensers Can be mounted directly on vessels Temperature range: -5 8 C / -58 176 F Equipped with purge valve for purging non condensable gasses Available with external connections for drainage and pressure equalizations Maximum operating pressure is 25 bar g / 363 psi g Suitable for R717 (ammonia), HCFC and HFC with a density of 5 through 7 kg/m 3 (31.21 43.7 lb/ft 3 ). For densities outside this range please contact your local Danfoss sales company. Housing i.e. shell and flange are made of special steel approved for low temperature application Classification: DNV, CRN, BV, EAC etc. To get an updated list of certification on the products please contact your local Danfoss Sales Company Fig. 1 AF24258644423en-78 5

Float valve, type HFI Design Available connections Flange: Inlet: Flange DN 1 or DN 15 (DIN-2635/DIN 2512-F) Outlet: Welding connection DN 5 (EN 122) Butt-weld, DIN: Inlet: DN 1 or DN 15 (EN 122) Outlet: Welding connection DN 5 (EN 122) Butt-weld, ANSI: Inlet: DN 1 (4 in) or DN 15 (6 in) (ANSI B 36.1) Outlet: Welding connection DN 5 (2 in) (ANSI 36.1) Housing Housing i.e. shell and flange is made of special steel approved for low temperature operation. Installation Refer to installation instruction for HFI. Identification: Pressure Equipment Directive (PED) The HFI-valves are approved in accordance with the European standard specified in the Pressure Equipment Directive and are CE marked. For further details / restrictions - see Installation Instruction Nominal bore Classified for Catagory HFI valves DN 1 and 15 mm (4 in and 6 in) Fluid group I III Technical data Refrigerants Suitable for R717 (ammonia), HCFC and HFC with a density of 5 through 7 kg/m 3 (31.21-43.7 lb/ft 3 ). For densities outside this range please contact your local Danfoss sales company. Flammable hydrocarbons are not recommended. For further information please contact your local Danfoss Sales Company. Temperature range -5 8 C / -58 176 F Pressure The float valve is designed for: Maximum operating pressure: 25 bar g / 363 psi g. Strength test without float ball: 42 bar g / 69 psi g. Leakage test: 25 bar g / 363 psi g. Valves for higher pressure are available on request. The principle of high pressure control Introduction In installations with one application high pressure control is an effective and cost saving way of expanding liquid from the condenser to the low pressure side. High pressure refrigerant entering the condenser will start to condense, consequently condensate will accumulate at the bottom of the condenser and in the float valve. When capacity demands increase, the liquid level in the float valve will rise, which will cause the valve to open and the refrigerant to expand into the separator at the low pressure side. When the valve is closed, there will still be a small by-pass over the seat, so any remaining liquid will equalize slowly to the low pressure side, for instance during an off cycle. Therefore the system will equalize automatically and the compressor can start up without excessive back pressure. The size of the bypass is pre determined and defined by geometry of the elements. It follows from the above, that almost all the refrigerant will be accumulated on the low pressure side under normal conditions. Therefore under normal conditions no high pressure receiver is necessary when using the HFI for high pressure control. 6 AF24258644423en-78

Float valve, type HFI Insert for the high pressure float valve Detail A Fully closed Detail B Fully open A Fig. 3 B Fig. 4 Computation and selection In R 717 plants (ammonia) On the following pages you will find tables with capacities of the float valve at various operating conditions. Select a valve using the specific operating conditions. The chosen valve must have a capacity higher than the required capacity during nominal operation, as well as during plant start up. In plants using other refrigerants than ammonia The capacity of the float valve can be calculated by using the values and the equation to the right. However, the density of the refrigerant must be in the range: 5 to 7 kg/m 3. Valve type Nominal capacity [kw] (R 717, -1 35 C) Valve constant [K] HFI 4 FD 4 16.79 HFI 5 FD 8 33.58 HFI 6 FD 12 5.36 For densities outside this range please contact HFI 7 FD 24 1 your local Danfoss Sales Company. Mass flow G = p = differential pressure [bar] ρ = density of liquid [kg/m 3 ] K = valve constant (from the above table) AF24258644423en-78 7

Float valve, type HFI Computation and selection capacity tables - SI units HFI 4 - R 717, evaporating capacity [kw] Condensing temp. ( C) 5 45 4 35 3 25 2 15 1 5-5 -1 Evaporating temperature ( C) -4-35 -3-25 -2-15 -1-5 5 1 15 2 475 46 44 42 4 38 36 34 315 29 27 245 22 48 46 44 42 4 38 355 335 31 285 26 235 21 48 46 44 42 4 375 355 33 35 28 255 225 2 475 46 44 415 395 37 35 325 295 27 24 21 18 475 455 435 415 39 365 34 315 285 255 225 19 155 475 455 43 45 385 36 33 3 27 24 25 165 115 47 445 425 4 375 345 315 285 25 215 175 12 46 44 415 39 36 33 3 265 225 185 125 455 43 45 375 345 315 28 24 195 135 445 42 39 36 325 29 25 2 14 43 45 375 34 3 26 21 15 415 385 35 315 27 22 155 395 36 325 28 23 16 HFI 5 - R 717, evaporating capacity [kw] Condensing temp. ( C) 5 45 4 35 3 25 2 15 1 5 5 1 Evaporating temperature ( C) -4-35 -3-25 -2-15 -1-5 5 1 15 2 955 92 88 845 85 765 72 675 63 585 54 49 44 955 92 88 845 8 76 715 67 625 575 525 475 42 955 92 88 84 8 755 75 66 61 56 55 455 395 955 915 875 835 79 745 695 645 595 54 485 425 36 95 91 87 825 78 73 68 63 57 515 45 385 35 945 95 86 815 765 715 66 65 545 48 45 325 23 935 895 85 8 75 695 635 57 55 43 345 24 925 88 83 78 725 665 6 53 455 365 255 91 86 81 755 695 63 555 48 385 27 89 835 78 72 655 58 5 45 285 865 85 745 68 65 52 42 295 83 77 7 625 54 44 31 79 725 645 56 455 32 HFI 6 - R 717, evaporating capacity [kw] Condensing temp. ( C) 5 45 4 35 3 25 2 15 1 5 5 1 Evaporating temperature ( C) -4-35 -3-25 -2-15 -1-5 5 1 15 2 143 138 1325 1265 125 1145 18 115 945 875 85 735 66 1435 138 1325 1265 125 114 17 15 935 86 785 71 635 1435 138 132 126 1195 113 16 99 915 84 76 68 595 143 1375 1315 125 1185 1115 145 97 89 81 725 635 54 1425 137 135 124 117 11 12 94 86 77 675 575 46 142 136 129 122 115 175 99 95 815 72 61 49 34 145 134 127 12 112 14 95 86 755 645 52 36 1385 132 1245 117 185 995 9 795 68 55 38 1365 129 1215 113 14 94 835 715 58 45 1335 1255 117 18 98 87 75 65 425 1295 121 112 12 95 78 635 445 1245 1155 155 94 81 66 465 119 185 97 84 685 485 HFI 7 - R717, evaporating capacity [kw] Condensing temp. ( C) Evaporating temperature ( C) -4-35 -3-25 -2-15 -1-5 5 1 15 2 5 45 4 35 2445 3 25 2 15 1 5-5 -1 147 1325 1725 1575 1425 1265 1835 168 152 136 119 29 194 1785 162 145 127 18 234 2195 24 1885 1715 154 135 115 92 23 2145 198 181 163 1435 122 98 685 268 2545 24 2245 28 19 1715 1515 1295 14 725 2775 264 249 2335 217 1995 18 1595 1365 11 765 2725 258 2425 226 28 1885 167 1435 116 81 2665 251 234 216 196 1745 15 121 85 259 242 2235 235 1815 1565 1265 89 2495 231 215 188 1625 132 93 2375 217 194 168 137 965 8 AF24258644423en-78

Float valve, type HFI Computation and selection capacity tables - US units HFI 4 - R 717, evaporating capacity [TR] Condensing temp. ( F) 12 11 1 9 8 7 6 5 4 3 2 1 Evaporating temperature ( F) -4-3 -2-1 1 2 3 4 5 6 7 8 134 129 123 117 11 13 97 9 82 75 67 59 135 129 123 117 11 13 96 88 81 73 65 56 135 129 122 116 19 12 94 86 78 7 61 51 134 128 122 115 17 1 92 83 75 65 55 44 134 127 12 113 15 97 89 8 7 59 47 33 132 126 118 111 12 94 84 74 63 51 35 131 123 116 17 99 89 79 67 54 38 128 121 112 13 94 83 71 57 4 125 117 18 98 87 75 6 42 121 112 12 91 78 63 44 116 16 94 81 66 47 19 98 84 69 49 11 87 71 5 HFI 5 - R 717, evaporating capacity [TR] Condensing temp. ( F) 12 11 1 9 8 7 6 5 4 3 2 1 Evaporating temperature ( F) -4-3 -2-1 1 2 3 4 5 6 7 8 268 258 246 234 221 27 193 179 165 15 135 119 269 258 246 233 22 26 191 176 161 145 129 112 269 257 245 232 218 23 188 172 156 139 121 12 269 256 243 229 215 2 184 167 149 13 11 88 267 254 241 226 211 194 177 159 14 118 95 65 265 251 237 221 25 187 169 149 127 12 7 261 247 232 215 197 178 157 134 18 75 256 241 224 27 187 166 142 114 8 25 233 215 196 174 149 121 84 242 224 24 181 156 127 89 231 211 189 163 132 93 218 195 169 138 97 21 175 143 11 HFI 6 - R 717, evaporating capacity [TR] Condensing temp. ( F) 12 11 1 9 8 7 6 5 4 3 2 1 Evaporating temperature ( F) -4-3 -2-1 1 2 3 4 5 6 7 8 43 386 369 35 331 31 29 269 247 225 22 178 44 387 368 35 329 39 287 265 242 218 194 168 44 386 367 348 327 35 282 259 234 29 182 153 43 384 365 344 322 299 275 25 224 196 165 132 41 381 361 339 316 292 266 239 29 178 142 98 397 377 355 332 37 281 253 223 19 152 16 392 37 347 322 296 267 236 22 162 113 385 362 337 31 281 249 213 172 12 375 35 323 293 261 224 181 126 363 335 35 272 234 19 133 347 317 283 244 199 14 327 293 253 27 146 32 262 214 151 HFI 7 - R717, evaporating capacity [TR] Condensing temp. ( F) Evaporating temperature ( F) -4-3 -2-1 1 2 3 4 5 6 7 8 12 11 1 9 678 8 7 6 5 517 4 3 2 1 44 357 483 436 387 336 469 418 364 37 599 551 5 448 391 331 263 632 583 532 477 419 355 284 195 71 664 615 562 56 446 38 35 211 784 741 695 645 592 534 472 43 325 226 769 723 673 62 561 497 426 343 24 75 7 646 587 521 447 362 253 725 671 611 544 469 38 267 694 633 566 489 397 279 654 586 57 413 292 63 524 428 32 AF24258644423en-78 9

Float valve, type HFI High pressure control in refrigeration system with condenser / evaporator Fig. 5 shows a water chiller with plate heat exchanger as both condenser and evaporator. HFI is flanged directly on to the condenser. Compressor Vapor Liquid High pressure Float Valve - HFI Fig. 5, Example High pressure condenser Water chiller (evaporator) 1 AF24258644423en-78

Float valve, type HFI Material specification Fig. 6 1f 1g e No Part Material DIN/EN ASTM 1 Housing: a. Shell b. Flange (shell) c. Flange (inlet) d. Branch (discharge) e. External connection f. Flange (shell) g. Connecting tube Steel Steel Steel Steel Steel Steel Steel P215NL, EN 1216-4 P275 NL1, EN128-3 P285QH EN 1222-4 P275 NL1, EN128-3 P285QH EN 1222-4 P215NL, EN 1216-4 P275 NL1, EN128-3 3 End cover with cylinder Steel P275 NL1, EN 1 28-3 4 Set screw Stainless steel A2-7 5 Tube Steel 6 Gasket Aluminium 7 Purge valve, SNV-ST 1 ) 8 Gasket Non asbestos 9 Float Ball Steel 1 ) SNV-ST G½-G½ (148B3745). Grade 1, A333, A334 Grade A, A662 LF2A35 Grade A, A662 LF2A35 Grade 1, A333, A334 Grade A, A662 AF24258644423en-78 11

Float valve, type HFI Connections DIN - Outlet Butt-weld DIN (EN 122) HFI size mm HFI size in. OD mm T mm Outlet OD in. T in. For use with valve type 1 4 6.3 2.9 2.37.11 15 6 6.3 2.9 2.37.11 HFI 4 HFI 5 HFI 6 HFI 7 HFI 5 HFI 6 HFI 7 ANSI - Outlet Butt-weld ANSI (B 36.1 Schedule 4) HFI size mm HFI size in. OD mm T mm Outlet OD in. T in. For use with valve type 1 4 6.3 3.9 2.37.15 15 6 6.3 3.9 2.37.15 HFI 4 HFI 5 HFI 6 HFI 7 HFI 5 HFI 6 HFI 7 DIN - Inlet Butt-weld DIN (EN 122) HFI size mm HFI size in. OD mm T mm Inlet OD in. T in. For use with valve type 1 4 114.3 3.6 4.5.14 15 6 168.3 4.5 6.63.18 HFI 4 HFI 5 HFI 6 HFI 7 HFI 5 HFI 6 HFI 7 ANSI - Inlet Butt-weld ANSI (B 36.1 Schedule 4) HFI size mm HFI size in. OD mm T mm Inlet OD in. T in. For use with valve type 1 4 114.3 6.3 4.5.25 15 6 168.3 7.1 6.63.28 HFI 4 HFI 5 HFI 6 HFI 7 HFI 5 HFI 6 HFI 7 Inlet flange 4 bar / DIN 2635 / DIN 2512-F* D b k d 42 d 43 F d 2 Z Size 1 (4 in.) mm 235 24 19 129 149 4.5 22 in. 9.3.94 7.48 5.8 5.87.18.97 Size 15 (6 in.) mm 3 28 25 183 23 4.5 26 in. 11.8 1.1 9.84 7.2 7.99.18 1.2 *Inlet flange and DIN outlet 8 pcs. 8 pcs. 12 AF24258644423en-78

Float valve, type HFI Dimensions and weights Fig. 7 High pressure float valve without flange (Fig. 7) Valve size A 1 A 2 A 3 B C ØD F min. Weight HFI 1 [mm] 192 113 25 276 435 219 2 37 kg [in] 7.56 4.45.98 1.87 17.13 8.62 7.87 81.5 lb HFI 15 [mm] 167 113 276 435 219 2 37 kg [in] 6.57 4.45 1.87 17.13 8.62 7.87 81.5 lb Specified weights are approximate values only. Fig. 8 High pressure float valve with flange (Fig. 8) Valve size A 1 A 2 A 3 B C ØD F min. Weight HFI 1 [mm] 192 18 25 39 52 219 2 41 kg [in] 7.56 7.9.98 12.17 19.76 8.62 7.87 9.4 lb HFI 15 [mm] 167 189 317 511 219 2 41 kg [in] 6.57 7.44 12.48 2.12 8.62 7.87 9.4 lb Specified weights are approximate values only. AF24258644423en-78 13

Float valve, type HFI Dimensions and weights (HFI with external connections) External connections EXC2 øe EXC1 Fig. 7 4 High pressure float valve without flange (Fig. 7) Valve size A 1 A 2 A 3 A 4 B C ØD ØE F min. Weight HFI 1 [mm] 192 113 25 176 276 435 219 247 2 37 kg [in] 7.56 4.45.98 6.93 1.87 17.13 8.62 9.72 7.87 81.5 lb HFI 15 [mm] 167 113 176 276 435 219 247 2 37 kg [in] 6.57 4.45 6.93 1.87 17.13 8.62 9.72 7.87 81.5 lb Specified weights are approximate values only. External connections EXC2 øe EXC1 Fig. 8 4 High pressure float valve with flange (Fig. 8) Valve size A 1 A 2 A 3 A 4 B C ØD ØE F min. Weight HFI 1 [mm] 192 18 25 176 39 52 219 247 2 41 kg [in] 7.56 7.9.98 6.93 12.17 19.76 8.62 9.72 7.87 9.4 lb HFI 15 [mm] 167 189 176 317 511 219 247 2 41 kg [in] 6.57 7.44 6.93 12.48 2.12 8.62 9.72 7.87 9.4 lb Specified weights are approximate values only. EXC1 EXC2 3/8-18 NPT 1/2-14 NPT 14 AF24258644423en-78

Float valve, type HFI Volumes Fig. 9 Internal volume (gross): 8.2 1 3 m 3 (2.17 USgal) Internal volume with float ball: 6.4 1 3 m 3 (1.69 USgal) Liquid volume at max. level: 4.6 1 3 m 3 (1.22 USgal) Liquid volume at min. level: 1.6 1 3 m 3 (.42 USgal) Ordering The table below is used to identify the valve required. Example: HFI 4 D 1 = 148G392 Type Inlet connection size Nozzle size Code numbers HFI 4 FD 1 4 148G312 HFI 5 FD 1 5 148G313 1 (4 in) DIN Flange HFI 6 FD 1 6 148G314 HFI 7 FD 1 7 148G3422 HFI 5 FD 15 5 148G315 HFI 6 FD 15 15 (6 in) DIN Flange 6 148G316 HFI 7 FD 15 7 148G3423 HFI 4 D 1 4 148G392 HFI 5 D 1 5 148G393 1 (4 in) DIN BW HFI 6 D 1 6 148G394 HFI 7 D 1 7 148G3418 HFI 5 D 15 5 148G395 HFI 6 D 15 15 (6 in) DIN BW 6 148G396 HFI 7 D 15 7 148G3419 HFI 4 A 1 4 148G397 HFI 5 A 1 5 148G398 1 (4 in) ANSI BW HFI 6 A 1 6 148G399 HFI 7 A 1 7 148G342 HFI 5 A 15 5 148G31 HFI 6 A 15 15 (6 in) ANSI BW 6 148G311 HFI 7 A 15 7 148G3421 HFI with 2 external connections FD = inlet flange DIN D = Butt welding DIN A = Butt welding ANSI Type Inlet connection size Nozzle size Code numbers HFI 4 FD 1 w. 2 ext. con 4 148G3196 HFI 5 FD 1 w. 2 ext. con 5 148G3727 1 (4 in) DIN Flange HFI 6 FD 1 w. 2 ext. con 6 148G367 HFI 7 FD 1 w. 2 ext. con 7 148G3671 HFI 5 FD 15 w. 2 ext. con 5 148G3762 HFI 6 FD 15 w. 2 ext. con 15 (6 in) DIN Flange 6 148G3763 HFI 7 FD 15 w. 2 ext. con 7 148G3764 HFI 4 D 1 w. 2 ext. con 4 148G3765 HFI 5 D 1 w. 2 ext. con 5 148G374 1 (4 in) DIN BW HFI 6 D 1 w. 2 ext. con 6 148G3766 HFI 7 D 1 w. 2 ext. con 7 148G372 HFI 5 D 15 w. 2 ext. con 5 148G3767 HFI 6 D 15 w. 2 ext. con 15 (6 in) DIN BW 6 148G3768 HFI 7 D 15 w. 2 ext. con 7 148G3769 Insert for HFI 7 (complete insert with float ball - without float housing) Insert for HFI 6 ( complete insert with float ball - without float housing) Insert for HFI 5 ( complete insert with float ball - without float housing) Insert for HFI 4 ( complete insert with float ball - without float housing) 148G3584 148G3663 148G3662 148G3661 AF24258644423en-78 15

Float valve, type HFI Accessories Type Connection type Quantity Code no. Welding nipple incl. aluminium gasket G½-ND6 2 pcs. 148B4184 Al gaskets included 1 / 4 FPT ½ G 1 pc. 148B386 Al gaskets included 3 / 8 G - ½ G 1 pc. 148B3861 16 AF24258644423en-78

Shut-off Float valves and regulating valves for Types Industrial SV 1 and Refrigeration SV 3 Contents Page Approvals... 19 Identification... 2 Dimensioning example for SV (L)... 2 Ordering... 2 Pipe dimensions... 2 Capacity... 21 Design / function................................................................................. 22 SV 1-3 used as a high pressure defrost drain float valve.... 25 Dimensions and weight.... 26 AI22168643747en-81 217.1 AF24258644423en-78 17

Shut-off Float valves and regulating valves for Types Industrial SV 1 and Refrigeration SV 3 The SV 1 and 3 can be used separately as a modulating liquid level regulator in refrigerating, freezing and air conditioning systems for ammonia or fluorinated refrigerants. However, in most cases, the SV is used as a float pilot valve for the main expansion valve type PMFH. Technical data Refrigerant Applicable to HCFC, HFC and R717 (Ammonia). P band 35 mm Temperature of medium -5 65 C Max. working pressure PS = 28 bar Max. test pressure p' = 36 bar k v value for float orifice SV 1 =.6 m 3 /h SV 3 =.14 m 3 /h The highest k v value for the built-in throttle valve is.18 m 3 /h. The throttle valve can be used both in parallel and in series with the float orifice. Classification: DNV, CRN, BV, EAC etc. To get an updated list of certification on the products please contact your local Danfoss Sales Company. Approvals Pressure Equipment Directive (PED) SV1 and 3 are approved in accordance with the European standard specified in the Pressure Equipment Directive and are CE marked. Classified for Category SV1 and 3 Fluid group I I For further details / restrictions - see Installation Instruction AF24258644423en-78 19

Float valves, types SV 1 and 3 Identification Dimensioning example for SV (L) Refrigerant R717 (NH 3) Evaporating capacity Q e = 27 kw Evaporating temperature t e = -1 C (~ p e = 2.9 bar abs.) Condensing temperature t c = 3 C (~ p c = 11.7 bar abs.) Liquid temperature for SV t l = 2 C Subcooling t sub = t c - t l = 3 C - 2 C = 1 K Pressure drop in SV p = p c - p e = 11.7-2.9 = 8.8 bar Correction factor k for 1 K subcooling.98 Corrected capacity 27.98 = 26.4 kw At t e = -1 C and p = 8 bar SV 1 yields 27 kw and can therefore be used. If SV 3 is used for this capacity, it will mean a small offset. Ordering Regulator The code nos. stated apply to float valves, types SV 1 and SV 3 incl. 6.5 / 1 mm weld connection 1 ) for the pilot line. Balance tube connection (liquid / vapour): 1 in weld / 1 1 8 in solder. The rated capacity refers to the valve capacity at evaporating temperature t e = 5 C, condensing temp. t c = 32 C and liquid temperature t l = 28 C. Valve type Code no. Rated capacity in kw R717 R22 R134a R44A R12 R52 SV 1 27B221 25 4.7 3.9 3.7 3.1 3.4 SV 3 27B223 64 13 1. 9.7 7.9 8.8 1 ) 3 8 in flare connection can be supplied under code no. 27B233. Spare parts and accessories See spare parts catalogue. Pipe dimensions Liquid line The following suggested dimensions for the liquid line, which is connected to the nipple pos. C, see "Design / Function", are based on a maximum velocity in a line with subcooled ammonia of approx. 1 m/s and a maximum velocity in a line with subcooled fluorinated refrigerant of approx..5 m/s. 1. R717 (ammonia) Dimensions Type.8 bar < p sv < 4 bar 4 bar < p sv < 16 bar Steel tube Steel tube SV 1 3 8 in 3 8 in SV 3 3 8 in 1 2 in 2. R22, R134a, R44A Dimensions Type.8 bar < p sv < 4 bar 4 bar < p sv < 16 bar Steel tube Copper tube Steel tube Copper tube SV 1 3 8 in 3 8 in 3 8 in 1 / 2 in SV 3 3 8 in 5 8 in 1 2 in 3 4 in Upper balance pipe (connect to pos. D on SV (L) Type Dimensions SV (L) 1 1 in SV (L) 3 1 1 2 in 2 AF24258644423en-78

Float valves, types SV 1 and 3 Capacity The values in the capacity tables are based on a subcooling of 4 K just ahead of the SV valve. If the subcooling is more or less than 4 K, refer to the following correction factors. Type Evaporating temperature t e [ C] Capacity in kw at pressure drop across valve p bar.8 1.2 1.6 2 4 8 12 16 Type Evaporating temperature t e [ C] Capacity in kw at pressure drop across valve p bar.8 1.2 1.6 2 4 8 12 16 R717 (NH 3 ) R22 SV 1 1-1 -2-3 -4-5 9.5 9.9 1 11 11 11 11 11 12 12 12 12 13 12 13 14 14 14 14 14 13 15 15 15 15 15 15 15 2 2 21 21 2 2 2 27 27 27 27 26 26 26 3 31 31 3 3 29 29 33 33 33 33 32 32 SV 1 1-1 -2-3 -4-5 2.2 2.3 2.4 2.4 2.5 2.5 2.6 2.6 2.7 2.8 2.9 2.9 2.9 2.9 3. 3.1 3.2 3.3 3.3 3.3 3.3 3.2 3.4 3.5 3.6 3.6 3.6 3.5 4.2 4.4 4.5 4.6 4.5 4.4 4.3 4.8 4.9 5. 5. 5. 4.9 4.8 5.7 5.8 5.8 5.8 5.7 5.6 5.4 5.7 5.8 5.9 5.8 5.7 5.6 5.4 SV 3 1-1 -2-3 -4-5 25 26 26 26 25 24 23 31 32 32 31 3 29 27 35 36 36 35 34 33 31 39 4 4 39 38 36 35 52 52 52 52 5 49 47 71 69 68 67 66 65 64 77 78 77 76 75 73 71 83 83 82 82 8 79 SV 3 1-1 -2-3 -4-5 5.6 5.8 6. 6.1 6.2 6.1 5.9 6.8 7. 7.3 7.3 7.3 7.1 6.9 7.7 8. 8.2 8.3 8.1 7.9 7.6 8.5 8.8 9. 8.9 8.8 8.5 8.2 11 11 12 11 11 11 11 13 13 13 13 12 12 12 15 15 15 14 14 14 13 15 15 15 15 14 14 14 Correction factors When dimensioning, multiply the evaporator capacity by a correction factor k dependent on the subcooling t sub just ahead of the valve. The corrected capacity can then be found in the capacity table. R717 (NH3) t K 2 4 1 15 2 25 3 35 4 45 5 k 1.1 1..98.96.94.92.91.89.87.86.85 R22 t K 2 4 1 15 2 25 3 35 4 45 5 k 1.1 1..96.93.9.87.85.83.8.78.77 AF24258644423en-78 21

Float valves, types SV 1 and 3 Design / function SV with low-pressure function C. Nipple D. Connection for balance pipe P. Parallel connection of pos. C (screw 17 in pos. A) S. Series connection of pos. C (screw 17 in pos. B) No. Part Material DIN / EN 1 Float housing Stainless steel Low temperature, steel 2 Float Stainless steel 3 Split pin Steel 4 Float arm Stainless steel 5 Link Steel 6 Pin Stainless steel 7 Valve housing Steel 8 O-ring Cloroprene (Neoprene) 9 Float orifice Plastic 1 Manual regulation unit. Throttle valve Steel 11 Gasket Non asbestos 12 Plug Steel 13 O-ring Cloroprene (Neoprene) 14 Pilot connection (spare part) Steel 15 Orifice needle Plastic 16 O-ring Cloroprene (Neoprene) 17 Screw Steel 18 Gasket Non asbestos 19 Pin Steel 2 Cover Low temperature, cast iron (spherical) 21 Screw Stainless steel A2-7 22 Gasket Non asbestos 23 Label Cardboard 25 Screw Steel 26 Spring washer Steel 28 Sign Aluminium X5CrNi18-1, DIN 1744 P285QH, EN 1222-4 EN-GJS-4-18-LT EN 1563 22 AF24258644423en-78

Float valves, types SV 1 and 3 Design / function (continued) SV (L), low-pressure function SV (L) is used for small, flooded evaporators, where only slight variations in the liquid level can be accepted. When the liquid level falls, the float pos. (2) moves downwards. This draws the needle pos. (15) away from the orifice and the amount of liquid injected is increased. The liquid inlet line, which is mounted on the nipple pos. (C), should be dimensioned in such a way that acceptable liquid velocities and pressure drops are obtained. This is particularly important when the liquid is only slightly subcooled, since valve capacity is reduced considerably if flashgas occurs in the liquid ahead of the orifice and wear is strongly increased. See the suggested dimensions for the liquid line in "Pipe dimensions". The flashgas quantity which occurs on expansion is removed through the balance pipe from pos. (D). On refrigeration plant using fluorinated refrigerants, slight subcooling and a large pressure drop can give a flashgas quantity of approx. 5% of the injected liquid quantity. Therefore the pressure drop in this balance pipe must be kept at a minimum, since there will otherwise be a risk that the liquid level in the evaporator will vary to an unacceptable degree as a function of evaporator load the absolute difference between the liquid level of the evaporator and the SV valve will be too large. See the suggested dimensions for the balance pipe in "Pipe dimensions". AF24258644423en-78 23

Float valves, types SV 1 and 3 Design / function (continued) SV with high-pressure function C. Nipple D. Connection for balance pipe P. Parallel connection of pos. C (screw 17 in pos. A) S. Series connection of pos. C (screw 17 in pos. B) No. Part Material DIN / EN 1 Float housing Stainless steel Low temperature, steel 2 Float Stainless steel 3 Split pin Steel 4 Float arm Stainless steel 5 Link Steel 6 Pin Stainless steel 7 Valve housing Steel 8 O-ring Cloroprene (Neoprene) 9 Float orifice Plastic 1 Manual regulation unit. Throttle valve Steel 11 Gasket Non asbestos 12 Plug Steel 13 O-ring Cloroprene (Neoprene) 14 Pilot connection (spare part) Steel 15 Orifice needle Plastic 16 O-ring Cloroprene (Neoprene) 17 Screw Steel 18 Gasket Non asbestos 19 Pin Steel 2 Cover Low temperature, cast iron (spherical) 21 Screw Stainless steel A2-7 22 Gasket Non asbestos 23 Label cardboard 25 Screw Steel 26 Spring washer Steel 28 Sign Aluminium X5CrNi18-1, DIN 1744 P285QH, EN 1222-4 EN-GJS-4-18-LT EN 1563 24 AF24258644423en-78

Float valves, types SV 1 and 3 Design / function (continued) SV (H), high-pressure function SV (H) is used as a liquid level regulator for small condensers or receivers. When the liquid level rises, the float pos. (2) moves upwards. This draws the needle pos. (15) away from the orifice and the excess liquid is drawn away. On refrigeration plant using fluorinated refrigerants slight subcooling and a large pressure drop can, as already mentioned, cause the formation of a large amount of flashgas. This mixture of liquid and vapour has to pass through the nipple pos. (C) and out into the liquidline. If the dimensions of the line are too small, a pressure drop will occur which can reduce the capacity of the SV (H) valve considerably. This will mean a risk of inadvertent liquid accumulation in the condenser or receiver. See the suggested dimensions for the liquid line in "Pipe dimensions". The connection nipple (C) can be mounted either in P or in S. P-connection P-connection (= parallel) With P-connection an SV with closed float orifice will have a capacity which corresponds to the degree of opening of the adjustable throttle valve 1. S-connection S-connection (= series) With S-connection the throttle valve 1 will function as a pre-orifice on SV (L) and as a post orifice on SV (H). SV 1-3 used as a high pressure defrost drain float valve SV 1-3 can be used as a defrost drain float valve, when one balance pipe is sealed off and the liquid level regulator is mounted with a special kit (code no. 27B254) consisting of: Special orifice and orifice needle with a larger k v-value of.28 m 3 /h. Gas drain pipe Liquid out to wet suction Condensed liquid in from evaporator SV 1-3 fitted with the special kit AF24258644423en-78 25

Float valves, types SV 1 and 3 SV 1-3 used as a high pressure defrost drain float valve (continued) Application example Wet suction line PMLX Liquid line Hotgas line SV 1-3 with special kit mounted as defrost drain float valve on a flooded evaporator with hotgas defrost. Dimensions and weight SV 1 and SV 3 ID 6.8 OD 9.8 ID 28 155 122.6 92 92 5+2 141.5 ID 28 Weight 5.7 kg 132 16 74.5 17.5 Danfoss 27B326.12 Pilot connection (weld / solder) DANFOSS 27F691_1-217 M16 1.5 AF 19 G 3 / 8 A 6.5 / 1 AF 22 26 AF24258644423en-78

Shut-off Float valves and regulating valves for Types Industrial SV 4, SV Refrigeration 5 and SV 6 Contents Page Features... 29 Technical data... 29 Approvals... 3 Identification... 3 Materials... 3 Dimensioning example for SV... 3 Capacity... 31 Construction / function... 32 Application... 35 Dimensions and weight.... 36 Ordering... 37 AI175286419654en-56 218.1 AF24258644423en-78 27

Shut-off Float valves and regulating valves for Types Industrial SV 4, SV Refrigeration 5 and SV 6 SV 4-6 are for use on the low pressure side as modulating liquid level regulators in refrigeration, freezing and air conditioning systems with ammonia and other common types of refrigerants. Features Reliable function Stable regulation, even during momentary load change Liquid injection into the float housing or directly into the evaporator through external pipe connection Orifice assembly and filter can be replaced without evacuating the float housing Can be supplied without float housing for direct installation in the system (special order only) Can be used as pilot float for PMLF if mounted with special orifice (diameter Ø2.5 mm) Classification: DNV, CRN, BV, EAC etc. To get an updated list of certification on the products please contact your local Danfoss Sales Company Technical data Refrigerants Applicable to HCFC, HFC and R717 (Ammonia). Use with flammable hydrocarbons cannot be recommended; please contact Danfoss. P band Approx. 35 mm Max. working pressure MWP = 28 bar Max. p SV 4 = 23 bar SV 5 = 21 bar SV 6 = 19 bar Media temperature -5 12 C Max. test pressure MTP = 32 bar k v value and diameter for orifice SV 4: k v =.23 m 3 /h D = 3. mm SV 5: k v =.31 m 3 /h D = 3.5 mm SV 6: k v =.43 m 3 /h D = 4. mm AF24258644423en-78 29

Float valves, types SV 4, SV 5 and SV 6 Approvals Pressure Equipment Directive (PED) SV 4, 5 and 6 are approved in accordance with the European standard specified in the Pressure Equipment Directive and are CE marked. For further details / restrictions - see Installation Instruction Classified for Category SV 4, 5 and 6 Fluid group I II Identification Materials Gaskets are non asbestos Valve housing made of lowtemperature cast iron, spherical (EN-GJS-4-18-LT) Float housing: ST 35.8 DIN 17175 W. no. 1.35 Dimensioning example for SV Refrigerant R717 (NH 3) Evaporating capacity Q e = 145 kw Evaporating temperature t e = -1 C (~ p e = 2.9 bar abs.) Condensing temperature t c = 3 C (~ p c = 11.7 bar abs.) Liquid temperature ahead of SV t l = 2 C Subcooling t sub = t c - t l = 3 C - 2 C = 1 K Pressure drop in SV p = p c - p e = 11.7-2.9 = 8.8 bar Correction factor k for 1 K subcooling =.98 Corrected capacity 145.98 = 142 kw At t e = -1 C and p = 8 bar SV 5 yields 147 kw and can therefore be used. 3 AF24258644423en-78

Float valves, types SV 4, SV 5 and SV 6 Capacity The values in the capacity tables are based on a subcooling of 4 K just ahead of the SV valve. If the subcooling is more or less than 4 K, refer to the following correction factors. Type Evaporating temperature t e [ C] Capacity in kw at pressure drop across valve p bar.8 1.2 1.6 2 4 8 12 16 Type Evaporating temperature t e [ C] Capacity in kw at pressure drop across valve p bar.8 1.2 1.6 2 4 8 12 16 R717 (NH 3 ) R22 SV 4 1-1 -2-3 -4-5 37 39 4 41 42 42 43 45 47 48 49 5 51 51 52 54 55 56 57 58 58 58 59 61 62 63 63 63 79 81 82 83 84 84 83 15 17 18 19 19 18 17 122 124 125 125 125 124 122 134 136 137 137 136 135 133 SV 4 1-1 -2-3 -4-5 8.5 8.9 9.3 9.7 9.9 1.1 1.3 1.3 1.7 11.2 11.6 11.8 12.1 12.1 11.7 12.2 12.7 13.1 13.4 13.6 13.6 12.9 13.5 14. 14.4 14.6 14.8 14.8 17.2 17.8 18.3 18.7 18.9 18.9 18.8 21.8 22.4 22.8 23.1 23.1 22.9 22.6 24.1 24.6 25. 25.1 25. 24.7 24.2 25.1 25.7 25.9 25.9 25.7 25.3 24.8 SV 5 1-1 -2-3 -4-5 51 53 54 56 57 58 58 62 64 66 67 68 69 69 71 73 75 76 78 78 78 78 81 83 84 85 86 86 17 11 112 113 114 114 113 143 145 147 148 148 147 146 166 168 17 17 17 168 167 183 185 186 186 185 184 182 SV 5 1-1 -2-3 -4-5 11.6 12.1 12.7 13.1 13.5 13.8 14. 14. 14.6 15.2 15.7 16.1 16.4 16.5 15.9 16.7 17.3 17.8 18.2 18.4 18.5 17.6 18.4 19. 19.6 19.9 2.1 2.2 23.4 24.3 24.9 25.4 25.7 25.7 25.6 29.6 3.5 31.1 31.4 31.4 31.2 3.7 32.7 33.5 34. 34.1 34. 33.6 33. 34.2 34.9 35.3 35.3 35. 34.5 33.7 SV 6 1-1 -2-3 -4-5 68 71 73 75 76 77 78 83 86 88 9 92 93 93 95 98 11 13 14 15 15 15 18 111 113 115 115 115 144 147 15 152 153 153 152 191 195 197 198 198 197 196 222 226 227 228 227 226 223 245 248 25 25 248 246 243 SV 6 1-1 -2-3 -4-5 15.5 16.3 17. 17.6 18.1 18.5 18.7 18.7 19.6 2.4 21.1 21.6 22. 22.2 21.3 22.3 23.2 23.9 24.4 24.7 24.8 23.6 24.6 25.5 26.2 26.7 27. 27. 31.4 32.6 33.5 34.1 34.5 34.5 34.3 39.7 4.9 41.7 42.1 42.1 41.8 41.2 43.9 45. 45.6 45.8 45.6 45. 44.2 45.8 46.8 47.3 47.3 47. 46.2 45.2 Correction factors When dimensioning, multiply the evaporating capacity by the correction factor k, dependent on the subcooling t sub just ahead of the valve. The corrected capacity can then be found in the capacity table. R717 (NH 3) R22 t K 2 4 1 15 2 25 3 35 4 45 5 k 1.1 1..98.96.94.92.91.89.87.86.85 t K 2 4 1 15 2 25 3 35 4 45 5 k 1.1 1..96.93.9.87.85.83.8.78.77 AF24258644423en-78 31

Float valves, types SV 4, SV 5 and SV 6 Construction / function No. Part Material DIN / EN 1 Bottom flange for float valve Steel P275NL1 EN128-3 2 Tube for valve body Steel TTST35N DIN17173 3 Connection for float house Steel TTST35N DIN17173 4 Top cover for float valve Steel P275NL1 EN128-3 5 Valve housing Low temperature, cast iron (spherical) 6 Spindle Stainless steel 7 Spring Steel 8 Sealing ring Nylon (PA 6) 9 O-ring Cloroprene (Neoprene) 1 Distance ring Nylon (PA 6) 11 Packing ring Nylon (PA 6) 12 Packing box Steel 13 Cap Steel 14 Float Stainless steel 15 Adjusting ring Steel 16 Pin Steel 17 Fork for spindle Steel 18 Screw Steel 19 Locking ring Steel 2 Pin Steel EN-GJS-4-18-LT EN1563 32 AF24258644423en-78

Float valves, types SV 4, SV 5 and SV 6 Construction / function (cont.) No. Part Material DIN / EN 21 Pin Steel 22 Cover with guide Steel 23 Screw Steel 24 Plug Steel 25 Gasket Non asbestos 26 Gasket Aluminium 27 Valve cone (guide) with pin Steel / Nylon (PA6) 28 Valve cone Teflon (PTFE) 29 O-ring Cloroprene (Neoprene) 3 Nozzle Teflon (PTFE) 31 Gasket Non asbestos 32 Filter Steel / Stainless steel 33 Spring Steel 34 Cover for filter Steel 35 Gasket Aluminium 36 Nipple Steel 37 Union nut Steel 38 Gasket Aluminium 39 Welding nipple Steel 4 Locking ring Steel 41 Ring Nylon (PA6) 42 Pin Steel 43 Screw Stainless steel A2-7 44 Screw Stainless steel A2-7 45 Washer Steel 46 Screw Stainless steel A2-7 AF24258644423en-78 33

Float valves, types SV 4, SV 5 and SV 6 Construction / function (cont.) SV 4-6 float valves are for low pressure operation only. They are used for flooded evaporators, where only slight variations in the liquid level can be accepted. When the liquid level decreases, the float moves downwards. This opens the orifice (pos. 7) and the amount of liquid injected is increased. The liquid inlet line should be dimensioned in such a way that acceptable liquid velocities and pressure drops are obtained. This is particularly important when the liquid is only slightly subcooled, since valve capacity is reduced considerably if flashgas occurs in the liquid ahead of the orifice. The flashgas quantity which occurs on expansion is removed through the balance pipe. On refrigeration plant using fluorinated refrigerants, slight subcooling and a large pressure drop can result in a flashgas quantity of approx. 5% of the injected liquid quantity. Therefore the pressure drop in this balance pipe must be kept at a minimum, otherwise there is a risk that: the liquid level in the evaporator will vary to an unacceptable degree as a function of evaporator load the absolute difference between the liquid level of the evaporator and the SV valve If too large amounts of flash gas are created it is recommended to use the external injection connection or let the liquid expand directly into the surge drum. See application drawings 3 and 4. See instruction for SV 4-6 for: Cleaning of strainer Change of orifice Change of valve plate 34 AF24258644423en-78

Float valves, types SV 4, SV 5 and SV 6 Application The liquid expands into the float housing The liquid expands into the float housing 1) 2) Direct liquid injection into the float housing 4 pcs. M6 screws (pos. 23) are removed, and pos. 24 remains blanked off. This leaves four holes through which liquid expands directly. Note: If the capacity is too high, only remove two or three screws. Pos. 23 and 24, see Construction & Function. 4 pcs. M6 screws (pos. 23) are removed, and pos. 24 remains blanked off. This leaves four holes through which liquid expands directly. Note: If the capacity is too high, only remove two or three screws. Pos. 23 and 24, see Construction & Function. The liquid expands into the evaporator 3) 4) The liquid expands directly into the surge drum Used in large evaporators with long pipe lines. pos. 24 is removed and weld connection is mounted pos. 23 remains screwed Pos. 23 and 24, see Construction & Function. 4 pcs. M6 screws (pos. 23) are removed, and pos. 24 remains blanked off. This leaves four holes through which liquid expands directly. Note: If the capacity is too high, only remove two or three screws. Pos. 23 and 24, see Construction & Function. AF24258644423en-78 35

Float valves, types SV 4, SV 5 and SV 6 Dimensions and weight Weight: 19.6 kg Weight: 9.7 kg Weight: 3.1 kg 36 AF24258644423en-78

Float valves, types SV 4, SV 5 and SV 6 Ordering Regulator The code nos. stated apply to float valves types SV 4, 5 and 6 with two 1" weld connections for balance tubes and two ½" weld joints for liquid and evaporator connections respectively. Valve type Orifice diameter Code no. Code no. Rated capacity in kw 1) without housing 2) R717 R22 R134a R44A SV 4 3. mm 27B224 27B214 12 21. 16.4 15.4 SV 5 3.5 mm 27B225 27B215 138 28.6 22.3 21. SV 6 4. mm 27B226 27B216 186 38.3 29.9 28.1 1) The rated capacity refers to the valve capacity at evaporating temperature t c = 5 C, condensing temp. t c = 32 C and liquid temperature t l = 28 C. 2) Flange for mounting without housing Code no. 27B227. Spare parts and accessories Smaller orifices for the SV 4-6 are available as spare parts and can be mounted in the SV 4-6 if smaller capacities are required. Seal kit: 27B27 Other spare parts: See spare parts catalogue Special orifice code no. and rated capacities for SV 4-6 Orifice diameter k v Capacities at -1 C evaporating temperature at pressure drop across valve P bar R717 R22 Code no. 1) 4 7 1 4 7 1 1. mm.26 9 12 13.5 1.6 2.2 2.4 27B28 1.5 mm.6 21 27 29 3.8 4.9 5.2 27B281 2. mm.1 35 46 5 6.3 8.3 9 27B282 2.5 mm.16 56 7 81 1 13 15 27B283 2.8 mm.2 7 87.5 11 12 16 18 27B284 1) The code no. includes orifice and all necessary gaskets Note: The SV 4-6 mounted with special orifice diameter 2.5 mm is recommended as pilot float valve for the servo-operated level regulators type PMFL for higher capacities. AF24258644423en-78 37

Shut-off Liquid level and regulating valves for Types Industrial PMFL / Refrigeration PMFH and SV Contents Page Features... 41 Approvals... 41 Technical data... 42 Design / Function PMFL.... 43 SV floats for PMFL... 44 Design / Function PMFH... 45 Design / Function SV 1-3... 46 Sizing... 46 Capacity in kw... 47 Material specification............................................................................. 49 Ordering... 5 Dimensions and weights.... 52 AI24286443737en-21 217.8 AF24258644423en-78 39

Shut-off Liquid level and regulating valves for Types Industrial PMFL / Refrigeration PMFH and SV For modulating liquid level control in refrigeration, freezing and air conditioning plant, a system comprising a liquid level regulating valve type PMFL or PMFH, controlled by a pilot float valve type SV, is used. PMFL and SV systems are used on the evaporator side. PMFH and SV systems are used on the condenser side. The system is suitable for use with ammonia or fluorinated refrigerants. The PMFL and PMFH can be used in liquid lines to or from evaporators separators intermediate coolers condensers receivers Modulating liquid level regulation provides liquid injection that is proportional to the actual capacity. This gives a constant amount of flashgas, thus ensuring stable regulation and economic operation because variations in pressure and temperature are held to a minimum. Features Applicable to HCFC, HFC and R717 (Ammonia) PMFL / PMFH are based on PM valve family housings Same flange programme as for PM valve series Valve housing in low temperature cast iron (spherical) - EN GJS 4-18-LT Manual operation possible Position indicator available Pressure gauge connection to monitor inlet pressure Simple installation Main valve top cover can be located in any position without affecting the function Classification: DNV, CRN, BV, EAC etc. To get an updated list of certification on the products please contact your local Danfoss Sales Company Approvals Pressure Equipment Directive (PED) The PMFL / PMFH valves are approved and CE marked in accordance with Pressure Equipment Directive - 97/23/EC. For further details / restrictions - see Installation Instruction. PMFL/PMFH-valves* Nominal bore DN 25 (1 in) DN 32-125 mm (1 1 4 5 in) DN 15 mm (6 in) Classified for Fluid group I Catagory Article 3, paragraph 3 II III * CE is only applicable to the EN GJS 4-18-LT AF24258644423en-78 41

Liquid level regulating valves, types PMFL / PMFH and SV Technical data Refrigerants Applicable to HCFC, HFC and R717 (Ammonia). Max. working pressure PMFL / H: MWP = 28 bar SV: MWP = 28 bar Max. test pressure PMFL / H: Max. test pressure = 42 bar SV: Max. test pressure = 42 bar Temperature of media: -6 12 C. Note: Max. working pressure is limited to MWP = 21 bar when media temperatures are: below -2 C for valves made of GGG-4.3 and below -1 C for valves made of GG-25. 42 AF24258644423en-78

Data sheet Liquid level regulating valves, types PMFL / PMFH and SV Design/Function PMFL 6. Seal plug 1. Valve spindle 12. Valve seat 19. Valve body 19a. Channel in valve body 2. Bottom cover 23. Main spring 24. Servo piston 24a. Channel in servo piston 3. Top cover 3a.b.c. Channels in top cover 31. Valve cone 43. Supplementary spring 44. Manometer connection 53. Spindle cap 6. Setting spindle 73. Pilot connection PMFL When the liquid level inside the float drops, the float orifice opens. This relieves the higher pressure, ps, acting on the servo piston to the low pressure side causing the PMFL to open. Variations in liquid level will result in variations To SV float in pressure over the piston and variation in the amount of liquid injected. It is important to choose the correct spring set when designing the plant. The spring set should be selected from the table below: Subcooling Pressure difference over main valve bar psi bar psi K F 4 15 58 218 1.2 4. 17 58 8 14 Normal spring set Weak spring set 8 4 14 72 Strong spring set The setting spindle, pos. 6, has not been set from factory. It is imperative that the setting spindle is adjusted before the valve is put into operation. The outer spring, pos. 23, is preset and the inner spring, pos. 43, is adjusted when turning the spindle. The following tables shows the adjustment of the inner spring in number of turns of the spindle as a function of valve size, spring type and pressure difference: C/w normal (factory mounted) spring set, subcooling -8 K ~ -14 F PMFL Pressure difference (Dp) over PMFL in bar or psi < 5 bar 5 8 bar 8 1 bar 1 12 bar > 12 bar < 72 psi 72 116 psi 116 145 psi 145 174 psi > 174 psi 8 No tension 2 3 3 4.5 4.5 6 ca. 7 125 No tension 3 5 5 7 7 9 ca. 1 2 No tension 3 5 5 7 7 9 ca. 1 3 No tension 4 6 6 9 9 12 ca. 14 C/w strong spring set, subcooling 8-4 K ~ 14-72 F PMFL Pressure difference (Dp) over PMFL in bar or psi 6 9 bar > 9 bar 87 131 psi > 131 psi 8 4 Max. tension 125 6 Max. tension PMFL C/w stong spring set, subcooling 8-4 K ~ 14-72 F Pressure difference (Dp) over PMFL in bar or psi 6 16 bar 87 232 psi 3 Spring must always be set to max. tension C/w weak spring set, low pressure plants PMFL Pressure difference (Dp) over PMFL in bar or psi 1.2 1.8 bar 1.8 2.5 bar 2.5 3 bar 3 4 bar 17 26 psi 26 36 psi 36 43 psi 43 58 psi 8 No tension 3 4 4 6 Max. tension 125 No tension 4 6 6 8 Max. tension 2 No tension 4 6 6 8 Max. tension 3 No tension 5 7 5 7 Max. tension AF24258644423en-78 43

Liquid level regulating valves, types PMFL / PMFH and SV Design/Function (continued) The values for spindle turns are an indication for an initial setting only. If a position indicator is used, a more precise modulation can be achieved when fine tuning the valve setting. If the PMFL is not opening fully, the spring tension must be reduced. If the PMFL is operating in a ON/OFF function, the spring tension should be increased. The condenser pressure will have an effect on the fine tuning and large variations in condensing pressure might call for readjustment. The subcooling is measured just before the PMFL and the pressure difference is for the valve only excluding piping and armatures. The PMFL can be used together with SV 4 as a pilot valve. PMFL function example The orifices determines the k v (C v ) value of the pilot and the following table can be used as an initial selection guide: PMFL 8 X 125 X 2 X SV 4-6 Ø 2.5 Ø 3 (SV 4) 3 X The final choice of orifice may vary depending on refrigerant and pressure levels. Smaller pressure levels needs a bigger orifice. Pressure difference levels below 3 bar (43 psi) need SV 4-6 with Ø3 mm orifice. From compressor To compressor From evaporator Condenser Alarm Alarm float switch Overflow valve Liquid level Through type receiver Filter Oil drain valve To evaporator SV floats for PMFL SV 4 can be used for PMFL low pressure control system. The float must be connected as shown. Note: Only one inlet connection possible for SV 4. Inlet to SV 4 from PMFL 44 AF24258644423en-78

Data sheet Liquid level regulating valves, types PMFL / PMFH and SV Design/Function PMFH 3. Manometer connection 6. Seal plug 1. Valve spindle 19. Valve body 19a. Channel in valve body 2. Bottom cover 21a. Channel in servo piston 23. Main spring 24. Servo piston 3. Top cover 3a.b.c. Channels in top cover 31. Valve cone 53. Spindle cap 6. Manual opening 73. Pilot connection PMFH If the liquid level inside the SV float rises, the float orifice opens and relieves pressure through the pilot line to the top of the PMFH, increasing the pressure, ps, moving the pushrod downwards and opening the PMFH. The pilot line is connected in the topcover at SI. Override of the pilot signal can be made by using an EVM valve at SII. It is important to choose the correct spring set when designing the plant. The spring set should be selected from the table below: The PMFH can be used together with either SV 1 or 3 with the SV mounted with the bleed valve downwards, refer to the drawing below. This reverses the opening so that rising float opens the orifice. Pressure difference over main valve bar psi bar psi 4.5 65 > 4.5 > 65 Weak spring set Normal spring set PMFH function example From low stage compressor(s) To high stage compressor(s) From high stage compressor(s) Alarm float switch Alarm Condenser S-connection SV 3 (1) To low stage separator Intermediate pressure vessel Liquid trap receiver Filter P-connection To compressor cooling High pressure float system (for explanatory purposes only) AF24258644423en-78 45

Liquid level regulating valves, types PMFL / PMFH and SV Design / Function SV 1-3 SV 1-3 float has 2 different pilot connections: S-port (series connection with PMFH) or P-port (parallel connection with the PMFH). P-port: When using the P-port, it is possible to force open the PMFH valve to a fully open position. This is practical for service purposes or to confirm if the float has sufficient capacity for the PMFH and the operating conditions. However, when P-port connection is used it is possible to overfill a system due to constant bleeding or unautorised tampering. In this case, it is advisable to introduce a shut off when the liquid level reaches a preset point. Shut off can be done via an electrical switch if an EVM valve is mounted in the SII port in the top of the PMFH. It is only advisable to use the P-port at low pressure difference. S-port: The S-port offers the advantage of a preorifice which divides the pressure drop and any wear possibility due to cavitation. S-port connection must be used at high pressure differences, dp > 1 bar (145 psi). The k v (C v ) value of the SV is higher using P-port than using S-port. A higher P-band can thus be obtained. Sizing Sizing example for PMFL Refrigerant R 717 (NH 3) Evaporator capacity Q e = 6 kw Evaporating temperature t e = -1 C ( p e = 2.9 bar abs.) Condensing temperature t c = 3 C ( p c = 11.9 bar abs.) Liquid temperature ahead of valve t l = 2 C at max. capacity Subcooling t sub = t c - t l = 3 C - 2 C = 1 K Calculations do not take into account pressure loss in pipelines. Pressure drop across valve p = p c - p e = 11.9 bar - 2.9 bar = 9 bar Correction factor for 1 K subcooling.98 Corrected capacity 6 kw.98 = 588 kw The corrected capacity can be found in the capacity table. It will be seen from the table that valve type PMFL 8-4 should be chosen. Refering to ordering table, code number 27F53 can be found. For details of flanges, accessories and pilot valve, see the ordering table. Since p = 9 bar and t sub = 1 K, it will be seen from the C/w strong spring set for PMFL that a STRONG spring set must be used. The pilot line is connected to SV at connection S. In the ordering table the code number for the spring set can be found: 27F118. Sizing example for PMFH Refrigerant R 717 (NH 3) Evaporator capacity Q e = 22 kw Evaporating temperature t e = -1 C ( p e = 2.9 bar abs.) Condensing temperature t c = 3 C ( 11.9 bar abs.) Liquid temperature ahead of valve t l = 2 C Subcooling t sub = t c - t l = 3 C - 2 C = 1 K Calculations do not take into account pressure loss in pipelines. Pressure drop across valve p = p c - p e = 11.9 bar - 2.9 bar = 9 bar Correction factor for 1 K subcooling.98 Corrected capacity 22 kw.98 = 2156 kw The corrected capacity can be found in the capacity table. It will be seen from the table that valve type PMFH 8-7 should be chosen. In the ordering table the code number for the valve can be found: 27F36 for CE-approved valve. For details of flanges, accessories and pilot valve, see the ordering table. Correction factors When dimensioning, multiply the evaporator capacity by a correction factor k dependent on the subcooling t sub just ahead of the valve. The corrected capacity can then be found in the capacity table. R 717 (NH 3) t K 2 4 1 15 2 25 3 35 4 45 5 k 1.1 1..98.96.94.92.91.89.87.86.85 R 22 t K 2 4 1 15 2 25 3 35 4 45 5 k 1.1 1..96.93.9.87.85.83.8.78.77 46 AF24258644423en-78

Data sheet Liquid level regulating valves, types PMFL / PMFH and SV Capacity in kw Type Evaporating temperature te [ C] PMFL 8-1 1-1 -2-3 -4-5 PMFL 8-2 1-1 -2-3 -4-5 PMFL 8-3 1-1 -2-3 -4-5 PMFL 8-4 1-1 -2-3 -4-5 PMFL 8-5 1-1 -2-3 -4-5 PMFL 8-6 1-1 -2-3 -4-5 PMFL 8-7 1-1 -2-3 -4-5 PMFL 125 1-1 -2-3 -4-5 PMFL 2 1-1 -2-3 -4-5 PMFL 3 1-1 -2-3 -4-5 Rated capacity in kw at pressure drop across valve p bar Type Evaporating temperature te Rated capacity in kw at pressure drop across valve p bar.8 1.2 1.6 2. [ C] 4. 8. 12. 16. 5 51 53 54 55 56 56 8 83 85 86 88 89 9 127 131 134 137 139 14 139 26 214 219 222 224 223 219 325 336 344 347 345 338 327 565 584 591 587 571 546 52 881 99 91 887 844 794 75 14 145 146 145 14 133 126 225 232 234 231 222 211 2 342 353 356 35 337 319 33 R 717 (NH 3 ) R 717 (NH 3 ) 6 62 64 65 66 67 67 97 11 13 15 16 17 16 154 159 163 164 167 166 164 25 259 264 267 267 263 257 394 46 413 414 47 396 383 682 7 75 692 666 636 68 16 18 17 13 975 921 875 169 173 174 17 163 155 148 271 277 278 271 259 248 234 411 421 421 41 391 371 354 69 71 73 74 75 79 75 111 115 118 119 12 12 119 176 182 186 188 188 187 184 286 295 31 33 31 295 288 449 463 47 468 458 444 429 773 792 795 777 746 712 684 119 121 119 115 19 13 984 191 195 195 193 182 173 166 36 312 312 33 289 275 263 465 474 473 459 437 416 398 76 79 81 82 83 86 82 123 127 13 132 133 132 131 194 21 25 27 27 25 21 316 327 333 334 33 323 315 496 511 518 514 52 486 47 851 869 871 85 816 781 751 13 131 13 125 119 113 18 21 214 214 28 199 19 183 336 342 341 331 316 32 29 499 518 517 51 478 456 438 PMFL 8-1 1-1 -2-3 -4-5 PMFL 8-2 PMFH 8-2 PMFL 8-3 PMFH 8-3 PMFL 8-4 PMFH 8-4 PMFL 8-5 PMFH 8-5 P MFL 8-6 PMFH 8-6 PMFL 8-7 PMFH 8-7 PMFL 125 PMFH 125 PMFL 2 PMFH 2 PMFL 3 PMFH 3 1-1 -2-3 -4-5 1-1 -2-3 -4-5 1-1 -2-3 -4-5 1-1 -2-3 -4-5 1-1 -2-3 -4-5 1-1 -2-3 -4-5 1-1 -2-3 -4-5 1-1 -2-3 -4-5 1-1 -2-3 -4-5 PMFH 5 1-1 -2-3 -4-5 14 17 11 111 111 111 19 167 172 176 177 177 175 173 264 271 276 278 276 272 267 427 438 444 445 439 429 42 667 679 685 68 666 649 632 113 113 113 111 18 15 12 169 167 166 163 158 153 149 277 277 277 272 265 257 249 441 442 44 433 421 48 396 669 669 666 655 636 617 599 17 17 16 14 11 983 954 14 142 143 143 143 142 14 224 227 228 238 227 225 222 353 356 357 356 353 349 343 571 573 572 568 561 552 543 887 883 874 864 852 837 823 149 146 143 141 138 136 134 222 215 29 25 21 197 194 365 357 35 343 337 332 326 581 568 555 545 536 526 517 881 86 84 824 81 796 782 141 137 134 131 129 127 124 161 165 166 166 165 162 16 257 264 265 264 262 258 253 44 414 416 413 47 4 393 651 664 665 657 647 635 624 11 12 12 1 984 966 948 167 169 167 164 161 157 154 248 25 247 241 235 23 225 41 414 49 41 392 384 377 653 659 651 637 624 611 599 988 998 985 965 943 924 95 158 159 157 154 15 147 144 176 178 179 179 177 175 281 284 285 284 281 277 44 444 445 443 438 431 74 79 79 74 696 685 18 18 18 17 16 14 178 178 177 176 173 171 261 261 261 259 255 251 435 435 434 43 424 418 692 692 69 683 674 664 15 15 14 13 12 1 167 167 167 165 163 16 AF24258644423en-78 47

Liquid level regulating valves, types PMFL / PMFH and SV Capacity in kw (continued) Type Evaporating temperature te [ C] PMFL 8-1 1-1 -2-3 -4-5 PMFL 8-2 1-1 -2-3 -4-5 PMFL 8-3 1-1 -2-3 -4-5 PMFL 8-4 1-1 -2-3 -4-5 PMFL 8-5 1-1 -2-3 -4-5 PMFL 8-6 1-1 -2-3 -4-5 PMFL 8-7 1-1 -2-3 -4-5 PMFL 125 1-1 -2-3 -4-5 PMFL 2 1-1 -2-3 -4-5 PMFL 3 1-1 -2-3 -4-5 Rated capacity in kw at pressure drop across valve p bar Type Evaporating temperature te Rated capacity in kw at pressure drop across valve p bar.8 1.2 1.6 2. [ C] 4. 8. 12. 16. 11 12 12 12 13 13 13 18 19 2 2 21 21 21 29 3 31 32 33 34 34 47 49 51 52 54 54 55 74 78 8 83 84 84 84 129 135 14 142 143 141 137 22 211 216 218 215 29 2 321 336 346 352 352 346 335 515 538 555 563 561 55 532 782 819 843 855 851 833 84 13 14 15 15 15 16 16 22 23 24 24 25 25 25 35 36 37 39 39 4 4 57 59 61 63 64 64 64 89 94 96 99 99 99 97 156 162 167 168 167 163 158 242 251 256 255 249 24 23 386 42 412 415 41 399 386 618 645 66 663 653 635 612 94 98 1 11 99 961 925 15 16 17 17 17 18 18 25 26 27 28 28 28 28 39 41 43 44 44 45 44 64 67 7 71 72 72 71 12 17 11 112 112 11 18 177 184 188 189 186 181 175 273 283 286 283 275 265 254 437 455 464 464 455 442 426 7 728 742 74 725 72 677 16 111 113 112 11 16 12 R 22 R 22 17 18 18 19 19 19 19 27 29 3 3 31 31 31 43 46 47 48 48 49 48 71 74 77 78 78 78 77 112 117 121 122 122 12 117 194 22 26 25 22 196 189 299 38 311 37 298 286 275 479 498 57 55 494 478 461 767 796 81 85 786 76 732 117 121 123 122 119 115 111 PMFL 8-1 1-1 -2-3 -4-5 PMFL 8-2 PMFH 8-2 PMFL 8-3 PMFH 8-3 PMFL 8-4 PMFH 8-4 PMFL 8-5 PMFH 8-5 PMFL 8-6 PMFH 8-6 PMFL 8-7 PMFH 8-7 PMFL 125 PMFH 125 PMFL 2 PMFH 2 PMFL 3 PMFH 3 1-1 -2-3 -4-5 1-1 -2-3 -4-5 1-1 -2-3 -4-5 1-1 -2-3 -4-5 1-1 -2-3 -4-5 1-1 -2-3 -4-5 1-1 -2-3 -4-5 1-1 -2-3 -4-5 1-1 -2-3 -4-5 PMFH 5 1-1 -2-3 -4-5 22 23 24 25 25 25 24 36 38 39 4 4 4 39 57 6 62 63 63 62 61 94 98 11 12 11 99 97 147 153 157 157 156 152 148 251 26 263 262 257 249 241 381 39 393 389 378 366 353 62 639 647 643 628 69 589 99 12 13 12 1 969 937 15 155 156 155 151 147 142 241 248 25 248 242 234 226 28 29 3 3 3 3 29 46 47 48 48 48 48 47 72 74 76 76 76 75 73 118 121 123 123 122 12 117 184 188 19 189 187 184 179 31 314 315 313 38 32 294 466 467 465 461 454 444 433 763 77 771 767 755 739 72 122 123 123 122 12 117 115 185 186 186 185 182 178 173 295 297 297 295 29 284 277 31 32 32 32 32 32 31 51 52 52 52 52 51 49 8 82 82 82 81 79 77 13 133 133 132 13 127 124 22 25 25 23 199 195 189 341 343 341 335 328 32 312 51 51 54 495 483 471 458 837 842 835 821 84 784 762 133 134 133 131 128 125 121 22 23 21 198 193 189 183 324 325 321 316 39 31 293 32 33 34 34 33 32 32 52 53 54 54 53 52 51 82 84 85 85 83 81 79 133 136 138 137 134 131 127 26 211 212 21 26 2 194 345 352 353 348 34 331 321 515 524 523 516 53 489 473 847 864 865 853 834 81 785 135 138 138 136 133 129 125 25 28 29 26 21 195 189 327 333 333 329 321 312 32 48 AF24258644423en-78

Data sheet Liquid level regulating valves, types PMFL / PMFH and SV Material specification PMFL PMFH Material specification for PMFL / PMFH valves No. Part Material DIN/EN ISO ASTM 2 Gasket between body and flange Non-metal Non-asbestos 3 Bolts for flange Stainless steel A2-7 A2-7 Type 38 4 Flange PM 5-65 Steel RSt. 37-2, 125 Fe36 B, 63 Grade C, A 283 6 Plug Steel 9SMn28 1651 1 Valve spindle Steel 9SMn28 1651 12 Valve seat Teflon [PTFE] 19 Valve body Low temperature cast iron (spherical) 2 Bottom cover Low temperature cast iron (spherical) 23 Spring Steel EN-GJS-4-18-LT EN-1693 EN-GJS-4-18-LT EN-1693 Type 2 R683/9 Type 2 R683/9 1213 SAE J 43 1213 SAE J 43 24 Servo piston Cast iron GG-25 Grade 25 Class 4B 3 Cover Low temperature cast iron (spherical) 31 Trottle cone Steel 9SMn28 1651 32 Gasket between body and bottom cover 34 Bolts for top and bottom cover Non-metal Non-asbestos 41 Gasket Non-metal Non-asbestos 43 Spring Steel EN-GJS-4-18-LT EN-1693 Type 2 R683/9 1213 SAE J 43 Stainless steel A2-7 A2-7 Type 38 53 Spindle cap Steel 9SMn28 1651 6 Setting / manual operating spindle Steel 9SMn28 1651 73 Pilot connection Steel 9SMn28 1651 Type 2 R683/9 Type 2 R683/9 Type 2 R683/9 1213 SAE J 43 1213 SAE J 43 1213 SAE J 43 AF24258644423en-78 49

Liquid level regulating valves, types PMFL / PMFH and SV Ordering Rated capacity in kw (1 kw =.284 TR) Valve type R 717 R 22 R 134a R 44A R 12 R 52 PMFL/H 8-1 PMFL/H 8-2 PMFL/H 8-3 PMFL/H 8-4 PMFL/H 8-5 PMFL/H 8-6 PMFL/H 8-7 PMFL/H 125 PMFL/H 2 PMFL/H 3 PMFL/H 5 139 29 348 558 835 1395 28 348 558 835 139 27.8 41.8 7 15 174 278 435 7 15 174 278 22.1 35.3 53.1 88.9 133 221 353 552 889 1333 221 33 49.7 82.7 124 27 33 569 831 1243 268 33 17.4 27.8 41.8 7 15 174 278 435 7 15 174 3 45.2 75.2 113 188 3 47 755 113 188 3 The rated capacity is given at evaporating temperature t e = 5 C, condensing temperature t c = 32 C and liquid temperature t l = 28 C. Main valve Valve type PMFL 8-1 PMFL 8-2 PMFL 8-3 PMFL 8-4 PMFL 8-5 PMFL 8-6 PMFL 8-7 PMFL 125 PMFL 2 PMFL 3 Code no. EN GJS 4-18-LT 27F354 27F355 27F356 27F357 27F358 27F359 27F36 27F361 27F362 27F363 Valve type PMFH 8-2 PMFH 8-3 PMFH 8-4 PMFH 8-5 PMFH 8-6 PMFH 8-7 PMFH 125 PMFH 2 PMFH 3 PMFH 5 Code no. EN GJS 4-18-LT 27F365 27F366 27F367 27F368 27F369 27F37 27F371 27F372 27F373 27F374 The code nos. stated apply to main valves type PMFL or PMFH incl. flange gaskets, flange bolts, blanking plug and pilot connection with Ø6.5 / Ø1 mm weld nipple. Spring set Special spring set for PMFL Subcooling tu K Pressure drop p in PMFL 4 15 bar 1.2 4 bar Spring set Pilot connection on SV 1-3 only Pos. Type PMFL -8 "STANDARD" "WEAK" P 23 + 43 8-1 8-7 8-4 "STRONG" S 125 2 3 "WEAK" 27F123 27F124 27F125 27F126 Code no. "STRONG" 27F118 27F119 27F121 Weak/Strong Special spring set for PMFH Pressure drop in PMFH p bar 1 4 Type PMFH 8.1 7 PMFH 125 PMFH 2 PMFH 3 "WEAK" Code no. 27F219 27F2191 27F2192 27F2193 5 AF24258644423en-78

Data sheet Liquid level regulating valves, types PMFL / PMFH and SV Ordering (continued) Flanges 2 ) Valve type Flange type Weld flanges Solder flanges PMFL 8 / PMFH 8 PMFL 125 / PMFH 125 PMFL 2 / PMFH 2 PMFL 3 / PMFH 3 12 3 4 1 1 1 4 23 1 1 4 1 1 2 24 1 1 2 2 25 2 2 1 2 PMFH 5 26 2 1 2 3 [in] Code no. 1 ) [in] Code no. 1 ) [mm] Code no. 1 ) 27N122 27N1225 27N123 27N2332 27N234 27N244 27N245 27N255 27N2565 27N2665 27N268 1 ) Code no. applies to one flange set consisting of one inlet and one outlet flange. 2 ) Dimension sketch see spare part catalogue. 7 8 1 1 8 27L1223 27L1229 22 28 27L1222 27L1228 1 3 8 27L2335 35 27L2335 1 5 8 27L2441 42 27L2442 2 1 8 27L2554 54 27L2554 2 5 8 27L2666 76 27L2676 Stainless steel: flanges, bolts for flanges and top and bottom covers, see spare parts catalogue. Pilot valves SV 1-3 Type Connection Code no. Float pilot valve type SV Balance tube liquid / vapour 1 in weld Pilot line SV 1: 27B221 Ø 6.5 / Ø 1 mm weld 1 ) 27B221CE 2 ) 1 ) 3 / 8 in flare connection can be supplied under code no. 27B233. 2 ) Approved and CE-marked in accordance with Pressure Equipment Directive - 97/23/EC. SV 3: 27B223 27B223CE 2 ) Pilot valves SV 4 Valve type Orifice diameter Code no. Code no. without housing 1 ) SV 4 Ø 3. mm 27B224 2 ) 27B214 2 ) 1 ) Flange for mounting without housing Code no. 27B227. 2 ) Approved and CE-marked in accordance with Pressure Equipment Directive - 97/23/EC. The code nos. stated apply to liquid level regulators type SV 4, 5 and 6 with two 1 weld connections for balance tubes and two ½ weld joints for liquid and evaporator connections respectively. Spare parts and accessories Smaller orifices for the SV 4 are available as spare parts. Seal kit: 27B27 Special orifice code no. for SV 4 Orifice diameter kv Code no. 1 ) Ø 1. mm,26 27B28 Ø 1.5 mm,6 27B281 Ø 2. mm.1 27B282 Ø 2.5 mm,16 27B283 Ø 2.8 mm.2 27B284 1 ) The code no. includes orifice and all necessary gaskets Pilot valve kits (EVM and coil) Can be screwed on to the PMFL or PMFH instead of the blanking plug. Coils, 1 W AC AC: 27B1122xx where xx can be 11 V, 6 Hz 21 22 V, 5 Hz 31 22 V, 5/6 Hz 32 24 V, 5 Hz 33 AF24258644423en-78 51

Liquid level regulating valves, types PMFL / PMFH and SV Ordering (continued) Optional accessories Description Pressure gauge connection Ø 6.5 / Ø 1 mm weld / solder Pressure gauge connection 1 4 in flare (self-closing) (Must not be used in ammonia plant) Pressure gauge connection Cutting ring connection 6 mm 1 mm Code no. 27B235 27B241 27B263 27B264 Pressure gauge connection 1 4 NPT 27B262 Manual operating unit for PMFL. Can be fitted in place of the regulator bottom plug 27F128 3 8 in flare pilot connection for SV 27B233 Dimensions and weights PMFL / PMFH Type PMFL PMFH H 1 [mm] H 2 [mm] H 3 [mm] H 4 [mm] H 5 [mm] L [mm] L 1 [mm] 1 W [mm] L 5 max. 2 W [mm] B 1 [mm] B 2 [mm] B 3 [mm] Weight excl. solenoid valve [kg] 8 66 162 79 113 176 177 16 13 14 75 87 7. 125 72 178 96 128 193 24 17 13 14 84 82 94 11.3 2 79 187 15 138 22 254 17 13 14 94 89 12 14.2 3 95 25 123 155 22 288 2 13 14 14 16 113 19.8 PMFH 5 19 227 146 176 242 342 25 13 14 127 113 135 28.3 Pilot connection (weld / solder) DANFOSS 27F692_8-217 M24 1.5 KW 32 G 3 / 8 A 6.5 / 1 AF 22 52 AF24258644423en-78

Shut-off Liquid Level and Alarms regulating valves for Types Industrial RT 28A, Refrigeration RT 281A Contents Page Features... 55 Approvals... 55 Technical data... 56 Design / Function... 57 Dimensions [mm] and weights [kg].... 58 AI23586432637en-41 216.7 AF24258644423en-78 53

Shut-off Liquid Level and Alarms regulating valves for Types Industrial RT 28A, Refrigeration RT 281A RT 28A and RT 281A are primarily used as liquid level alarms and safety switches to prevent too high a liquid level in liquid separators. Secondarily, RT 28A and RT 281A can be used as liquid level regulators where a liquid level differential of up to ±4 mm can be permitted. When used as safety switches, RT 28A and RT 281A ensure that the max. permissible refrigerant level in flooded evaporators, pump tanks or liquid separators is not exceeded. As liquid level regulators, RT 28A and RT 281A maintain a constant average refrigerant level in flooded evaporators, pump tanks or liquid separators. Features Waterproof versions, enclosure IP66 Single pole changeover switch (SPDT) suitable for AC / DC loads Interchangeable contact system Approvals CE-approved according to EN 6947-4, -1 EN 6947-5, -1 Meets the requirements of VDE 66 (VDE: Verband Deutscher Elektrotechniker) AF24258644423en-78 55

Liquid Level Alarms, types RT28A, RT281A Technical data Refrigerants Operating ranges for RT 28A R717 (NH 3), R22 and R52 "For other refrigerants, please contact Danfoss." R12-5 1 C R22 and R717 (NH 3) -5 C R52-65 -5 C Operating ranges for RT 281A R22 and R717 (NH 3) -3 2 C Ambient temperature -5 7 C Switch Single pole changeover switch (SPDT), code no. 17-4366 AC1: 1 A, 4 V Contact load Weight Alternating current Direct current 2. kg AC3: 4 A, 4 V 1 ) AC15: 3 A, 4 V DC13: 12 W, 22 V Enclosure IP66 to IEC 529. Pressure connection Max. working pressure Max. test pressure G 3 8 A with ø 6.5 / ø 1 mm weld nipple PB = 22 bar Pe = 25 bar Adsorption charge Thermostatic element 3 m capillary tube Max. permissible bulb temperature: 8 C Bulb with electric heater 1 W heater for 24 V DC or AC The heater must be constantly energised whilst the system is in operation. 1.5 m connection cable. 1 ) Max. short-time AC3 current: 28 A Liquid level differential With a steady liquid level and a liquid level variation rate of max. 15 mm/min, the differential will be approx. 1 mm on a rise in level and approx. 2 mm on a fall in level. In unfavourable operating conditions, differentials of approx. 2 mm on a rise in level and approx. 6 mm on a fall in level must be expected. Materials Gaskets are non-asbestos. Ordering RT 28A code no. 17D466 RT 281A code no. 17D4666 56 AF24258644423en-78

Liquid Level Alarms, types RT28A, RT281A Design / Function 3. Pressure connection 4. Bellows element 5. Setting disc 9. Scale 1. Loop terminal 11. Pg 13.5 screwed cable entry 12. Spring 14. Terminals 15. Spindle 16. Switch (17-43) 17. Upper guide bush 18. Contact arm 2. Lower guide bush 38. Earth terminal RT 28A and RT 281A units are based on RT 26A. The lower element is thermal and has an electrically heated bulb. As stated, the units are primarily for use as liquid level alarms and safety switches. In designing the units, emphasis was placed on the failsafe function. In the event of a defect in the thermal element, the compressor is stopped and liquid injection cut off. Restart is only possible after the defect has been rectified. This also applies in the case of loss of charge, for example if the capillary tube or heating element in the bulb is damaged, or if current to the heating element falls. The element heating or cooling signal is compared to the reference pressure and then converted to an electric on / off impulse. The regulating principle is based on the heat conduction difference between the liquid and vapour phases of the refrigerant. Note: If the evaporating temperature, and with it the reference pressure, is higher than the max. regulation range temperature, the unit will react as though the liquid level in the liquid container was too high. AF24258644423en-78 57

Liquid Level Alarms, types RT28A, RT281A Dimensions [mm] and weights [kg] Net weight 2. kg 58 AF24258644423en-78

Shut-off Sight glass and regulating valves for Type Industrial LLG 185 Refrigeration - 155 Contents Page Features... 61 Technical data... 61 Design... 62 Frostproof sight glasses... 63 Material specification............................................................................. 65 Dimensions and weights.... 66 Ordering... 67 AI176286432251en-62 218.8 AF24258644423en-78 59

Shut-off Sight glass and regulating valves for Type Industrial LLG 185 Refrigeration - 155 LLG are sight glasses in ductile steel which meets the strictest requirements on industrial and marine refrigeration installations. The sight glasses are offered in 3 different versions: with welding nipples (LLG) with stop valves equipped with caps (LLG S) with stop valves and sight adapter in acrylic glass ready for insulation on site (LLG SF). The range of sight glasses is based on 3 basic sight glasses: LLG 185, LLG 335 and LLG 74. The other standard lengths are combined by using variations of basic glass lengths. LLG produce sufficient flow areas to secure the highest possible degree of synchronous operation, and have a specially hardened reflection glass for quick reading. The front and the base frame are mounted together from the front with countersunk allen screws. This ensures easy insulation on site as well as easy inspection and service, if any. All sight glasses are equipped as standard with a built-in safety system (non return device). If a glass is damaged, the pressure of the refrigerant will activate the safety system and refrigerant loss will be limited to an absolute minimum. Features Refrigerants Applicable to HCFC, HFC and R717 (Ammonia). Temperature range -1 1 C / -14 212 F or -5 3 C / -58 86 F Maximum operating pressure: 25 bar g / 363 psi g Equipped with boron silicate glass, hardened by an accurately controlled heat treatment process Classification: CRN, EAC etc. To get an updated list of certification on the products please contact your local Danfoss Sales Company. Technical data Refrigerants Applicable to HCFC, HFC and R717 (Ammonia). For further information please see installation instruction for LLG. Flammable hydrocarbons are not recommended. For further information please contact your local Danfoss Sales Company. Temperature range The sight glasses are applicable to the above mentioned refrigerants within the temperature range of: -1 1 C / 14 212 F for the LLG types with safety system with welding nipples and the LLG S types with safety system with stop valves. -5 3 C / -58 86 F for the LLG SF types with safety system with stop valves and sight adapter (acrylic glass) and the LLG F types with safety system and sight adapter (acrylic glass). Pressure range All LLG types are designed for: Max. operating pressure 25 bar g / 363 psi g Strength test: 5 bar g / 725 psi g Leakage test: at 25 bar g / 363 psi g. AF24258644423en-78 61