ABB MEASUREMENT & ANALYTICS DATA SHEET. AP100 ph/redox (ORP) cartridge sensors with water-wash option

Similar documents
AP100 series ph/redox (ORP) cartridge sensors with water-wash option

ABB MEASUREMENT & ANALYTICS DATA SHEET series Dissolved oxygen systems

9408 Series Dissolved Oxygen Systems. Dissolved oxygen systems designed for reliable operation with minimal operating costs

9408 series Dissolved oxygen systems

ATS430 turbidity sensor Retractable insertion assembly

ABB MEASUREMENT & ANALYTICS DATA SHEET. WaterMaster FEW530 Electromagnetic water meter

7600 series ph / Redox (ORP) electrode system

Dissolved Oxygen Cartridge Electrode Systems

UKAS calibration laboratory 8809 Temperature, pressure and electrical signals calibration guide

Series 6517 Katharometers. The ideal equipment for Process Monitoring and Control. Robust no moving parts. Designed for continuous industrial use

Navigator 600 Silica analyzers

Premium Series. Economical Price & Reliable Performance. High Quality. Rust-Resistant. Long Life. Tamper-Resistant locking Screw.

Heavy Duty Pocket Insets for the Oil & Gas Industry

Oxygen Measurement Systems High Reliability and Wide Application Coverage

High-performance submersible pressure transmitter For level measurement Model LH-10

2600T Series Pressure Transmitters Calibration Frequency Determination

Model NDA Differential pressure transmitter. Deltapi N Series A complete range of pneumatic pressure transmitters

Armatures for analytical probes

Endura AZ40 Sensor assembly High temperature filter assembly kit

FIELD DEVICES ANALYTICAL Product Specifications

Service Calibration are you doing it properly?

Pneumatic retractable fitting for simple commercially available control units or process applications

Dissolved Oxygen Systems

Service ISO17025 explained

TEK-SUB 4800B. Submersible Level Transmitter. Flow Level Temperature Pressure Valves Analyzers Accessories TekValSys LEVEL

Calibrated or locked versions available. TREATMENT > Series MD regulators GENERAL DATA. New

Hydrostatic. Continuous level measurement. Overview Page 188 VEGAWELL 52 Page 190 VEGABAR 86, 87 Page 192 Accessory Page 196 AL-EN

CoriolisMaster mass flowmeter Diagnostics, verification and proof test

1. General safety information. 2. General product information. 3. Installation. 4. Commissioning. 5. Operation. 6. Maintenance. 7.

The benefits of the extended diagnostics feature. Compact, well-proven, and flexible

Manual retractable fitting with safe-to-operate rotary drive

SPECIFICATION // DATA SHEET WATER DRAIN VALVE AM SENSORS LTD AMS-S-084/DS/ (ISSUE 1)

PositionMaster EDP300 Extended Diagnostics. Compact, well-proven, and flexible

Type 4708 Supply Pressure Regulator

ABB measurement & analytics data sheet. JAA, JAF and JAG Pneumatic indicating controllers

Type 4708 Supply Pressure Regulator

Test pumps. Pressure sources. Good reasons for proper and reliable calibration

Pneumatic retractable fitting for use with Unical 9000 and Uniclean 900 automated control systems

Endura AZ40 Sensor assembly Smart electronics PCB

3.0 Pressure Transmitter Selection

Navigator 500 Dissolved oxygen analyzer. Measurement made easy. Accurate and reliable measurement of dissolved oxygen in high purity water

High-performance submersible pressure transmitter For level measurement Model LH-10

Type 4708 Supply Pressure Regulator

Endura AZ40 Transmitter Main board spares kit

Infrared Linescanners

C-Flow Coriolis Mass Flow Meters

Oxymax COS61/COS61D. Technical Information

Pressure Dump Valve Service Kit for Series 2300 Units

Proportional Pressure-Relief Cartridge Valve, Size 2...4

Electro-Magnetic Flowmeters Electromagnetic Sensor

AE50S Automatic Air and Gas Vent for Liquid Systems Installation and Maintenance Instructions

Pressure measurement Applying remote seal, isolation diaphragms between process fluids and transmitters

Expert Hydrostatic Level Transmitters

Inverse Prop. Pressure-Relief Cart., Size 2 4

2600T Series Pressure Transmitters Plugged Impulse Line Detection Diagnostic. Pressure Measurement Engineered solutions for all applications

ph measuring system for hygienic process applications

Sanitary pneumatic retractable fitting for use with Unical 9000 and Uniclean 900 automated control systems

Type Pressure Regulator. for increased air capacity. Fig. 1: Type Pressure Regulator. Mounting and Operating Instructions EB EN

Mounting and Operating Instructions EB EN. Type Supply Pressure Regulator. with increased air capacity

better measurement Simply a question of SCHMIDT Flow Sensor SS The cost-effective alternative in pressurised systems up to 10 bars.

INSTRUCTION MANUAL. January 23, 2003, Revision 0

CONNECTION > Super-rapid fittings Series 6000 GENERAL DATA. Fitting with connecting tube. Sprint

CCS240 and CCS241. Technical Information. Sensors for chlorine dioxide Amperometric, membrane-covered sensors for installation in the CCA250 assembly

Flow Sensors & Hydrometers Specification Sheet

Oxymax W COS41. Technical Information. Potentiostatic amperometric two-electrode sensor Long-term stable sensor for water and wastewater applications

Dissolved Oxygen Sensor

Proportional Pressure-Relief Cartridge Valve, Size 2...4

HI 2314 HI 2315 HI 23151

UNIK 5600/5700 Marine Certified Pressure Sensing Platform

AIR-SAVER G1 AIR-SAVER G2 LOCATOR-EV COMPRESSED AIR CONDENSATE MANAGEMENT AND ENERGY SAVING PRODUCTS AIR SAVING PRODUCTS

OUS31. Technical Information

ABB MEASUREMENT & ANALYTICS DATA SHEET. AK100 Series ATEX compliant gas analyzer system for hydrogen-cooled alternators

Micro Motion 3098 Gas Specific Gravity Meter

Hydraulic comparison test pump Models CPP1000-X, CPP1600-X

Smart Sensors. Pure Water and Process Measurements Smart and Efficient. THORNTON Leading Pure Water Analytics

Free Chlorine Sensor For additional information, please visit our website at

Liquid Level Controllers

Series 4000 Transmitter Analyzer Controller. Series CL4000 Chlorine Probes used with MicroChem 2

Mechanical Pressure Measurement

Mounting and Operating Instructions EB 8546 EN. Supply Pressure Regulator Type Fig. 1 Supply pressure regulators

CPVC Transition Fittings - Female Adapter. CPVC X LEAD FREE BRASS Lead Free Max working pressure F ASTM D 2846

Mounting and Operating Instructions EB 8546 EN. Type 4708 Supply Pressure Regulators. Translation of original instructions. Type Type

CSA Sample Draw Aspirator Adapter Operator s Manual

2600T Series Pressure Transmitters Calibration Frequency Determination. Pressure Measurement Engineered solutions for all applications

Oxymax H COS21D. Technical Information

High-performance submersible pressure transmitter For level measurement Model LH-20

SCAM T.P.E. WATER TREATMENT SYSTEM SWT- AP AUTOMATIC PURGE

Precision pressure sensor Basic version Model CPT6020

Expansion Thermometers Stainless Steel Series, Model 70

Inverse Proportional Pressure-Relief Cart., Size 2 4

Inflatable Packer Single & Double. Single & Double Packer Dimension. Wireline Packer. Water Testing Packer (WTP) Packer

Kube Engineering Quinn E. Eddins, B.S.E.E Phone

Inverse Proportional Pressure-Relief Cart., Size 2 4

Pressure Reducing Valve DMV 755

NHR Powder Feed Hopper

The M-Series Eletta Flow Meter High accuracy DP Flow Meter with multiple functions

Pressure Dump Valve Service Kit for Series 3000 Units

BERMAD Waterworks. Combination Air Valve. Air Valves Series. Typical Applications. Features & Benefits. Additional Features.

S261 Remote seals with capillary tube

Spiratec ST14, ST16 and ST17 Sensor Chambers and sensors

Transcription:

ABB MEASUREMENT & ANALYTICS DATA SHEET AP100 ph/redox (ORP) cartridge sensors with water-wash option

2 AP100 P H / R EDOX ( ORP ) CART RI D GE SE NSORS WITH WATE R-WASH OPTION DS/AP100-E N RE V. K Measurement made easy Tough and durable sensors for on-line ph measurement Compact 'all-in-one' cartridge design simplifies sensor replacement, minimizing downtime Detachable cable option ensures rapid and easy installation and commissioning 'Wetted' sensor ready-to-go straight from the box Low resistance 'blue-glass' version unique solution for cold water applications Flow, dip, insertion and submersible systems satisfies a wide range of applications Small-bore flow system for use on applications where only small volumes of sample are available Stainless steel flow system option for use on low conductivity samples Water-wash option minimizes maintenance where coating of the glass electrode is a problem Replaceable liquid junction maximizes sensor life and enables replacement of the electrolyte

AP100 PH/REDOX (ORP) CARTRIDGE SENSORS WITH WATER-WASH OPTION DS/AP100-EN REV. K 3 The cartridge The cartridge sensing system has a proven track record in a wide range of applications. New features such as the low resistance blue-glass and the small-bore flow version for low volume samples reinforces the performance and extends the applications that can be fulfilled using this versatile and welltested system. Manufactured in glass-coupled polypropylene, the all-in-one sensor can be supplied for flow-through, dip and submersible applications. Flow systems can be supplied with a choice of process connections and materials to meet the demands of the sample to be measured. The bayonet snap-fit enables rapid and convenient access for calibration just twist and turn and the sensor is released for easy and quick calibration. Pipeline adaptor (7670/063) is available to enable the sensor to be inserted directly into a pipe. Dip systems available in 1, 2 and 3 m (39, 78 and 117 in) lengths for use in open channels and tanks. Submersible systems available with an integral sealed connection cable enabling the sensor to be completely submerged ideal for boreholes or where there is a large rise and fall in the sample to be measured. Provision is made for a support chain to be attached to the system. A wide range of standard cable lengths is available. Water-wash options available for flow and dip systems where coating of the ph glass causes maintenance issues. Water-wash has proven very successful in many applications. Bayonet snap-fit flow system Detachable cables an option that makes replacing the sensor a simple, easy-to-do operation. The use of IP67 plug and socket connectors ensures that problems caused by moisture ingress do not occur and enables reliable operation in the most demanding applications. Quick-release water-wash connection

4 AP100 PH/REDOX (ORP) CARTRIDGE SENSORS WITH WATER-WASH OPTION DS/AP100-EN REV. K The cartridge Double-junction PTFE reference a key feature to minimize the risk of blocking of the junction and protect against poisoning of the electrolyte. Supplied ready-to-go fitted with a wetted teat to ensure the sensor is in optimum condition and requires no preconditioning prior to installing and commissioning. Small-bore flow systems ideal for applications where only small sample volumes are available (between 100 and 500 ml/ minute [0.176 and 0.88 pints/minute]) for continuous analysis. These flow systems are offered in a choice of two materials, stainless steel and Delrin, both widely used on low conductivity water. Being small and compact they help to keep the panel size to a minimum when used on multiparameter packages and are a very cost effective solution. Low resistance glass a unique glass designed particularly for cold water samples where conventional sensors perform sluggishly due to low sample temperatures (below 10 C down to 0 C [below 50 F down to 32 F]). This sensor is used extensively on potable water treatment works where the sample temperature is commonly below 10 C (50 F). A further benefit of the low resistance glass is improved speed of response where the sample has a low conductivity (less than 100 µs/cm and down to 20 µs/cm). Water-wash connection Water-wash systems have proven extremely successful on potable water treatment plants where iron or manganese coat the glass electrode, increasing maintenance levels. The frequency and duration of the clean is controlled via the AX400 Analyzer and during the clean cycle the current output and alarms are frozen to prevent spurious alarms. Redox (ORP) sensors supplied in flow, dip and submersible systems, with water-wash options available for flow and dip systems. They are used widely in the treatment of waste water and, in particular, for electro-plating for the treatment of cyanide and chromate waste liquor. Water-wash

AP100 PH/REDOX (ORP) CARTRIDGE SENSORS WITH WATER-WASH OPTION DS/AP100-EN REV. K 5 Reference electrode refurbishment kit To allow the maximum working life of the sensor to be achieved, a refurbishment kit is available (Part No. 7670/088). The kit contains a replacement PTFE liquid junction, a bottle of 3.5M KCl reference electrolyte solution and pipette, a liquid junction removal/refitting tool and all necessary O-rings. Systems Flow systems Many sensors are replaced because the liquid junction becomes blocked due to the nature of the sample or because the electrolyte solution is exhausted. Replacing the junction and electrolyte extends sensor life and reduces the cost of ownership. Offset ported flow system Delrin Refurbishment kit Offset ported flow system stainless steel Clamp (optional) In 3 /8 in NPT male stud couplings (not supplied) Out Recommended clamps (not supplied)

6 AP100 PH/REDOX (ORP) CARTRIDGE SENSORS WITH WATER-WASH OPTION DS/AP100-EN REV. K Systems Dip systems Submersible systems Cartridge with 7670-063 pipeline adaptor

AP100 PH/REDOX (ORP) CARTRIDGE SENSORS WITH WATER-WASH OPTION DS/AP100-EN REV. K 7 Overall dimensions Dimensions in mm (in). Ø 48 (1.875) Ø 48 (1.875) Cable 176 (7) 1 in BSP or 1 in NPT Anchor point for additional support (light chain or flexible cable) 200 (7.875) see note 86 (3.375) see note 1/2 in BSPT female thread 176 (6.92) 101 (3.97) Ø 4 8 (1.875) 76 (3) 102 (4) Note. Allow an additional 130 mm (5.125 in) for connectors and cartridge removal. Ø 27.9 (1.10) Flow systems (including water-wash versions) Submersible system Ø 48 (1.875) Dimension A (overall length) 8 2 (3.23) 1 5 7 (6.18) 7670-063 adaptor Ø 48 (1.875) 6 0 (2.36) Dimension A C763/1 1060 (41.75) C763/2 2060 (81.10) C763/3 3060 (120.50) Ø 27.9 (1.10) 11/2 in BSP thread Dip systems Bayonet cartridge with 7670-063 pipeline adapter

8 AP100 PH/REDOX (ORP) CARTRIDGE SENSORS WITH WATER-WASH OPTION DS/AP100-EN REV. K Specification non water-wash version Flow systems ph range 0 to 14 ph standard glass 0 to 10 ph low resistance glass Temperature range 0 to 100 C (32 to 212 F) standard glass 0 to 70 C (32 to 158 F) low resistance glass Pressure 0 to 100 psi at 25 C (77 F) Process connections 1/2 in or 1 in BSP 1/2 in or 1 in NPT 3 /8 in NPT (low volume version) O-ring material Viton Temperature compensation 3-wire Pt100 Material of construction Glass-coupled polypropylene Stainless steel or Delrin (low volume version) 7670-063 pipeline adaptor Material of construction Glass-coupled polypropylene Temperature range 0 to 100 C (32 to 212 F) Pressure 0 to 80 psi at 25 C (77 F) Process connection 11/2 in BSP Dip systems ph range 0 to 14 ph standard glass 0 to 10 ph low resistance glass Temperature range 0 to 100 C (32 to 212 F) standard glass 0 to 70 C (32 to 158 F) low resistance glass Fixing bracket Not supplied Immersion length 1 m (39 in), 2 m (78 in) or 3 m (118 in) O-ring material Viton Material of construction Glass-coupled polypropylene and polypropylene (dip tube) Temperature compensation 3-wire Pt100 Submersible systems ph range 2 to 12 ph Temperature range 0 to 50 C (32 to 122 F) Immersion length Dependent on cable length: Minimum cable length supplied 10 m (32.5 ft) Maximum cable length supplied 30 m (98 ft) Temperature compensation 3-wire Pt100 Material of construction Glass-coupled polypropylene Support chain Not supplied

AP100 PH/REDOX (ORP) CARTRIDGE SENSORS WITH WATER-WASH OPTION DS/AP100-EN REV. K 9 Specification water-wash version Flow systems ph range 0 to 14 ph standard glass 0 to 10 ph low resistance glass Temperature range 0 to 100 C (32 to 212 F) standard glass 0 to 70 C (32 to 158 F) low resistance glass Pressure (flow) 0 to 60 psi at 25 C (77 F) Process connections 1/2 in or 1 in BSP 1/2 in or 1 in NPT Dip systems Immersion length 1 m (39 in), 2 m (78 in) or 3 m (118 in) Material of construction Glass-coupled polypropylene and polypropylene ph range 0 to 14 ph standard glass 0 to 10 ph low resistance glass Temperature range 0 to 80 C (32 to 176 F) standard glass 0 to 70 C (32 to 158 F) low resistance glass O-ring material Viton Water supply Mains water Line pressure 1 to 4 bar Note. ABB does not supply the solenoid valve and recommends that the tubing between the valve and the sensor is 1/4 in ID PVC for both dip and flow systems. The solenoid valve must be mounted as close as possible to the ph system in order to reduce pressure loss in the supply line.

10 AP100 PH/REDOX (ORP) CARTRIDGE SENSORS WITH WATER-WASH OPTION DS/AP100-EN REV. K Ordering information AP100 ph/redox (ORP) cartridge sensor AP10 X/ X XX X XX X X Cartridge type Bayonet, cable detached (not dip type) Bayonet, cable attached (not dip type) Screw-in, cable detached Submersible * Sensor type Standard glass (0 to 100 C [32 to 212 F], 0 to 14 ph) Standard glass + water-wash (0 to 100 C [32 to 212 F], 0 to 14 ph) Low resistance glass (0 to 70 C [32 to 158 F], 0 to 11 ph) Low resistance glass + water-wash (0 to 70 C [32 to 158 F], 0 to 11 ph) Redox (ORP) Redox (ORP) + water-wash Cable length No cable 1 m (39 in) cable 2 m (78 in) cable 3 m (117 in) cable 5 m (16.25 ft) cable 10 m (32.5 ft) cable (minimum length for submersible cartridge type) 15 m (48.75 ft) cable 20 m (65 ft) cable 25 m (81.25 ft) cable 30 m (97.5 ft) cable (available only for use with submersible cartridge type) For cartridge sensor only no further coding options are required. For full system continue selecting options Dip type (operating temperature 0 to 80 C [32 to 176 F]) No dip tube 1 m (39 in) dip 2 m (78 in) dip 3 m ( 117 in) dip 1 m (39 in) dip + water-wash 2 m (78 in) dip + water-wash 3 m ( 117 in) dip + water-wash Flow sensor type (operating temperature 0 to 100 C [32 to 212 F]) No flow cell Bayonet 1/2 in BSP process connection glass-coupled polypropylene Bayonet 1 in BSP process connection glass-coupled polypropylene Bayonet 1/2 in NPT process connection glass-coupled polypropylene Bayonet 1 in NPT process connection glass-coupled polypropylene Screw-in 1/2 in BSP process connection glass-coupled polypropylene Screw-in 1 in BSP process connection glass-coupled polypropylene Screw-in 1/2 in NPT process connection glass-coupled polypropylene Screw-in 1 in NPT process connection glass-coupled polypropylene Bayonet 3 /8 in NPT process connection stainless steel low volume Bayonet 3 /8 in NPT process connection Delrin low volume Pipe-line adapter process connection 11/2 in BSP (bayonet fitting) Reserved 0 Manual English German French Spanish Other * Submersible cartridge type available only with either sensor type option 1 (standard glass), 3 (low resistance glass) or 5 (redox [ORP]). Submersible cartridge type available only with cable length of 10 m (32.5 ft) or over. 1 2 3 4 1 2 3 4 5 6 00 01 02 03 05 10 15 20 25 30 0 1 2 3 4 5 6 00 01 02 03 04 05 06 07 08 11 12 13 1 2 3 4 9

AP100 PH/REDOX (ORP) CARTRIDGE SENSORS WITH WATER-WASH OPTION DS/AP100-EN REV. K 11 Cartridge part number changes The number of options available in the cartridge series has been increased significantly. To accommodate the new models it has been necessary to restructure the part numbers as shown in the table below. The new part numbers must be used when ordering replacements. Old Part Number Cartridge description New part number 7670/101 Bayonet cartridge AP101/100 7670/102 Screw-in cartridge AP103/100 7670/301 Bayonet with water wash AP101/200 7670/302 Screw-in with water wash AP103/200 7670/211 Bayonet cartridge redox (ORP) AP101/500 7670/311 Bayonet cartridge redox (ORP) with water wash AP101/600 7670/212 Screw-in cartridge redox (ORP) AP103/500 7670/312 Screw-in cartridge redox with water wash AP103/600 7670/600 Submersible system with 10 m (32.5 ft) cable AP104/110 7670/601 Submersible system with 15 m (48.75 ft) cable AP104/115 7670/602 Submersible system with 20 m (65 ft) cable AP104/120 7670/603 Submersible system with 25 m (81.25 ft) cable AP104/125 7670/604 Submersible system with 30 m (97.5 ft) cable AP104/130 Sales Service

ABB Limited Measurement & Analytics Oldends Lane, Stonehouse Gloucestershire, GL10 3TA UK Tel: +44 (0)1453 826 661 Fax: +44 (0)1453 829 671 ABB Inc. Measurement & Analytics 125 E. County Line Road Warminster, PA 18974 USA Tel: +1 215 674 6000 Fax: +1 215 674 7183 abb.com/measurement We reserve the right to make technical changes or modify the contents of this document without prior notice. With regard to purchase orders, the agreed particulars shall prevail. ABB does not accept any responsibility whatsoever for potential errors or possible lack of information in this document. We reserve all rights in this document and in the subject matter and illustrations contained therein. Any reproduction, disclosure to third parties or utilization of its contents in whole or in parts is forbidden without prior written consent of ABB. Copyright 2018 ABB. All rights reserved. 3KXA163101R1001 DS/AP100-EN Rev. K 01.2018