SAMPLING GUIDELINES FOR THE BI-AIR FILTER CASSETTE

Similar documents
3190A NEO-ANGLE DOOR INSTALLATION INSTRUCTIONS. Series MODEL NO

AirCheck Kit Model K901

Technical Service Bulletin June 2015 TSB122.06

B. Assemble the Method-25 sample train with a heated probe/filter.

TATTVAM ENVIRONMENTAL AND ENGINEERING SOLUTIONS, LLC. Indoor Air Quality Report for Weston Public Schools Weston, CT.

WARNING! Equipment for treatment of water intended for human consumption (Directive 98/83 CE).

Experiment 18 Properties of Gases

275 RID Assembly Instructions

PO Box 370 Phone: Swansea NSW 2281 Fax: AUSTRALIA Mobile: Web:

Met One E-BAM Particulate Monitor

Attachment C. Standard Operating Procedures. AMBIENT AIR MONITORING PROGRAM for the 130 LIBERTY STREET DECONSTRUCTION PROJECT

200 / 300 Upgrade Kits

Productivity. Technician. Maximized. Interpretation Guide

Generating Calibration Gas Standards

CONFER ABOVE GROUND CURVE STEP / ABOVE GROUND CURVE STEP SYSTEM ASSEMBLY AND INSTALLATION MANUAL

Technical Service Bulletin Oct 2017 TSB122.07

MANTEL BIKE BOX: PACKING YOUR ROAD BIKE FOR TRANSPORT

CentriFlow Meter Integrated Air Entrainment System

PAPR Flow Tester. instructions. part no WARNING

IMPORTANT PLEASE READ BEFORE COMMENCING INSTALLATION

CamRT Sun Top Bimini Installation Instructions

Bulletin TCR-104 & 109 Filling and adding to the Glycol pressure system

INSTALLATION INSTRUCTIONS FOR GRT75-PF-RFS PET FOUNTAIN

CONFER IN-GROUND CURVE STEP / IN-GROUND CURVE STEP SYSTEM ASSEMBLY AND INSTALLATION MANUAL

UsER manual for Watersens ph -REDOX

PC7-C Flowmeter O2/N2O Sedation Unit Instruction Manual

Yoke Block Instruction Manual

UNIVERSAL TUBE HOLDER SYSTEM

NAVIGATOR Product demonstration prop building instructions

Fine Bubble Tube Aeration System O&M Manual INSTALLATION INSTRUCTIONS FOR THE SSI TUBE DIFFUSER

Product Information News September 26, 2003

Assembly instructions nortik scubi 2 Recreational kayak

MINIBRUTE ANNEAL TUBE STANDARD OPERATION PROCEDURE

THERMAL POLITERM WALL AND POLITERM WALL FIX APPLICATION MANUAL. POLITERM WALL / POLITERM WALL FIX. Insulation & Chemicals Division

Booster Pump PB4-60 Replacement Kits

Armfield Distillation Column Operation Guidelines

Compact Triple Cabinet Outlet Station Model B Installation and Operating Instructions

Macro-Infusion Guide

Superconducting Susceptometer (MPMS-5S) Quantum Design Room 296 (MPMS)

Exercise 2-3. Flow Rate and Velocity EXERCISE OBJECTIVE C C C

An Evaluation of the Pullman-Ermator S26 and S13 Vacuums with a Newly Patented Dust Hood

Portable Gas Monitor GX User Maintenance Manual (H4-0050)

INSTRUCTION MANUAL FOR EBA MINUTE SELF-CONTAINED SELF RESCUER (SCSR) Manual Number: NH13747 Revision: A, ECN 2384 September 7, 2001

DIY ROCKET LAUNCHER. PVC Tee (no hole) PVC Tee (with hole) 3 x 45* PVC elbow. 1 x cork. 3 x PVC endcap. 1 x bike tube valve.

CTG Certification Protocol -- Version 3.0 SUMMARY

K-STATE GRAIN QUALITY RESEARCH PROGRAM STANDARD OPERATING PROCEDURES

Installation Guide, MPower Echelon Console

Appendix B Harris County Standard Operating Procedure for Determining In Situ Hydraulic Performance of High Flow Rate Bioretention Media

MODEL #7100X A-FRAME LADDER

TOURNAMENT ICE. 8Ft-Gold Standard Manual Score Home Air Hockey Game Assembly Instructions / Manual

Instructions in the Use of Radiation Protection. Equipment and Radiation Measuring Instruments by. Disaster Response Personnel in a Nuclear Emergency

Grow to Pro Basketball

Installation/Care/Use Manual Soft Sides Fountains with FLEXI-GUARD

SERIES 20 CHAMBERS THE RC-25 AND RC-25F CHAMBERS ASSEMBLY

LGR 7000XLi Dehumidifier

MODEL CCX-AG CURVE STEP / CURVE STEP SYSTEM

MAKE YOUR SAMPLE COUNT! A PRIMER ON COLLECTING QUALITY, REPRESENTATIVE SAMPLES

HAYWARD FLOW CONTROL FLV SERIES, PVC/CPVC FILTER VESSEL INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS

SANDBLAST HELMET EXTREME

SURROGATE POWDER AND ASHRAE-110 TESTING OF A MULTI-PURPOSE ENCLOSURE FOR WEIGHING/SIEVING/FLUID BED DRYER APPLICATIONS

Getting the Most From Your Duct Blaster

Section 3- Repair and Calibration Procedures

EcoCell Vertical Electrophoresis Unit

Airborne Activity Sampling and Monitoring at Hinkley Point A Site. David Williams, Hinkley Point A Site

830 SureFlo Soap Systems Installation Instructions. Foam Soap Cabinet... Pages 2-9 Liquid Soap Cabinet... Pages 10-19

Island Hopper Gator Monster Head & Tail Water Trampoline Attachments

Parallel Particle Impactors New Personal Samplers for Accurate Assessment of Worker Exposure to Respirable or Thoracic Dust

SAVE THESE INSTRUCTIONS DEALER/INSTALLER: GIVE TO HOMEOWNER OCEAN BLUE ABOVE GROUND POOL LADDERS

Lab 3 Introduction to Quantitative Analysis: Pumps and Measurements of Flow

Hydrotherapy Jets System for a Fiberglass Pool

Compact Triple Cabinet Outlet Station Model Installation and Operating Instructions

AIR COMPRESSOR. Failure to follow all instructions as listed below may result in electrical shock, fire, and/or serious personal injury.

SAFETY PROCEDURES MICROBIOLOGY LABORATORY (BIO310L)

Operation manual Level sensor DC-LS-50 Operation Manual Level Sensor DC-LS-50

Installation Instructions

Model: LG IP CL ADULT SUPERVISION REQUIRED

RG1200 Service and Repair Manual

THE FUNDAMENTALS OF THE AIR SAMPLER CALIBRATION-VERIFICATION PROCESS

OWNER S MANUAL. This manual contains; IMPORTANT SAFETY INFORMATION INSTALLATION INSTRUCTIONS MAINTENANCE FACTORY SERVICE REPAIR PARTS WARRANTY

INSTALLATION INSTRUCTIONS

Table of Contents Want full page pictures with most important parts labeled in the beginning.

THE RELATIONSHIP OF STRUCTURES AND AIR CONDITIONING TO INDOOR AIR QUALITY IN TWO INDOOR SWIMMING POOLS

OVERVIEW pg 3. Major Points to Consider pg 3 Minor Points to Consider pg 3. INSTRUCTIONS pg 4

AUTOVENT 4000 VENTILATOR

Operating Instructions

Tel: FAX: Risk Assessment for Exposure to Respirable Dusts Generated from the Use of Chalks and Pastels

INSTRUCTION MANUAL. PRESSUREMETER Model PENCEL. Roctest Limited 2016, All rights reserved

EFFECTS OF WATER SPRAYS AND SCRUBBER EXHAUST ON FACE METHANE CONCENTRATIONS

DuPont Personal Protection Instruction Manual for Universal Pressure Test Kit No

175 m2 (1,880 sq ft) Kit

INSTRUCTION MANUAL EBA-75 CLOSED-CIRCUIT ESCAPE RESPIRATOR (CCER) CAPACITY 3

450P AUTOMATIC PORTABLE COMPRESSOR EXTREME SERIES

Rain Barrels. Did You Know?

EMISSION CHAMBERS. Bulk and Surface Emission Detection for the RAD7 User Manual

Syringe, Distribution Valve and Infusion Pump Removal/Replacement ATTENTION SYRINGE REPLACEMENT

1020 Industrial Drive, Orlinda, TN fax

COMPACT TRIPLE WALL OUTLET STATION MODEL INSTALLATION AND OPERATING INSTRUCTIONS

Below are the instructions to build a roller-furling unit for under $10. Read the entire process before beginning the project.

HPIC D Hydrostatic Test Pump PRODUCT INFORMATION AND OPERATING INSTRUCTIONS

POLYMER TEST KIT (CLAPPER METHOD) OFI PART No

Transcription:

1 SAMPLING GUIDELINES FOR THE BI-AIR FILTER CASSETTE Full Period Consecutive Samples: This is the preferred sample collection method according to NIOSH (NIOSH Sampling Strategy Manual, 1977). It samples the entire exposure period by collecting consecutive samples. The consecutive samples allow statistical calculations to be performed, and provide multiple samples if one sample is damaged or overloaded. Full Period Single Sample: This is the second-best option. It samples the entire exposure period by collecting a single full-period sample. The single sample does not allow statistical calculations to be performed, and does not provide multiple samples if one sample is damaged or overloaded. Partial Period Consecutive Samples: This is the third-best option. Several samples, of equal or unequal duration, are collected in series, but do not cover the entire period of exposure. Grab Samples: Short-term (less than one hour) grab samples are collected at random times during an exposure period. This is the least desirable way of estimating airborne concentrations because of the high variability of the sampling data. However, this is the most common type of airborne sample collected in microbial IAQ investigations. Therefore, sampling results based on grab samples should be interpreted with caution since the typical 5-minute grab sample may either substantially underestimate or overestimate the average spore concentration. For example, if the geometric mean concentration were 1,500 spores/m 3 and the GSD were 3, there would be a 5 % probability that a 5-minute sample would result in a reported concentration as high as 20,000 spores/m 3 or as low as 200 spores/m 3. FILTER SELECTION The Bi-Air may be loaded with any standard 25 mm filter, including MCE, polycarbonate, PVC, gel (for bacteria), etc. Bi-Air cassettes typically come loaded with mixed cellulose ester (MCE) filters having a pore size of 3.0 (um) microns. When using 0-5 lpm lo-vol pumps, for example, an MCE filter with a 5.0 um pore size may be used. PUMP SELECTION The Bi-Air has a large back pressure due to the small exposed area of filter; but the small area is necessary in order to allow sampling times as short as 10 minutes, when necessary. The maximum airflow rate through a 3.0 um MCE filter is about 3.7 lpm when using a hi-vol pump. However, the airflow rate through each filter will vary due to variations in thickness, and each cassette should be calibrated. For example, three cassettes attached to the same pump may calibrate at 1.5, 1.3 and 1.4 lpm (about + 10 %). 1. Hi-Vol pump: Airflow rates up to 3.5 lpm, for 10 min to 8 hours or more. 2. 0-5 lpm SKC Lo-Vol pump: maximum of 1.0 lpm, for 30 min to about 8 hours. 3. 0-12 lpm Buck Lo-Vol pump: Airflow rates up to 2.5 lpm for up to 3 hours.

2 Airborne: Fungal Spores or Culturable Fungi using the Bi-Air Cassette Hi-Vol pump or 0-5 lpm Lo-Vol pump, Tripod, Cassette Support Plate, Tubing, 0-5 lpm rotameter, Bi-Air Cassette, Stopwatch, Sample bag, Field Sheet, Jeweler s Screwdriver, Marking Pen, Calibration Probe Method 1: Hi-Vol pump at 2-3 lpm for 10 minutes to 8 hours or longer 01 Locate the tripod away from walls/obstructions 02 Attach a cassette support plate to the top of the tripod [available from Allegro] 03 Attach plastic tubing to one of the needle valves on the pump [available from EMS] Using a Tee to install two needle valves on the pump allows multiple samples to be collected using a single pump; or allows cooling air to flow through the pump when sampling for extended periods 04 Attach a Bi-Air cassette to the tubing (resting on the support plate) & remove slotted cap 05 Calibrate the air flow rate using a 0-5 LPM rotameter with calibration probe attached The calibration probe is a wall cavity probe with the perforations removed 06 Remove the rotameter, replace the slotted cap in the fully open position, and sample The Bi-Air is unique in that the capture velocity may be varied independently of the sampling rate. When sampling outdoors in windy conditions, the slots may be partially closed to vary the capture velocity between about 4 mph and 24 mph. 07 Label = Project Number and Sample Number (A-01) Method 2: SKC 0-5 lpm Lo-Vol pump at 1 lpm for 30 minutes to 6 hours 01 Set the Lo-Vol pump on a suitable surface (table, desk, etc.) 02 Attach a Bi-Air cassette to the pump using a short piece of tubing & remove slotted cap 03 Calibrate the air flow rate to about 1.0 lpm using a 0-5 LPM rotameter 04 Remove the rotameter, replace the slotted cap in the fully open position, and sample 05 Label = Project Number and Sample Number (A-01) Method 3: Buck Basic 12 Lo-Vol pump at 1-3 lpm for 30 minutes to 3 hours 01 Attach leather or similar material to bottom of pump The Buck Basic 12 will vibrate and walk off tables, etc. 02 Set the Lo-Vol pump on a suitable surface (table, desk, etc.) 03 Attach a Bi-Air cassette to the pump using a short piece of tubing & remove slotted cap 04 Calibrate the air flow rate to about 1.5 to 2.0 lpm using a 0-5 LPM rotameter 05 Remove the rotameter, replace the slotted cap in the fully open position, and sample 06 Label = Project Number and Sample Number (A-01) REQUEST FOR ANALYSIS: Sample Type = Air; Sample Media = Bi-Air; Quantity = Sample Volume per trace; Units = L [liters]; Analysis: Trace A = Fungal Spores; Trace B = Fungi, (MEA & DG-18)

3 Airborne: Collecting Personal Samples using the Bi-Air Cassette Lo-Vol pump, 1 piece of Tubing, 0-5 lpm rotameter, Calibration Probe, Bi- Air Cassette, Three-hole Insert, Stopwatch, Sample Bag, Field Sheet, Jeweler s Screwdriver, Marking Pen, Lo-Vol pump at 0.5 lpm for 15 minutes to 4 hours 01 Attach a Bi-Air cassette to the pump using a short piece of tubing & remove slotted cap 02 Label = Project Number and Sample Number (A-01) 03 Attach the calibration probe to the rotameter, place probe on cassette cowl 04 Calibrate the air flow rate to about 0.5 lpm 05 Remove probe and rotameter, put the 3-hole insert into the cowl (no slotted cap) 06 Attach the cassette in the breathing zone of the subject REQUEST FOR ANALYSIS: Sample Type = Air; Sample Media = Bi-Air; Quantity = Sample Volume per trace; Units = L [liters]; Analysis: Trace A = Fungal Spores; Trace B = Fungi, (MEA & DG-18)

4 Wall Cavity: Total Spores and/or Culturable Fungi Using the Bi-Air Cassette Lo-Vol pump, Tubing, 0-5 lpm rotameter, Bi-Air Cassette, Wall probe, Stopwatch, Jeweler s Screwdriver, Field Sheet, Portable Drill, 5/16" Spade Bit, Caulking, (White) Rubber Mallet, Marking Pen Pumps = Lo-Vol pump or Hi-Vol pump Sample time = 2-3 minutes [2 typical]; Flow rate = 1-2 liters per minute Cassette = Bi-Air cassette with wall probe 01 Attach a Bi-Air cassette to the pump using a length of tubing & remove cap 02 Attach a 0-5 lpm rotameter to the front of the cassette using a calibration probe 03 Adjust the flow rate on pump to 1-2 lpm 04 Using a 5/16" spade bit, drill a hole through the wall covering (About 9" up from floor; or 9" down from ceiling; or thru the toe kick of a base cabinet) [CAUTION, DO NOT DRILL INTO PIPES OR CONDUITS] 05 Use the bit to push aside the fiberglass batt insulation inside the wall cavity 06 Attach a wall probe to the Cassette, and insert the probe into the hole as far as it will go, sealing the hole with the flared base of the wall probe, then tap on the wall surrounding the hole (about 5-6 times) [palm of the hand or rubber mallet] CAUTION, DO NOT USE A BLACK MALLET; OR, ENCLOSE IT IN A PLASTIC BAG - IT WILL MARK THE WALL] 08 Collect a sample for the first minute using a stopwatch, then tap on the wall again while collecting the second 1-minute of sample 09 Place the sealed Cassette and used Probe into a plastic bag, and seal the hole in the wall using the Caulk REQUEST FOR ANALYSIS: Sample Type - Air; Sample Media - Bi-Air; Quantity - Sample Volume; Units - (L) liters; Analysis: Trace A - Total Fungal Spores, Trace B - Fungi, MEA & DG-18, Comments - Dilution Plating COMMENTS: Dry media; do not refrigerate. Put cassettes, or Trace A from the cassettes, in a labeled plastic bag, and place in a shipping carton with the completed Request for Analysis. ARCHIVING SAMPLES: 01 Open the cassette 02 Using tweezers, place the filter on a glass slide, and cut the filter in half 03 Place each filter half sample-side down on a glass slide, cover with a support pad, and secure with clear tape 04 Label the slides, shipping one set for analysis and arching the second set

5 Carpet Dust: Culturable Fungi or Quantitative Polymerase Chain Reaciton Hi-Vol pump, Tubing, 0-20 lpm rotameter, 25 mm Sample Cassette, Mechanical Counter, Field Sheet, Marking Pen, Plastic Bag Method 1: Culturing using a 25 mm open-face cassette USE: Carpets & soft-surface furniture; for quantitative comparisons Airflow rate = 10 liters per minute for 25 mm open-face (black) cassette Spots per sample = 20 Sample time per spot = 5 seconds 01 Attach a closed-face cassette to the pump using a length of tubing 02 Attach a 0-30 lpm rotameter to the front of the cassette using plastic tubing 03 Adjust the flow rate to 10 lpm by adjusting the needle valve on the pump 04 Collect a 5-second sample from 20 different locations by holding the cassette firmly against the surface of the carpet or fabric at each location (do not move the cassette, press it firmly against a single spot for the 5 seconds) (Estimate the 5-second period by counting) (Keep track of locations sampled using a mechanical counter) 05 Cap the Sample Cassette and place it in a plastic bag 06 Label = Project Number and Sample Number REQUEST FOR ANALYSIS: Sample Type - Dust; Sample Media - Cassette; Quantity - Sample Area [98 cm 2 ]; Units - 100 cm 2 ; Analysis - Fungi, MEA & DG-18 Comments - Vortex and Aliquot COMMENTS: Dry media; do not refrigerate. Put cassettes in a labeled plastic bag, and place in a shipping carton with the completed Request for Analysis. Method 2: Spore counting using a Bi-Air cassette USE: Carpets & soft-surface furniture when a fast turn-around is needed and QPCR is too expensive. Airflow rate = 2.5 liters per minute Spots per sample = 10 Sample time per spot = 5 seconds