NZQA registered unit standard version 3 Page 1 of 6

Similar documents
NZQA registered unit standard version 2 Page 1 of 7. Conduct a conformity assessment of explosion-protected apparatus

NZQA registered unit standard version 3 Page 1 of 7. Plan electrical installations for explosive atmospheres

NZQA registered unit standard version 1 Page 1 of 8. Conduct detailed inspection of electrical installations for explosive atmospheres

NZQA registered unit standard 1178 version 7 Page 1 of 6

IECEx OPERATIONAL DOCUMENT

NZQA registered unit standard version 1 Page 1 of 5. Meet requirements for Approved Filler Test Certificate for refrigerants

NZQA registered unit standard version 2 Page 1 of 5. Press wood veneer into plywood and laminated veneer lumber

NZQA expiring unit standard version 6 Page 1 of 5. Demonstrate knowledge of electrical safety and safe working practices for electrical workers

NZQA registered unit standard 676 version 5 Page 1 of 5

Explosion Protection Technology Pty Ltd

NZQA Expiring unit standard version 7 Page 1 of 8. Demonstrate knowledge of safe working practices in telecommunications.

Explosion Protection Technology Pty Ltd

NZQA registered unit standard version 2 Page 1 of 5

NZQA unit standard version 5 Page 1 of 5. Describe, develop, and maintain basic ventilation systems for an underground coal mine

NZQA unit standard version 3 Page 1 of 8. Manage the mine ventilation system at an extractive site

NZQA registered unit standard version 3 Page 1 of 7. Demonstrate knowledge of bitumen gangbar sprayers and operations

NZQA Expiring unit standard version 2 Page 1 of 5. This unit standard is for people involved with pest control in rural environments.

NZQA registered unit standard version 3 Page 1 of 8. Operate bitumen gangbar sprayer transfer, heating, and blending equipment

NZQA Expiring unit standard 8296 version 5 Page 1 of 5

NZQA registered unit standard version 3 Page 1 of 6

Session #: Selection of Explosion Protected Equipment for Hazardous Locations

1.8 INDUSTRIAL PROCESS WEIGHING IN HAZARDOUS AREAS

NZQA registered unit standard version 1 Page 1 of 5. Demonstrate knowledge of health and safety when welding and thermal cutting

Dangerous Substances and Explosive Atmosphere Regulations 2002 Appendix 2 Detailed assessment & zone classification where DSEAR applies to an area

NZQA unit standard 7145 version 9 Page 1 of 5. Design and maintain effective ventilation systems for an underground coal mine

NZQA unit standard New US 1Non-coal of 7145 version 1 Page 1 of 5

NZQA registered unit standard version 2 Page 1 of 5

EXPLOSIVE ATMOSPHERES - CLASSIFICATION OF HAZARDOUS AREAS (ZONING) AND SELECTION OF EQUIPMENT

NZQA unit standard version 1 Page 1 of 5. Demonstrate knowledge of hazardous substances relevant to Certified Handlers

TABLE OF CONTENTS PART 2 - CONFINED SPACES

NZQA Expiring unit standard version 3 Page 1 of 5. Demonstrate knowledge of the varroa mite and its control in the beekeeping industry

NZQA registered unit standard 1269 version 7 Page 1 of 5. Plan, prepare for, and carry out line shifts in a cable harvesting operation

QUALIFICATION DETAILS

Confined Spaces. This procedure applies to all workers of the Diocese of Maitland Newcastle (DoMN).

SOP. Working in Confined Spaces

Intrinsic safety 101 hazardous locations

ATEX and explosive atmospheres

NZQA unit standard 8916 version 8 Page 1 of 5

A Unified Marking System for Ex Equipment

AIDGC PRESENTATION MARCH 2006 HAZARDOUS AREAS STANDARDS & CLASSIFICATION

NZQF NQ Ref 1542 Version 3 Page 1 of 9. This qualification has been reviewed. The last date to meet the requirements is 31 December 2020.

Occupational Health and Safety Act

PLANT HAZARD REPORT. Plant Description: Element Aspect Plant Hazards and Controls Advice. Circular Saw

AS/NZS 1596:2014. The storage and handling of LP Gas AS/NZS 1596:2014. Australian/New Zealand Standard. Superseding AS/NZS 1596:2008

ONTARIO REGULATION 632/05 CONFINED SPACES

NZQF NQ Ref 1594 Version 2 Page 1 of 8

ontario regulation 629/05 made under the occupational health and safety act

IGO GROUP SAFETY STANDARD 30 - WORKPLACE VENTILATION INDEPENDENCE GROUP NL

This document is meant purely as a documentation tool and the institutions do not assume any liability for its contents

Safe Work Practices / Procedures / Instruction CONFINED SPACE

PSSI 36 General Confined Spaces, Tunnels, Culverts and Similar Spaces

Level 2 Award in Working in Medium Risk Confined Spaces

Procedure: Pressure equipment safety

This standard comprises the following:

Permit-Required Confined Spaces...29CFR

CONTRACTOR WHS HAZARD STANDARD CONFINED SPACE EXTERNAL USE ONLY

URBAN SEARCH AND RESCUE - OPERATIONS Undertake structural collapse rescue as part of an urban search and rescue (USAR) operation

Dangerous Substances & Explosive Atmospheres Regulation 2002 The Basics. Richard Cowen Dip SH, Dip RSA, CMIOSH, MIIRSM, FRSPH, GI Fire E

Australian/New Zealand Standard

National Certificate in Equine (Community Coach) (Level 3)

NZQA unit standard version 1 Page 1 of 6. Describe hazards and apply risk reduction techniques and strategies while driving a bus or coach

Release: 1. UEPOPL002A Licence to operate a reciprocating steam engine

Course outline: 111 WH&S E101A UEENEEE101A - Occupational Health and Safety regulations, codes and practices in the workplace

CONTRACTOR WHS HAZARD STANDARD HAZARDOUS CHEMICALS EXTERNAL USE ONLY

NZQA registered unit standard version 5 Page 1 of 5. Demonstrate knowledge of abandon ship procedures and sea survival techniques

FOOD GRADE MACHINERY GREASE (DISCONTINUED) MATERIAL SAFETY DATA SHEET

Australian/New Zealand Standard

CONTROL OF SUBSTANCES HAZARDOUS TO HEALTH PROCEDURE

Provide initial response at rope rescue incidents

To ensure compliance to WorkSafeBC Regulation Part 9 Confined Space Entry which states:

Scope: This plan applies to all personnel, including contractors, who enter or work in confined spaces, or supervise such activities.

Confined Space Entry Program Guidelines (Human Resources - Health and Safety Department)

PURPOSE To define the minimum requirements for controlling risks associated with persons entering or working in confined spaces.

ANNEX AMENDMENTS TO THE INTERNATIONAL CODE FOR FIRE SAFETY SYSTEMS (FSS CODE) CHAPTER 15 INERT GAS SYSTEMS

CIVIL INFRASTRUCTURE HEALTH, SAFETY, AND ENVIRONMENT Describe protection of health, safety and environment in the civil infrastructure industry

Preventive Maintenance

SWMS No 009 Samark North Qld Pty Ltd ABN : Electrical Contractors License C37121 Page 2 of 4

NZQF NQ Ref 0733 Version 4 Page 1 of 10

Key Technology, Inc. Confined Space Entry Program. July, 2017

SEMMPF201 Complying with Statutory Regulations and Organisational Safety Requirements

Protocol for Confined Space Entry Requirements

Flammable Environments Guideline

CONFINED SPACE PROGRAM

Electrical Equipment and Installations in Hazardous Areas. Univerza v Ljubljani Fakulteta za elektrotehniko

AS/NZS :2013. Training and certification of occupational divers AS/NZS :2013. Part 5: Dive supervisor. Australian/New Zealand Standard

Working safely in an engineering environment

Working in Confined & Enclosed Space Policy

WHITEPAPER: ATEX IN PRACTICE (EXPLOSION PROTECTION)

Demonstrate lead climbing on bolted rock climbs

NAVIGATION AND SEAMANSHIP Control stress, draught and stability of the ship

CABLE ENTRIES IN HAZARDOUS AREAS CORRECT SELECTION, INSTALLATION AND MAINTENANCE

COSHH Hazardous Substances Health & Safety Management Standard Issue 2 (September, 2010)

DK46 - DK800 Supplementary instructions

Safe Work Practices (SWP) SWP (3) CONFINED SPACE ENTRY

Hampstead Hill School Health and Safety Policy: Confined Spaces

LEVEL 2 CERTIFICATE OF COMPETENCE IN THE SAFE USE OF MOWERS ASSESSMENT SCHEDULE

Procedural Requirement for Confined Space Safe Entry

SOUTH AFRICAN QUALIFICATIONS AUTHORITY REGISTERED UNIT STANDARD:

NZQA registered unit standard version 1 Page 1 of 5. Apply knowledge of river rescue skills on Grade III or above whitewater rivers

Standard Reference Document OPERATING STANDARD 3 PERSONAL PROTECTIVE EQUIPMENT (PPE) AND CLOTHING STANDARD OS 3

Transcription:

Page 1 of 6 Title Report on the integrity of explosion-protected electrical apparatus in explosive atmospheres Level 3 Credits 3 Purpose This unit standard covers the explosion-protection aspects of plant and machinery operation and maintenance. It requires the ability to visually identify any damage or deterioration of explosion-protected apparatus, monitor apparatus and plant in relation to changes in the explosion hazard and to follow procedures to limit the risk of an explosion. This unit standard is intended for people who are responsible for plant operation, maintenance, and inspections. People credited with this unit standard are able to: demonstrate knowledge of visible conditions of explosionprotected apparatus that indicate the protection is void, and changes in the nature of the explosion hazard that may render the explosion-protection unsafe; prepare to work in hazardous area; observe and document condition of explosion-protected system area; and take actions to limit the risks of an explosion. Classification Explosive Atmospheres > Electrical Apparatus in Explosive Atmospheres - Operations Available grade Achieved Entry information Recommended skills and knowledge Unit 26739, Demonstrate introductory underpinning knowledge of electrical apparatus in explosive atmospheres and Unit 26740, Demonstrate and apply intermediate underpinning knowledge of electrical apparatus in explosive atmospheres. Explanatory notes 1 This unit standard has been designed for training and assessment on-job or off-job in a simulated environment which includes explosion-protected apparatus and wiring systems similar to those encountered in a real workplace.

Page 2 of 6 2 This unit standard is directly equivalent to Unit 2.2 Report on the integrity of explosion-protected equipment in hazardous areas in the Australian/New Zealand Standard AS/NZS 4761.1:2008 Competencies for working with electrical equipment in hazardous areas (EEHA) Part 1: Competency standards and includes essential skills and knowledge as specified in the relevant clauses. It aligns with Australian Competency Standard UEENEEM080A from the UEE07 Electrotechnology Training Package Version 3.1 (copyright Australian National Training Information Service). 3 This unit standard is intended to be assessed against in conjunction with other work skills related to operation, installation, maintenance, or servicing of plant or machinery in explosive atmospheres at NZQF Level 3 or above. 4 Competence is to be demonstrated in relation to any classified hazardous areas. 5 References AS/NZS 1768:2007, Lightning protection; AS/NZS 3000:2007, Electrical installations (known as the Australian/New Zealand Wiring Rules); AS/NZS 4761.1:2008, Competencies for working with electrical equipment for hazardous areas (EEHA) Part 1 Competency Standards; AS/NZS 4761.2:2008, Competencies for working with electrical equipment for hazardous areas (EEHA) Part 2 Guide to assessing competency; AS/NZS 60079.10.1:2009, Explosive atmospheres Classification of areas Explosive gas atmospheres; AS/NZS 60079.14:2009, Explosive atmospheres Electrical installations design, selection and erection; AS/NZS 60079.17:2009, Explosive atmospheres Electrical installations inspection and maintenance; AS/NZS 60079.29.2.2008, Explosive atmospheres Gas detectors Selection, installation, use and maintenance of detectors for flammable gases and oxygen; AS/NZS 61241.0:2005, Electrical apparatus for use in the presence of combustible dust General requirements; AS/NZS 61241.14:2005, Electrical apparatus for use in the presence of combustible dust Selection and installation; AS/NZS 61241.2.1:2000, Electrical apparatus for use in the presence of combustible dust Test methods Methods for determining the minimum ignition temperature of dust; Electricity Act 1992; Electricity (Safety) Regulations 2010; Hazardous Substances and New Organisms Act 1996; Health and Safety in Employment Act 1992, and associated regulations; New Zealand Electrical Codes of Practice (NZECP), ISSN 0114-0663 (available from the Ministry of Economic Development); Workplace Exposure Standards and Biological Exposure Indices available from the Department of Labour, http://www.osh.govt.nz/order/catalogue/329.shtml, and associated regulations; and all subsequent amendments and replacements.

Page 3 of 6 7 Definitions Appropriate personnel individuals with responsibilities for co-ordination, design, installation, maintenance, production, or servicing activities. This can include: site managers, project managers, engineers and technicians, technical experts, line managers or supervisors, regulatory personnel, team leaders, other personnel designated by an organisation or enterprise. Defects visual damage or corrosion of the explosion-protection aspect of the installation or apparatus. Established procedures formal documented arrangements of an organisation, enterprise or statutory authority in regard to how work is to be done and by whom and may include but are not limited to quality management systems, safety management systems, work clearance systems, work instructions, reporting systems, and arrangements for dealing with emergencies. Explosion-protection techniques techniques applied to the design of electrical apparatus, components, and systems to prevent the electrical energy from becoming an ignition source in the presence of flammable vapours and gases or combustible dusts in explosive atmospheres. See Explosion-protected apparatus. Explosion-protected apparatus electrical apparatus to which specific measures are applied to avoid ignition of a surrounding explosive atmosphere. Such apparatus employs one or more of the following explosion-protection techniques: For gas and vapour atmospheres Ex d flameproof; Ex e increased safety; Ex i intrinsic safety; with levels of protection Ex ia, Ex ib and Ex ic; Ex n non-sparking; For dusts Ex id intrinsic safety (dusts); Ex td enclosed; Others, less common Ex p pressurisation; Ex pd (dust); Ex m encapsulation, with levels of protection Ex ma, Ex mb, Ex mc (gases and vapours), and Ex md (dusts); Ex s special protection; categorised by Zone of application; e.g. Ex s (Zone 0); Ex o oil immersion; Ex q sand filled; Ex v ventilation. The term apparatus includes equipment, as mentioned in many relevant Standards. Explosive atmosphere an atmosphere comprising volatile substances mixed with air under atmospheric conditions in the form of gases, vapours, mist, or dust in which, after ignition has occurred, combustion spreads to the entire unburned mixture. Hazardous area area in which an explosive atmosphere is present, or may be expected to be present, in quantities such as to require special precautions for the construction, installation, and use of apparatus. Integrity of explosion-protected apparatus the condition of being unified, complete or sound in construction of the apparatus design and use that ensures explosionprotection, for example, the structural integrity of the apparatus.

Page 4 of 6 Visual inspection inspection which identifies, without the use of access apparatus or tools, those defects, such as missing bolts, which will be apparent to the eye. Verification dossier a set of documents showing the complete compliance history of electrical apparatus and installations within hazardous areas, as defined in Standards. Wiring system permitted wiring and accessories for power, measurement, control or communications purposes. 8 a Assessment is to take account of variations between the industry sectors and enterprises. For example, apparatus used in underground coal mining will be different in some respects from that used in a petrochemical plant. b Occupational Safety and Health (OSH) policies and procedures may include but are not limited to work permits and clearances, hazard monitoring, evacuation procedures, plant and electrical isolation. c The application of contingency management skills must be demonstrated for all outcomes and evidence requirements. d Established maintenance procedures must be followed. e All activities and evidence presented for all outcomes and evidence requirements in this unit standard must be in accordance with safe working principles and practices, legislation, policies, procedures, ethical codes and Standards, safe and sound practice, and industry practice; and, where appropriate, manufacturers instructions, specifications, and data sheets. Outcomes and evidence requirements Outcome 1 Demonstrate knowledge of visible conditions of explosion-protected apparatus that indicate the protection is void, and changes in the nature of the explosion hazard that may render the explosion-protection unsafe. 1.1 Visible defects that can be expected in explosion-protected apparatus and wiring are described. 1.2 Conditions that may indicate a change in a given explosion hazard are identified. 1.3 Procedures to be followed in the event of a change in the explosion hazard are explained. Outcome 2 Prepare to work in hazardous area. 2.1 OSH procedures to be followed before entering explosive atmospheres environment and while conducting visual inspection are described.

Page 5 of 6 2.2 Nature of the explosion hazard(s) in the area and risks are identified, and the status of the explosion hazard is ascertained through established procedures. 2.3 Operation and condition of plant and machinery, with regard to explosionprotection, is ascertained through established procedures. 2.4 Established procedures for use of the plant and machinery, with regard to explosion-protection techniques used in the area, are followed. identification of visual damage or deterioration of explosiveprotected apparatus, plant, and machinery operation, examination of apparatus certificate to determine any special installation requirements. Outcome 3 Observe and document condition of explosion-protected system area. 3.1 Performance of plant and machinery is monitored to identify faults that may affect the integrity of the explosion-protected apparatus and wiring system. 3.2 Observations of explosion-protected apparatus and wiring are made during normal operations and visual non-conformances that may affect the integrity of the explosion-protection technique are identified. observation includes integrity of earthing systems, integrity of installation to apparatus certificate. 3.3 Explosion hazard monitoring apparatus is observed and any dangerous state of the hazard is identified. 3.4 Variations outside normal operating conditions are reported to appropriate personnel where relevant and documented in accordance with established procedures. reporting includes but is not limited to appropriate personnel, verification dossier. 3.5 Purpose of reporting defects in explosion-protected apparatus and wiring are described. the purpose of a verification dossier, methods of reporting defects in explosion-protected apparatus and wiring. Outcome 4 Take actions to limit the risk of an explosion. actions may include but are not limited to established procedures for reporting and rectifying defects, shutting down plant or machinery under emergency

Page 6 of 6 conditions, plant and electrical isolation procedures, evacuating a hazardous area, reporting defects and conditions of plant and machinery, monitoring the hazardous area for presence of an explosive atmosphere, meeting OSH obligations; defects may include visual damage and corrosion of apparatus and wiring, loose fasteners, missing fasteners. 4.1 Established procedures are followed in the event of a potential or immediate hazardous condition arising from any non-conformance identified in apparatus and/or wiring, or changes in the explosion hazard to a dangerous state. Planned review date 31 December 2016 Status information and last date for assessment for superseded versions Process Version Date Last Date for Assessment Registration 1 29 August 2000 30 June 2012 Revision 2 3 April 2001 30 June 2012 Review 3 20 May 2011 N/A Consent and Moderation Requirements (CMR) reference 0003 This CMR can be accessed at http://www.nzqa.govt.nz/framework/search/index.do. Please note Providers must be granted consent to assess against standards (accredited) by NZQA, before they can report credits from assessment against unit standards or deliver courses of study leading to that assessment. Industry Training Organisations must be granted consent to assess against standards by NZQA before they can register credits from assessment against unit standards. Providers and Industry Training Organisations, which have been granted consent and which are assessing against unit standards must engage with the moderation system that applies to those standards. Requirements for consent to assess and an outline of the moderation system that applies to this standard are outlined in the Consent and Moderation Requirements (CMRs). The CMR also includes useful information about special requirements for organisations wishing to develop education and training programmes, such as minimum qualifications for tutors and assessors, and special resource requirements. Comments on this unit standard Please contact the (ETITO) reviewcomments@etito.co.nz if you wish to suggest changes to the content of this unit standard.