Geotech 1.66 Reclaimer Installation and Operation Manual

Similar documents
Geotech 3.5 Reclaimer Installation and Operation Manual

Geotech 1.66 Reclaimer

Geotech 1.66 Auto-Reclaimer Installation and Operation

Geotech 1.66 Auto-Reclaimer

Geotech Portable Bladder Pumps Installation and Operation Manual

Geotech 3.5 Auto-Reclaimer

A C Sipper. Installation and Operation Manual. Rev Part #

Marschalk Model # 94000

Geotech Bladder Pumps Installation and Operation Manuals

Multi-Probe Sampling System User Guide & Manual

AR4 4 Auto-Reclaimer. Installation and Operation Manual. Rev 10/9/2017 Part #

Geotech Bladder Pumps

Geotech Portable Bladder Pumps

ETL Water Level Meter

ET Water Level Meter. Installation and Operation Manual. Rev 8/31/12 Part #

BP Controller 300 PSI

Installation and Operating Instructions

MANUAL: IN-LINE PIVOT GAUGE IN-LINE GAUGE

Submersible Pressure Transducer

AIR-OPERATED DOUBLE DIAPHRAGM PUMP USER S MANUAL

AutoPump Catalog. Complete Systems. Featuring the AP4 + Series and the new low - maintenance AP4 Ultra

Sample Pro Portable MicroPurge Pump. User's Guide P/N REV The World Leader in Air Powered Pumps

4-in-1 Professional Inflator Kit

accidents which arise due to non-observance of these instructions and the safety information herein. SPECIFICATIONS

Pressure Injection Cell Operator s Manual

GETZ EQUIPMENT INNOVATORS RECOVERY SYSTEM CLEAN AGENT FE-36 / HALOTRON 1 PART NO. 4G59751 OPERATIONS MANUAL

PANACEA P125 USER MANUAL

accidents which arise due to non-observance of these instructions and the safety information herein. SPECIFICATIONS

Gemini Owner s Manual

TOP VALVE. Pat. #5,857,486 & 5,944,050. Mid-Range Pressure PSIG Back Pressure and Pressure Relief Valves. Instruction Manual

R E D I C O N T R O L S

MANUAL: Jumbo Siamese and Jumbo Wye

INTRODUCTION BILL OF MATERIALS SPECIFICATIONS & TOOLS PROCEDURES OPERATION OF SEATPOST GIANT LIMITED WARRANTY

CS150 CAP STAPLER OWNER S MANUAL

AIR INLINE METAL SHEAR

FloWash. Industrial Filter Cart

PANACEA P100 LOW PRESSURE USER MANUAL

DISASSEMBLING & REASSEMBLING CARTRIDGE INSTALLING SEATPOST ON BIKE

AWG Fittings LLC. Pressure Relief Valve Up to 250 PSI. Product Number Read this instruction manual before use.

Model Series 62 Constant Differential Relay

PANACEA P200 STAINLESS STEEL USER MANUAL

CastCreations PRODUCT DESCRIPTION. Redwood Stump Fire Pit Item #: C1002. CastCreations Ph: Aurora, Utah

100C Air Compressor Kit

INDUSTRIAL VALVES MODELS: C62-A; C62-D. INSTRUCTION MANUAL Installation Operation Parts Service DIAPHRAGM BYPASS PRESSURE REGULATING VALVES

AIR HYDRAULIC RIVETER

Model PSI Compressor with 3-Gallon Air Tank 12VDC

Vessel Installation and Operating Manual

Cocoa Patio Pond with Lit Spillway

ATD LB PRESSURE BLASTER INSTRUCTION MANUAL

Air Operated Hydraulic Pumping Systems to 50,000 psi

WATER HEATER THERMAL EXPANSION TANKS Owner s Manual. Safety Instructions Installation Maintenance Warranty. Models: 2-5 Gallon Capacity

TITAN FLOW CONTROL, INC.

INSTRUCTION MANUAL MST AFTERCOOLER SYSTEM MODEL

SERVICE MANUAL MODEL BA050BMST BREATHING AIR PANEL

Installation and Operating Manual

8-GAL PNEUMATIC OIL DISPENSER

Install Manual October 2011

SPECIFICATIONS TABLE Maximum Air Pressure 115 PSI Air Tank Capacity 20 Gallons

Paintball Marker. User s Manual. 530 South Springbrook Road Newberg, OR 97132

200 PSI COMPRESSORS - MODEL NUMBERS

PRO SINK -R 1 and 2. Dilution system CONTENTS

LUDLUM MODEL 239-1F FLOOR MONITOR. Revised December 2010

APCO ASU-SCAV & ASU-CAV SINGLE BODY COMBINATION AIR VALVES

CSA Sample Draw Aspirator Adapter Operator s Manual

Installation Instructions JATCO Environmental Protection Tank Model J-5000CX

420C AIR COMPRESSOR KIT PART NO C AIR COMPRESSOR KIT PART NO

IMPORTANT SAFETY INSTRUCTIONS

DB 61 Dolphin TMV3 Integrated Thermostatic Mixing Valve

GETZ EQUIPMENT INNOVATORS PART No. 4G59678 CARBON DIOXIDE MINI PUMP FOR EXTINGUISHER SERVICE (Revised )

250C-IG COMPRESSOR KIT 12V PART NO C-IG COMPRESSOR KIT 24V PART NO

Model Series 63DL Differential Type Flow Controller

3" UC Ultra-Chuck Durable Lightweight Air Inflated Bladder Chuck Operation/Repair Manual. (76.2 mm) DOUBLE E COMPANY, INC.

ULSE. Installation and Operation Manual PNEUMATIC PUMPING SYSTEMS. Patent No

FLANGED TWO-PIECE BALL VALVES

Model ASSEMBLY and OPERATING INSTRUCTIONS


250C-IG COMPRESSOR KIT 12V PART NO C-IG COMPRESSOR KIT 24V PART NO

4 and 8 Station PDS Control Installation & Operators Manual

MODEL NUMBER: PSI AIR SOURCE KIT 200 PSI Compressor on 2.0 Gallon 200 PSI Air Tank

Model Portable Eyewash

200 PSI FAST-FILL AIR SOURCE KIT

200 PSI HIGH-FLOW AIR SOURCE KIT

Installation Instructions JATCO Environmental Protection Tank Model J-7000

444C DUAL PERFORMANCE VALUE PACK

MODEL NUMBER: M20005 AIR SOURCE KIT. 30% Duty Compressor on. 2.0 Gallon Air Tank SAVE THIS MANUAL FOR FUTURE REFERENCE

TOP VALVE. Pat. #5,857,486 & 5,944,050. High Temperature: max. 300 F (149 C) Back Pressure And Pressure Relief Valves. Instruction Manual

ROUGHNECK II Pumpless Drain

Geocontrol PRO Installation and Operation Manual

ISB SERIES INTERNAL SHOT BLASTING MACHINES INSTRUCTION MANUAL MANUAL NUMBER

400C & 450C DUAL PERFORMANCE VALUE PACKS

Model B-1 Pipe Line Strainer 3, 4, 6 & 8 Inch (DN80, DN100, DN150 & DN200) 175 psi (12,1 bar) General Description. Technical Data

J Air and Water Kit Instructions Part# 02584

DBML-60/80 Squeeze Tool

HYDRAULIC WINCH FOR AUGERS UP TO WR10 X 71 / W130 X 41 ASSEMBLY & OPERATION MANUAL

EQUIPMENT OPERATION MANUAL. Loctite Dispense Valve Manual

Stainless Steel 142 mm Filter Holder YY

User Operation Manual and Safety Instructions

FLUSHMATE III FLUSHMATE FLUSHOMETER - TANK SYSTEM. Owner s Service Manual. 503 Series. 503 Series

2.5 & 5.0 GALLON PRESSURE TANKS

RAM 4021 Operation Manual

Transcription:

Geotech 1.66 Reclaimer Installation and Operation Manual Rev. 2 6/23/03 Part # 26600137

TABLE OF CONTENTS Chapter 1: System Description...p. 0 Function and Theory...p. 0 System Components...p. 0 Chapter 2: System Installation...p. 0 Chapter 3: System Operation...p. 0 Chapter 4: System Maintenance...p. 0 Chapter 5: System Troubleshooting...p. 1 Chapter 6: System Specifications...p. 1 Chapter 7: System Schematic...p. 1 Chapter 8: Replacement Parts List...p. 2 Warranty and Repair...p. 2

DOCUMENTATION CONVENTIONS This manual uses the following conventions to present information: WARNING An exclamation point icon indicates a WARNING of a situation or condition that could lead to personal injury or death. You should not proceed until you read and thoroughly understand the WARNING message. CAUTION A raised hand icon indicates CAUTION information that relates to a situation or condition that could lead to equipment malfunction or damage. You should not proceed until you read and thoroughly understand the CAUTION message. A note icon indicates NOTE information. Notes provide additional or supplementary information about an activity or concept. NOTE

Chapter 1: System Description Function and Theory The Geotech Reclaimer configured as a Top fill, Bottom fill, or Top & Bottom fi is a fixed intake, positive air displacement pump designed for total fluids, hydrocarbon, leachate, and condensate recovery. The Geotech Reclaimer is designed to withstand the most aggressive down well environments including highly corrosive fluids without material breakdown or failure. The Geotech Reclaimer will recover fluids from depths to 690. See operation section. Flow rates of up to 3 GPM are possible. See specifications section. The Geotech 1.66 Reclaimer will operate in wells 2 in diameter or larger vertical wells.

System Components Screened Intake (For Top and Dual fill models) Air Inlet Product Discharge Pump Housing Check Ball (For Bottom and /Dual fill models) Lower Cap (For Top fill model) Figure 1 Bottom Intake (For Dual and Bottom fill models)

Chapter 2: System Installation Attach product discharge & air supply hoses to the proper barbed fittings on the pump. If pump configuration was not assembled as a complete system, please use the following steps: Attach air supply hose to Geotech pneumatic controller. Ensure all hoses are installed securely and completely. Attach safety cable to support loop using crimps or cable clamps. The Reclaimer can now be lowered into the recovery well. For optimum efficiency, the Reclaimer must be positioned in the well according to intake configuration. See figures 2 and 3. Figure 2 1.66 Reclaimer Bottom Fill Figure 3 1.66 Reclaimer Top Fill

Chapter 3: System Operation Compressed air is utilized in this system. Typically.5 to 1.0 cubic foot of air is necessary per gallon of liquid being pumped. For pressure requirements use.5 psi per foot of lift plus ten. Example 30 of head would need a minimum of 25 psi. TOP FILL The Top Fill Reclaimer is placed in a recovery well with the top inlet submerged well below static groundwater. Combined with the Geotech Pneumatic Controller, the Reclaimer cyclically fills and empties. BOTTOM FILL Well recharge rate and time sequence settings on the Geotech Pneumatic Controller will affect the maintainable fluid level. See specifications section for max. flow rate. The Bottom Fill Reclaimer is placed in a recovery well with the bottom intake submerged well below static groundwater. Combined with Geotech s Pneumatic Controller, the Reclaimer cyclically fills and empties. Well recharge rate and time sequence settings on the Geotech Pneumatic Controller will affect the maintainable fluid level, see figure 4.

Figure 4 1.66 Reclaimer

Chapter 4: System Maintenance Dependant upon the fluids being pumped, the Geotech Reclaimer has been designed to be virtually maintenance free. In the event of clogging of the pum housing or trapped particulate in the check ball seats, use high pressure washer with soapy or clean water to dislodge any matter. All wetted materials are 300 series stainless steel and should provide many years of maintenance free service. See figure 5.

Top Fill Bottom Fill Figure 5

Chapter 5: System Troubleshooting PROBLEM: Pump does not discharge fluid to the surface. SOLUTIONS: 1. Ensure air pressure is adequate enough. (See specifications section, min operating pressure example:.43 psi per ft. of static head pressure) 2. Inlet screen is clogged Clean screen 3. Inlet pipe plug is clogged Clear, Clean plug 4. Air exhaust vent hose is clogged Clear vent hose 5. Hoses are kinked or cut Replace hoses

Chapter 6: System Specifications 1.66 Reclaimer Outside Diameter 1.66 Length 49 Weight 5 lbs. Max. Rate Depth 690 Min. Well ID 2 Operating Pressure Range 10-300 psi Volume/Cycle.19 gal Max. Flowrate 2.95 gpm Fittings Stainless Steel Fluid Discharge ½ - ¾ Air Supply ¼ -? Min. Operating Pressure 10 psi

3.00 2.50 2.00 1.50 1.00 0.50 0.00 1.66 Reclaimer Top Fill Recovery Rate 300 psi 100 psi 200 psi 0 100 200 300 400 500 600 700 Pump depth, ft GPM

25.00 20.00 15.00 10.00 5.00 0.00 1.66 Reclaimer Top Fill Air Consumption 300 psi 200 psi 100 psi 0 100 200 300 400 500 600 700 800 Pump depth, ft SCF/gal

3.00 2.50 2.00 1.50 1.00 0.50 0.00 1.66 Reclaimer Bottom Fill Recovery Rate 300 psi 100 psi 200 psi 0 100 200 300 400 500 600 700 Pump depth, ft GPM

25.00 20.00 15.00 10.00 5.00 0.00 1.66 Reclaimer, Bottom Fill Air Consumption 300 psi 200 psi 100 psi 0 100 200 300 400 500 600 700 800 Pump depth, ft SCF/gal

3.00 2.50 2.00 1.50 1.00 0.50 0.00 1.66 Reclaimer Dual Fill Recovery Rate 300 psi 100 psi 200 psi 0 100 200 300 400 500 600 700 Pump depth, ft GPM

25.00 20.00 15.00 10.00 5.00 0.00 1.66 Reclaimer Dual Fill Air Consumption 300 psi 200 psi 100 psi 0 100 200 300 400 500 600 700 800 Pump depth, ft SCF/gal

Exhaust times for different air line ID and lengths, 20' submergence 70.0 60.0 50.0 40.0 30.0 20.0 10.0 0.0 50 100 150 200 250 300 350 400 450 500 Air line length, feet.5" ID.375" ID.25" ID.17" ID Exhaust time, sec These graphs are specific to the Geotech PRS Controller.

Exhaust times for different air line ID and lengths, 20' submergence 250.0 200.0 150.0 100.0 50.0 0.0 50 100 150 200 250 300 350 400 450 500 Air line length, feet 1" ID.75" ID.5" ID Exhaust time, sec

Chapter 7: System Schematic Top Fill Bottom Fill Dual Fill

Chapter 8: Replacement Parts List Part Number Part Description 26600050 Cap, Upper 26600059 Pipe, Intake, 43.75 LG 17200330 Union 56600024 Assy, Intake Screen 26600051 Tube, Housing, 48 26600060 Cap, Lower, Plug 26600055 Pin, Hanger 26600052 Pipe, Discharge, 44.5 LG 56600023 Assy, Valve, Check, Inline 16600117 Hose Barb 17500104 O-Ring 77051004 Safety Cable 17200098 Crimp, Oval Sleeve 17200043 Nut, Hex 16600145 Hose Barb

Notes

Notes

The Warranty For a period of one (1) year from date of first sale, product is warranted to be free from defects in materials and workmanship. Geotech agrees to repair or replace, at Geotech s option, the portion proving defective, or at our option to refund the purchase price thereof. Geotech will have no warranty obligation if the product is subjected to abnormal operating conditions, accident, abuse, misuse, unauthorized modification, alteration, repair, or replacement of wear parts. User assumes all other risk, if any, including the risk of injury, loss, or damage, direct or consequential, arising out of the use, misuse, or inability to use this product. User agrees to use, maintain and install product in accordance with recommendations and instructions. User is responsible for transportation charges connected to the repair or replacement of product under this warranty. Equipment Return Policy A Return Material Authorization number (RMA #) is required prior to return of any equipment to our facilities, please call our 800 number for appropriate location. An RMA # will be issued upon receipt of your reques to return equipment, which should include reasons for the return. Your return shipment to us must have this RMA # clearly marked on the outside of the package. Proof of date of purchase is required for processing of all warranty requests. This policy applies to both equipment sales and repair orders. FOR A RETURN MATERIAL AUTHORIZATION, PLEASE CALL OUR SERVICE DEPARTMENT AT 1-800-833-7958 OR 1-800-275-5325. Model Number: Serial Number: Date: Equipment Decontamination Prior to return, all equipment must be thoroughly cleaned and decontaminated. Please make note on RMA form, the use of equipment, contaminants equipment was exposed to, and decontamination solutions/methods used. Geotech reserves the right to refuse any equipment not properly decontaminated. Geotech may also choose to decontaminate equipment for a fee, which will be applied to the repair order invoice.

Geotech Environmental Equipment, Inc 8035 East 40 th Avenue Denver, Colorado 80207 (303) 320-4764? (800) 833-7958? FAX (303) 322-7242