Technical Data. Dimensions

Similar documents
Inductive slot sensor

Technical Data. Dimensions

Technical Data. Dimensions

Technical Data. Dimensions

Technical Data. Dimensions

Technical Data. Dimensions

Technical Data. General specifications Switching element function Rated operating distance s n 5 mm

Technical Data. General specifications Switching element function Rated operating distance s n 1.5 mm

Technical Data. General specifications Switching element function Rated operating distance s n 2 mm

Technical Data. General specifications. Rated operating distance s n 5 mm

Technical Data. General specifications. Rated operating distance s n 2 mm

Technical Data. Dimensions

Technical Data. Dimensions

Technical Data. General specifications Switching element function DC Dual NC Rated operating distance s n 3 mm. Short-circuit protection

Dimensions. Technical Data General specifications Switching element function Rated operating distance s n 10 mm

Dimensions. Technical Data General specifications Switching element function DC Dual NC Rated operating distance s n 3 mm

Dimensions. Technical Data General specifications Switching element function Rated operating distance s n 5 mm

Dimensions. Technical Data General specifications Switching element function DC Dual NC Rated operating distance s n 3 mm

Dimensions. Technical Data General specifications Switching element function DC Dual NC Rated operating distance s n 3 mm

Dimensions. Technical Data General specifications Switching element function DC Dual NC Rated operating distance s n 3 mm

Technical Data. General specifications Switching element function DC Dual NC Rated operating distance s n 3 mm. Short-circuit protection

DK46 - DK800 Supplementary instructions

VG5 Supplementary instructions

IA CERTIFICATE (Revision 3 Revised for Annual Review) Hazel Grove Stockport Cheshire SK14 6NG United Kingdom

Certificate of Compliance

VS18/26 with PROFINET and EtherNet/IP Interface. ATEX Installation Instructions

Pressure switch, Differential pressure switch and Thermostat RT-E

LMP 307. Stainless Steel Probe. Stainless Steel Sensor. accuracy according to IEC 60770: standard: 0.35 % FSO option: 0.25 % / 0.

OSAT Series. Intrinsically Safe Infrared Temperature Sensor Operator's Guide

RTD temperature probes

Electropneumatic Positioner and Pneumatic Positioner Type 3760 JIS

CERTIFICATE OF COMPLIANCE

Electropneumatic Positioner Type 4763 Pneumatic Positioner Type 4765

Operating instructions Safety Rope Emergency Stop Switches ZB0052 / ZB0053 ZB0072 / ZB0073

Pressure control, differental pressure control and thermostat Type RT

Safety Instructions Liquiphant FailSafe FTL80, FTL81, FTL85

Electropneumatic Positioner and Pneumatic Positioner Type 3760 JIS

Pressure switch with bourdon tube

II 2G EEx ia IIC T6. Ignition protection class

OPTIBAR P 1010 C Technical Datasheet

DMK 458. Pressure Transmitter for Marine and Offshore. Ceramic Sensor. accuracy according to IEC 60770: standard: 0.25 % FSO option: 0.

Level transmitter LT 100

ATM.1ST/Ex - High Precision Transmitter

Miniature flowmeters DK 46, DKR 46 DK 47, DK 48, DK 800

Operating Instructions

Single and double acting, magnetic, self-centering Bores: ø 16, 20, 25, 32, 40 mm

ATM.ECO/IS - Analog Transmitter with Temperature compensation

1 Overview. Pressure Measurement Transmitters for basic requirements. 1/16 Siemens FI SITRANS P220 for gauge pressure

Level sensing relative and absolute pressure transmitter type 712

Pressure Switches Application Guideline

Perpetua Power Puck Solutions

x act i Precision- Pressure Transmitter for Food Industry, Pharmacy and Biotechnology Stainless Steel Sensor

Supplementary Installation and Operating Instructions. Variable Area Flow Meters SGK-1 Ex SGK-2 Ex SGK-3 Ex. Category: II 2G Ex IIC II 3G Ex IIC

L (up to 25 m) Electronic part. working temp.: Ñ IP 66 / IP67. Mounting bracket ÐÑ. Sensor type. working temp.:

Level switches Series LD Vibrating fork level switch for liquids and solids

High-performance submersible pressure transmitter For level measurement Model LH-20

Monitoring device NTS 30

Technical Datasheet. D Series SMART Pressure Transmitter Model: DPC D-Series. Key Features. Series Overview. Product applications

BA307C & BA308C Intrinsically safe loop-powered 3½ digit panel mounting indicators issue 9

1 Overview. Pressure Measurement Single-range transmitters for general applications. 1/22 Siemens FI US Edition

High-performance submersible pressure transmitter For level measurement Model LH-20

IA CERTIFICATE (Annual review required by MASC covered by an additional letter) (Revision 2- Review & Review)

x act i Precision Pressure Transmitter for Food Industry, Pharmacy and Biotechnology Stainless Steel Sensor accuracy according to IEC 60770: 0.

High-performance submersible pressure transmitter For level measurement in hazardous areas Model LH-20

SITRANS P measuring instruments for pressure

Hidrostatic Level DATASHEET

Manual Power relay SR853

Level switches Series LD Vibrating fork level switch for liquids and solids

Pressure Measurement Single-range transmitters for general applications

Type N-10, N-11 Hazardous Area Non-incendive Transmitters

Orifice Plate Flow Meter

Rosemount 2120 Full-featured Vibrating Fork Liquid Level Switch. Quick Start Guide , Rev BA August 2012

LTB013EN. Operating Instruction Trimod Besta Level Switch types XA 5, XB 5 for use in potentially explosive atmospheres acc.

Mechanical pressure switches

MJK Expert 700 / 800 / 900 / 7070 / 7060 MJK Expert 1400 / 3400

1.8 INDUSTRIAL PROCESS WEIGHING IN HAZARDOUS AREAS

EX-RECESSED CEILING LIGHT FITTINGS

1 Overview. Pressure Measurement Single-range transmitters for general applications. 1/22 Siemens FI

1 Overview. Pressure Measurement Single-range transmitters for general applications. 1/16 Siemens FI US Edition

High-performance submersible pressure transmitter For level measurement Model LH-20

Pressure Measurement Single-range transmitters for general applications

Operating Instructions

(Certification N:o VTT 08 ATEX 066 or IECEx VTT )

Relative pressure transmitter type 520

Two-Wire In Situ Oxygen Analyzer (550 to 1400 C)

Compact differential pressure switch Flameproof enclosure Ex d Models DE, DEC

Liquid level instruments BM 24 /BM 51

Polymer Electric. Product information. Normally Closed Safety Edges SL/NC II. GmbH & Co. KG. Polymer Electric

Operating Instructions

4/2 way Pneumatic Solenoid Valve

FULL STAINLESS STEEL EXPLOSION-PROOF SOLUTIONS OIL & GAS I OFFSHORE AND ONSHORE

I/P Transducer Positioner Module

CERTIFICATE OF COMPLIANCE

UHrasonic Sensor VEGASON60 type series SN6*.CI**H***

Bourdon tube pressure gauge for diaphragm seals

Temperature gauge Installation Guide

Two-Wire In Situ Oxygen Analyzer (550 to 1400 C)

GA24 Technical Datasheet

VA40 - VA45 Technical Datasheet

ATM/Ex - Intrinsically Safe Analog Pressure Transmitter - ATEX / IECEx Certified

Transcription:

0102 Model Number Features 6 mm flush Usable up to SIL 3 acc. to IEC 61508 Application Danger! In safety-related applications the sensor must be operated with a qualified fail safe interface from Pepperl+Fuchs, such as KFD2-SH-EX1. Consider the "exida Functional Safety Assessment" document which is available on www.pepperl-fuchs.com as an integral part of this product s documentation. Technical Data specifications Switching element function NAMUR, NC Rated operating distance s n 6 mm Installation flush Output polarity Safety Function Assured operating distance s a 0... 4.86 mm Reduction factor r Al 0.4 Reduction factor r Cu 0.3 Reduction factor r 304 0.85 Nominal ratings Nominal voltage U o 8 V DC Operating voltage U B 5... 25 V Switching frequency f 0... 2000 Hz Suitable for 2:1 technology yes, with reverse polarity protection diode Current consumption Measuring plate not detected 3 ma Measuring plate detected 1 ma Functional safety related parameters MTTF d 9191 a Mission Time (T M ) 20 a Diagnostic Coverage (DC) 0 % Ambient conditions Ambient temperature -40... 100 C (-40... 212 F) Mechanical specifications Connection type cable silicone, 2 m Core cross-section 0.75 mm 2 Housing material PBT Sensing face PBT Degree of protection IP68 Cable Bending radius > 10 x cable diameter information Use in the hazardous area see instruction manuals Category 1G; 2G; 1D Compliance with standards and directives Standard conformity NAMUR EN 60947-5-6:2000 IEC 60947-5-6:1999 Standards EN 60947-5-2:2007 IEC 60947-5-2:2007 Approvals and certificates FM approval Control drawing 116-0165 UL approval culus Listed, Purpose CSA approval ccsaus Listed, Purpose CCC approval CCC approval / marking not required for products rated 36 V Dimensions Ø 22 35 1

Electrical Connection BN L+ BU L- 2

ATEX 1G Device category 1G for use in hazardous areas with gas, vapour and mist II 1G Ex ia IIC T6 T1 Ga Ignition protection "Intrinsic safety" Use is restricted to the following stated conditions NJ 6-22-SN Effective internal inductance L i 150 µh ; a cable length of 10 m is considered. observed. The special conditions must be adhered to! Directive 94/9/EC and therefore the EC-type-examination certificates generally apply only to the use of electrical apparatus under atmospheric conditions. Ambient temperature ambient temperature, the temperature class, and the effective internal reactance values can be found on the EC-type examination certificate. Note: Use the temperature table for category 1!!! The 20 % reduction in accordance with EN 1127-1 has already been applied to the temperature table for category 1. related apparatus and according to the proof of intrinsic safety. The associated apparatus must satisfy the requirements of category ia. Because of the risk of ignition, which can occur due to faults and/or transient currents in the equipotential bonding system, galvanic isolation is preferable in the supply and signal circuits. Associated apparatus without electrical isolation can only be used if the corresponding requirements of IEC 60079-14 are satisfied. If the Ex-related marking is printed only on the supplied label, then this must be attached in the immediate vicinity of the sensor. The sticking surface for the label must be clean and free from grease. The attached label must be legible and indelible, including in the event of possible chemical corrosion. Electrostatic charge When used in group IIC non-permissible electrostatic charges should be avoided on the plastic housing parts. Avoid electrostatic charges that can cause electrostatic discharge when installing or operating the device. Information on electrostatic hazards can be found in the technical specification IEC/TS 60079-32-1. 3

ATEX 2G Device category 2G for use in hazardous areas with gas, vapour and mist II 1G Ex ia IIC T6 T1 Ga Ignition protection "Intrinsic safety" Use is restricted to the following stated conditions NJ 6-22-SN-... Effective internal inductance L i 150 µh ; a cable length of 10 m is considered. observed. The special conditions must be adhered to! Directive 94/9/EC and therefore the EC-type-examination certificates generally apply only to the use of electrical apparatus under atmospheric conditions. Maximum permissible ambient temperature T amb ambient temperature, the temperature class, and the effective internal reactance values can be found on the EC-type examination certificate. related apparatus and according to the proof of intrinsic safety. If the Ex-related marking is printed only on the supplied label, then this must be attached in the immediate vicinity of the sensor. The sticking surface for the label must be clean and free from grease. The attached label must be legible and indelible, including in the event of possible chemical corrosion. 4

ATEX 1D Device category 1D for use in hazardous areas with combustible dust II 1D Ex ia IIIC T135 C Da Ignition protection "Intrinsic safety" Use is restricted to the following stated conditions NJ 6-22-SN-... Effective internal inductance L i 150 µh A cable length of 10 m is considered. Permissible ambient temperature range observed. Directive 94/9/EC and therefore the EC-type-examination certificates generally apply only to the use of electrical apparatus under atmospheric conditions. ambient temperature, the surface temperature, and the effective internal reactance values can be found on the EC-type-examination certificate. The maximum permissible ambient temperature of the data sheet must be noted, in addition, the lower of the two values must be maintained. related apparatus and according to the proof of intrinsic safety. If the Ex-related marking is printed only on the supplied label, then this must be attached in the immediate vicinity of the sensor. The sticking surface for the label must be clean and free from grease. The attached label must be legible and indelible, including in the event of possible chemical corrosion. Electrostatic charge Avoid electrostatic charges that can cause electrostatic discharge when installing or operating the device. Information on electrostatic hazards can be found in the technical specification IEC/TS 60079-32-1. Do not attach the nameplate provided in areas where electrostatic charge can build up. 5