May 1, By John Heim,Doug Staples

Similar documents
Extend the time window for the detection of low level anabolic androgenic steroids and their metabolites

Longterm Detection of Anabolic Steroid Metabolites in Urine

WADA Technical Document TD2014EAAS. Endogenous Anabolic Androgenic Steroids Measurement and Reporting

Comparative analysis of mass spectral matching for confident compound identification using the Advanced Electron Ionization source for GC-MS

Simultaneous Determination of a Panel of 22 Steroids in Urine and Serum by SPE and LC-MS/MS

Automated Determination of Dissolved Gases in Water Anne Jurek. Abstract: Discussion:

Trace-Level Analysis of Metanephrines in Plasma by HILIC LC-MS/MS

Sample purification procedure for confirmation of 3 -hydroxy stanozolol by gas chromatography/high resolution mass spectrometry

Gases&Technology. Measurement of Impurities in Helium Using the Dielectric Barrier Discharge Helium Ionization Detector. FEATURE.

Simplified Backflush Using Agilent 6890 GC Post Run Command Application Note

GCMSD-Headspace Analysis SOP

Analysis of Melamine and Cyanuric Acid in Food Matrices by LC-MS/MS

WADA Technical Document TD2016EAAS. Endogenous Anabolic Androgenic Steroids Measurement and Reporting

Jaap de Zeeuw Restek Corporation, Middelburg, The Netherlands. Copyrights: Restek Corporation

METHOD 3C - DETERMINATION OF CARBON DIOXIDE, METHANE, NITROGEN, AND OXYGEN FROM STATIONARY SOURCES

APPLICATION NOTE. Fast Analysis of Coal Mine Gas Using the INFICON 3000 Micro GC ABSTRACT

Rapid and Reliable Detection of Dissolved Gases in Water

Methylprednisolone detection in urine following local and oral administrations

Toxicology Gas Chromatography-Mass Spectrometry (GC-MS)

Using the PreVent System in Time-Saver Mode with the AutoSystem XL Gas Chromatograph and the TurboMass Mass Spectrometer

Development of a Clinical Research Method for the Measurement of Testosterone. Dihydrotestosterone

Automated Determination of Dissolved Gases in Water Anne Jurek

High speed UHPLC-MS/MS determination of multiple steroids in human serum using the Nexera MX system for multiplex analysis

Low-Pressure Retention Time Locking with the 7890A GC. Application. Authors. Abstract. Introduction HPI

(2 pts) Draw the line of best fit through the data and estimate the concentration of Fe in your sample solution.

Now it is. easy to switch. CHS TM Steroid Profiling kit and software. Brochure not for distribution in the USA and Canada

SPECIFIC DETECTION OF ANDROST-4-ENE-3,17-DIONE

Analysis of Benzenesulfonic Acid and P-Toluenesufonic Acid Esters in Genotox Monitoring using UPLC/UV-MS

Technical Procedure for Drug Chemistry Gas Chromatograph/Mass Spectrometry (GC-MS)

Experiment GC : Analysis of BTEX by GC-FID

OMCL Network of the Council of Europe QUALITY ASSURANCE DOCUMENT

WADA Technical Document TD2017NA

Automated Determination of Dissolved Gases in Water By Headspace Calibration of Mixed Gases Anne Jurek

CORESTA RECOMMENDED METHOD Nº 67

Retention Time Locking: Concepts and Applications. Application

extraction of EG and DEG from the matrix. However, the addition of all diluent at once resulted in poor recoveries.

APPLICATION NOTE. GC Integrated Permeation Device

WADA Technical Document TD2010EAAS. Endogenous Anabolic Androgenic Steroids Testing, Reporting and Interpretive Guidance

Quantitative Analysis of Hydrocarbons by Gas Chromatography

The instrument should have a mass range from 2 to 2000 m/z or better Interface

The Application of QuEChERS in the Extraction of Anabolic Steroids in Whole Blood

SOP: Derivatized testosterone_01 Revision: 01 Date Effective: 05/17/15

LINEAR TRANSFORMATION APPLIED TO THE CALIBRATION OF ANALYTES IN VARIOUS MATRICES USING A TOTAL HYDROCARBON (THC) ANALYZER

Analysis of Melamine and Cyanuric Acid in Food Matrices by LC-MS/MS

GC-MS(/MS) investigations on long-term metabolites of 17-methyl steroids

Introduction. Experimental

Laboratory Hardware. Custom Gas Chromatography Solutions WASSON - ECE INSTRUMENTATION. Engineered Solutions, Guaranteed Results.

LCMSMS Solutions For Steroid Analysis

ASTM WK Standard Test Method for Dissolved Gases. Anne Jurek Applications Chemist

Proudly serving laboratories worldwide since 1979 CALL for Refurbished & Certified Lab Equipment Varian 310

WADA Technical Document TD2018MRPL

User guide for operating the Agilent 6420A QqQ mass spectrometer by direct infusion/injection

Determination of Selected ASTM Perfluorinated Compounds (PFCs) Using the Shimadzu LCMS No. LCMS-083. No. SSI-LCMS-083

Optimizing Vial Pressurization Parameters for the Analysis of <USP 467> Residual Solvents Using the 7697A Headspace Sampler

Agilent Dimension Software for ELSD User Manual

WADA Technical Document TD2018EAAS. Endogenous Anabolic Androgenic Steroids Measurement and Reporting

GUIDE TO ULTRA-FAST HPLC. Quick Tips for Converting Conventional Reversed-Phase HPLC Separations to Ultra-Fast Separations

1. INTRODUCTION CH 3 CH3

Extended Application Note

DETERMINATION OF TETRAHYDROTHIOPHENE IN AMBIENT AIR BY GAS CHROMATOGRAPHY WITH A PFPD DETECTOR COUPLED TO A PRECONCENTRATION TECHNOLOGY

During today's webinar we're going to look at the following topics:

Commercial Practice Test Method Internal Vapor Analysis of Hermetic Devices

Evaluation of linear and step gradient performance and retention time precision of the Agilent 1200 Series Rapid Resolution LC

Three Columns Gas Chromatograph Analysis Using Correlation between Component's Molecular Weight and Its Response Factor

Carrier Gases in Capillary GC

CHEMTRACE Fremont Blvd. Fremont, CA 94538, Tel: (510) Fax: (510)

A Column-Flow Independent Configuration for QuickSwap. Application. Authors. Abstract. Introduction

Chemical Analysis for Methyltestosterone

Laboratory Hardware. Custom Gas Chromatography Solutions WASSON - ECE INSTRUMENTATION. Custom solutions for your analytical needs.

RECENT ADVANCES IN DOPING ANALYSIS (2)

High Automation of Thermo Scientific FlashSmart CHNS/O Analyzer using the MultiValve Control (MVC) Module

Gas chromatographic determination of 1,4-dioxane at the

Supporting Information for Micro-Collection of. Gases in a Capillary Tube: Preservation of Spatial

no peaks missing peaks too small peaks increasing retention decreasing retention

MSD 96-Well MULTI-ARRAY and MULTI-SPOT Human Granulocyte Colony Stimulating Factor (hg-csf) Ultrasensitive Assay

Impact of Air Leaks on the Productivity of GC and GC/MS Systems

Weiyi Zheng, Xiaoxia Dong, Evan Rogers, Jimmie C. Oxley, and James L. Smith*

Gas Chromatography. MS Vent Enhancement to the PreVent System to Optimize Operation with the TurboMass, TurboMass Gold, and Clarus 500 GC/MS Systems

Title: Standard Operating Procedure for Measurement of Ethylene (C 2 H 4 ) in Ambient Air by Reduced Gas Detection (RGD)

System Overview. TCD Detector temperature setpoint Regulator

Gas Chromatographic Applications of the Dielectric Barrier Discharge Detector

ISO INTERNATIONAL STANDARD

CHM Gas Chromatography: Our Instrument Charles Taylor (r10)

TRACE LEVEL DETERMINATION OF PER- AND POLYFLUOROALKYL SUBSTANCES (PFASs) IN WATER USING THE AGILENT 6460 LC/MS/MS

Your local gas generation partner. Precision series Modular gas generation solution for GC.

TROUBLESHOOTING. Dwell Volume Revisited. Gradient transfer does not have to be problematic.

TESTOSTERONE AND ESTERS* Latest Revision: June 23, 2005

Hiden QIC Series Gas Analysers Real-time gas analysis systems

The analysis of complex multicomponent

Advancements in Gas Chromatography Analyzers - Keeping up with New Technology. Chuck Runkle Gas Phase Product Specialist ASTS June 2013

Renzo BAGNATI Mario Negri Institute of Pharmacological Research- IRCCS Milano - Italy

M/s. Thermo fisher Scientific

SUPPORTING INFORMATION

Measuring mass flows in hermetically sealed MEMs & MOEMs to ensure device reliability

Gas chromatographic and mass spectrometric analysis of conjugated steroids in urine

Demystifying the Process of Calibrating your Thermal Desorption Gas Chromatography System using Compressed Gas Standards.

Agilent 6890N, Option 652 Oral Fluids Analyzer

Flare Gas Composition Analysis and QA/QC Lessons Learned and Lessons Lost SPECTRUM ENVIRONMENTAL SOLUTIONS, LLC 1

Agilent 7800 ICP-MS. Specifications and Typical Performance. Fast track metals analysis with Solution-Ready ICP-MS

ISO INTERNATIONAL STANDARD

Transcription:

1 of 7 7/11/2014 3:39 PM May 1, 2010 By John Heim,Doug Staples Anabolic steroid screening analysis in urine is complex and labor intensive requiring sensitive instrumentation and optimized chromatographic separations. This research presents the practical application of comprehensive two-dimensional gas chromatography time-of-flight-mass spectrometry (GC GC TOF-MS) for the identification and quantification of five androgenic anabolic steroids in urine. Conventional methods for steroid analysis in urine rely heavily on one-dimensional GC separations and selected ion monitoring (SIM) MS methods. This study utilizes GC GC to increase peak capacity and resolution in combination with time-of-flight mass spectrometry (TOF-MS) detection followed by data processing with deconvolution software algorithms for positive confirmation of anabolic steroids in urine. A steroid mixture containing stanozolol (Winstrol), 4-hydroxystanozolol, boldenone, 19-norandrosterone, 17 -methylandrostan-3-17 -diol, and 3-hydroxystanozolol was prepared from commercial standards. Experimental results for the identification of 3-hydroxystanozolol at the 2-ppb level are presented. The illegal anabolic steroid stanozolol and metabolites are known to be particularly difficult to detect and separate chromatographically. Methyltestosterone was used as an internal standard (ISTD). Stanozolol was not included in the calibration curve development due to poor chromatographic response below 10 ppb. Although urine sampling is simple and easy to obtain, it poses a variety of challenges for the laboratory analyst. Sample preparation is labor intensive, complex, and difficult to reproduce consistently. Urine is a complicated biochemical mixture. The matrix effects from urine often can obscure detection of trace-level steroids and their metabolites. Instrumentation must be able to provide absolute confirmation of the analytical results. Sample preparation followed a well established extraction and derivatization procedure for antidoping control. Results from this study show significant improvements in chromatographic resolution and peak capacity, as well as the enhanced detectability that GC GC TOF-MS provides for antidoping control screening. Successful trace level identifications of the five steroid standards mixture will be shown at the 2-ng/mL (2-ppb) level. This exploratory research investigation demonstrates favorable and practical applicability of GC GC TOF-MS for the positive identification of anabolic steroids at the lowest allowable concentration limits which meet the strict guidelines set by the World Anti-Doping Agency (WADA). The increased peak capacity and enhanced chromatographic resolution of GC GC coupled with a fast acquisition TOF-MS, up to 500 Hz, is essential for the successful acquisition and analysis of the data density needed to characterize low levels of steroids fully in complex sample matrices such as urine. These data-rich files are processed with deconvolution algorithms, which deliver qualitative identification as well as a multiple compound quantification in a single run. The results show limitof-detection values at or below 2 ppb for five anabolic steroids with a calibration linearity of greater than 99.9%. Experimental Initial studies focused on the development of the sample acid hydrolysis and derivatization procedure, in addition to chromatographic (GC GC) and MS (TOF-MS) method optimization. Sample preparation was conducted with established protocols for steroid analysis in urine (1). Steroid reference standards were purchased from (Cerilliant,

2 of 7 7/11/2014 3:39 PM Round Rock, Texas) and (Alltech-Applied Science Labs, Deerfield, Illinois). A five-component steroid standards mixture was prepared in methanol. Serial dilutions were made from the steroid standards mixture and then spiked into 2-mL urine aliquots to create a working five point calibration at 2, 10, 20, 50, and 100 ng/ml. Methyltestosterone was spiked into the urine matrix at 200 ng/ml as an internal standard. Acid hydrolysis with beta-glucuronidase was carried out before solvent extraction with methyl- tert-butyl-ether. Extracts were dried completely using nitrogen evaporation. Trimethylsilyl-derivatization was conducted with a commercially available MSTFA-ammonium-iodide-ethanethiol mixture from (Sigma-Aldrich, Saint Louis, Missouri). A 3-µL pulsed splitless injection was used to analyze each sample immediately after derivatization. GC GC TOF-MS results were generated with a Pegasus 4D time-of-flight mass spectrometer (LECO, St. Joseph, Michigan). The Pegasus 4D GC GC TOF-MS instrument was equipped with a model 7890 gas chromatograph (Agilent Technologies, Santa Clara, California) featuring a two-stage cryogenic modulator and a secondary oven (LECO). ChromaTOF software (LECO) was used for all acquisition control, data processing, and calibration curve development. A 30 m 0.25 mm, 0.25-µm d f Rxi-5ms, (Restek Corp., Bellefonte, Pennsylvania) GC capillary column was used as the primary column for the GC GC TOF-MS analysis. In the GC GC configuration, a second column (1.2 m 0.18 mm, 0.20-µm d f BPX-50, (SGE Analytical Science, Austin, Texas) was placed inside the secondary GC oven after the thermal modulator. The helium carrier gas flow rate was set to 1.5 ml/min at a corrected constant flow via pressure ramps. The primary column was programmed with an initial temperature of 140 C for 0.20 min then ramped at 20 C/min to 170 C, next ramped at 5 C/min to 260 C for 2.0 min, with a final ramp at 10 C/min to 315 C for 12.0 min. The secondary column temperature program was set to an initial temperature of 145 C for 0.20 min then ramped at 20 C/min to 175 C, next ramped at 5 C/min to 265 C for 2.0 min, with a final ramp at 10 C/min to 320 C for 12.0 min. The thermal modulator was set to +20 C relative to the primary oven and a modulation time of 4 s was used. The GC GC TOF-MS analysis total run time was 39.2 min. The MS mass range was 45 750 m/z with an acquisition rate of 100 spectra/s. The ion source chamber was set to 230 C and the detector voltage was 1950 V with electron energy of 70 ev. GC GC TOF-MS analysis was conducted immediately after sample derivatization. Subsequently, calibration curves were developed and loaded into the software for automated data processing and quantification purposes. Method development achieved an optimized GC GC TOF-MS analysis capable of effectively separating the five anabolic steroids in complex urine matrix at or below 2-ppb detection limits. Results and Discussion Figure 1 Anabolic Steroid Identification: Successful trace level identifications of the five steroid standards mixture was achieved at 2 ng/ml with library search matches of greater than 60%. Calibration curve linearity of 99.9% or greater was attained. Over 5000 peaks per sample were detected for this analysis. Figure 1 displays the two-dimensional contour plot chromatogram of the 20-ng/mL standard GC GC TOF-MS analysis. The highlighted peaks show the labeled spiked steroids in urine throughout the chromatographic plane. The two-dimensional contour plot chromatogram clearly shows the ability of GC GC to maximize separation and resolution of anabolic steroids from the complex urine matrix in both the first and second dimensions. The three-dimensional surface plot chromatogram in Figure 2 shows a zoomed-in portion of the 20-ng/mL steroid GC GC TOF-MS analysis where stanozolol, 3-hydroxystanozolol, and 4-hydroxystanozolol are eluted. This figure is an excellent example of the increased peak capacity available with comprehensive two-dimensional chromatography. The stanozolol and hydroxystanozolols derivatize with one, two, or three trimethylsilyl groups. Each of the compounds, stanozolol, 3-hydroxystanozolol, and 4-hydroxystanozolol are eluted in the same first-dimension retention time modulation periods shown by the arrows in Figure 2. However, the same stanozolol and stanozolol-metabolites that are derivatized with fewer tri-methylsilyl groups are separated completely in the second dimension designated by the stars in Figure 2. This example illustrates how comprehensive two-dimensional GC GC fully resolves analytes that would otherwise be coeluted by one-dimensional chromatography. Figure 2 Meeting WADA Minimum Required Performance Levels for Detection of Prohibited Substances Table I shows the five steroid standards and the internal standard results of the low-level standards at 2 ng/ml, which is the WADA cut-off limit (2). The column labeled (QUANT S/N) lists the quantitative signal-to-noise ratio (S/N) for each steroid. S/N values for the five steroids ranged from 85 to 1353 at the 2 ppb concentration. The low-level cut-off

3 of 7 7/11/2014 3:39 PM Table I: Peak table for five steroids and steroid metabolites for the low level WADA cut-off limits at 2 ppb Table II: Calibration table used to develop calibration curves in ChromaTOF software guidelines are achieved and exceed the limits set by WADA. Limits of detection at a 10:1 S/N were calculated from the 2 ng/ml standard quant S/N results shown in Table I. The calculated limits of detection extend from 15 to 235 pg/ml in the part per trillion range. Calibration Curve Development A five point calibration curve was developed in the software in the concentration range of 2 100 ng/ml for each of the five derivatized steroid standards. Figure 3 illustrates the calibration curve developed in the software for 3-hydroxystanozolol (3TMS) with a first order linear correlation coefficient value of 0.99911. Calibration curve development for all GC GC results for the 2-, 10-, 20-, 50-, and 100-ng/mL steroid standards was achieved with greater than 99.9% linearity. The generation of quantitative calibration curves for the five steroid standards used in this study demonstrates the practical application of utilizing GC GC TOF-MS for anti-doping control screening. Mass Spectral Deconvolution Figure 3 The column headings in Table II show the steroid analyte name, absolute first and second dimension retention time, minimum and maximum concentration range for the calibration, the analyte type, curve fit, the first-order equation, and the calculated correlation coefficient for each standard. The calibration table developed for this research produced excellent linearity for all five steroids. Results for the calibration curve development yielded linearity of greater than 99.9% for the five TMS-derivatized steroid standards. Figure 4 displays a deconvolution example for the trace level concentration of the derivatized anabolic steroid (19-norandrosterone) at 2 ppb. It is coeluted and buried under the endogenous anabolic steroid peak, 5 -androst-16-en-3 -OL. The chromatogram in Figure 4 shows the extracted ion traces for the masses at m/z 315, 241, 57, and 117. The peak markers for the unique masses m/z 315 and 241 are separated by approximately 20 ms. The mass spectrum labeled A is the Caliper or (total ion mass spectra) before deconvolution. The mass spectra labeled B is the Peak True deconvoluted mass spectrum. The mass spectra labeled C is the library search match for the deconvoluted mass spectrum. A library match similarity hit of 749 out of 1000 was made for the 19-norandrosterone 2 ppb derivatized standard Figure 4 peak. This illustration clearly shows the deconvolution of a trace anabolic steroid even when it is buried in and masked under heavy sample matrix. Conclusion This challenging work accomplished the goals set for this research. Calibration linearity for quantitation was attained for all analytes at greater than 99.9%. Limits of detection were calculated from acquired data that achieved part per trillion sensitivity. This research demonstrated the ability of GC GC TOF-MS to provide improved and enhanced analyte detection, deconvolution of trace level concentrations of steroids from heavy sample matrices, as well as exceptional quantitation capabilities for the analysis of illegal anabolic steroids in complex urine sample matrix. The experimental results of this work established that significantly increased analytical performance was accomplished by utilizing comprehensive GC GC TOF-MS for anti-doping screening control. In conclusion the research outcome shows favorable and practical applicability of GC GC TOF-MS for the positive identification of anabolic steroids in urine at or below the lowest allowable concentration limits in compliance with the guidelines set by WADA. John Heim and Doug Staples are with LECO Corporation, St. Joseph, Michigan. References (1) Recent Advances in Doping Analysis (12), W. Schanzer, H. Geyer, and A. Gotzmann, U. Mareck, Eds. (Sport und Buch Straub, Koln, 2004), pp. 65 68.

4 of 7 7/11/2014 3:39 PM (2) World Anti-Doping Agency (WADA) Technical Document TD2009MRPL The World Anti-Doping Code: The 2009 Prohibited List; International Standard.

5 of 7 7/11/2014 3:39 PM

6 of 7 7/11/2014 3:39 PM

7 of 7 7/11/2014 3:39 PM Figure 1 Figure 2 Table I: Peak table for five steroids and steroid metabolites for the low level WADA cut-off limits at 2 ppb Figure 3 Table II: Calibration table used to develop calibration curves in ChromaTOF software Figure 4 2010 Advanstar Communications Inc.. Permission granted for up to 5 copies. All rights reserved. You may forward this article or get additional permissions by typing http://license.icopyright.net/3.7454?icx_id=667517 into any web browser. Advanstar Communications Inc. and Chromatography Online logos are registered trademarks of Advanstar Communications Inc. The icopyright logo is a registered trademark of icopyright, Inc.