Installation, commissioning and servicing instructions

Similar documents
Installation, commissioning and servicing instructions

Installation, commissioning and servicing instructions

CALEFFI. Inclined pressure reducing valves series 01024/17 GB. replaces 01024/14 GB

CALEFFI. Pre-adjustable pressure reducing valves with self-contained cartridge series 01085/17 GB. replaces 01085/14 GB

ACCREDITED H series Inclined pressure reducing valve sizes DN 15 (1/2 ) and DN 20 (3/4 )

Pre-adjustable pressure reducing valves with self-contained cartridge

ACCREDITED. Function. series 5360/

High Performance BSP Dial Up Pattern Pressure Reducing Valve

Function. Code Automatic filling units with pressure gauge connection Size 1/2 Code Automatic filling units with pressure gauge Size 1/2

Pressure reducing valves

Art PRESSURE REDUCER

TECHNICAL CATALOGUE PRESSURE REDUCING VALVES EUROPRESS

TECHNICAL CATALOGUE PRESSURE REDUCING VALVES EUROPRESS

Installation, commissioning and servicing instructions

553 Series.

ACCREDITED. Technical specifications series

TEC 1/2 3/4 DN A B C 32,25 32,25 F Kg/cm 2 bar LBS - psi

Filling valves AL, ALM Series Automatic filling units ALOMDIW, ALOMDNW Series

Pre-adjustable pressure reducing valves

valves Total Control.

Installation, commissioning and servicing instructions

Mounting and Operating Instructions EB 2555 EN. Self-operated Pressure Regulators. Pressure Reducing Valves Type 50 ES Type 50 EM.

Tempering valve for solar and instantaneous applications Installation, commissioning and servicing instructions 2522HP series

CALEFFI. Reduced pressure zone backflow preventer. 574 series 01022/18 NA D E C F B D E. Function

SEQUENTIAL SHOWER VALVE INSTRUCTION MANUAL PLEASE LEAVE THIS MANUAL WITH THE END USER

TEC 1/2 3/ /4 1 1/ /2 3 4 DN A B 125,5 125,

VG3000. Globe Valves Series for Terminal Units. Product Bulletin. 2-way PDTC (NO) with 6 bar close off pressure. Extend range of K VS

VG3000. Globe Valves Series for Terminal Units. Product Bulletin. 2-way PDTC (NO) with 6 bar close off pressure. Extend range of K VS

Mounting and operating instructions EB 2530 EN. Self-operated Pressure Regulator. Pressure Reducing Valve Type M 44-2

V311. Venta. Three-way Plug Valve, Flanged PN 16

differential pressure regulating valve - threaded

SINGER MODEL 106/206-RPS-L&H

WATER PRESSURE REDUCER (SBD)

Pressure independent control valve (PICV) FLOWMATIC

Technical data sheet. Type overview. Technical data. Safety notes. T5-R2.. Open-close en v Subject to changes 1 / 3


CAST IRON SAFETY VALVE TYPE 6301

PRESSURE REDUCING VALVE RP45 (EN)

RS(H)10,15 USER MANUAL. Read the complete manual before installing and using the regulator.

Pressure regulator for water

C 10 Pressure Reducing Valve

SRV66 Sanitary Pressure Reducing Valve

DS05C,D,G Dial Set Pressure Regulating Valves

Pressure reducing valves Index

Mounting and Operating Instructions EB 3007 EN. Self-operated Pressure Regulators. Differential Pressure Regulators (opening) Type Type 42-25

LRS(H)4 USER MANUAL. Read the complete manual before installing and using the regulator.

Seated valves VRB 3, VRG 3

Overview of types. T5-R B2/R B2 en v Subject to changes 1 / 4. k vs (Sequence 2)

HAYWARD FLOW CONTROL Series PBV Back Pressure Valve and Series RPV Pressure Relief Valve INSTALLATION, OPERATION, AND MAINTENANCE INSTRUCTIONS

Pressure Independent Control Series

MZX. Three-Port Seat Valves SPECIFICIATIONS AND GUIDE TO SELECTION

INSTALLATION, OPERATION

OPERATING INSTRUCTIONS

Dival 500 Pressure Regulators

Installation Operation Maintenance. Bermad Level Control Valve with Modulating Horizontal Float Pilot valve One Way Flow IOM.

Intamix Thermostatic Mixing Valve

Gas Check. Short testing time, with automatic start-up if no leakage was detected from previous operation.

Mounting and Operating Instructions EB 2558 EN. Self-operated Pressure Regulators. Type Pressure Build-up Regulator

TBV-CM. Combined control & balancing valves for small terminal units For modulating control

Two-port valves, male threaded, PN25

Deluge Optimo Shower valve and kit 10032CP

Overview of types. Technical data. Safety notes

DS06D,G Dial Set Pressure Regulating Valve

Differential Pressure Regulator Type Type 45-6 (0.1 to 1 bar, DN 15) Mounting and Operating Instructions EB 3226 EN

PRS(TC)4,8 USER MANUAL. Read the complete manual before installing and using the regulator.

E 158 E 198 E 248. Tank top mounting Connection up to G11 / 4 Nominal flow rate up to 250 l/min e d

D05 Pressure Regulating Valves

Engineering Data Sheet

Seated valve for steam (PN 25)

1800C and 1800C-HC Series Service Regulators

Pressure Reducing Valve DMV 750

Scald Protection Three-Way Thermostatic Mixing Valve

1200B2 Series Service Regulators. Instruction Manual

CALEFFI. Flow rate metering device. 683 series 01040/10 GB. Function

URINAL FLUSHING SYSTEM WITH MICROWAVE SENSOR

POP Safety Valve. POP Safety Valve INTRODUCTION DEFINITIONS

PRESSURE REDUCING VALVE EUROBRASS 143 FF

Pressure Reducing Valve for Steam Type 2333 A

6301 TYPE CAST IRON SAFETY VALVES

Thermostatic Mixing Valves 61022CPB & 61028CPB Intamix Pro V

HERZ-Motorised flow controler

WW-720. Pressure Reducing Control Valve

Pressure Relief Valve DHV 718

INSTALLATION INSTRUCTIONS

Installation Guide - C01202 & C01203 Thermostatic Mixing Valve TMV2

book : t95575.fm Seite 1 Mittwoch, September 20, :10 AM. Avensys. Exposed Single Lever Mixer

Mainsboost Installation, Operation & Maintenance Instructions

Model GP PRESSURE REDUCING VALVE Installation & Operation Manual

Materials : Brass body dezincification-resistant up to DN1 1/4

DN 1/2" to 2" Female BSP + 0 C C Max Pressure : 16 Bars Specifications : Stainless steel removable filter Female / Female With draining valve

THE MF-400 SERIES. Operating and Service Manual. Series includes all variants of MF-400/401

Function. brass EN CW617N brass EN CW617N brass EN CW614N. brass EN CW614N brass EN CW617N EPDM

Operating Manual. R280 Pressure regulator made of brass. 1. Intended Use

VALFONTA INSTRUCTIONS: OPERATION AND INSTALLATION PRESSURE REDUCING VALVE MODEL PRV44

Pressure Reducing Valve for steam RP 45

CALEFFI. DISCAL deaerator. 551 series 01060/17 GB. replaces dp 01060/14 GB

Versions. Benefits. Balancing DN15-32 DN40 DN50 DN15, DN20, DN25, DN32, DN40, DN50. Dimensions

VZL valve - 2/3/4-way

STAP. Differential pressure controller DN 15-50

TANDEM MODULATOR FOR OUTLET GAS FLOW: STEPPED (836 TANDEM) - CONTINUOUS (837 TANDEM) SERVO-CONTROLLED PRESSURE REGULATOR

Transcription:

3838.10 www.caleffi.com Inclined pressure reducing s opyright 2018 aleffi 33 series Installation, commissioning and servicing instructions Function Pressure reducing s are installed in residential water systems to reduce and stabilise inlet pressure from the water mains supply which is generally too high and variable for domestic appliances to function properly. These s can also be used to control inlet pressure to domestic hot water storage. The aleffi 33 series have been specifically designed and manufactured to meet the requirements of S137.2:200 Valves primarily for use in warm and hot water systems - P. 2: ontrol s. Product range of 02467 ode 33.. US Pressure reducing Sizes 1 mm (1/2 ) and 20 mm (3/4 ) Female connections (ISO 7/1) ode 330 US 3-way pressure reducing Size 20 mm (3/4 ) Female connections (ISO 7/1) Technical specifications Materials: ody: dezincification resistant alloy EN 1216 W602N over: P6G30 ontrol spindle: dezincification resistant alloy EN 12164 W724R artridge: POM omponents: dezincification resistant alloy EN 12164 W724R Diaphragm: EPDM Seals: NR-EPDM Strainer: stainless steel EN 10088-2 (ISI 304) Plug (3 way model): PPG40 Performance: Pressure setting range: 100 600 kpa; 100 00 kpa (code 330) Factory setting: 00 kpa Max. inlet pressure: 1600 kpa Max. working temperature: 40 Medium: water omplies with:

Dimensions D D 1/2 E ode 334 US 33 US 1 mm 22 mm 72, 72, 22, 22, D Ø 46 Ø 46 E Mass (kg) 79 0,4 84, 0,46 ode 330 US 3/4 72, E 0 D E Ø 46 82, Mass (kg) 0,49 Pressure drop diagram Under following conditions: Inlet pressure 600 kpa Outlet set pressure: 400 kpa p (kpa) 10 120 100 90 80 70 60 1/2 3/4 p (m w.g.) 1 12 10 9 8 7 6 0 40 4 30 3 20 2 10 1 Installation 0,2 0, 10 1 20 2 0 Flow rate (l/min) (m 3 /h) The pressure reducing must be installed by a licensed plumber and in accordance with S/ NZS 300, relevant local requirements and following these instructions. The installer must: - ensure the reducing is compatible with any other equipment in the system it may interact with or come into contact with logistically; - assess and acknowledge all hazards related to the use of the product, including leaks, by installing the unit properly; - install shut-off s fitted with pressure ports or similar equipment to measure the upstream pressure. Installation diagram heck Pressure reducing Line strainer (where fitted) Isolating 1/2 MINS SUPPLY 2

1/2 Straight outlet ngle outlet Inlet Outlet Inlet Plug Plug Outlet Pressure reducing Line strainer (where fitted) Isolating MINS SUPPLY heck System without recirculation STORGE HOT WTER HETER Tempering OLD WTER INLET 3

Recommendation for installation conditions When installed upstream of a hot water tank, we recommend installing an expansion vessel or similar equipment to absorb the increase in pressure due to the thermal expansion of the water. When installed in large buildings, adopt technical measures such as using short pipes or including expansion s and similar equipment to limit the increased pressure due to the thermal expansion of the water caused by temperature changes downstream of the reducing itself (or downstream of the first and second stage reducing s, if two are present). possible expansion possible expansion 1 stage PRV 2 stage PRV avitation diagram Upstream pressure (kpa) 2000 1600 1200 800 400 avitation high risk Normal working conditions Out of working conditions 100 200 400 600 800 1000 1200 Downstream set pressure (kpa) To minimize the risk of cavitation within the that may result in malfunctioning with erosion of sealing area, vibrations and noise, it is highly recommended to refer to the working conditions represented in the above diagram. Due to the numerous factors and variable conditions experienced such as system pressure, water temperature, air presence, flow rate and velocity, which may affect the behavior of the pressure reducing, it is advisable that the pressure ratio between the upstream pressure and the downstream set pressure is kept ideally to a value 2:1 and no greater than a value of 3:1. (For example, upstream 1000 kpa, set pressure 00 kpa, the pressure ratio = 1000/00 = 2:1). In these conditions, the possible risk of cavitation and malfunctioning is minimised, however this does not exclude the possible effects of the many other variables within the system under operating conditions. If the pressure ratio exceeds the indicated limit, the system design pressure or use of 1st stage pressure reducing s shall be reviewed. (For example, 1st stage reducing pressure from 1600 to 800 kpa and then 2nd stage from 800 to 400 kpa). 4

Pipework upstream and downstream of the pressure reducing shall be supported in accordance with the manufacturer s instructions, S/NZS 300 along with any other local authority requirements, to avoid the creation and transfer of vibration and/or noise into the installation. The inlet strainer of the pressure reducing shall be periodically checked and cleaned, to minimize any partial or complete blockage which may limit the flow rate from the and/or create noise. System flushing, cleaning and disinfection of the pipework to which the is installed shall be performed by suitably qualified persons in accordance with the system component manufacturer s instructions, S/NZS 300 along with any other applicable local authority requirements. Exceeding the maximum stated chemical concentrations and/or duration of exposure may negatively impact on the performance of the system and/or components installed such as the pressure reducing. hemical dosed products must be chemically compatible with materials used for the construction of the pressure reducing, specified in its technical documentation. Installation below ground If installing the 33 series underground, please ensure that steps are taken to protect the from becoming frozen in frost-prone areas. Please allow yourself sufficient space to remove the cartridge should maintenance be required. The reading of a gauge for setting purposes may be difficult and an alternate means of checking downstream pressure may ne necessary. Water hammering This is one of the main problems which may affect pressure reducing s. It is best to fit special devices to absorb water hammering when fitting pressure reducing s in systems at risk. WRNING: If it is critical to maintain the downstream pressure setting to protect equipment, as a safety measure, we recommend that a pressure, or safety, relief is installed downstream of the pressure reducing. Setting 1. Flush the system. 2. Install the pressure reducing in any position either vertically or horizontally, not upside down, paying attention to the direction of flow indicator on the body of the. 3. aleffi 33 series pressure reducing s are factory set at 00 kpa. 4. If required, reset the pressure by turning the screw on the top of the plastic cover. Turn it clockwise to increase the pressure and anticlockwise to decrease it. Maintenance The reducing must be checked and serviced in compliance with applicable regulations. Even when installed, commissioned and serviced properly, the reducing s internal components are subject to normal wear and tear, which may result in leaks and other malfunctions. We advise that you check that it is in good working order and service and clean the cartridge at least every 12 months. Proceed as follows for periodic cleaning of the strainer and inspection of the cartridge: 1 Turn off upstream water supply to the pressure reducing and open an outlet downstream to relief pressure

2 Unscrew (anticlockwise) the setting screw to decompress the spring inside. 3 Unscrew the cover. 4 Extract the cartridge with the aid of pincers to grip the head of the screw. fter inspection and cleaning, refit the cartridge or, alternatively, fit a replacement cartridge. 6 Reset the (see Installation). 2 3 4 Trouble-shooting 1. Increased downstream pressure near a water heater This problem is due to the water being heated by the water heater. There is no relief of the pressure because the reducing is correctly closed. The solution is to install an expansion vessel (between the heater and the reducer) to absorb the pressure increase. 2. The pressure reducing does not maintain its set pressure In most cases this is the result of impurities that deposit on the seat causing leakage with a resulting increase in pressure downstream. The solution is to fit a filter upstream from the reducer and subsequently to maintain and clean the cartridge (see Maintenance). Safety If the pressure reducing is not installed, commissioned and maintained properly in accordance with the instructions contained in this manual, it may not operate correctly, and may cause damage to objects and/or persons. Make sure that all the connections are water-tight. When installing the pressure reducing, make sure not to over-tighten the connections to the as, over time, a failure can occur with subsequent water leakage causing damage. In the case of highly aggressive water, arrangements must be made to treat the water before it enters the pressure reducing, in accordance with current legislation. Otherwise, the pressure reducing may be damaged and not function correctly. Leave this operating manual with the user LEFFI USTRLIN GENT ll Valve Industries Unit 2, 18-28 Sir Joseph anks Drive Kurnell NSW 2231 Ph: (02) 843 9811 Fax: (02) 843 9822 Email: info@all.com.au S.R. 229, n. 2 28010 Fontaneto d gogna (NO) Italy Tel. Int. +39 322 8491 R.. Fax +39 322 863723 Http://www.caleffi.com E-mail:info@caleffi.com