Hovacal DATASHEET JUNHO 2013

Similar documents
HumiSys HF High Flow RH Generator

The HumiSys. RH Generator. Operation. Applications. Designed, built, and supported by InstruQuest Inc.

PRODUCT CONFORMITY CERTIFICATE

MEGAS 2.0. Gas analysis with direct C-Level Calculation and Bus-Connection. Data sheet

Continuous gas analysis ULTRAMAT 23 Supplement 2 for Operating Instructions C79000-G52xx- C216-03

Analogue and Digital Mass Flow Meters and Controllers for Gases MASS-STREAM

Mass Flow Controller (MFC) for Gases

Features. Main Voltage: Vdc. Input Control Signal: 0-5 Vdc or 4-20 madc (Sourcing) Monitor Output Voltage: 0-5 Vdc or 4-20 madc (Sourcing)

IBEDA GAS MIXERS HIGHEST PRECISION FOR YOUR WELDING AND CUTTING PROCESSES

Model 601CV. Mass Flow Controller. Product Features:

Pneumatic high-pressure controller Model CPC7000

Mass Flow Meter (MFM) for Gases

Mass Flow Controller (MFC) for Gases

Instruction and Maintenance Manual

Digital Mass Flow Meters and Controllers for Gases

Generating Calibration Gas Standards

FTC130 Transmitter. Operating Manual

MCQ Gas Blender 100 Series 3 Channels Gas Mixer

Mass Flow Controllers

Instruction and Maintenance Manual

Pneumatic high-pressure controller Model CPC7000

UT 3000 Mercury Ultratracer

973-SF 6 Analyzer. Precise and Stable SF 6 Gas Analyzer REFLECTING YOUR STANDARDS

X-Flow Mass Flow Controller 授权代理 : 北京品超思瑞科技学院公司

MMS Mercury Monitoring System for Natural Gas

A Depletion Compensated Wet Bath Simulator For Calibrating Evidential Breath Alcohol Analyzers

Gas density monitor With integrated transmitter Model GDM-100-TI

Manual of SF6 Comprehensive Tester

Mass Flow Controller (MFC) for Gases

Digital dead-weight tester Model CPD8500

Porter Analytical & Industrial Products

Digital deadweight tester Model CPD8500

AC : MEASUREMENT OF HYDROGEN IN HELIUM FLOW

DSC 204 HP Phoenix. High-Pressure Differential Scanning Calorimetry up to 15 MPa Method, Technique and Applications

Mass Flowmeters. Mass Flowmeters for Gases

EuroFID Total Hydrocarbon Analyzer. Precise Determination of Total Hydrocarbons in Air for Corrosive as well as Condensing Gases

OXY Integral. INTERCON ENTERPRISES INC Tel: Fax: Internet:

ATEX VACUUM PUMPS AND GAUGES CHEMICALLY RESISTANT, OIL-FREE AND SAFE

Application Note AN-107

Continuous Gas Analysis In situ laser gas analyzers TÜV and MCERTS add-on for LDS 6 operating instructions Compact Operating Instructions

This multi-functional device allows the determination of up to six quality parameters with only one measurement:

Model GFC 7000T CO 2 Analyzer (Addendum to GFC 7000TA Manual, PN 07272)

DM01. Battery Powered Precision Digital Gauge. Stainless Steel Sensor. class 0.05

MASS FLOW SYSTEMS MASS FLOW MEASURING, CONTROLLING AND BLENDING SYSTEMS

DF-550E PROCESS ANALYSERS APPLICATIONS FEATURES

Series 6517 Katharometers. The ideal equipment for Process Monitoring and Control. Robust no moving parts. Designed for continuous industrial use

OxiQuant S. Operating Instructions

The M-Series Eletta Flow Meter High accuracy DP Flow Meter with multiple functions

FAST EVAPORATION AT NORMAL PRESSURE

Superior Result from Analytical Instruments The constant purity of the nitrogen improves system stability and ensures reproducible results

High-performance submersible pressure transmitter For level measurement Model LH-20

Minipuls evolution fitted with three 4-channel Medium Flow pump heads. one 4-channel Medium Flow pump head and one 2-channel High Flow pump head

PM105 PRESSURE METER USER S MANUAL

Technical Data Sheet High Performance Digital Gas Mass Flow Meters and Controllers Features Description

INSTRUMENT INSTRUMENT YL INSTRUMENT

Columbus Instruments

Drum-Type Gas Meters Series TG (Wet-Test)

Gas Absorption Column CAG

Laboratory Hardware. Custom Gas Chromatography Solutions WASSON - ECE INSTRUMENTATION. Engineered Solutions, Guaranteed Results.

Hidrostatic Level DATASHEET

RIGGTEK-Info, Page 1 of 16 DissoPrep X8 FAQ s

AIR-X COMPACT AIR-X ON-LINE LUBRICANT AERATION MEASUREMENT. Technical Brochure ON RUNNING ENGINES

DF-310E PROCESS ANALYSERS APPLICATIONS FEATURES

Title: Standard Operating Procedure for Dasibi Model 5008 Gas Dilution Calibrator

VersaFlow Vortex 100 Vortex Flow Meter Technical Datasheet. Specification. The all-in-one solution. Highlights. Industries.

Variable Area Flow Meters. VS Series

* Analysis of TCG ( Total Combustible Gas ) and 6 kinds of Gases * High Sensitivity for C 2

Measurement of Low GAS & Liquid Flows

combustion efficiency monitoring General Purpose Applications Flue gas oxygen analyzers Combustion & Environmental Monitoring An Company

Porter Lab & Analytical Products

ABB MEASUREMENT & ANALYTICS DATA SHEET. EasyLine EL3000 Series Continuous gas analyzers

DM01. Please visit our website: Battery Powered Precision Digital Gauge. Stainless Steel Sensor. class 0.05

Continuous Gas Analyzers, extractive

High-performance submersible pressure transmitter For level measurement Model LH-20

Easy with a modular concept for future expansion

High-performance submersible pressure transmitter For level measurement in hazardous areas Model LH-20

Flow VA 520. incl. temperature measurement. Intelligent solutions for ac- for compressed air and gases R 1/4 (DN 8) DN 15 R 3/4 (DN 20) DN 25

Flow VA 520. incl. temperature measurement. Intelligent solutions for ac- for compressed air and gases R 1/4 (DN 8) DN 15 R 3/4 (DN 20) DN 25

TF- & DM-Series. Turbineflowmeter

ETd 04. Battery Powered Precision Digital Gauge. Stainless Steel Sensor. Type: ETd 04. class 0.05

Analyze IT EL6010 Gas Analyzers in Category 2G

Flow metering in gases Introduction to COMBIMASS family

Appendix D: SOP of INNOVA 1412 Photoacoustic Multi-Gas Monitor. Description and Principle of Operation

GFM. Typical Aluminum GFM Mass Flow Meter NIST MASS FLOW METERS. Principles of Operation. Design Features

FAS-W. Features. Applications. Automatic condensation hygrometer

Additel 761 Automated Pressure Calibrators Selection Guide

Certification of AMS acc. EN 15267, Part 3 - Overview and First Experience -

Title: Standard Operating Procedure for Measurement of Ethylene (C 2 H 4 ) in Ambient Air by Reduced Gas Detection (RGD)

Industrial pressure controller Model CPC4000

Gas Diluter Portable Gas Dilution System User s Manual

SPECIFICATIONS PARTICLE SENSOR KS-19F Higashimotomachi, Kokubunji, Tokyo , Japan

Code Basic module and level control complete with optionals code

The. «Modular Alliance» Gas Generators. ALLIANCE, the partnership that keeps the gas flowing. One step ahead!

AND EQUIPMENT FOR ENVIRONMENTAL APPLICATIONS (800) B Polk Street Houston, TX

Agilent 7800 ICP-MS. Specifications and Typical Performance. Fast track metals analysis with Solution-Ready ICP-MS

ABB MEASUREMENT & ANALYTICS. Continuous gas analyzers EL3060 The specialists for hazardous areas

AFC. SDPROC and AFC Analog Mass Flow Controller ANALOG MASS FLOW CONTROLLERS. Principles of Operation. Design Features

Hot extractive multi-channel gas analyser for continuous process and emissions monitoring.

O3 3E 1 F Gas Sensor Module

Bubble Point / Pressure Decay Test / Gas Transport Rates through Membranes

Transcription:

Hovacal DATASHEET JUNHO 2013

Ho va Cal digital MF Calibration gas generator with integrated mass flow sensor

HovaCAL digital MF The calibration gas generator with integrated mass flow sensor For the generation of span gases with defined concentration of H 2 O, HCl, HF, NH 3 or HgCl 2 and the mixing of dry span gases like SO 2, NO x, CO, CO 2, O 2 and others. Technical advantages: liquid flow metering inside no need for an external electronic scale self-adjusting on given values direct indication of gas- and vapor concentrations one unit for all gaseous components remote operable concentration traceable to primary standards space saving, portable case What is HovaCAL digital MF? HovaCAL digital MF fulfills the desire for a compact calibration gas generator for all gaseous components of the emission measurement technology. Through an innovative mass flow technology made for liquids, there is no need for a gravimetric measurement trough an external electric scale. Thereby, it is not supposed to replace the electric scale as a primary reference method, but to provide a supplement: Whenever the setting up of an external scale is not possible, the integrated mass flow sensor handles this task with the same precision. Evaporator Vapor MFM Pump MFC1 MFC2 Heater Liquid Carrier gas Span Gas HovaCAL digital 211 MF 2

User interface viewcal 211 What can HovaCAL digital MF do? As with all the HovaCAL devices, a peristaltic pump carries the reagent solution into the evaporator. Hereby, a gas-vapor-mixture of the respective component is being generated. Through the quick response time of the mass flow sensor, a self-regulated operation is possible. This means, that the desired concentration of water vapor or of a dissolved component, like e.g. hydrogen chloride, is regulated to the set point of the gas concentration. HovaCAL digital MF has two to four gas channels for the dilution and mixing of dry span gases. Hence, the linearity check of emission measurement systems can take place also for dry components like SO 2, NO x, CO, CO 2 or O 2. Moreover, the defined humidification of span gases is possible, in order to determine cross sensitivities of analyzers or test the effectiveness of gas coolers. Handling HovaCAL digital MF can either be operated comfortably via the integrated touchscreen interface or via remote control from notebook/pc with the software viewcal. viewcal collects and saves all measurement data and enables an automatic operating. Moreover, viewcal allows the checking of the gas and liquid measurement. 3

Specification Flow ranges Gas flow controller 0,1/1,0/10,0 l/min (air) Liquid sensor 0,05 3,0 ml/min (Water or aqueous solution) Other flow ranges on request Typical concentration ranges Humidity 1,0 % Vol. 50 % Vol. (At total flow 300 l/h) Hydrogen chloride 0,1 2000 mg/m 3 (depending on reagent solution) Ammonia 0,1 1000 mg/m 3 (depending on reagent solution) Hydrogen fluoride 0,1 1000 mg/m 3 (depending on reagent solution) Mercuric (II) chloride 1 100 µg/m 3 (depending on reagent solution) Other concentration ranges on request Typical dilution range Dry span gases 1:1 1:1000 (At total flow 300 l/h) Other dilution ranges on request Performance based on reading Linearity < 2 % Accuracy < 2 % Range of variation < 2 % Reproducibility < 2 % Time characteristics Warming-up time T-90% 30 min 30 s for wet, < 10 s for dry components Adjustable parameter Total flow 180 600 l/h wet, 30 600 l/h dry Concentration inlet span gas Concentration outlet span gas, reagent solution each related to dry or wet gas Evaporator temperature up to 200 C Gas connection Supply unit Evaporator Applicable Media Gases Liquids Power supply Voltage Power front side 6 mm press fitting entrance and exit 6 mm press fitting instrument air, nitrogen, span gas, each 2 6 bar distilled Water, reagents (aqueous solutions) 110 V or 230 V, 48 62 Hz max. 1000 W Portable case Dimensions approx. 510 x 160 x 440 mm (W x H x D) Weight approx. 15 kg Evaporator Dimensions approx. 245 x 100 mm (H x B) Weight approx. 3 kg Suitcase housing IAS GmbH I Heddernheimer Landstraße 155 I 60439 Frankfurt am Main Tel.: +49 (0) 69 77 37 44 I Fax: +49 (0) 69 707 600 19 E-Mail: info@hovacal.de 4

Contactos/Contacts: Comercial/Commercial: Luís Ferreira da Costa e-mail: luiscosta@bhb,pt Tel: (+351) 21 843 64 00 Fax: (+351) 21 843 64 07 Assistência/Service: Joaquim Picante e-mail: jpicante@bhb.pt Tel: (+351) 21 843 64 00 24 Horas: (+351) 96 523 73 93