Scalding Now a Healthcare Worry Legionella Cases on the Rise Aging Population Safety Issues Hidden Costs of Status Quo ASSE 1016 Update

Similar documents
B LCTV_v3 4/27/04 10:54 AM Page 1 Series e700

Series e700 Combination T/P Valve Provides Unsurpassed Protection from Temperature & Pressure

Series e700 Combination T/P Valve Provides Unsurpassed Protection from Temperature & Pressure

mbing, Hydronics, Fire Protection and PVF The Authoritative Source ~CJ WINNER APEX ~ ~ AWARDS FOR PUBliCATION EXCELLENCE

DOMESTIC HOT WATER TEMPERATURE CONTROL with SAFEGUARD

Infection is caused by breathing in small droplets of water contaminated by the bacteria. The disease cannot be passed from one person to another.

Control of Legionella Policy. July 2017 ORCHARD ACADEMY TRUST. Control of Legionella Policy -Page 1

Introduction. Legal Duties. Risk Assessment

Issue date: April 2017

LEGIONELLA POLICY OUR LADY & ST JOSEPH CATHOLIC PRIMARY SCHOOL

CONTROL OF LEGIONELLA POLICY

TMV3 Requirements IMPORTANT Installer:

LEGIONELLA MANAGEMENT PROCEDURE

Cryptosporidium Incident Response

Legionnaires disease

Beta Study Report. Results of Nosocomial Infection Study In Whirlpool Bathing

Issue date: July 2012 Issue 1

Legionella Policy. Policy Ref: PS08. Prepared By. Georgina Kent, Operations Director. Date of Current Review August 2018

Warm Water Systems A Practical Guide. Based on over 24 years experience

Health & Safety Policy HSP 07 Legionella Management Version Status Date Title of Reviewer Purpose/Outcome

Scald Protection Three-Way Thermostatic Mixing Valve

Installation, commissioning and servicing instructions

Model TWBS.SH Tempered Water Blending System

TECHNICAL INSTRUCTIONS

Legionella Guidance. Property managers specialising in residential, apartment, block and estate management

Model 9201E Tempered Water Blending System

Scald Protection 3-Way Thermostatic Mixing Valve

Control of Legionella

Presented to the IAPMO Standards Review Committee on March 7, 2016

DB 61 Dolphin TMV3 Integrated Thermostatic Mixing Valve

Instruction Sheet. SUPERSEDES: New EFFECTIVE: August 1, 2013

WATER HEATER THERMAL EXPANSION TANKS Owner s Manual. Safety Instructions Installation Maintenance Warranty. Models: 2-5 Gallon Capacity

Legionella Awareness

Spring Loaded Regulators Constant Loaded Regulators Twin Parallel Flow Regulators Field Service Regulators

IHEA HFMC Stuart Lloyd. Managing Legionella: Achieving Best Practice. Legionella background

SMV-001 Thermostatic Shower Mixer Valve Installation Instructions & Adjustment Settings

Summary of Substantive Changes between the 2012 and 2018 editions of CSA B125.3 Plumbing Fittings

National Health Service Model engineering Specification

Discharge Relief Valve Operation & Maint.

Domestic Hot & Cold Water Services Log Book

EMERGENCY WALL MOUNTED HAND OPERATED DELUGE SHOWER

BACK PRESSURE / SUSTAINING

BACK PRESSURE / SUSTAINING

Installation Guide - C01202 & C01203 Thermostatic Mixing Valve TMV2

WW-720. Pressure Reducing Control Valve

Latvin Luxury Shower Panel. Telephone Product Specification. ~ Minimum Working Pressure 1.0 bar ~ Maximum Working Pressure 3.

bathrooms.com Concentric Thermostatic Shower Mixers Cleaning and Care Installation Manual Contents

AUTOVENT 4000 VENTILATOR

Intamix Thermostatic Mixing Valve

Pressure Balance Trim

I T T Pressure Reducing Valve WARNING INSTALLATION, OPERATION, AND MAINTENANCE MANUAL

Installation, commissioning and servicing instructions

LEAD FREE * Product Specification. Features n. Specifications n. Relay Specification n ! WARNING NOTICE

WW-720. Pressure Reducing Control Valve

Prevention and Control of Legionella Policy


acculink platinum zv zoning system

SCENARIO #2 CARBON MONOXIDE INCIDENT IN AN AUTO SHOP

The use of risk management as best practice to reduce outbreaks of recreational water illnesses in disinfected swimming facilities and spas

Atmos Low Pressure Thermostatic Bar Mixer Valve

GUARDIAN EQUIPMENT Emergency Eye Wash and Shower Equipment. ANSI Z358.1 Compliance Checklist

THERMOSTATIC MIXING VALVES

Licking County Health Department 675 Price Rd., Newark OH (740)

LEGIONELLA CONTROL POLICY

Pressure and/or Temperature Pilot Operated Steam Regulators Series 2000

Tempering valve for solar and instantaneous applications Installation, commissioning and servicing instructions 2522HP series

Technical Instructions

Installation, commissioning and servicing instructions

High Performance BSP Dial Up Pattern Pressure Reducing Valve

NORMAL OPERATING PROCEDURES Operating Parameter Information

Approved By H&S Forum

Deluge Optimo Shower valve and kit 10032CP

APPLYING VARIABLE SPEED PRESSURE LIMITING CONTROL DRIVER FIRE PUMPS. SEC Project No

Operation and Maintenance of the EPV200 Portable Ventilator

Installation, commissioning and servicing instructions

Legionella Management Policy

OWNER S GUIDE DUAL CONTROL THERMOSTATIC SHOWER VALVE. Shower Control. may differ depending on choice of Model. Concealing Plate. Handles and ISSUE 01

Policy No: 45. Legionella Emergency Action Plan

Thermostatic Mixing Valves 61022CPB & 61028CPB Intamix Pro V

COMPARISON OF DIFFERENTIAL PRESSURE SENSING TECHNOLOGIES IN HOSPITAL ISOLATION ROOMS AND OTHER CRITICAL ENVIRONMENT APPLICATIONS

1.0 PURPOSE 2.0 SCOPE 3.0 DEFINITIONS. ANSI: American National Standards Institute. CCC: Chemical Control Centre

Sullair Air Systems. *Assessment of the market for compressed air efficiency services. Technical report, U.S. Department of Energy, June 2001

Laboratory Safety Guideline Emergency Eyewash and Safety Showers

Optimizing Gas Supply for Industrial Lasers

Bermad Pressure Reducing. Model: 42T

OIL AND GAS INDUSTRY

Country report. Austrian bathing water quality in Austria. May Photo: Peter Kristensen

The Control of Legionella Bacteria in Water Systems. The Approved Code of Practice & Guidance L8.

ANSI Z Compliance Checklist

SEQUENTIAL SHOWER VALVE INSTRUCTION MANUAL PLEASE LEAVE THIS MANUAL WITH THE END USER

Series 8500 Expansion Compensators. Catalog 674H

Canadian Red Cross Summary First Aid Technical Changes for 2011 Implementation

15/3 THERMOSTATIC MIXING VALVE PRODUCT MANUAL IMPORTANT

WELCOME NEW FOOD/POOL SAFETY TEAM

OIL SUPPLY SYSTEMS ABOVE 45kW OUTPUT 4.1 Oil Supply

A Guide to Implementing an AED. Program

Twin & Triple Control Concealed Thermostatic Shower Valve

Cooling Tower Legionella Risk Assessment Checklist

Well Disinfection NONCOMMUNITY PUBLIC WATER SUPPLY PROGRAM

THERM-O-MIX STATION/WWM TEMPERED WATER SUPPLY

Transcription:

Scalding Risk Legionella Aging Population Hidden Costs Codes & Standards The Rising Need for Advanced Shower Valve Technology Scalding Now a Healthcare Worry Legionella Cases on the Rise Aging Population Safety Issues Hidden Costs of Status Quo ASSE 1016 Update

Foreward Much of the information in this report was prepared in response to specifying engineers, healthcare facility managers, and an increasing Scalding Risk 3 Legionella 4 Aging Population 5 Hidden Costs 6 number of inquiries from institutional and commercial facility managers who are concerned about shower valve safety. Powers welcomes any and all comments or questions regarding the content of this report. Codes & Standards 7 Comments or Questions? Please call 1-800-669-5430 x6207 Or email: info@powerscontrols.com Powers is a division of Watts Water Technologies, Inc. 2

Scalding Risk More than 112,000 individuals are admitted into hospital emergency rooms each year for scald-related injuries. American Hospital Association Medical statistics reveal that scald burns caused by hot water, flowing into the tub or shower, is the leading cause of severe burn injuries in the United States. Scalding cases have become so common in fact, that many hospitals have invested in scald victim treatment rooms. Why Are Scalding Incidents Rising? In 2002, an estimated 92,500 children ages 14 and under were treated in hospital emergency rooms for burn-related injuries. Of these, 22,600 were scald burns. National Safe Kids Campaign Children under the age of five, the elderly, and people with mental and physical disabilities are more susceptible to scald burns. However, while higher birth and aging trends have brought more incidents of scalding into the healthcare, public and legal arenas, the risk of scalding has long existed for several reasons. Thermal Shock is Another Danger Thermal shock is the physical reaction of a person to a rapid and uncomfortable change in shower water temperature. The temperature change can be either toward colder or hotter water. The danger of thermal shock is that the individual s sudden movement away from the water coming from the shower could cause a fall and serious injury. Effects of Water Temperature Plumbing that is lacking temperature control devices 140 F 1st degree burn, 3 sec. Improper plumbing maintenance or lack of maintenance Bathing of patients with delicate healing tissue concerns Inattentive bathing care of the elderly Unattended bathing of children, the handicapped, and the Normal dish/clothes washing and shaving range 130 F 120 F 1st degree burn, 30 sec. 1st degree burn, 8 min. elderly (those with diminished or undeveloped mental and physical capacities) 110 F Very hot shower 98.6 F Body temperature Causes of Temperature Change within a Plumbing System Seasonal temperature changes in water supply Authorized or unauthorized adjustment of upstream master tempering valve Failure of upstream tempering valve System pressure fluctuations, i.e. changing demand Boiler/hot water heater malfunction Improper valve selection (oversized) and/or hot water recirculation design Manufacturer Warnings / Forewarnings For years, shower valve manufacturers have included scalding warnings in the installation manuals that come with their pressureonly compensating shower valves. These pressure balancing shower valves have remained the prevailing valve choice, largely due to their relatively lower cost to facility owners and long time familiarity among plumbing contractors. See page 7 of this report for additional information about improved shower valve options. 3

Legionella on the Rise The CDC has estimated that the disease infects 10,000 to 15,000 persons annually in the US. OSHA estimates that over 25,000 cases of the illness occur each year, causing more than 4,000 deaths (CDC estimates 30% who contract will die), still others estimate as many as 100,000 annual cases and between 2002 and 2003, the disease has doubled or tripled in some regions of the country. Association of Water Technologies Legionella 2003, June, 2003 Bacteria Thrives in Water 68-122 F (20-50 C) Legionella is a type of pneumonia caused by Legionella, a bacterium found primarily in warm water environments. The disease can be contracted by inhaling airborne water droplets containing the bacterium. Legionella thrive within a narrow water temperature range of 68-122 F (20-50 C). Therein lies both the problem and the solution: To control the disease, facilities need to control the temperature of the water in their storage and delivery systems. Unless specifically targeted, many cases of Legionella are misdiagnosed as pneumonia because of symptom similarities. Even if detected, Legionella often goes unreported to public health authorities if incidences are low or are not associated with an outbreak investigation. Of the many hundreds of thousands of pneumonia cases that occur each year in the United States, some 10,000 to 100,000 are actually cases of Legionnaires disease. Effects of Water Temperature Legionellae Growth Chart Ideal growth range 95-115 F (35-46 C) Legionellae growth range 68-122 F (20-50 C) Rapid Kill Range 158-176 F (70-80 C) 50 F 75 F 100 F 125 F 150 F 175 F 10 C 24 C 38 C 52 C 66 C 79 C Below 68 F (20 C), Legionellae can survive but are dormant. Cold water in storage tanks, piping, decorative fountains, and other equipment should ideally be kept below 68F (20 C). Hot water need capability of heating water to 158 F (70 C) for disinfection 151 F (66 C) Legionellae die within 2 minutes 140 F (60 C) Legionellae die within 32 minutes 131 F (55 C) Legionellae die within 5-6 hours Control of Water Temperature is Critical OSHA, ASHRAE, the CDC and other authorities have all published recommendations to control Legionella. In every case, these authorities point to the water delivery system as being critical. OSHA recommends that domestic hot water should be stored at a minimum of 140 F (60 C) and delivered at a minimum of 122 F (50 C) to all outlets to minimize the growth of Legionella. In their latest guidelines for bacteria control and Legionella risk reduction, both the CDC and ASHRAE recommend hot Above 122 F (50 C) Legionellae can survive but do not multiply water recirculation at a minimum of 124 F (51 C) and installing temperature control valves at the point-of-use to reduce scalding risk. This health concern magnifies the importance of using a water delivery valve that is not of a pressure-only design, but is thermostatic or a combination of each to prevent scalding. 4

Our Aging Population The number of US citizens aged 65 and older will reach 70.18 million by 2030. This represents the highest ever, a full 20% of the population. Source: U.S. Census Bureau New High Risk of Scalding Injuries By 2050, the U.S. Census Bureau estimates our senior population will grow to in excess of 80 million, more than double its current size. Add to this the percentage of young children, and the total population most at-risk to scalding injuries will exceed 75%. Elderly people lose the ability to respond quickly Injuries occur due to falling when reacting suddenly to thermal shock Momentary exposure to excessively hot water can result in 2nd or 3rd degree burns Related incidents of scalding will increase with the aging population Increased scalding injuries will result in increased litigation The baby-boomer population will drive scald prevention legislation Population Growth Chart (in millions) 100 80 60 40 20 28.42 33.16 33.65 35.32 40.10 53.35 70.18 77.01 80.11 0 1985 1994 1995 2000 2010 2020 2030 2040 2050 Table 1 - Population ages 65 Years and Over: 1985-2050 (Source: US Census Bureau) A Painful Lesson Learned Hospital patients, those with disabilities or in physical rehabilitation, and most people within nursing facilities are known to have delayed reactions to a sudden rise in water temperature. Pain is the body s means of protecting itself. Yet illness or medication, as well as the delayed reactions of the elderly, can all affect the pain warning mechanism. For this reason, the aging population is exponentially exposing more people to the risk of severe tissue damage, burns, and death. Healthcare Facilities Finding the Cure The healthcare industry has been the first to evaluate an apparent Catch-22 dilemma. Decreasing hot water temperature in a delivery system reduces the danger of scalding, but increases the risk of bacteria growth. Increase the hot water temperature and just the opposite risks occur. Now add to this the need for energy conservation and the common practice of reducing thermostat settings for water heaters and the conclusion to all of this has revealed itself: Past methods of water delivery are no longer adequate. 5

Hidden Costs WARNING: Failure to adjust the limit stop screw properly may result in serious scalding. CAUTION: This valve does not automatically adjust for inlet temperature changes, therefore someone must make the necessary Rotational Limit Stop adjustments at the time of the installation and further adjustments may be necessary due to seasonal water temperature change. YOU MUST inform the owner! CAUTION: Due to season temperature change of the cold water supply, the temperature limit must be readjusted accordingly to maintain the desired maximum discharge temperature. Leading Manufacturers of Pressure Balancing Type Shower Valves Old Problem Under New Scrutiny To prevent a person from drawing water that is dangerously hot, pressure balancing valves come with a limit stop that needs to be installed and adjusted seasonally to allow for cold water temperature changes flowing into the water system. For decades, this limitation in pressure valve design has prevailed despite the manufacturer warnings and cautions. Limit Stops Are Rarely Adjusted Common sense and common practice are two different things. While manufacturers have long warned facility managers to routinely and seasonally set the limit the stop on all of their shower valves, the cost and aggravation of doing so defies common practice. Take for example, a 500-room facility. With twice-annual seasonal adjustments, and allowing just 10 minutes per valve, and at an hourly rate of $25 per hour, the annual cost for setting the limit stops would be $4,166. As early as the 1980 s, the Consumer Product Safety Commission warned of the need to set the temperature-limiting devices on pressure balancing type shower valves. In a June 1984 report, the Commission reported it was aware of 12 incidents, including 4 deaths, associated with a single brand of pressure balancing shower valve. And yet, today, pressure balancing type shower valves continue to be specified at the risk of being improperly installed and without seasonal adjustment in motels, hotels, apartments, nursing homes, institutional care facilities and athletic facilities. Anticipating a rise in litigation related to scalding injuries, specifiers, installers, and facility managers now have an additional potential cost to consider when installing pressure type shower valves a cost that can be significantly higher than the proper installation of limit stops and perennial limit stop adjustments. Seasonal Cold Water Adjustments HOT WATER TEMPS Seasonal cold water increase & affect on type P valves* PRESSURE BALANCING RESPONSES F C F C 125.0 F 160 71 128 53 52.0 C 140 60 120 49 100 38 80 27 60 16 40 5 20-7 0-18 115.0 F 46.0 C 117.5 F 47.5 C 120.0 F 49.0 C 122.5 F 50.0 C 40 F 50 F 60 F 70 F 80 F 5 C 10 C 16 C 21 C 27 C COLD WATER TEMP. 124 51 122 50 120 49 118 48 116 47 114 46 112 44 110 43 * without adjustment of limit stop OUTLET WATER TEMP. 6

A Higher Standard The American Society of Sanitary Engineers (ASSE), with its membership of shower safety valve manufacturers, has authored performance standards that govern water safety valves. ASSE 1016 governs point-of-use shower valves ASSE recognizes three basic types of bath and shower valves Type P Pressure balancing valves for pressure regulation Type T Temperature valves for temp and some pressure regulation Type T/P Both temperature and pressure regulating valves The Limits of Pressure Balancing Valves Type P While pressure-balancing valves will compensate for pressure fluctuations within a plumbing system, these types of valves cannot make adjustments for sudden or gradual changes in supply temperature. If hot water supply line temperature unexpectedly increases to a dangerous level while inlet water pressure remains constant, the pressure balancing valve will continue to pass water but at a dramatically increased temperature. Pressure balancing valves react to water pressure changes only. They are not designed to sense temperature changes and so do not provide true temperature regulation. Pressure balancing valves can provide some level of protection against scalding when limit stops are adjusted seasonally. Pressure balancing valves do not provide complete protection when coupled with upstream thermostatic valves (master mixers) in the event of a valve failure. WARNING: This shower system may not protect the user from scalding when there is a failure of other temperature controlling devices elsewhere in the plumbing system. Type T/P Valves Prevent Problems Also known as combination valves, Type T/P valves are required to meet ASSE 1016 s most stringent performance requirements for both temperature and pressure changes. Type T/P valves allow water to be generated at higher temperatures, distributed at higher temperatures, and delivered at safe temperatures to the bather alleviating the risks of scalding and the growth of Legionella bacteria in a water delivery system. In addition, Type T/P valves require no seasonal adjustment of the limit stop, saving potentially thousands of dollars over the life of a system. Valve Type Protection Provided per ASSE 1016 Point-of-use Hot Water Supply pressure temperature fluctuations increases up to 50% -Type P- NO YES Pressure Balance Leading Shower Valve Manufacturer -Type T- Thermostatic YES NO The Limits of Common Thermostatic Valves Type T -Type T/P- Combination YES YES Handle only 20% pressure fluctuations, not 50% Very expensive, 3 to 4 times that of pressure balancing Other ASSE Standards ASSE 1017 Hot water distribution (Powers Series MM430, SH1430) ASSE 1070 Water tempering at sinks and lavatories (Powers model e480) ASSE 1069 Water tempering to gang or multiple showers (Powers model LM495) ASSE 1062 Temperature activated, flow reduction valves (Powers model HT115) 7

ASSE 1016 T/P Technology Total Protection is Now Affordable Powers has developed the first affordable type T/P shower valve to minimize the risk against scalding, Legionella, and the elimination of labor costs associated with pressure balancing valve limit stop adjustments. The e700 features an improved valve design and actuation technology, and is priced competitively with less protective Type P and T valves. Originally developed for healthcare facilities, the e700 valve is now being widely specified for institutional, commercial, lodging, sports and recreational facilities to provide the highest ASSE 1016 rated solution. Powers has also introduced the first T/P valve for lavatory tempering as well, the e480 for total bathroom protection. For a free brochure or to talk to a Powers engineer, please call 1-800-669-5430. Or visit: www.powerscontrols.com USA: Phone: 1.800.669.5430 Fax 1.847. 229.0526 www.powerscontrols.com Canada: Phone: 1.888.208.8927 Fax 1.888.479.2887 www.powerscontrols.ca F-P-SRSVS 0811 2008 Powers