TESTING AT VERY LOW FLOWRATE

Similar documents
Blower Door Operation Manual

What is Pressure? Residential Pressure Measurement

Blower Door Operation Manual

CONSERVATORY DIAGNOSTIC TOOLS TO MEASURE BUILDING PERFORMANCE

Operation Manual. Software. FanTestic Integrity (complying with NFPA 2001) rev

Window and Door Measurement System

B. Diagnostic Equipment Information 01 Number of Manometers Used to Measure Home Pressurization Manometer Make. Manometer Serial Number

B. Diagnostic Equipment Information 01 Number of Manometers Used to Measure Home Pressurization Manometer Make. Manometer Serial Number

Additel761 Series Firmware Updates

Blower Door Operation Manual

Pegas 4000 MF Gas Mixer InstructionManual Columbus Instruments

ISO 6570 INTERNATIONAL STANDARD. Natural gas Determination of potential hydrocarbon liquid content Gravimetric methods

Overview ASTATT3. Carry out air tightness testing for single dwellings and other small buildings

Air Pressure Test to EN13829:2000

In Response to a Planned Power Outage: PPMS EverCool II Shut Down and Re-start Procedure

Air Leakage Detailing & Awareness Services

This addendum describes the back pressure control implementation if FuelCell Version 4.1a and later.

Boyle s Law: Pressure-Volume Relationship in Gases

[MYLAPS INTEGRATION]

Code Basic module and level control complete with optionals code

Building air tightness

ISO INTERNATIONAL STANDARD. Gas cylinders Cylinder valves with integrated pressure regulators Specification and type testing

Automatic Isokinetic Sampler. ST5 Evo

Duration: 4 hours Type: self-learning 2h and class room lectures 2 hours. Dr.sc.ing. Anatolijs Borodiņecs

HAP e-help. Obtaining Consistent Results Using HAP and the ASHRAE 62MZ Ventilation Rate Procedure Spreadsheet. Introduction

Push Button Minute Timer Programmable between 1 minute and 30 minutes with built in multi-way control

Manual. NatVent IAQ office ventilation program NaVIAQ V1.3

NSAI Agrément Approval Scheme for. Certified Air Tightness Tester Scheme Master Document

Agilent Auxiliary Gas Module AGM 2. User s Guide

This test shall be carried out on all vehicles equipped with open type traction batteries.

Results of Field Measurements and CONTAM Simulation. Building Science

GN21 Frequently Asked Questions For Golfers

User Manual 1 P a g e Rev. V1.6-EN 11/08/2014

Pneumatic high-pressure controller Model CPC7000

SHIMADZU LC-10/20 PUMP

MANUAL. P C - C E N T E R Version Copyright by Dinand van het Reve CONTENTS

BASIC Z-STACK AND TIME SERIES SCAN ON THE ZEISS LIGHTSHEET Z. 1

Race Screen: Figure 2: Race Screen. Figure 3: Race Screen with Top Bulb Lock

2600T Series Pressure Transmitters Plugged Impulse Line Detection Diagnostic. Pressure Measurement Engineered solutions for all applications

Operation Manual. rev Software. Clean Agent Retrotec Inc.

General Accreditation Guidance. User checks and maintenance of laboratory balances

Operation Manual. rev Pressure Gauges DM-2

Building Official's Guide to Duct Testing based on 2009 IECC

GN 2 CONSTANT FLOW REGULATORS. GUIDANCE NOTE GN 2 Constant Flow Regulators. Page 1 COMMISSIONING SPECIALISTS ASSOCIATION.

Mac Software Manual for FITstep Pro Version 2

Help Manual. (ROAD Edition)

Model 130M Pneumatic Controller

Panther 5 Acute Care Ventilator

Additel 761 Automated Pressure Calibrators

WARRANTY, QUICK START GUIDE

GolfLogix: Golf GPS. User Guide for: BlackBerry Curve. Version 1.0. Software Release , 8330, 8350i, 8800, 8820, 8830, 8900

nvisti Kestrel Companion Pro For Android

Help Manual. (ROAD Edition)

UNITY 2 TM. Air Server Series 2 Operators Manual. Version 1.0. February 2008

Four common PRESSURE CALIBRATION PAIN POINTS

The HumiSys. RH Generator. Operation. Applications. Designed, built, and supported by InstruQuest Inc.

Additel 761 Automated Pressure Calibrators Selection Guide

Quick Start Guide. A. Hardware installation B. Software installation C. Start the software for the first time D. Do your first measurement

Additel 761 Automated Pressure Calibrators

FRDS GEN II SIMULATOR WORKBOOK

ADT 761 Automated Pressure Calibrator

Standard Operating Manual

1. Study the performance of a binary distillation column operated in batch mode.

Help Manual. (ROAD Edition)

Additel 761 Automated Pressure Calibrators

GolfLogix: Golf GPS. User Guide for: iphone 3G & 3GS. Version 1.0. Software Release 1.0

ISO INTERNATIONAL STANDARD. Small craft Watertight cockpits and quick-draining cockpits

FX134, FX1234, FX3030 Problem and Solutions

ISO INTERNATIONAL STANDARD

10 The Performance Assessment Report

RUNNING A MEET WITH HY-TEK MEET MANAGER

ISO INTERNATIONAL STANDARD. Hydraulic fluid power Filter elements Determination of resistance to flow fatigue using high viscosity fluid

High Performance Electronic Components 1411 S. Roselle Rd Schaumburg, IL Fax

TR Electronic Pressure Regulator. User s Manual

BAPI Pressure Line of Products - FAQs

SPLIT HOPKINSON PRESSURE BAR OPERATIONS MANUAL 5/9/2014

Additel 761 Automated Pressure Calibrators Selection Guide

PRODUCT MANUAL. Diver-Mobile for Android

INSTRUCTION FOR FILLING OUT THE JUDGES SPREADSHEET

Agilent Flowmeter ADM1000

Ammonia Synthesis with Aspen Plus V8.0

DM-2 Operation Manual

Edge Isolation Tool. Standard Operating Procedure. Version 1.1. Date: Prepared by, Sandeep S S. Department of Electrical Engineering

Diver-Office. Getting Started Guide. 2007, Schlumberger Water Services

#LZ400 LEAKALYZER. Water Loss Sensor INSTRUCTION MANUAL Country Dr. #190 St. Paul, MN

Operation Manual. rev Pressure Gauges DM32. Retrotec Inc.

PROCESSOR UNIT - V3 WITH WIRING. Spring limit M180 and ROF 25bb/s

Stirley Barn Pressurisation Test Fri 13-Dec-2013

Single Pressure/ vacuum decay leak rate, loss, rate of loss, or occlusion tests with standard Cv valves.

SPIROVENT VACUUM DEGASSERS

ELIMINATOR COMPETITION DRAG RACE Program Manual Firm Ver 4.11

( ) ( ) *( A ) APPLICATION DATA. Procidia Control Solutions Coarse/Fine Control. Split-Range Control. AD Rev 2 April 2012

Using the GHIN Handicap Allocation Utility with GHP Golfer

Pressure Gauge Operation Manual

ISO INTERNATIONAL STANDARD. Mechanical vibration Balancing Guidance on the use and application of balancing standards

PROCESSOR UNIT - V2. Spring limit M180 and ROF 25bb/s

Ideal gas law. Introduction

Bante821 Portable Dissolved Oxygen Meter Instruction Manual

ASE SOLVENT CONTROLLER INSTALLATION INSTRUCTIONS Dionex Corporation

All Sport 5000 Control Console

Transcription:

TESTING AT VERY LOW FLOWRATE Author : Valérie Leprince (PLEIAQ) for BCCA npo August 2018 Buildings are becoming tighter and tighter, leading to test at very small flowrate compared to the volume of the building. Airtightness testers sometimes experience difficulties to perform tests in such airtight buildings. Those difficulties are due to two issues: the pressure and/or flowrate are difficult to stabilize. the device used may not be able to measure at a small enough flowrate (for example when testing small shops or student dwellings) This document explains the reasons behind those difficulties, gives advice to perform a test at very low flowrate and gives the flowrate limits of classical devices. 1 WHAT IS THE ISSUE WHEN TESTING A VERY AIRTIGHT BUILDING? 1.1 THE PRESSURE AND FLOW RATE ARE DIFFICULT TO STABILIZE When a building is very airtight and very large, the flow rate needed to maintain the building at a constant pressure is very small compared to the volume. However, due to the compressibility of air, the amount of supplied air (in m³) needed to reach 50 Pa is proportional to the volume. Therefore a large amount of air is needed but is provided by a small flow rate, so it may take time for the pressure to reach the required 50 Pa. This is like trying to inflate a car tire with a bicycle pump. Furthermore, it could be necessary to adjust the parameters of the fan's control in order to take into account the specific conditions of very airtightness buildings, because it may take longer than to reach a stabilized pressure. For example, in a very tight and very large building (200 000 m 3 ), up to 5 minutes were needed to reach a stable pressure at 50 Pa (100m³ or 120kg air is needed). In a very airtight building it was also observed that it takes a long time to get back to the initial pressure when the test stops. 1.2 THE DEVICE IS NOT ABLE TO PERFORM THE MEASUREMENT AT SMALL FLOW RATE ACCORDING TO THE TECHNICAL SPECIFICATIONS STS-P71-3 In some cases the flow rate required to reach the low pressure point is below the range of the measuring device. This problem can be experienced when measuring a very small and airtight volume such as a small shop independent of the rest of the building on the ground floor, or student dwellings. In this case the measurement device won't be able to perform the measurement at low pressure point or will but with a large uncertainty. Information is given in section 3 of this document to check the compatibility between measurement devices and the tested building. 2 PRACTICAL ADVICE TO PERFORM THE TEST 1

To ease a test in a very airtight/very large building the following recommendations can be followed: Not to use an automatic fan control Try to assure that the temperature inside the building stays as constant as possible during the test as heating or cooling the air causes it to expand or contract and this changes the pressure Cruise on the fan flow rather than on the pressure of the room It is also important to notice that varying external parameters such as wind or other occupant behaviour (when testing a dwelling in a multi-family building) will further complicate the stabilization of the flow rate and pressure. Therefore those tests shall preferably be performed in no-wind conditions and occupants of adjoining apartments shall not open doors and windows during the test. 2.1 USE A SEMI-AUTOMATIC FAN CONTROL When a test is performed on a very airtight building it is better not to use an automatic fan control, but to use software that shows the change in pressure and flow rates to determine when pressures are stable and you are ready to start sampling data. It is better to increase the recording duration for each point in each pressure difference up to 60 or even 120 seconds. 2.1.1 WITH MINNEAPOLIS BLOWERDOOR If the test is performed with TECLOG it is possible to see the building pressure evolution and start the recording when a plateau is reached. If TECTITE Expresse is used then use a sample rate between 500 and 1000 data points per target pressure. The test takes slightly longer but the additional points are useful in order to reach a better uncertainty. Use the semi-automated test if it takes longer than 120 seconds to stabilize the pressure of the room; guidelines to perform such a test with Tectite are given in the Annex. 2.1.2 WITH RETROTECD The automatic test mode on FanTestic will attempt to reach target pressure with a time-out of 240 s. Once timeout is reached the user will be prompted and can continue trying to reach pressure (without having the fans stop). To improve the odds that automatic mode will work, increase the number of samples over which the average is taken when FanTestic is determining if the room pressure has been achieved (part of the pressure target arrival criteria ). (see Annex for details on this) In cases where the Automatic mode keeps timing out or is not able to stabilize on a target pressure, users can switch to using semi-auto at any time during a test. Before an automatic test, use the Set Pressure option on the DM32 gauge and try for 50 Pa. If the DM32 has trouble stabilizing during Set Pressure, you know you will need to do a Semi-Auto test, and control fan speed directly. 2.2 TRY TO MAINTAIN THE TEMPERATURE IN THE BUILDING CONSTANT 2

Temperature variations induce pressure change, so heating or cooling the indoor air may induce pressure variation in the building. If the heating or cooling system is able to modulate its output quickly enough to maintain a constant heating or cooling rate, then it can be left running during the test. However, if the heating or cooling system is not able to maintain a constant temperature then it is better to turn it off and, if possible, to keep the building at the outdoor temperature during the test. It is better to avoid large temperature differences between inside and outside the building. 2.3 CRUISE ON THE FAN FLOW RATHER THAN ON THE PRESSURE OF THE ROOM If the test is performed manually, the following procedure can be done: - Increase the flow rate manually - maintain the flow rate constant until the pressure is constant - adjust the flow rate and wait until the pressure is constant (redo this step until the required pressure is obtained) When the flow rate is constant and the pressure constant at the required pressure, record pressure and flow rate. 2.3.1 WITH MINNEAPOLIS BLOWERDOOR In TECTITE Express it is possible to use the semi-auto mode (see annex) to perform the test this way. The user can control the fan by turning the knob of the speed controller. When the pressure and flowrate is constant, the user can press "start sampling". In this case, before starting the test, it is good to increase the samples per station to 500 to 1000 data points. This process is easier and much more understable with TECLOG as it shows the graph of the pressure evolution. The tester can see and choose the optimal readings 2.3.2 WITH RETROTEC In FanTestic the semi-auto mode (see Annex) is provided to control the speed of the fan from the software and capture the data when the user determines that the room pressure and flowrate are stable. The user can monitor the pressure in the room and the flowrate using FanTestic until the target has been reached and then press "Capture data". Each target point in the test can be performed this way. In cases where the Automatic mode keeps timing out or is not able to stabilize on a target pressure, users can switch to using semi-auto at any time during a test. They can also add target points to an existing test, or delete bad captured target data and re-do the target point using semi-auto. 3 LIST OF DEVICES AND CORRESPONDING FLOWRATE /TESTABLE VOLUME/AIRTIGHTNESS 3.1 HOW TO MAKE SURE THAT YOUR DEVICE IS ABLE TO PERFORM THE TEST According to the tested zone and the available device, the following calculation can be performed to estimate the minimum v50 (v50;min, in m³/h per m² envelope area) measurable. Information needed: S : envelope area of your building (area used in the calculation of the v50) in m² 3

n: flow rate coefficient, the average value is 2/3 but in very tight building with very small leakage it can reach almost 1, to perform a safe side calculation n=1 shall be used Qmin: minimum flow rate your device can test (see Table 1) in m³/h ΔPmin: minimum pressure difference to reach, in no wind conditions or temperature difference ΔPmin=10 Pa v 50;min = ( 50 n ) P min Q min S For example for a Model 4 Minneapolis Blower Door (Qmin= 19 m 3 /h), in a dwelling with an envelope area of 100m², you may not be able to perform the test according to STS-P 71-3 if the dwelling is tighter than v50=0.95 (the lowest target pressure of 10 Pa may not be reached). For very tight buildings the leakage of the equipment used to test become very important and therefore additional taping may be needed. 3.2 MINIMUM FLOWRATE REACHABLE BY CLASSICAL DEVICES The table below sums up the minimum flow rate reachable by classical devices in the market Table 1: Minimum flow rate reachable by devices Mineapolis Blowerdoor Model 4 19 m 3 /h Minifan (Duct Blaster B) 5 m 3 /h Micro Leakage meter 0.17 m 3 /h Retrotec Model 5000 series 15.5m 3 /h Model 300 series 9.1m 3 /h 4 DISCLAIMER AND COPYRIGHT The published material is being distributed without warranty of any kind, either expressed or implied. The responsibility for the interpretation and use of the material lies with the reader. In no event shall BCCA npo be liable for damages arising from its use. Any responsibility arising from the use of this report lies with the user. Only two brands and products are mentioned, however it does not mean a value or quality judgement of these products and brands. Retrotec and Blowerdoor Minneapolis have been involved in the writing of this document. BCCA vzw - Aarlenstraat 53, 1040 Brussel All rights reserved. Unless otherwise specified, no part of this publication may be reproduced or utilized in any form or by any means, electronic of mechanical, including photocopying and microfilm, without permission in writing from the publisher. 5 ANNEX 4

5.1 HOW TO PERFORM A TEST WITH TECTITE EXPRESS IN VERY AIRTIGHT BUILDINGS 5.1.1 WITH VERSION 4.1 AND 5.1 Starting with the update of TECTITE Express to version 4.1 and in the current version 5.1 the software gets an extra method Semi- Auto in order to do a semi-automated test. The semi-automated test is used for buildings or dwellings if it is not possible to do an automated test because of: a very good / excellent airtightness unsteady wind adjoining building parts with disturbing pressure fluctuations or a combination of these points. The difference between an automated and semi-automated test are during the automated test the software controls the fan speed up and down and in the semi-automated test the tester controls the fan speed up and down. 5.1.1.1 TRY TO ADJUST THE SETTINGS IN AN AUTOMATED TEST During a fully automated airtightness test, the computer is in charge of adjusting the fan to reach the desired (or target) building pressures. In the automated test the software jumps after finishing data sampling for one target pressure to the next target pressure. Then the fine-tuning starts in order to get as near as possible to the target pressure. If the pressure fluctuation is too large and it isn t possible to get a stable (constant) building pressure within 120 seconds, the software stops the fan and shows the message excessive building fluctuation and the user has the possibility to change settings of the automated control. One of the settings is the "fan adjust rate". The fan adjust rate determines how quickly the fan speed changes as the computer tries to achieve the target building pressure. For most cases, the default fan adjust rate of 1.0 will work fine. In some cases it may be necessary to reduce the fan adjust rate to prevent the fan from responding too quickly. In a tight building, the fan adjust rate can be reduced to 0.2 so that the fan adjusts slowly enough to help complete the test. Note that the test will take longer. If it is still not possible to get a stable building pressure with that setting, this is a reasonable sign for the tester to switch to the semi-automated test. 5

5.1.1.2 THEN SWITCH TO A THE SEMI-AUTOMATED TEST The advantage of the semi-automated test is that the user has unlimited time to adjust the fan and that the tester decides to start sampling data points for each target pressure. More information on the semi-automated test is available on the Reference guide BlowerDoor Standard or Reference guide BlowerDoor MiniFan (https://www.blowerdoor.com/en/services/downloads/referenceguides/it is also recommended to increase the number of samples per target pressure (station) up to 500 1000. 5.2 USE RETROTEC FANTESTIC TO TEST TIGHT ENCLOSURES Retrotec FanTestic has always had a Semi-automatic mode to allow users to have control over the fans but still allow them to capture data in an automatic way. In cases where the Automatic mode keeps timing out or is not able to stabilize on a target pressure, use semi-auto. You can switch to using semi-auto at any time during a test, and can add points to an existing test (as long as you are using the same gauge/fan combination(s)). If you are in the midst of an automatic test, click Stop Test, and then use the Begin Semi-Auto button. Before starting a test, Retrotec recommends doing a check of the building with the fan(s) using just the gauge tap the Set Speed on the gauge and set it to 50% to see how the building responds, and try other speeds to characterize the building before the automatic test. Stop the fan and then tap Set Pressure on the gauge and try for 50 Pa (or the maximum required for your test). With this you can determine if the range is set correctly (if you get fan pressure too low warning, change to a more restrictive one, if you reach 100% speed, go to a larger range). This way you can get your fan set up with the best range for the highest pressure before the test starts, and in many cases there will not be a range change required. You can also check your minimum required target pressure to see if a range change will be required. If the gauge itself has trouble stabilizing during Set Pressure, you know you will need to use a Semi-Auto test, and control fan speed directly. 5.2.1 TRY AUTOMATIC MODE To improve the odds that automatic mode will work, increase the number of samples over which the average is taken when FanTestic is determining if the room pressure has been achieved (part of the pressure target arrival criteria ). Open Settings>>Advanced Options>>Settings Tab. Set this number to be 30-50, but remember to change it back if your tests are reaching pressure more easily in a different building and FanTestic is waiting too long to start capturing data. After you change this setting you must start a new test. 6

You can switch to using semi-auto at any time during an automatic test. You can also add points to an existing test (as long as you are using the same gauge/fan combination(s)). If you are in the midst of an automatic test, click Stop Test, and then use the Begin Semi-Auto button. 5.2.2 USE SEMI-AUTOMATIC MODE If the gauge itself has trouble stabilizing during Set Pressure, you know you will need to use a Semi-Auto test, and control fan speed directly. Use the Begin Semi-Auto button to open the Semi-Auto Window: 7

Choose which gauge you want to control (or all at the same time) and set the fan speed to a value. Click on Run fan(s) with new target. When the room pressure and flowrate are stable, click on Collect Data Point. You can choose which target point to save the data into, and you can choose how long to capture data for on each target point. The saved data shows up in the main screen of FanTestic, just as an automatic captured target point would. More information on using the semi-automatic mode is provided in the FanTestic User Manuals provided in the Help menu of FanTestic (so you always have access) or at the following download link: https://retrotec.com/manuals-guides 8