Digital Melting Point Apparatus

Similar documents
Sample Concentrator SBH CONC/1 Instructions for use

HI 2314 HI 2315 HI 23151

NovelBright LED Illuminator

New AQF Filter Polymer Filtration System

EC214 EC215 - EC215R Bench Conductivity Meters

MODELS (2 foot Version) (4 foot Version)

METEOR LSR36500 LIGHTING UNDERWATER POOL LIGHT. Operating Instructions

973-SF 6 Analyzer. Precise and Stable SF 6 Gas Analyzer REFLECTING YOUR STANDARDS

PORTABLE WORK LIGHT MODEL NO: CL6FS OPERATION INSTRUCTIONS PART NO: GC0315

Dual Solenoid Gas Valve Installation

Stirring Water Bath. Instruction Manual

Operating Instructions Part No

Rigel 601 CHECKBOX. Instruction Manual. 348A551 Issue 2.0. April Seaward Electronic Ltd. Issue 2.0

Operating Instructions Part No

Vertex VP Operation and Maintenance

User Manual. Precision and Analytical Balances ME-T

User s Guide Temperature Sensor Converter TSC-599

G92 Series BASOTROL Automatic Pilot Gas Valve

RAM 4021-DPX Operation Manual

! Warning, refer to accompanying documents.

L230 LED 40 Watt Searchlight

36H SERIES Combination Gas Valve

Pressure Injection Cell Operator s Manual

POWER ASSISTED BICYCLES OWNERS MANUAL

SC505 Sof Care Inflator. Operating Instructions and Service Manual

RAM 4021 Operation Manual

Measurement accessories METPOINT OCV for the measurement in systems up to 40 bar

USER MANUAL. JET TST and JET TST S.

Product instruction manual Easymount Sign Laminators EM-S1400C, EM-S1600C, EM-S1400H, EM-S1600H

Model 687 Mouse Ventilator User s Manual. Model 687 Mouse Ventilator

Operating Instructions Temperature Measuring System MF420-5T-100

Operating instructions Safety Rope Emergency Stop Switches ZB0052 / ZB0053 ZB0072 / ZB0073

PRODUCT SUPPORT MANUAL YACHT BEAM 6M Searchlight Remote Control System with Joystick Remote Control Panel

Budget Range Operators Handbook

Digital Vacuum Regulator

PLEASE READ CAREFULLY BEFORE INSTALLING OR USING MEGA POOL SAVER MPS 1100

Pectoral Machine. User manual E S S E N T I A L S T R E N G T H

RAM Operation Manual. Worldwide Manufacturer of Gas Detection Solutions

Ambient Weather GL150-TH Nautical Thermometer Hygrometer (ComfortMeter) User Manual

WXG-4 Manual Polarimeter. Instruction Manual BANTE INSTRUMENTS CO., LTD

OEM Manual MODEL 2305 ECONOMICAL DIGITAL SINGLE CYLINDER SCALE

RAM 4021-PR. Operation Manual. Worldwide Manufacturer of Gas Detection Solutions

INSTRUCTION MANUAL FOR MODEL 7360V VERTICAL CURING CHAMBER Revision E May

Operating Instructions

RAM Operation Manual. Worldwide Manufacturer of Gas Detection Solutions

BGA244 Binary Gas Analyzer

Calibration Gas Instrument INSTRUCTION MANUAL. Release I. Advanced Calibration Designs, Inc.

[ACT 005] Manual E 5/25/05 9:24 PM Page 3 MULTI-FUNCTION

SPS-5. Rate Computing Scale. Operation Manual

12V Mini Air Compressor

Instruction Manual BA90 Precision Barometer

OPERATOR S MANUAL Ar-Gone Weld Gas Analyzer

12V MINI AIR COMPRESSOR

RAM Operation Manual

Bante810 Benchtop Dissolved Oxygen Meter Instruction Manual

12V AIR STATION ALL-IN-ONE

USER GUIDE TO POWER ASSISTED BIKES

METEOR LSR0640 UNDERWATER POOL LIGHT. Operating Instructions

3G Operating instructions. Digital Purge Gas Valve 3G Type: Document no.: D0001 Version: 01. July 2011/Rev.

G96 Series BASOTROL Dual Operator Valve

VERTICAL AIR COMPRESSORS

ATEX ATEX

G196 Series BASOTROL Redundant Combination Gas Valve with Manual Shutoff Valve

Regalia Oxygen Concentrator

WHERE TO INSTALL THIS MIRROR

9A5N Solid State CW Paddle

PLAQUE MFM0680 UNDERWATER LIGHT. Operating Instructions

G196 Series BASOTROL Redundant Combination Gas Valve with Manual Shutoff Valve

User's Manual. Heavy Duty Dissolved Oxygen Meter. Model

KERN EG/EW Version /02

AutoChanger Installation & User Guide Issue 2

BGA158 Series CE Approved Class A Shutoff Gas Valve

THE UNIVENTOR 400 ANAESTHESIA UNIT

Safety. Operating instructions Solenoid valve for gas VG 6 VG 15/10 DANGER. Contents WARNING CAUTION. Changes to edition 09.14

D10S/D20S Wall/Post Mount Inflator Quick Start Manual

OPERATING MANUAL EASY-LOAD PUMP HEADS

Norrsken Family Booklet

BI-680 Online Dissolved Oxygen Controller Instruction Manual

plasmarc air curtain For use with m3 Plasma System and PT-36 Plasma Torch ESAB Assembly Number: Instruction Manual gas the bottom of the plate.

RPS900W Redundant Power Supply. Installation Guide.

36E DSI and HSI Two-Stage Combination Gas Valve INSTALLATION INSTRUCTIONS

Installation, operating and maintenance Instructions for Seemag bypass level indicator

SAUTER FK Version /2016 GB

Standard Gas Countertop Griddle

VERTICAL AIR COMPRESSORS

e.do Gripper Safety requirements, technical features and assembly and integration instructions

with O 2 Controller Instruction Manual

RADROVER REAR RACK INSTALLATION MANUAL

AIR COMPRESSOR OPERATION & MAINTENANCE INSTRUCTIONS MODEL NO: CHAMP 3 PART NO: LS0115

WIKA INSTRUMENT CORPORATION

E X R A D I N Spherical Ion Chambers A3. A4 REF DOC #

Operating Manual. Models AQT-02 & AQT-COO2 Manual No. MON004 (Rev 2 April 2000)

36G22, 36G23, 36G24 & 36G52 36J22, 36J23, 36J24 & 36J52 DSI and HSI Single Stage Combination Gas Valve

DPC-30 DPC-100. Reference Manual

Digital pressure gauge Model CPG500

Research Grade Blood Pressure Transducer User's Manual

Please read these instructions carefully before use! Please consider the safety instructions! Please keep for future reference!

MS-H-S10/MS-M-S10 Hotplate/Magnetic Stirrer

BGA158 Series CE Approved Class B Shutoff Gas Valve

T i m i n g S y s t e m s. RACEAMERICA, Inc. P.O. Box 3469 Santa Clara, CA (408)

Transcription:

Digital Melting Point Apparatus Heating Plateau Ramping Start/Stop Plateau set Ramp stop Hold User Guide Version 1.1

Heating Viewing tube Sample Chamber IEC power inlet socket Power on/off Temperature display Extendable feet Plateau Ramping Start/Stop Ramp stop Hold Plateau set Control panel Instruction label Figure 1 Heating Heating Plateau Plateau Ramping Ramping Stop Start/Stop Plateau set Ramp set Plateau set Start Hold Figure 2 03011-30 & 03011-35 Control panel Figure 3 03012-07 & 03012-17 Control panel (High-resolution version) 2

Digital Melting Point Apparatus Introduction Thank you for purchasing this Cole-Parmer product. To get the best performance from the equipment, and for your own safety, please read these instructions carefully before use. Before discarding the packaging check that all parts are present and correct. This equipment is designed to operate under the following conditions: For indoor use only Use in a well ventilated area Ambient temperature range 5 C to 40 C (41 F to 104 F) Altitude to 2000m (6500ft) Relative humidity not exceeding 80% Power supply fluctuation not exceeding 10% of nominal Overvoltage category II IEC60364-4-443 Pollution degree 2 IEC664 Use with a minimum distance all round of 200mm (8 in.) from walls or other items If the equipment is not used in the manner described in this manual and with accessories other than those recommended by the manufacturer, the protection provided may be impaired. Electrical Installation THIS EQUIPMENT MUST BE Grounded Before connection please ensure that the line supply corresponds to that stated on the rating label. Power requirements: 230V Models 120V Models 03011-35 75W 03011-30 75W 03012-17 75W 03012-07 75W The Digital Melting Point Apparatus is provided with a UK 3-pin and a Schuko 2-pin plug for 230v installations and a NEMA 5-15 plug for 120v installations. Should the cable not be suitable for connecting to the power supply, replace the plug with a suitable alternative. THIS OPERATION SHOULD ONLY BE UNDERTAKEN BY A QUALIFIED ELECTRICIAN. NOTE: Refer to the equipment rating plate to ensure that the plug and fusing are suitable for the voltage and wattage stated. The wires in the power cable (230V) are colored as follows: BROWN - HOT/LIVE BLUE - NEUTRAL GREEN/YELLOW - EARTH 3

The wires in the power cable (120V) are colored as follows: BLACK - HOT/LIVE WHITE - NEUTRAL GREEN - EARTH IF IN DOUBT CONSULT A QUALIFIED ELECTRICIAN Should the power cable need replacing, a cable of 1mm 2 of harmonized code H05W-F connected to an IEC320 plug should be used. The appropriate power cable should be connected BEFORE connection to the power supply. General Description The Cole-Parmer Digital Melting Point Apparatus has been designed for maximum safety and ease of use. The temperature is selected, measured and displayed digitally, ensuring accuracy and avoiding the need for a glass thermometer. Two samples can be tested simultaneously. They are viewed via a magnifying lens with clear observation aided by built-in illumination. Extendable feet allow the unit to be operated at the optimum viewing angle. Full access to the block allows easy cleaning and maintenance. Optional Instruction Label Select the appropriate choice of self-adhesive instruction label from the multi-language set provided. Peel off the backing and apply the label onto the left side of the control panel. Apply the label carefully using a flat object to smooth away air bubbles. Safety Advice Users should be aware of the following safety advice: HIGH TEMPERATURES ARE DANGEROUS as they can cause serious burns to operators and ignite combustible material. USE CARE AND WEAR PROTECTIVE GLOVES TO PROTECT HANDS. DO NOT use combustible substances near hot objects. Never lift or carry the instrument until it has been switched off and allowed to cool for at least 30 minutes. The Heating light will give guidance. The unit should be carried using both hands with the fingers under the side edges. Never move or carry the unit while still connected to the power supply. DO NOT position the unit such that it is difficult to disconnect it from the power by removing the power cable from the socket at the back. 4

Before Use Place the Digital Melting Point Apparatus on a firm, level surface and extend the feet at the rear of the instrument so that the unit is at a convenient viewing angle. Connect to the power supply and switch the unit ON using the power On/Off switch. The actual block temperature will now be shown on the three-digit LED display and the illumination in the sample chamber will come on. Operation The Digital Melting Point Apparatus has been designed to give both quick and accurate results as well as maximum convenience in use. Melting point samples are placed in a glass capillary tube which is placed in the aluminum block inside the sample chamber. This block is heated and the sample observed through the magnifying lens on the viewing tube until the melt occurs. The melting point temperature may then be easily read from the large LED display. In order to avoid the necessity to continually watch the sample, the unit is equipped with a plateau function. This allows a temperature to be set a few degrees below the expected melting point. The unit will then heat to this temperature very rapidly (20 C per minute) and hold it until the operator is ready to begin measuring. It is safe to leave the unit unattended during this plateau function. 03011-30 and 03011-35 The unit will heat slowly (2 C per minute) from the plateau temperature until the melt occurs. This slow rate of heating allows very accurate melting points to be obtained. 03012-07 and 03012-17 (High-resolution version) It is possible to adjust the ramp rate between 1ºC per minute and 10ºC per minute. This allows either a fast result to be obtained or a more accurate slow one. Measuring a Melting Point Caution: The heating block may be HOT. Note: If the unit has been used recently the block may be too hot for your sample. If this is the case, press the stop button and allow the unit to cool before proceeding. 1. Prepare sample by placing a small amount in the end of a glass capillary tube. 2. Decide on a suitable plateau temperature. This should be approximately 10 C below the expected melting point of the sample. 3. Check that all three function lights are extinguished. If not, press the stop button. 4. Press and hold the Plateau Set button (the plateau light will flash). The display will now show the current plateau temperature. 5. The desired plateau temperature may now be set using the arrow keys to scroll the display up or down as required. 6. Release the Plateau Set button. The new plateau temperature is now set and all function lights will go out. (The plateau setting can be checked at any time during operation by pressing and holding the Plateau Set button. This action will not interfere with the operation of the unit.) 5

7. High-resolution version only: Decide on an appropriate ramp rate, between 1ºC and 10ºC per minute. Results obtained at 1ºC per minute will be the most accurate, while more approximate results can be obtained faster at higher ramp rates. Setting the ramp rate is the same procedure as setting the plateau except you need to use the Ramp Set button instead of the Plateau Set button. 8. Insert the tube into the side of the heating block via the holes provided. For convenience this can be done from either side of the block. Look down the magnifier and position the viewing tube so that the sample can be observed clearly. 9. Press the Start or Start/Stop key. The unit will quickly heat up to the plateau temperature (the heating light will be illuminated - see Figures 2 and 3). 10. Once the plateau temperature has been reached the plateau light will be illuminated as well as the heating light - see Figures 2 and 3). NOTE: At low plateau temperatures, there may be some overshoot. Wait until the plateau light comes on before proceeding in order to ensure that the temperature has stabilized. 11. Press the Start button again. The block will begin to heat at the pre-set ramp rate (highresolution units) or at the fixed 2 C per minute (the plateau light will go out and the ramping and heating lights will both be illuminated - see Figures 2 and 3). 12. Observe the sample until the melt occurs and record the temperature from the digital display. 13. High-resolution version only: It is possible to freeze the temperature display using the Hold button. Once pressed, the temperature display will hold (ramping light flashing) to allow more time to record the melt temperature. Press Hold again to return to the actual block temperature. 14. After the melt has occurred, press the Stop or Start/Stop button. All function lights will go out and the unit will cool to ambient temperature. 15. Pressing the Start button again will cause the unit to return to the plateau temperature instead of ambient. The heating light will come on even if the temperature is above the plateau and the unit is, in fact, cooling. Cleaning and Care WARNING: Ensure the unit is disconnected from the power supply before attempting maintenance or servicing. The unit should be cleaned using a damp cloth and a mild detergent solution. Cleaning is made easier if spillages are attended to promptly. In any case, spillages of acids and alkalies MUST be removed immediately as these chemicals can attack and damage the casework finish. Ensure that the appropriate safety precautions are observed. Broken melting point tubes may be removed from the block simply by pushing them through with a piece of wire or similar tool. For access to the block the sample chamber cover must be removed. 1. Remove the three retaining screws and lift off the cover. 2. Loosen the screw retaining the metal plate but do not remove completely. 3. Push the plate to one side. 4. The glass window in the top of the block may now be removed. 6

Servicing and Repair This product range does not require any routine servicing. Note: There are no internal user replaceable parts. Note: There are fuses mounted on both the live and neutral line. In the event of product failure it is recommended that any repair is only undertaken by suitably qualified personnel. For advice, please contact Cole-Parmer quoting the model and serial number. Only spare parts supplied by the manufacturer or its agent should be used. Fitting of non-approved parts may affect the performance of the safety features of the instrument. If in doubt, please contact Cole-Parmer. 7

Warranty Cole-Parmer warrants this equipment to be free from defects in material and workmanship, when used under normal laboratory conditions, for a period of three (3) years. In the event of a justified claim, Cole-Parmer will replace any defective component or replace the unit free of charge. This warranty does NOT apply if: Any repair has been made or attempted other than by the manufacturer or its agent. Any minor coating chips or scratches occur during normal use (i.e., wear and tear). Damage is caused by fire, accident, misuse, neglect, incorrect adjustment or repair, damage caused by installation, adaptation, modification or fitting of non-approved parts. 8

Calibration Certificate Catalog Number Serial Number Calibration Date Temperature readings Set temp. C Measured temperature C 60 C ±0.5 100 C ±0.5 200 C ±1.0 Quality Assured Cole-Parmer 625 East Bunker Court Vernon Hills, IL 60061-1844 Toll-Free: 800-323-4340 Phone: 847-549-7600 Fax: 847-247-2929 www.coleparmer.com 9

Technical Specification 03011-35 03012-17 Number of samples 2 2 Temperature range Ambient to 300 C (572 F) Ambient to 300 C (572 F) Temperature resolution 1 C 0.1ºC (High-resolution) Temperature accuracy at 20 C ±1.0 C ±1.0 C Digital display 3-digit LED 4-digit LED Light source White LED White LED Sensor PT100 PT100 Ramp rates 20 C/minute to plateau 20 C/minute to plateau Fixed 2 C/minute to melt Between 1 and 10ºC/min Dimensions (WxDxH) 160 x 220 x 170 mm 160 x 220 x 170 mm (6.3 in. x 8.6 in. x 6.7 in.) (6.3 in. x 8.6 in. x 6.7 in.) Electrical supply 230V, 50/60Hz 230V, 50/60Hz Fuses T1A T1A Net weight 1.8 kg (3.9 lbs) 1.8 kg (3.9 lbs) 03011-30 03012-07 Number of samples 2 2 Temperature range Ambient to 300 C (572 F) Ambient to 300 C (572 F) Temperature resolution 1 C 0.1ºC (High-resolution) Temperature accuracy at 20 C ±1.0 C ±1.0 C Digital display 3-digit LED 4-digit LED Light source White LED White LED Sensor PT100 PT100 Ramp rates 20 C/minute to plateau 20 C/minute to plateau 2 C/minute to melt Between 1 and 10ºC/min Dimensions (WxDxH) 160 x 220 x 170 mm 160 x 220 x 170 mm (6.3 in. x 8.6 in. x 6.7 in.) (6.3 in. x 8.6 in. x 6.7 in.) Electrical supply 120V, 50/60Hz 120V, 50/60Hz Fuses T1A T1A Net weight 1.8 kg (3.9 lbs) 1.8 kg (3.9 lbs) 10

These products meet the relevant EC harmonized standards for radio frequency interference and may be expected not to interfere with, or be affected by, other equipment with similar qualifications. We cannot be sure that other equipment used in their vicinity will meet these standards and we cannot guarantee that interference will not occur in practice. Where there is a possibility that injury, damage or loss might occur if equipment malfunctions due to radio frequency interference, or for general advice before use, please contact the manufacturer. Declaration of Conformity Catalog Number: Description: 03011-30 Digital Melting Point Apparatus 120V 03011-35 Digital Melting Point Apparatus 230V 03012-07 HIGH-RESOLUTION Digital Melting Point Apparatus 120V 03012-17 HIGH-RESOLUTION Digital Melting Point Apparatus 230V This product complies with the requirements of the EU Directives listed below: 2004/108/EC 2006/95/EC 2011/65/EC EMC Directive Low Voltage Directive (LVD) RoHs Directive

For technical, sales or servicing information, contact: Cole-Parmer 625 East Bunker Court Vernon Hills, IL 60061-1844 Toll-Free: 800-323-4340 Phone: 847-549-7600 Fax: 847-247-2929 www.coleparmer.com