Versatile Filtered Power Entry Module

Similar documents
3-phase Line Reactor to reduce mains disturbances

1-phase Filters FN Multi-stage General Purpose EMI Filter. Approvals. Typical electrical schematic. Technical specifications

1-phase Filters FN Multi-stage High Performance EMI Filter. Approvals. Technical specifications. Typical electrical schematic

1-phase Filters FN Multi-stage Performance EMI Filter. Approvals. Typical electrical schematic. Technical specifications. Typical applications

Power Quality Increased Reliability. Components

FMAC Sine FMAC Sine DCL

Efficient EMC Solutions

VLT 2000 Series. How to size your VLT

Applications. What moves your world

For Air Pressure. AP-30 Series. Digital Display & Digital Control. EASY-TO-SEE 2-color display. Two-color digital display pressure sensor

Limit switches OsiSense XC Special For material handling applications, type XC1 AC

Tolerance code. Lead space

KGW - ISOTHERM. Operating Instructions. Level controlling device for liquid nitrogen LEVEL CONTROL LN2

Valve Proving System VDK 200 A S06*

Valve Proving System VDK 200 A S02

DIAPHRAGM GAS SAMPLING PUMPS

Watts. xppower.com. Input. General. Environmental. Output. EMC & Safety. Output Voltages from 2.5 V to 48 V. Non-standard Outputs Available

CHEMICALLY RESISTANT DIAPHRAGM GAS SAMPLING PUMPS

DIAPHRAGM VACUUM PUMPS AND COMPRESSORS

h2000 plus HyDROGEN LEAk DETECTOR

X2 Metallized Polypropylene Film Capacitor JFV

Dual Modular Safety Shutoff Valves with Two-stage operation and Proof of Closure DMV-ZRD/612 Series DMV-ZRDLE/612 Series

Dual Modular Safety Shutoff Valves with Two-stage operation. DMV-ZRD/602 Series DMV-ZRDLE/602 Series

Dual Modular Safety Shutoff Valves with Two-stage operation and Proof of Closure. DMV-ZRD/612 Series DMV-ZRDLE/612 Series

N SERIES PROCESS VACUUM PUMPS AND COMPRESSORS

CHEMICALLY RESISTANT DIAPHRAGM GAS SAMPLING PUMPS

Dual Safety Shutoff Valves with Proof of Closure and NEMA 4x Enclosure. DMV-D/624L Series DMV-DLE/624L Series

X2 Metallized Polypropylene Film Capacitor JFV

2-Phase Filters(Direct IEC Connector) RoHS. 250V AC 50/60Hz 1,2,3,6,10A KC, UL, CSA, VDE+ENEC, TÜV, CQC, 25 / 85 / 21

MANUAL KPS Pressure Control Valve

Dual Modular Safety Shutoff Valves with Two-stage operation. DMV-ZRD/602 Series DMV-ZRDLE/602 Series

better measurement Simply a question of SCHMIDT Flow Sensor SS The cost-effective alternative in pressurised systems up to 10 bars.

Dual Safety Shutoff Valves with Proof of Closure and NEMA 4x Enclosure. DMV-D/624L Series DMV-DLE/624L Series

DMK 458. Pressure Transmitter for Marine and Offshore. Ceramic Sensor. accuracy according to IEC 60770: standard: 0.25 % FSO option: 0.

Better to have one OXYLOG 3000

SCH-27. Diaphragm Pressure Switch. Setting range: mbar to bar. Temperature: max C. Material: stainless steel

ORB-400 BUBBLE/HAZE MACHINE. Item ref: UK User Manual

Certified according to DIN EN ISO 9001 Technical Datasheet TRICOR Series Mass Flow Meters

Dual Modular Safety Shutoff Valves with Proof of Closure. DMV-D/622 Series DMV-DLE/622 Series

DIAPHRAGM VACUUM PUMPS WITH KNF STABILIZATION SYSTEM

GasMultiBloc Combined regulator and safety valve Infinitely variable air/ gas ratio control mode MBC-300-VEF MBC-700-VEF MBC-1200-VEF

Electric regulating valves Type CCMT 2 - CCMT 8 / CCMT 16 - CCMT 42

TERMINAL BLOCK SUMMARY

Single and double acting, magnetic, self-centering Bores: ø 16, 20, 25, 32, 40 mm

Differential Probes TDP1500 and TDP3500 Datasheet

DIAPHRAGM VACUUM PUMPS AND COMPRESSORS

GAS SAMPLING PUMPS WITH KNF DOUBLE DIAPHRAGM SYSTEM

Dialight LED Conveyor Light - CE / RCM. for Indoor and Outdoor Industrial Applications

Series AM3T-VZ 3 Watt DC-DC Converter

Datasheet IEC & ANSI Miniature or Standard Quick Wire Thermocouple Connector Plug & Socket Type K in IEC or ANSI Colour code

Application Notes. Aluminium Electrolytic Capacitors

CONTENTS TABLE OF MAIDA S HISTORY TERMINOLOGY & GENERAL SPECIFICATIONS. iii. LEAD CODES and TAPE & REEL STANDARD SERIES 1 HC SERIES 17

Dual Modular Safety Shutoff Valves. DMV-D/602 Series DMV-DLE/602 Series

Selected by Experts. Schmalz Select. Preferred Product Range for Vacuum Technology

Quick Reference Guide Power Series Switches

Automatic Valve Proving Control

1 Overview. Pressure Measurement Single-range transmitters for general applications. 1/22 Siemens FI

DIAPHRAGM VACUUM PUMPS AND COMPRESSORS

Guidelines to the standard IEC60601

THE POWERFUL LEAK DETECTOR FOR ALL APPLICATIONS IN POWER PLANTS

Dual Modular Safety Shutoff Valves. DMV-D/602 Series DMV-DLE/602 Series

PIKO IQ 4.2, Plenticore plus 4.2 Rating: 10,0kW 8,5kW 7,0kW 5,5kW 4,2kW Rated voltage: PIKO IQ 8.5, Plenticore plus 8.5

Principal Operations in Japan

PVK OPEN LOOP PUMPS. Bulletin E

2/ Port G1/4

COSMO INSTRUMENTS CO., LTD.

Heinen & Hopman Engineering

Certificate of compliance

DIAPHRAGM VACUUM PUMPS AND COMPRESSORS

MECAIR CSN RAINTIGHT ENCLOSURE CLEAN AIR SOLUTIONS PRODUCT LEAFLET

DIAPHRAGM VACUUM PUMPS AND COMPRESSORS

RELAY PRODUCT GUIDE CONTENTS

HAZARDOUS AREA DIFFERENTIAL CLOGGING INDICATOR DEH SERIES

RF Chip Inductors. Wire-Wound , 0603, 0805, 1008, Pulse Electronics - leading supplier of magnetics for consumer applications

Accurate, easy to use and reliable: Easy to use control panel. Clear, backlit LCD display:

DIAPHRAGM VACUUM PUMPS AND COMPRESSORS

GasBloc Multifunctional gas control Combined regulator and safety shut-off valves Electrically modulating GB-M(P) 055 D01

Old documentation - Only for your information! Product is not available any more!

Global Economic Briefing: Industrial Production

METEOR LSR36500 LIGHTING UNDERWATER POOL LIGHT. Operating Instructions

x act i Precision- Pressure Transmitter for Food Industry, Pharmacy and Biotechnology Stainless Steel Sensor

ENGLISH Datasheet IEC Miniature Thermocouple Connector Socket with Stainless Steel mounting bracket Types K, J, T, E, N, B & Copper (IEC Colour Code)

Models EXN and OLG. General Description. Features and Benefits. Pressurizer for Vertical Air Conditioners Increased Safety for Hazardous Locations

Proportional pressure regulators VPPE

ECP Series Explosionproof Enclosures for OEM Applications. Optimized design, extensive sizes, and fast lead times.

Meta-MEC Manual Motor Starters

G1/8 G1/8. Model 0 bar -0,1 bar -0,2 bar -0,3 bar -0,4 bar -0,5 bar -0,6 bar -0,7 bar -0,8 bar

ENGLISH. Datasheet L60 Thermocouple & Fine Wire Welder

IEC Thermocouple Extension Leads with Miniature or Standard Thermocouple Connectors - Available in types K, J, T & N

Dual Modular Safety Shutoff Valve with NEMA 4x Enclosure. DMV-D/604L Series DMV-DLE/604L Series

P9000 DESCRIPTION. For parts requiring RoHS compliance, please contact factory. P February /6

(TRCM) Wire Wound RF SMD Inductor

References 6 k thermal overload relays, adjustable from 0.11 to 16 A

OPERATOR ADAPTER APCITE

Old documentation - Only for your information! Product is not available anymore!

[Instruments for vacuum measurement, checking and adjustment] 3

1 Overview. Pressure Measurement Single-range transmitters for general applications. 1/22 Siemens FI US Edition

HUMOR 20 HUMOR 20. High-precision Humidity Calibrator. Water T, p1

FIS SNOWBOARD WORLD CUP 2015/16

Technical Data. General specifications. Rated operating distance s n 5 mm

Transcription:

DATASHEET IEC Inlet Filters FN 390 Versatile Filtered Power Entry Module Rated currents up to 10 A For one or two fuses Fuses Ø6.3 x 32 mm or Ø5 x 20 mm 2-pole rocker switch Voltage selector Optional earth line choke (E type) Approvals Performance indicators The FN 390 power entry module combines an IEC inlet, mains filter with single or dual-fuse holder, voltage selector and 2-pole rocker switch. Choosing FN 390 product line brings you the rapid availability of a standard filter associated with the necessary safety acceptances. Standard IEC connector filters are a practical solution helping you to pass EMI system approval in a short time. Multiple options designed to offer you the desired solution. Features and benefits Technical specifications Maximum continuous operating voltage Operating frequency Rated currents High potential test voltage 250 VAC, 50/60 Hz DC to 400 Hz 1 to 10 A @ 40 C max. P > PE 2000 VAC for 2 sec P > N 760 VAC for 2 sec Protection category IP 40 according to IEC 60529 Temperature range (operation and storage) -25 C to +85 C (25/85/21) Design corresponding to UL 1283, CSA 22.2 No. 8 1986, IEC/EN 60939 Flammability corresponding to MTBF @ 40 C/230 V (Mil-HB-217F) Voltage selector description Function Voltage marking Series Parallel Rocker switch description Function Electrical specifications Mechanical life Switch ratings USA (UL) and Canada (C-UL) Europe (ENEC) * Value in () relates to the inductive current charge: cos φ=0.65 UL 94V-2 or better 2,200,000 hours Series/parallel 110-120 V 220-240 V 2-pole, dark not illuminated Marking I - 0 Inrush current 51 A 6,000 on-off operations according to UL 1054, TV 5 10,000 on-off operations according to ENEC 50,000 cycles 10 A, 125 VAC; 10 A, 250 VAC; 1/3 HP 10 A (4 A), 250 VAC* High conducted attenuation performance, based on chokes with high saturation resistance and excellent thermal behavior Rear or front mounting Single or dual-fuse holder USA Ø6.3 x 32 mm or EU Ø5 x 20 mm fuses 2-pole rocker switch Voltage selector 110-120 V/220-240 V Custom-specific versions are available on request Typical applications Portable electrical and electronic equipment Consumer goods EDP and office equipment Single-phase power supplies, switch-mode power supplies Test and measurement equipment Typical electrical schematic

2 EMC/EMI Products Schaffner Group Datasheets 10 Dec 2018 Filter selection table Filter Rated current Leakage current* Inductance Capacitance Resistance Output Fuses** Weight @ 40 C (25 C) @ 230 VAC/50 Hz L1 L2 Cx Cx1 Cy R connections [A] [μa] [mh] [mh] [nf] [nf] [nf] [kω] [Qty] [g] FN 393-1-05-11 1 (1.2) 560 7.5 220 3.3 1000 05-11 1 200 FN 393-2.5-05-11 2.5 (3) 560 2 220 3.3 1000 05-11 1 200 FN 393-6-05-11 6 (7.2) 560 0.45 220 3.3 1000 05-11 1 200 FN 394-1-05-11 1 (1.2) 560 7.5 220 3.3 1000 05-11 2 200 FN 394-2.5-05-11 2.5 (3) 560 2 220 3.3 1000 05-11 2 200 FN 394-6-05-11 6 (7.2) 560 0.45 220 3.3 1000 05-11 2 200 FN 393 E-1-05-11 1 (1.2) 560 7.5 0.4 220 3.3 1000 05-11 1 205 FN 393 E-2.5-05-11 2.5 (3) 560 2 0.4 220 3.3 1000 05-11 1 205 FN 393 E-6-05-11 6 (7.2) 560 0.45 0.4 220 3.3 1000 05-11 1 205 FN 394 E-1-05-11 1 (1.2) 560 7.5 0.4 220 3.3 1000 05-11 2 205 FN 394 E-2.5-05-11 2.5 (3) 560 2 0.4 220 3.3 1000 05-11 2 205 FN 394 E-6-05-11 6 (7.2) 560 0.45 0.4 220 3.3 1000 05-11 2 205 FN 1393-1-05-11 1 (1.2) 797 16 220 100 4.7 470 05-11 1 210 FN 1393-2.5-05-11 2.5 (3) 797 8 220 100 4.7 470 05-11 1 210 FN 1393-6-05-11 6 (7.2) 797 2.5 220 100 4.7 470 05-11 1 210 FN 1393-10-05-11 10 (12) 797 0.6 220 100 4.7 470 05-11 1 210 FN 1394-1-05-11 1 (1.2) 797 16 220 100 4.7 470 05-11 2 210 FN 1394-2.5-05-11 2.5 (3) 797 8 220 100 4.7 470 05-11 2 210 FN 1394-6-05-11 6 (7.2) 797 2.5 220 100 4.7 470 05-11 2 210 FN 1394-10-05-11 10 (12) 797 0.6 220 100 4.7 470 05-11 2 210 * Maximum leakage under normal operating conditions. Note: if the neutral line is interrupted, worst case leakage could reach twice this level. ** Filters are delivered without fuse. Note: for medical versions please contact your local partner within Schaffner s global network. Product selector For example: FN 393-1-05-11, FN 394 E-2.5-05-11, FN 1394-10-05-11

3 EMC/EMI Products Schaffner Group Datasheets 10 Dec 2018 Typical filter attenuation Per CISPR 17; A=50 Ω/50 Ω sym; B=50 Ω/50 Ω asym; C=0.1 Ω/100 Ω sym; D=100 Ω/0.1 Ω sym FN 39x: 1 A types FN 39x: 2.5 A types FN 39x: 6 A types FN 139x: 1 A types FN 139x: 2.5 A types FN 139x: 6 and 10 A types Mechanical data 1 to 10 A types Panel cut out

4 EMC/EMI Products Schaffner Group Datasheets 10 Dec 2018 Dimensions 1 to 10 A Tolerances A 50 ±0.3 B 65 ±0.3 C 40 ±0.1 D 69.5 ±0.3 E 28 F 5.5 ±0.3 G 59.6 H Ø 3.3 I 15 J 7.5 M R 2.5 N 60.00 ±0.5 P 29.00 ±0.5 R M3 S 90 U 15 All dimensions in mm; 1 inch=25.4 mm Tolerances according: ISO 2768-m/EN 22768-m Please visit www.schaffner.com to find more details on filter connections.

5 EMC/EMI Products Schaffner Group Datasheets 10 Dec 2018 Headquarters, global innovation and development Sales and application centers Switzerland Schaffner Group Nordstrasse 11 4542 Luterbach T +41 32 681 66 26 info@schaffner.com To find your local partner within Schaffner s global network: www.schaffner.com 2018 Schaffner Group The content of this document has been carefully checked and understood. However, neither Schaffner nor its subsidiaries assume any liability whatsoever for any errors or inaccuracies of this document and the consequences thereof. Published specifications are subject to change without notice. Product suitability for any area of application must ultimately be determined by the customer. In all cases, products must never be operated outside their published specifications. Schaffner does not guarantee the availability of all published products. This disclaimer shall be governed by substantive Swiss law and resulting disputes shall be settled by the courts at the place of business of Schaffner Holding AG. Latest publications and a complete disclaimer can be downloaded from the Schaffner website. All trademarks recognized. China Schaffner EMC Ltd. Shanghai T20-3 C, No 565 Chuangye Road, Pudong district 201201 Shanghai T +86 21 3813 9500 cschina@schaffner.com www.schaffner.com.cn Finland Schaffner Oy Sauvonrinne 19 H 08500 Lohja T +358 50 468 7284 finlandsales@schaffner.com France Schaffner EMC S.A.S. 16-20 Rue Louis Rameau 95875 Bezons T +33 1 34 34 30 60 F +33 1 39 47 02 28 francesales@schaffner.com Germany Schaffner Deutschland GmbH Schoemperlenstrasse 12B 76185 Karlsruhe T +49 721 56910 F +49 721 569110 germanysales@schaffner.com India Schaffner India Pvt. Ltd REGUS WORLD TRADE CENTRE WTC, 22nd Floor Unit No 2238, Brigade Gateway Campus, 26/1, Dr. Rajkumar Road Malleshwaram (W) 560055 Bangalore T +91 80 67935355 indiasales@schaffner.com Italy Schaffner EMC S.r.l. Via Ticino, 30 20900 Monza (MB) T +39 039 21 41 070 italysales@schaffner.com Japan Schaffner EMC K.K. 1-32-12, Kamiuma, Setagaya-ku 7F Mitsui-seimei Sangenjaya Bldg. 154-0011 Tokyo T +81 3 5712 3650 F +81 3 5712 3651 japansales@schaffner.com www.schaffner.jp Singapore Schaffner EMC Pte Ltd. #05-09, Kg Ubi Ind. Estate 408705 Singapore T +65 6377 3283 F +65 6377 3281 singaporesales@schaffner.com Spain Schaffner EMC España Calle Caléndula 93, Miniparc III, Edificio E El Soto de Moraleja, Alcobendas 28109 Madrid T +34 917 912 900 F +34 917 912 901 spainsales@schaffner.com Sweden Schaffner EMC AB Tegeluddsvägen 76, 2tr 115 28 Stockholm T +46 8 5050 2425 swedensales@schaffner.com www.schaffner.com Switzerland Schaffner EMV AG Nordstrasse 11 4542 Luterbach T +41 32 681 66 26 switzerlandsales@schaffner.com Taiwan R.O.C. Schaffner EMV Ltd. 20 Floor-2, No 97, Section 1, XinTai 5th Road 22175 XiZhi District New Taipei City 22175 T +886 2 2697 5500 F +886 2 2697 5533 taiwansales@schaffner.com www.schaffner.com.tw Thailand Schaffner EMC Co. Ltd. Northern Region Industrial Estate 67 Moo 4 Tambon Ban Klang Amphur Muangg P.O. Box 14 51000 Lamphun T +66 53 58 11 04 F +66 53 58 10 19 thailandsales@schaffner.com United Kingdom Schaffner Ltd. 5 Ashville Way, Molly Millars Lane Wokingham RG41 2PL Berkshire T +44 118 9770070 F +44 118 9792969 uksales@schaffner.com USA Schaffner EMC Inc. 52 Mayfield Avenue 08837 Edison, New Jersey T +1 800 367 5566 T +1 732 225 9533 F +1 732 225 4789 usasales@schaffner.com www.schaffnerusa.com Schaffner North America 6722 Thirlane Road 24019 Roanoke, Virginia T +1 276 228 7943 F +1 276 228 7953

Schaffner North America 823 Fairview Road 24382 Wytheville, Virginia T +1 276 228 7943 F +1 276 228 7258 www.schaffnerusa.com/