GUMMIKOMPENSATOR GKF8000 / GKF8130

Similar documents
Materials : Galvanized steel flanges

Materials : Electro galvanized steel flanges

Size : Ends : Min Temperature : Max Temperature : Materials : Galvanized steel flanges

Materials : Dichromate zinc plated steel flanges

Materials : Dichromate zinc plated steel flanges or AISI 316

GUKO FDA. einfach. gut. beraten.

Materials : Stainless steel ASTM A351 CF8M

Size : Ends : Min Temperature : Max Temperature : Materials : Cast iron body

Materials : Carbon steel ASTM A216 WCB

Size : Ends : Min Temperature : Max Temperature : Materials : Cast iron body

DN 1/2" to 2" Female BSP + 0 C C Max Pressure : 16 Bars Specifications : Stainless steel removable filter Female / Female With draining valve

Unit 1, Fullerton Road Rotherham S60 1DJ. Tele: Fax:

Size : Ends : Min Temperature : Max Temperature : Materials : Cast iron EN GJL 250 body. Reinforced lug for DN200 :

Materials : Forged carbon steel A105N

Size : Connection Ends : Min Temperature : Max Temperature : Materials : Cast iron body

Materials : Forged carbon steel A105N

DN 3/8" to 4" Female BSP - 10 C C Max Pressure : 16 Bars up to DN 2 Specifications : Removable stainless steel filter Female / Female

Materials : Forged carbon steel A105N

pipe connectors. General description of pipe connectors Development/Design Purpose Versions

Materials : Forged carbon steel A350 LF2

DN 1/2" to 2 Female - Female BSP - 20 C C Max Pressure : 16 Bars Specifications : Rotating non rising stem Inside screw stem Full bore

STAINLESS STEEL LOW PRESSURE REDUCING VALVE LPRV ELITE

Serie 06-M6. Swing wafer check valve. made in. Application fields. Check valves E U R O P E WATER CONDITIONING INDUSTRY

Forged stainless steel ASTM A182 F316

Ref GAS WAFER BUTTERFLY VALVE. Model/Ref:

Series 42 Self-operated Regulators Differential Pressure Regulators with Type 2424/Type 2428 Actuator (closing) Type Type 42-28

AVP-F. p setting range (bar) Code No. 003H6200

Manguito Antivibration Oria

Differential pressure controller (PN 16) AVPL return mounting, adjustable setting

DN 1/2" to 2" Female / Female BSP - 5 C + 60 C Max Pressure : 5 Bars Specifications : Anti blow-out stem Double o ring NBR on stem Full bore

DN 1/4" to 3" Female BSP - 10 C C Max Pressure : 25 Bars ( up to DN 1 ) Specifications : Anti blow-out stem With PTFE packing Full bore

Materials : Brass body dezincification-resistant up to DN1 1/4

Differential Pressure Control Valve (DPCV)

STAD. Balancing valves DN (MD60, MD61, MD62)

Translation of the original Operating Instructions for HKS rubber compensators

Two-port valves, male threaded, PN25

Materials : Stainless steel ASTM A351 CF8M

Differential pressure and flow controller (PN 16) AVPQ - return mounting, adjustable setting

Calculation tables for thermal expansion.

DN 65 to 100 R.F. PN10 flanges + 5 C + 65 C Max Pressure : 10 Bars Specifications : Brass check valve Controlable With valves DN1/2

Fabric compensators. 9.0 Elastomer, rubber and metal compensators. Metal compensators

TA-FUSION-P. Combined control & balancing valves Pressure independent combined balancing and control valves with independent EQM characteristics

Engineering Data Sheet

2-Port Seat Valves with Flange, PN 16

Differential pressure controller (PN 25) AVP - return and flow mounting, adjustable setting

VALFONTA INSTRUCTIONS: OPERATION AND INSTALLATION PRESSURE REDUCING VALVE MODEL PRV44

STAD. Balancing valves DN 15-50

FITTINGS AND VALVES Düker Plunger Valve RKV Type 7015 Professional control of flow rates, reservoir levels and pressures Safe, hygienic and durable!

STAINLESS STEEL OVERFLOW VALVE TYPE 417

CAST IRON SAFETY VALVE TYPE 6301

Overview of types. T5-R B2/R B2 en v Subject to changes 1 / 4. k vs (Sequence 2)

STAD-D. Balancing valves Balancing valve for domestic water systems, DN Balancing valves

DIFFERENTIAL PRESSURE REGULATING VALVE zcon

2-Port Seat Valves with Flange, PN 16

Differential pressure controller (PN 16) AVPL - return mounting, adjustable setting

Safety Shut-Off Valve HON 720

Presetting Valve Type RA-N with Flange Connection

DN300 DN2000 C Plunger Valve

Rolled Rotary Ball Screw

Technote. Frese PVS - Dynamic Pressure and Flow Regulation Valve. Application. Features. Benefits.

TECHNICAL CATALOGUE PRESSURE REDUCING VALVES EUROPRESS

BUTTERFLY VALVES. Toll Free (877) - ICFLUID -2-

TECHNICAL CATALOGUE PRESSURE REDUCING VALVES EUROPRESS

STAG. Balancing valves Balancing valve with grooved ends DN

VPPL VARIABLE DISPLACEMENT AXIAL-PISTON PUMPS FOR INTERMEDIATE PRESSURE SERIES 10

STA. Double regulating valves DN 15-50

important information

Self-Aligning Cylindrical Roller Bearings. Plummer Block Housing. Series ACB, sealed on both sides. Series SLG01

STA. Double regulating valves DN 15-50

Materials : Brass body dezincification-resistant

Series 8500 Expansion Compensators. Catalog 674H

Gas Pressure Regulator HON 502

Mounting and Operating Instructions EB 3007 EN. Self-operated Pressure Regulators. Differential Pressure Regulators (opening) Type Type 42-25

2-port seat valves PN25 with externally threaded connections

Rp [ ] Sv min. [ ] C215QP-B 15 1/ C215QP-D 15 1/ C220QP-F 20 3/ [ ]

Seated valves (PN 16) VF 2 2-way valve, flange VF 3 3-way valve, flange

Pilot HON 625. Entwurf. Product information. serving the gas industry worldwide

Self-operated Regulators Accessories Differential Pressure and Flow Regulators

ATH 500 M. Pumping speed ATH 500 M. 3.1 Vacuum generation / Turbopumps / Magnetically levitated / ATH 500 M. Page 398 / Part 3.1

Si C132. Safety valves for pressure relief in accordance to PED, DIN/EN and ASME. Engineering GREAT Solutions

INSTALLATION & MAINTENANCE INSTRUCTIONS - ORIGINAL VERSION AVK KNIFE GATE VALVES

Seated valves (PN 6) VL 2 2-way valve, flange VL 3 3-way valve, flange

STA-F Description. STA-F Prefab insulation Measuring nipples

Pressure Reducing Valve DMV 750 set range: bar

Type overview. R B2 en-gb subject to changes 1

50Hz. water solutions. O SerieS DGO DRO

Radiator valves VDN1.. VEN1..

Installation, commissioning and servicing instructions

Torque Tube TB300 Digital Transmitters

627 Series Pressure Reducing Regulators

STAD-C. Balancing valves DN 15-50

Pressure Relief Valve DHV 718

Serie ECO 3T. Threaded end back flow preventer with controllable reduced pressure zone. made in. Application fields. Protection E U R O P E

Serie ECO 3F. Flanged back flow preventer with controllable reduced pressure zone. made in. Application fields. Protection

Material Handling Hose

TBV-CM. Combined control & balancing valves for small terminal units For modulating control

Low torque Metal seal type Rotary joint

Gas Pressure Regulator HON 300

Radiator valves VDN2.. VEN2.. VUN2..

Industry Guidelines POLYETHYLENE (PE) PIPES AND FITTINGS FOR COMPRESSED AIR ISSUE 6.8

Transcription:

GUMMIKOMPENSATOR GKF8000 / GKF8 Size : Ends : Min Temperature : Max Temperature : DN 32 to 600 Flanges PN10/16-10 C + 100 C for EPDM and + 80 C for NBR Max Pressure : 16 Bars up to DN 300 Specifications : Absorb vibrations and noises Linear and angular compansion Single sphere Materials : Galvanized steel flanges

SPECIFICATIONS : Absorb vibration, noises and expansion Linear and angular compansion Tube EPDM ( EPDM marking ) Galvanized steel flanges PN10/16 Expansion limiter ( option ) USE : Water distribution ( for EPDM types ) Oil, hydrocarbon, air ( for NBR types ) Min and max Temperature Ts : - 10 C to + 100 C for EPDM types Min and max Temperature Ts : - 10 C to + 80 C for NBR type Max Pressure Ps : 16 bars up to DN300 ( see graph ), 10 bars over PRESSURE / TEMPERATURE GRAPH (STEAM EXCLUDED ) GKF8000 / GKF8 DN 32 DN 300 : 8000 / 8 DN 32 DN 300

PRESSURE / TEMPERATURE GRAPH (STEAM EXCLUDED ) GKF8000 DN 350 DN 600 : 8000 DN 350 DN 600 PRESSURE / TEMPERATURE GRAPH (STEAM EXCLUDED ) GKF8000 PN16 DN 32-200 : 8000 PN16 DN 32 DN 200

RANGE : EPDM expansion joint with steel flanges PN10 from DN 32 to DN 600 EPDM expansion joint with steel flanges PN16 from DN 200 to DN 300 MATERIALS : Item Designation Materials 8000 8 1 Inner tube and cover EPDM 2 Reinforcement Nylon cord 3 Brace Hard steel 4 Flanges Galvanized steel

EXPANSION JOINT EPDM OR NBR PN10/16 SIZE ( in mm ) : Ref. DN 32 40 50 65 80 100 125 150 200 250 300 350 400 450 500 600 L 95 95 105 115 135 170 180 205 240 260 265 265 200 200 250 8000 Ø D 29 37 47 57 74 91 119 145 199 241 294 331 372 431 486 591 Ø D1 69 79 90 108 124 145 179 209 261 320 370 420 473 532 587 685 Weig. (Kg ) 2.79 3.59 4.23 4.74 6.27 6.47 9.4 12.75 17.73 23.27 29.4 41.3 46.85 55.18 65 74.5 Ref. DN 32 40 50 65 80 100 125 150 200 250 300 L 8 Ø D 29 36 48 63 72 92 123 144 199 254 295 Ø D1 69 78 89 108 123 145 180 209 259 322 370 Weight (Kg ) 2.74 2.98 4.24 4.98 5.72 6,94 9.18 10.96 15.3 20.24 23.46

FLANGES SIZE PN10 GKF8000 / GKF8 ( in mm ) : Ref. DN 40 50 65 80 100 125 150 200 250 300 Ø D 150 165 185 200 220 250 285 340 395 445 8000 8 Ø K 110 125 145 160 180 210 240 295 350 400 Nb x Ø L 4 x 19 4 x 19 4 x 19 8 x 19 8 x 19 8 x 19 8 x 23 8 x 23 12 x 23 12 x 23 b 14 15 15 17 17 19 19 20 22 22 Ref. DN 350 400 450 500 600 Ø D 505 565 615 670 780 8000 Ø K 460 515 565 620 725 Nb x Ø L 16 x 23 16 x 28 20 x 28 20 x 28 20 x 31 b 26 28 28 30 32

FLANGES SIZE PN16 GKF8000 PN16 ( in mm ) : Ref. DN 200 250 300 Ø D 340 405 460 8000 / PN16 Ø K 295 355 410 Nb x Ø L 12 x 23 12 x 28 12 x 28 b 22 24 24

MOVEMENTS ( in mm ) : DN 32 40 50 65 80 100 125 150 200 250 300 350 400 450 500 600 Compansion 8 8 8 12 12 18 18 18 20 22 24 25 25 20 20 20 Expansion 4 4 4 6 6 10 10 10 14 14 14 16 16 12 12 12 Lateral 8 8 8 10 10 12 12 12 18 18 18 18 18 18 18 18 Angular 15 15 15 15 15 15 15 15 15 15 15 15 15 15 15 15 STANDARDS : Fabrication according to ISO 9001 : 2008 DIRECTIVE 97/23/CE : Products excluded from directive ( article 1, 3.2 ) Flanges according to EN 1092-1 PN10/16

INSTALLATION INSTRUCTION : Expansion joint are designed for the absorption of previously specified movements under specific pressure and temperature conditions. So that the maximum service life is achieved, the following items must be observed during installation. Prior to fitment of the compensator it must be ensured that : The route of the pipeline is straight - The expansion tallies with that of the chosen compensator The expansion tallies with that of The chosen compensator The fixes points are dimensionned so that they can absorb the reaction forces and stiffness rate that arise during use. The pipeline is limited by fixed points The distance between compensator and bearing may be a maximum of 3 times the pipe diameter. Place only one compensator between 2 bearings. Each pipe elbow must be fixed by support, specially if compensator is mounted with limiters. Fixed bearings are necessary because compensator is submitted to expansion when it is under pressure. Expansion joint must not be painted and heat-insulated. It must be protected from bad weather and solar radiation. During assembly operation, make sure screws are oriented according to the graph out below : Please apply the following stages order : a) Fixed points for above pipeline b) Fixed points for down pipeline c) Compensator mounting Installation layout : L1 = 3 X DN L2 = according to weight and pipes types

INSTALLATION INSTRUCTION ( SUITE ) : Check that the compensator is not subjected to the weight of the pipeline. The installation lenght must agree with the installation gap. The compensator must never be twisted. It is recommended that specific characteristics be observed during maintenance : o The compensator must never be painted or recovered by heat insulation o The tightness of the bolts must be checked often. o The flanges must be perfectly cleared Use limiters : When the working pressure can exceed the following values : o Up to DN100 : 10 bars o From DN125 to DN250 : 9 bars o From DN300 to DN350 : 6 bars o From DN400 to DN600 : 3 bars o When there is some risk of high pressure (pump starting) or high temperature. NOTA : The life of compensator can vary because of working conditions (fluids, pressure, temperature), that is why it is necessary to check it regullary. WRONG INSTALLATION : Excessive Excessive Cutting too Torsion Important compansion Angular deviation compansion expansion important and angular deviation too important