NEW: CO2 incubator with sterilizable sensor

Similar documents
NEW: CO2 incubator with sterilizable sensor

CO2 incubator with additional process controls

CO2 incubator with additional process controls

CO2 incubator with additional process controls

CO2 incubator with additional process controls

CO2 incubator with additional process controls

Drying ovens FD series Drying ovens with forced convection Leistungsmerkmale/Ausstattung:

Thermo Scientific Heraeus BBD6220 CO 2 Incubators

Thermo Scientific Heraeus BBD6220 CO 2 Incubators

CO2 INCUBATOR CO2 INCUBATORS

The HumiSys. RH Generator. Operation. Applications. Designed, built, and supported by InstruQuest Inc.

Pneumatic high-pressure controller Model CPC7000

PERFORM Operating Document

973-SF 6 Analyzer. Precise and Stable SF 6 Gas Analyzer REFLECTING YOUR STANDARDS

PERFORM Operating Document

MICROBIOLOGICAL CO2 INCUBATORS. NuAire, Inc Fernbrook Lane Plymouth, MN U.S.A. nuaire.com

Pneumatic high-pressure controller Model CPC7000

NuAire, Inc Fernbrook Lane Plymouth, MN U.S.A

Datasheet: K-30 ASCII Sensor

Oxygen Flue Gas Analyzer BA 2000

Series Environmental Chambers

HumiSys HF High Flow RH Generator

Ruskinn Hypoxia and Anoxia Workstations. innovation in incubation

XMO2. Panametrics Smart Oxygen Analyzer. Applications. Features. bhge.com. An oxygen transmitter for use in:

...makes sense! Combined CO 2 /O 2 analyzers. Monitor your process in real-time: OUR CER. BlueSens.com

BUBBLER CONTROL SYSTEM

LT GasAnalyzer. LT GasAnalyzer Page 1 of 6

MANUAL KPS Pressure Control Valve

HUMOR 20. High-precision Humidity Calibrator HUMOR 20. Operation

ATM/GR. Electronic pressure switches CUSTOMER BENEFITS

BUBBLER CONTROL SYSTEM

OPERATOR S MANUAL Ar-Gone Weld Gas Analyzer

Sorensen DCS Series. 1 3 kw V A. General Purpose Systems Power Supply

Hand-held pressure calibrator with integrated pump Model CPH6600

We measure it. For gas and water installers. testo hpa. bar

SonoMeter 30 Energy Meters

EPP4 Pressure Regulator Basic G 1/4"

Additel 761 Automated Pressure Calibrators Selection Guide

Continuous Gas Analyzers, extractive

DF-550E PROCESS ANALYSERS APPLICATIONS FEATURES

Certified according to DIN EN ISO 9001 Technical Datasheet TRICOR Series Mass Flow Meters

CO2 Incubator. LCO-A Series

TEL/jlRE" Introduction. Display Features and Modes. Startup Procedure. Power-Up Procedure. Adjustment Modes

Additel 761 Automated Pressure Calibrators Selection Guide

Additel 761 Automated Pressure Calibrators

FAS-W. Features. Applications. Automatic condensation hygrometer

Precision pressure sensor Basic version Model CPT6020

OxyScan Graphic. Operating Instructions. UMS Micro-oxygen sensor 501. Microprocessor instrument

Flow VA 520. incl. temperature measurement. Intelligent solutions for ac- for compressed air and gases R 1/4 (DN 8) DN 15 R 3/4 (DN 20) DN 25

Flow VA 520. incl. temperature measurement. Intelligent solutions for ac- for compressed air and gases R 1/4 (DN 8) DN 15 R 3/4 (DN 20) DN 25

UsER manual for Watersens ph -REDOX

Plasma. Argon Production Helium Liquefaction Truck Loading Pure Gas Bottling

Columbus Instruments

KERN EG/EW Version /02

MEGAS 2.0. Gas analysis with direct C-Level Calculation and Bus-Connection. Data sheet

DM01. Please visit our website: Battery Powered Precision Digital Gauge. Stainless Steel Sensor. class 0.05

IDL01. Battery Powered Precision Digital Gauge for Leak Testing. Stainless Steel Sensor. class 0.05

HUMOR 20 HUMOR 20. High-precision Humidity Calibrator. Water T, p1

INFLUENCE OF MEASURING PROCESS AUTOMATION ON UNCERTAINTY OF MASS STANDARD AND WEIGHTS CALIBRATION.

Programmable pressure and temperature transmitters PTM/RS485

LT GasAnalyzer beyond standards

NGN Series nitrogen generator

with O 2 Controller Instruction Manual

FTC130 Transmitter. Operating Manual

Operating Instructions CO2 Incubator symphony 6.5 W

ETd 04. Battery Powered Precision Digital Gauge. Stainless Steel Sensor. Type: ETd 04. class 0.05

Programmable pressure and temperature transmitters PTM/RS485

Pressure transmitter PASCAL Ci4

Installation and Operation Manual

The M-Series Eletta Flow Meter High accuracy DP Flow Meter with multiple functions

Additel 761 Automated Pressure Calibrators

Oxymax H COS21. Technical Information. Sensor with long-term stability for frequent sterilization and autoclaving

Differential Pressure Transmiter

FLAMMABLE GAS SENSOR/TRANSMITTER

Optical Dissolved Oxygen Meter

Digital deadweight tester Model CPD8500

Mass Flow Controller (MFC) for Gases

Parametrable / Programmable Pressure Transmitter

Gas density monitor With integrated transmitter Model GDM-100-TI

C-Flow Coriolis Mass Flow Meters

Additel 780 Series Pressure Controller

Precision digital pressure gauge Model CPG1000

Instruction and Maintenance Manual

DM01. Battery Powered Precision Digital Gauge. Stainless Steel Sensor. class 0.05

STERILIZABLE DISSOLVED OXYGEN SENSORS

Oxidation Stability of Gasoline and Aviation Fuels

GasSense NDIR User Manual

Real-time gas analysis and software for the management of bioprocessing

This multi-functional device allows the determination of up to six quality parameters with only one measurement:

Customer Responsibilities. Important Customer Information Series Q-TOF LC/MS Systems Site Preparation Checklist

Model EXAxt AV550G. Averaging Oxygen Analyzer

AUTOMATIC HOSE TEST UNIT, TYPE SPU

The affordable consumption counter for compressed air and gases R 3 /4 (DN 20)

Analogue and Digital Mass Flow Meters and Controllers for Gases MASS-STREAM

Optical Dissolved Oxygen Meter

Accelerated Corrosion Test Chambers

Additel 761 Automated Pressure Calibrators

Digital dead-weight tester Model CPD8500

BAROMETER PRESSURE STANDARD PRESSURE CONTROLLER

Model 601CV. Mass Flow Controller. Product Features:

Transcription:

CB series - NEW 160 C2 incubators NEW: C2 incubator with sterilizable sensor The new CB series offers optimal growth conditions for cell cultures. The ANTI.PLENUM concept, the 180 C sterilization routine with the world's first sterilizable C2 sensor and other unique BINDER technologies meet the highest requirements for best possible cell growth and maximum sample safety in the premium class of BINDER C2 incubators. Advantages: ANTI.PLENUM DESIGN inner chamber concept "Less is More" Hot air sterilization at 180 C Sterilizable C2 sensor Unique BINDER technologies (patented air jacket system, controlled condensation, etc.) Areas of application:

Customer benefits Features Customer benefits Characteristics Inner chamber concept Autosterilization Heating Humidification C2 measurement Low risk of contamination Low running expenses Inner chamber quick and easy to clean Fully usable nominal volume Low risk of contamination Low costs for complete sterilization of the entire inner chamber ptimal cell growth throughout the inner chamber Low thermal degradation of the cell growth due to occasional door openings Constant osmotic pressure of the medium No risk of contamination due to damp areas ptimal cell growth due to stable ph value Sensor does not have to be removed for sterilization ANTI.PLENUM DESIGN "Less is More" with Minimized surface area Integrated shelf support system Eliminates all fixtures Fixed program controls 180 C hot air sterilization: Effective Standards-compliant C2 sensor is also sterilized Ventair Jacket System air jacket for: Accurate temperature control Homogeneous temperature distribution Fast recovery times Permadry double pan for: High humidity Defined recondensation Dry interior walls Sterilizable C2 humidity sensor in NIR technology for: Long-term stability Drift-free measurement Quick response

Performance characteristics VENTAIR air jacket system Temperature range: 7 C (13 F) above room temperature up to 60 C (140 F) BINDER controller with LCD color display for simultaneous display of all important parameters (temperature, % C2, % 2 concentration, humidity) and user-friendly push button/rotary knob Intuitive menu guidance Electronic chart recorder Variety of options for graphic display of process parameters Real-time clock Hot air sterilization at 180 (356 F) with sterilizable built-in C2 sensor Drift-free infrared C2 measurement system C2 introduction through patented gas mixing nozzle ANTI.PLENUM Design to avoid contamination of critical fixturespermadry System Permadry system, double pan humidification system with defined condensation site for condensate-free interior walls Seamless deep-drawn inner chamber made of stainless steel with round corners and integrated shelf support system Electronic error self-diagnostic system with visual and audible alarms, as well as potential-free contact for central monitoring Independent temperature safety device class 3.1 (DIN 12880) with visual and audible temperature alarm Tightly-fitted inner glass door made of safety glass Ethernet interface for communication software APT-CM DataControlSystem Three perforated shelves made of stainless steel Stackable units with new stacking adapter 2-point door lock BINDER test certificate

Specifications CB 160 Exterior dimensions Width (mm/inch) 680 / 26.8 Height (incl. feet) (mm/inch) 920 / 36.2 Depth (plus 54 mm (2.1 inch) for door handle and connection) (mm/inch) 715 / 28.2 Wall clearance side (mm / inch) 50 / 1.97 Wall clearance rear (mm / inch) 100 / 3.94 Number of doors (ea.) 1 Inner glass door(s) 1 Interior dimensions Width (mm/inch) 500 / 19.7 Height (mm/inch) 600 / 23.6 Depth (mm/inch) 500 / 19.7 Interior volume (l/cu.ft.) 150 / 5.4 Stainless steel shelf (number standard/max.) 3 / 6 Dimensions of shelf, width x depth (mm/inch) 495 x 444 / 19.5 x 17.5 Load per shelf (kg/lbs.) 10 / 22 Permitted total load (kg/lbs.) 30 / 66 Weight (empty) (kg/lbs.) 107 / 236 Temperature data Temperature range from 7 C (13 F) above ambient temperature to ( C/ F) 60 / 140 Temperature variation at 37 C (98.6 F) (± K) 0,3 Temperature fluctuation (± K) 0,1 Recovery time after door was opened for 30 sec. at 37 C (98.6 F) (min) 1) 4 Humidity data Humidity (% r.h.) 90-95 C2 data C2 range (Vol.-% C2) 0-20 Setting accuracy (Vol.-% C2) 0,1 Recovery time after doors was opened for 30 sec. at 5 vol. % (min.) 1) 5 C2 measurement IR Connection hose nozzle for C2 DN 6 for hose with internal diameter (mm) 6 / 0.24 2 data 2 range (Vol.-% 2) 0,2-95

Specifications Setting accuracy (Vol.-% 2) 0,1 Recovery time after door was opened for 30 sec. (min.) 1) at 1.0 vol. % 2 (min.) 12 at 5.0 vol. % 2 (min.) 12 2 measurement Gas connection hose nozzle for 2 / N2 DN 6 for hose with internal diameter (mm/inch) Zr2 6 / 0.24 Electrical data Voltage (± 10%) 50/60 Hz (V) 200-240 Voltage (± 10%) 60 Hz (V) 100-120 Nominal power (kw) 1,3 Energy consumption at 37 C (98.6 F) (W) 2) 100 1) up to 98 % of the set value 2) These values can be used for dimensioning air condition systems. All technical data is specified for unloaded units with standard equipment at an ambient temperature of 22 ± 3 C / 71.6 ±5.4 F and a power supply voltage fluctuation of ±10. The temperature data is determined in accordance to BINDER factory standard and DIN 12880, observing the recommended wall clearances of 10 % of the height, width and depth of the inner chamber. All indications are average values, typical for units produced in series. We reserve the right to change technical specifications at any time.

ptions Gas-tight, divided inner glass door For stable climate conditions in the broad chamber. Minimal loss of humidity, heat, and C2 when loading. Ensures short recovery times. 2 control For hyper- or hypoxic culture conditions. The 2 or N2 gas supply can be controlled using an additional control loop as needed. A zirconium oxide sensor (Zr2) is used for the measurement. BINDER Gas Supply Service The external tank changer makes automatic changeover to a second tank possible when the first tank is empty. It has audible and visual alarms and is equipped with a zero-voltage alarm output for external notification systems. It can be used with a maximum of two C2 incubators and is suitable for C2, 2 and N2 tanks. Stacking adapter Used for stacking of two CB incubators which are thermally isolated from each other. The incubators can thus be sterilized with hot air independent of each other. Available as stacking adapters, stacking frames or base frames.

ptions CB 160 Silicone access port on both sides closable with two silicone lids 30 mm (1.18 inch), left side Silicone access port on both sidsilicone access port on both sides closable with two silicone lids 30 mm (1.18 inch), right sidees closable with two Silicone access port on both sides closable with two silicone lids 30 mm (1.18 inch), back Gastank connection kit for C2, consisting of a gastank pressure regulator, max. pressure 10 bar, with connection parts, and a (5 m / 16.4 ft.) hose Gastank connection kit for 2, consisting of a gastank pressure regulator, max. pressure 10 bar, with connection parts, and a (5 m / 16.4 ft.) hose Gastank connection kit for N2, consisting of a gastank pressure regulator, max. pressure 10 bar, with connection parts, and a (5 m / 16.4 ft.) hose BINDER Gas Supply Service, external gas tank changer for connection of 2 gastanks, either C2 or N2, with audible and visible alarm and zero-voltage alarm output Additional RS 422 to USB and Ethernet 4-20 ma analog output for temperature and C2 measurements (e.g. chart recorder connection), with 6-pin DIN socket (output not adjustable) Interior power socket with N/FF switch and LEM connector (maximum power rating 230 V, 1N, 50 / 60 Hz) Factory calibration certificate for temperature and C2. Temperature measurement in center / C2 measurement performed using analyzed test gas at (37 C / 98.6 F) and 5 % C2 Factory calibration certificate for the 2 control option. 2 measurement performed using analyzed test gas at 1 % 2 Temperature measurement acc. to DIN 12880 (27 measuring points) at 37 C (98.6 F) or at specified temperature with measuring protocol and certificate Manual for cell culture technology Primary Human Cell Culture Current feedthrough (8-pin) for low voltage with Shelf, perforated, stainless steel Divided shelf, stainless steel for divided gas-tight inner glass door Base on castors Stacking frame vibration-free, on castors with stop brake, for direct and safe stacking of two CB 160 with wedge equipment Stacking adapter for thermal decoupled stacking of two CB 160 C2 incubators Stacking adapter C / CB for direct thermal decoupled stacking of a CB 160 / C 150 combination CELLRLL Set. Modular and expandable roller bottle system for cell cultivation, for 4 roller bottles