Operating Manual * * Pressure Transmitter. Table of Content. 1 Safety Guidelines. 1.3 Risks due to Non-Observance of Safety Instructions

Similar documents
* * Data Sheet and Operating Manual. Digital manometer ME01 ## # 87 # HL S#### Dust explosion protection Zone 22.

* * Operating manual ME12... R/S. Remotely configurable digital pressure transducer for use in explosive areas

Instruction Manual Contact Pressure Vacuum Gauge

Instruction Manual Differential Pressure Transmitter

Instruction Manual Contact Pressure Gauge

Instruction Manual Differential Pressure Transmitter

Instruction Manual Differential Pressure Gauge

Differenz-Drucktransmitter Differential pressure transmitter Transmetteur de pression différentielle bar

OPTIBAR P 1010 C Technical Datasheet

Electronic relative and differential pressure switch type 616

2/2-Way Solenoid Control Valve

Type Operating Instructions. 2/2-way solenoid valve 2/2-Wege Magnetventil Electrovanne 2/2 voies.

Installation and Maintenance Instruction Manual

ATM.ECO - Analog Pressure Transmitter

ATM.1ST. Pressure transmitters CUSTOMER BENEFITS

Pressure Transmitters 36 F-27839

SPD310/SPD360 Air Differential

Electropneumatic Positioner and Pneumatic Positioner Type 3760 JIS

Relative and differential pressure transmitter type 692

SITRANS P measuring instruments for pressure

Programmable pressure and temperature transmitters PTM/RS485

Electropneumatic Positioner and Pneumatic Positioner Type 3760 JIS

Measurement accessories METPOINT OCV for the measurement in systems up to 40 bar

Pressure Switches Application Guideline

Operating Manual. Diaphragm Seals Models , 107, , 207,

Programmable pressure and temperature transmitters PTM/RS485

Precision pressure sensor Basic version Model CPT6020

KTE6000 / KTU6000 Series OEM pressure transmitters for industrial media

* * Operating manual. DE49 ## A BA_EN_DE49_A Rev. ST4-C 01/18. Digital differential pressure transmitter with external sensor

SITRANS. Pressure transmitter SITRANS P, Z series for gauge and absolute pressure. Introduction. Safety instructions 2.

3-port seat valves with externally threaded connection, PN 16

Installation and Maintenance Instructions for F5509/F6509 Differential Pressure Gauges

2 Overview. SITRANS P measuring instruments for pressure. Transmitters for gage and absolute pressure. Z series for gage pressure

ATM - Analog Pressure Transmitter

Supplementary Installation and Operating Instructions. Variable Area Flow Meters SGK-1 Ex SGK-2 Ex SGK-3 Ex. Category: II 2G Ex IIC II 3G Ex IIC

Parametrable / Programmable Pressure Transmitter

Installation and Maintenance Instruction Manual

VS18/26 with PROFINET and EtherNet/IP Interface. ATEX Installation Instructions

High-performance submersible pressure transmitter For level measurement Model LH-10

Pilot HON 625. Entwurf. Product information. serving the gas industry worldwide

Pressure Transmitter P41

Pressure Measurement. Transmitters for basic requirements SITRANS P Z for gauge pressure. 2/4 Siemens FI Overview

Pressure transmitter PASCAL Ci4

ATM/GR. Electronic pressure switches CUSTOMER BENEFITS

Operating Instructions for Intrinsically Safe Pressure Transmitters Series DMG/******** for Hazardous Application in Coal Mining Industry

OPERATING INSTRUCTIONS MANUAL FOR QACV PNEUMATIC DOSING PUMP

ATM.ECO/IS - Analog Transmitter with Temperature compensation

Installation and Maintenance Instruction Manual

ATM/Ex - Intrinsically Safe Analog Pressure Transmitter - ATEX / IECEx Certified

IDL01. Battery Powered Precision Digital Gauge for Leak Testing. Stainless Steel Sensor. class 0.05

Operating and maintenance manual Filter and reducing station Series / 1.0

2-Port Seat Valves with Flange, PN 16

Installation and Operating Instructions Bypass Flow Meter DST

How to specify a product. Process Sensors and Mechanical Instruments

Mass Flow Controller (MFC) for Gases

ATM/Ex - Analog Pressure Transmitter

Product Catalogue. P-SERIES Pressure Gauges

DM01. Battery Powered Precision Digital Gauge. Stainless Steel Sensor. class 0.05

Pressure transmitters EMP 2

Pressure Measurement Single-range transmitters for general applications

Instruction Manual BA90 Precision Barometer

Mounting instructions. Strain transducer SLB-700A. B 26.SLB700A.10 e

GAS FUEL VALVE FORM AGV5 OM 8-03

2-Port Seat Valves with Flange, PN 16

2/2-Way Proportional Valve (motor-driven)

PULSAR 5000 SERIES OPERATING & INSTALLATION INSTRUCTIONS SERIES 5000 PLEASE READ CAREFULLY BEFORE INSTALLING

Mounting and operating instructions EB 2530 EN. Self-operated Pressure Regulator. Pressure Reducing Valve Type M 44-2

Pressure Measurement Single-range transmitters for general applications

Type N-10, N-11 Hazardous Area Non-incendive Transmitters

Instruction Manual EMA 84 Digital Pressure Gauge

Mounting and Operating Instructions EB 3007 EN. Self-operated Pressure Regulators. Differential Pressure Regulators (opening) Type Type 42-25

ATM.1ST/Ex - High Precision Transmitter

ETd 04. Battery Powered Precision Digital Gauge. Stainless Steel Sensor. Type: ETd 04. class 0.05

GI Series Diaphragm Pressure Gauge Guard

Type 3709 Pneumatic Lock-up Valve. Translation of original instructions. Mounting and Operating Instructions EB 8391 EN

Mass Flow Controller (MFC) for Gases

JUMO dtrans p30 Pressure Transmitter

Rocker valve. Type Operating Instructions. Bedienungsanleitung Manuel d utilisation

Type Pressure Regulator. for increased air capacity. Fig. 1: Type Pressure Regulator. Mounting and Operating Instructions EB EN

High-performance submersible pressure transmitter For level measurement Model LH-20

QPL... Pressure Switches. Siemens Building Technologies HVAC Products

High-performance submersible pressure transmitter For level measurement Model LH-10

Mounting and Operating Instructions EB 3017 EN. Self-operated Regulators

1 Overview. Pressure Measurement Transmitters for basic requirements. 1/16 Siemens FI SITRANS P220 for gauge pressure

DMK 458. Pressure Transmitter for Marine and Offshore. Ceramic Sensor. accuracy according to IEC 60770: standard: 0.25 % FSO option: 0.

P499 Heavy Duty Pressure Transducer

Type BBS-03, BBS-05, BBS-06, BBS-25

DM01. Please visit our website: Battery Powered Precision Digital Gauge. Stainless Steel Sensor. class 0.05

Manual Power relay SR853

3G Operating instructions. Digital Purge Gas Valve 3G Type: Document no.: D0001 Version: 01. July 2011/Rev.

Test pumps. Pressure sources. Good reasons for proper and reliable calibration

Type Operating Instructions. Bedienungsanleitung Manuel d utilisation

Proportional Pressure-Relief Cartridge Valve, Size 2...4

Self-operated Pressure Regulators for special applications

Pressure Measurement Single-range transmitters for general applications

GEMS SENSORS & CONTROLS

Electropneumatic Positioner Type 4763 Pneumatic Positioner Type 4765

Inverse Proportional Pressure-Relief Cart., Size 2 4

High-performance submersible pressure transmitter For level measurement in hazardous areas Model LH-20

Installation, operating and maintenance Instructions for Seemag bypass level indicator

Transcription:

*09005184* BA_EN_ME11 Rev.B 09/15 *09005184* d e v e l o p i n g s o l u t i o n s ME11 Operating Manual Pressure Transmitter Table of Content 1 Safety Guidelines 2 Application Purpose 3 Description of the product and functional description 4 Installation and Assembly 5 Commissioning 6 Maintenance and Repeat Tests 7 Transport 8 Service 9 Accessories 10 Disposal 11 Technical data 12 Dimensional drawings 13 Order Codes 14 Declaration of conformity 1 Safety Guidelines 1.1 Generalities This operating manual contains instructions fundamental to the installation, operation and maintenance of the instrument that must be observed unconditionally. It must be read by the assembler, operator and the specialised personnel in charge of the instrument before it is installed and put into operation. This operating manual must be kept close by where it is easily accessible to the responsible specialised personnel. The subsequent sections about general safety instructions 1.2-1.7 and the following special instructions about use through to disposal 2-10 contain important safety information, non-observance of which can endanger persons, animals, the environment and physical objects. 1.2 Personnel Qualification Staff assigned to assembly, operating, maintenance and inspection tasks shall be adequately qualified for this work and must be sufficiently instructed and trained to meet the requirements of assembly, operating, maintenance and inspection work. 1.3 Risks due to Non-Observance of Safety Instructions Non-observance of these safety instructions, the intended use of the instrument or the limit values given in the technical specifications can be hazardous or cause harm to persons, the environment or the system itself. The manufacturer will not be liable for damage claims should this happen. 1.4 Safety Instructions for the Operating Company and the Operator The safety instructions governing correct operation of the instrument must be observed. The operating company must make them available to the installation, maintenance, inspection and operating personnel. Dangers arising from electrical components, energy discharged by the medium, escaping medium and incorrect installation of the instrument must be eliminated. For more information, please see the applicable national and international regulations. In Germany these are the DIN EN, UVV regulations, specific industrial guidelines such as DVGW, Ex, GL, etc., the VDE- regulations and the regulations of the local energy supply companies.

1.5 Unauthorised Modification Modifications of or other technical alterations to the instrument by the customer are not permitted. This also applies to replacement parts. Any modifications / alterations required must be carried out by the manufacturer only. 3 Description of the product and functional description 3.1 Function Diagram 1.6 Inadmissible Modes of Operation The operational safety of this device can only be guaranteed if it is used as intended. The device model must be suitable for the medium used in the system. The limit values given in the technical data may not be exceeded. 1.7 Safe working practices for maintenance and installation work The safety instructions given in this operating manual, any nationally applicable regulations on accident prevention and any of the operating company's internal work, operating and safety guidelines must be observed. The operating company is responsible for ensuring that all required maintenance, inspection and installation work is carried out by qualified specialized personnel. 1.8 Pictogram explanation WARNING! indicates a potentially dangerous situation, non-observance of which could endanger persons, animals, the environment or objects. INFORMATION! highlights important information efficient and smooth operation. TIP! indicates recommendations that are not specifically necessary in certain situations but which could be useful. 2 Application Purpose The pressure transmitter ME11 is used to measure over-pressure and under-pressure. The device may only be used for the purpose stipulated by the manufacturer. If there is dirty or aggressive media in the system, or if this is to be expected, the device must be modified in terms of those parts that come into contact with the media. Please talk to the manufacturer first before placing the order. 1 Ceramic membrane 2 DMS bridge 3 Transformer electronics 4 Analogue output 3.2 Design and mode of operation The measuring pressure acts on a ceramic membrane that deforms when under pressure. There is a DMS bridge attached to the ceramic membrane. When the ceramic deforms, the output signal of the DMS bridge changes. The electronics integrated into the device convert the bridge signals into electrical unit signals 4...20 ma or 0 10 V DC um. 4 Installation and Assembly The device is set ex-works for vertical installation; however any installation position is possible. To guarantee safe working conditions during installation and maintenance, suitable stop valves must be fitted in the system. Using recommended accessories such as a manometer stop valve MZ 5 / MZ 6 etc., the device can: be depressurized or taken out of operation be disconnected from the power supply within the applicable system for repairs or inspections. 4.1 Process connection By authorized and qualified specialized personnel only. Only for designated mechanical process connections. For the model, see the order code on the instrument's type plate. Release the cables before connecting the device. Do not mount the device against existing water columns, and secure suitably against pressure surges. Use only with media suitable for operation. 2 8 Page

Maximum pressures must be observed. Check that the pressure connections do not leak before commissioning. 4.2 Measuring lines that need to be connected The following points need to be observed when connecting the pressure line: To ensure there is no influence on the measured values, severe bends and coils in the wire shold be avoided. To prevent deposits, there should be a continuous incline or drop of at least 8%. When measuring steam pressure, a water bagforming loop must be provided due to the temperature. (e.g.: accessories: MZ10/MZ11) The transmitter must be positioned below the measuring point for liquid measurements. Vent the pressure line before commissioning. The transmitter must be positioned above the measuring point for gas measurements. 4.3 Pressure surge absorption If there are pulsating pressure surges on the system side, this may impact on the function of the device. We recommend installing a damping element in the pressure connection lines as a protective measure. 4.3.1 Capillary throttle coils MZ40 HEX-AF27 HEX-AF27 4.4 Electronic connection By authorized and qualified specialized personnel only. The electrical connection of the device shall be performed according to relevant VDE and local electricity board regulations. Disconnect the system from the mains before connecting the device. Add a fuse adapted to the energy requirements. 4.4.1 2-wire connection Transmitter 4.4.2 Three-wire connection +Outp. Transmitter +U b / +Sig -U b / -Sig +U b -U b / -Sig +Sig Output signal Output signal +U b Supply 4.4.3 Standardised plug DIN EN 175 301-803-A -U b +U b -U b Supply Manometer connection 4.3.2 Configurable damping throttle MZ41 In operating mode, the damping throttle must be set so that the output signal follows the pressure changes with a delay. HEX-AF27 Table 1: 2-wire connection 4...20 ma Pin Signal name Cable colour 1 Supply/output +U b +Sig red 2 Supply/output -U b -Sig blue 3 n.c. 4 n.c. Table 2: 3-wire connection 0...10 V Pin Signal name Cable colour 1 Delivery +Sig black 2 Supply/output -U b -Sig blue 3 Supply +U b red 4 n.c. 3 8 Page

4.4.4 M12 plug connection Table 3: 2-wire connection 4...20 ma Pin Signal name Cable colour A Coding 1 Supply +U b +Sig brown 2 n.c. 3 Supply/output -U b -Sig blue 4 n.c. Table 4: 3-wire connection 0...10 V Pin Signal name Cable colour A Coding 1 Supply +U b brown 2 n.c. 3 Supply/output -U b -Sig blue 4 Delivery +Sig black 5 Commissioning All electrical supply, operating and measuring lines and the pressure connections must have been correctly installed before commissioning. All supply lines are arranged so that there are no mechanical forces acting on the device. If liquid measuring media are used the pressure connection lines must be deaerated, as liquid columns of different heights in the pipes can cause measuring errors. The instrument must be protected against frost if water is used as a medium. Appropriate shutoff valves must be provided to ensure safety during installation, maintenance and inspection. 6 Maintenance and Repeat Tests The instrument is maintenance-free. We recommend the following regular inspection to guarantee reliable operation and a long service life: Check the function in combination with downstream components. Check the leak-tightness of the pressure connection lines. Check the electrical connections. The exact test cycles need to be adapted to the operating and environmental conditions. In combination with other devices, the operating instructions for the other devices also need to be observed. 7 Transport The measuring device must be protected against impacts. It should be transported in the original packaging or a suitable transport container. 8 Service Warning All damaged or faulty devices must be sent directly to our repair department. Please coordinate all shipments with our sales department. Process media residues in and on dismantled devices can be a hazard to people, animals and the environment. Take adequate preventive measures. If required, the devices must be cleaned thoroughly. Return the device in the original packaging or a suitable transport container. 9 Accessories Please refer to data sheet MZ for accessories for the pressure transmitter ME11. 10 Disposal Incorrect disposal may pose a risk to the environment. Please help to protect the environment by always disposing of the work pieces and packaging materials in compliance with the valid national waste and recycling guidelines or reuse them. 4 8 Page

3 5 8 12 20 32 50 80 5 8 12 20 32 50 80 120 200-1 - 0-1 - 0.6-1 - 1.5-1 - 3-1 - 5-1 - 9-1 - 15-1 - 24 0-1.6 0-2.5 0-4 0-6 0-10 0-16 0-25 0-40 0-60 11 Technical data Measuring ranges (bar) Overpressure-proof Linearity Hysteresis General points < 1 % FS < 0.5 % FS Admissible ambient temperature 0 60 C Permissible medium temperature 0 85 C Pressure connection Electrical connection See order code Standardised plug acc. to DIN EN 175301-803-A M12 plug connection Type of protection IP 65 as per DIN EN 60 529 Material: parts with contact to the medium Chrome-Nickel-Steel 1.4305, ceramics: Al 2O 3, seal: see order code Material: Casing Chromium nickel steel 1.4305 Electrical data Electrical connection type 2-wire Three-wire Rated Voltage 24 V DC 24 V AC/DC Allowed operating voltage U b 6...30 V DC 15...30 V AC/DC Output signal 4-20 ma 0-10 V DC Apparent ohmic resistance (U b-6 V) / 0,02 A 5 k from 15 VDC 2 k from 20 VDC Current/voltage limit ca. 26 ma approx. 10.5 V DC Temperature drift, zero-point 0.07 % FS/K 0.07 % FS/K Temperature drift, measuring range 0.05 % FS/K 0.05 % FS/K 5 8 Page

12 Dimensional drawings (all dimensions in mm unless otherwise specified) Elbow plug connector in compliance with DIN 43650-A M16 x1.5 HEX-AF27 6 8 Page

13 Order Codes Pressure Transmitter ME11 M 0 Measuring ranges 0 1,6 bar... > 0 3 0 2,5 bar... > 0 4 0 4 bar... > 0 5 0 6 bar... > 0 6 0 10 bar... > 0 7 0 16 bar... > 0 8 0 25 bar... > 0 9 0 40 bar... > 1 0 0 60 bar... > 1 1-1 0 bar... > 3 1-1 0.6 bar... > 3 2-1 1.5 bar... > 3 3-1 3 bar... > 3 4-1 5 bar... > 3 5-1 9 bar... > 3 6-1 15 bar... > 3 7-1 24 bar... > 3 8 0 60 kpa... > F 1 0 100 kpa... > F 2 0 160 kpa... > F 3 0 250 kpa... > F 4 0... 400 kpa... > F 5 0 600 kpa... > F 6 0 1000 kpa... > F 7 0... 1600 kpa... > F 8 0... 2500 kpa... > G 1 0... 4000 kpa... > G 2 0... 6000 kpa... > G 3 0 30 PSI... > H 5 0 60 PSI... > H 6 0 100 PSI... > H 7 0 160 PSI... > H 9 0 250 PSI... > Q 1 0 500 PSI... > P 9-30 Inch Hg vac + 15 PSI... > S 2-30 Inch Hg vac +100 PSI... > S 5 Measuring accuracy Characteristic curve deviation gauge pressure 1.0... > M Pressure connection Connecting port with outer thread G ¼ B, 1.4305... > 8 5 Connecting port with outer thread G ½ B, 1.4305... > 8 7 Connecting port with outer thread ¼ -18 NPT EXT, 1.4305... > 8 8 Connection for the Schrader - screw connection... > S 1 Electrical output signal 4 20 ma... (only 2-wire)... > B 0 10 V DC... (only 3-wire)... > C Electrical connection Plug 4-pin, standardised plug DIN EN 175 301-803-A... > H M12 plug connector... > C Operating voltage 24 V DC... (only 2-wire)... > 9 24 V AC/DC... (only 3-wire)... > L Casing IP65... > 0 IP65, cast version... > V Media-Contact Seal FKM (standard)... > V CR (Chloroprene Rubber)... > C EPDM (Ethylene propylene diene rubber)... > E H-NBR (Hydrogenated Acrylonitrile Butadiene Rubber) can be used between -25 C and +100 C... > H Measuring System / Design Standard... > 0 System for measuring O 2 (only with FKM seal)... > 3 Silicon-free version A 7 8 Page

14 Declaration of conformity Technische Änderungen vorbehalten Subject to change without notice Changements techniques sous réserve Fischer Mess- und Regeltechnik GmbH Bielefelder Str. 37a D-32107 Bad Salzuflen Tel. +49 5222 9740 Fax +49 5222 7170 email: info@fischermesstechnik.de www.fischermesstechnik.de