FVA Trogflux variable area flowmeter. Operating Instructions. MECON GmbH 05/2013 OI_FVA_Trogflux_EN

Similar documents
FVA Tubux M30 Variable Area Flowmeter. Operating Instructions. MECON GmbH 07/2013 OI_FVA_Tubux_M30_EN

GA24 Technical Datasheet

GA24. GA24 Handbook. Variable-area flowmeter. KROHNE 02/ MA GA24 R01 en

DK48 - DK800. Quick Start. Variable area flowmeter

Variable area flowmeter F VA 250

OPTIBAR P 1010 C Technical Datasheet

Installation and Operating Instructions Bypass Flow Meter DST

Magnetic level switch type MR783 Instruction Manual

SITRANS P measuring instruments for pressure

Glass tube flowmeters Series 2000

Level transmitter LT 100

DK46 - DK800 Supplementary instructions

Glass tube flowmeters Series 2000 Variable area flowmeter for low flows of liquids and gases

VA40 - VA45 Technical Datasheet

KOBOLD KSM FLOWMETER. User Instructions

2 Overview. SITRANS P measuring instruments for pressure. Transmitters for gage and absolute pressure. Z series for gage pressure

SITRANS F I Gardex. Flowmeter. SITRANS F I Intra/Prima. Flap Flowmeter. Contents. English. General 1. SITRANS F I Gardex 2. SITRANS F I Intra/Prima 3

Measurement accessories METPOINT OCV for the measurement in systems up to 40 bar

OFFICINE OROBICHE S.p.A. 1/9

1 Overview. Pressure Measurement Transmitters for basic requirements. 1/16 Siemens FI SITRANS P220 for gauge pressure

KDV HIGH ACCURACY GLASS TUBE ROTAMETER

GILMONT ACCUCAL FLOWMETERS

Pressure Measurement. Transmitters for basic requirements SITRANS P Z for gauge pressure. 2/4 Siemens FI Overview

* * Data Sheet and Operating Manual. Digital manometer ME01 ## # 87 # HL S#### Dust explosion protection Zone 22.

Operating instructions for variable area flow meter with needle valve. Model: UVR/UTR

Measurement of Low GAS & Liquid Flows

Monitoring device NTS 30

Purgemaster Series 10A6100 SNAP-IN. Instruction Bulletin Replaceable Parts List. D184B003U35 Rev. 01 /

Variable Area Flow Meters. VS Series

Installation, operating and maintenance Instructions for Seemag bypass level indicator

1 Overview. Pressure Measurement Single-range transmitters for general applications. 1/16 Siemens FI US Edition

Instruction Manual Differential Pressure Transmitter

Pressure Measurement Single-range transmitters for general applications

Instruction Manual Contact Pressure Vacuum Gauge

Miniature flowmeters DK 46, DKR 46 DK 47, DK 48, DK 800

Liquid level instruments BM 24 /BM 51

KDV HIGH ACCURACY GLASS TUBE ROTAMETER

SITRANS. Pressure transmitter SITRANS P, Z series for gauge and absolute pressure. Introduction. Safety instructions 2.

Electropneumatic Positioner Type 4763 Pneumatic Positioner Type 4765

Mass Flow Controller (MFC) for Gases

Liquid level switch BM 34

2/2- and 3/2-way Rocker Solenoid Valve - bistable (impulse) version

Safety. Operating instructions Solenoid valve for gas VG 6 VG 15/10 DANGER. Contents WARNING CAUTION. Changes to edition 09.14

Solenoid valves VZWF, force pilot operated

Type 3709 Pneumatic Lock-up Valve. Translation of original instructions. Mounting and Operating Instructions EB 8391 EN

Supplementary Installation and Operating Instructions. Variable Area Flow Meters SGK-1 Ex SGK-2 Ex SGK-3 Ex. Category: II 2G Ex IIC II 3G Ex IIC

PRAHER PLC-MP AQUASTAR MANAUL 2009

Mass Flow Meter (MFM) for Gases

Siphon vessel / Priming aid

Instruction Manual Differential Pressure Transmitter

Pneumatic pressure switch 20DD

Instruction Manual AD 1000 / BA 1000 Absolute Pressure Sensor

CAST IRON SAFETY VALVE TYPE 6301

Electropneumatic Positioner and Pneumatic Positioner Type 3760 JIS

TRZ 03-K Volumeter. Proven Technology. Superior Performance. TRZ 03-K Volumeter is a Turbine Gas Flowmeter for Secondary Gas Metering.

Type BBS-03, BBS-05, BBS-06, BBS-25

Flowmeter. Original operating manual DFM

Mounting and Operating Instructions EB 3007 EN. Self-operated Pressure Regulators. Differential Pressure Regulators (opening) Type Type 42-25

Mass Flow Controller (MFC) for Gases

Type 4708 Supply Pressure Regulator

Mounting and Operating Instructions EB 3017 EN. Self-operated Regulators

MV-01. Features. 2/2-way Solenoid Valve for Fluids. Description: Application:

SPD310/SPD360 Air Differential

Air Sensor. FCS Ex. Manual. AQ Elteknik AB

Pressure Measurement Single-range transmitters for general applications

C-Flow Coriolis Mass Flow Meters

Bourdon tube pressure gauge for diaphragm seals

GI Series Diaphragm Pressure Gauge Guard

CVS10 Sanitary Check Valves

Electropneumatic Positioner and Pneumatic Positioner Type 3760 JIS

MASS-STREAM TM Instruction Manual. D-6200 Analog Mass Flow Meters / Controllers

T EK-SUB 4800C 19 mm Submersible Level Transmitter

Gas Pressure Regulator HON 300

Contents. 1. General information BROEN BALLOMAX Steel Ball Valves Approvals Quality Management...2

Mechanical Pressure Switches for overpressure, vacuum pressure and differential pressure

VALFONTA INSTRUCTIONS: OPERATION AND INSTALLATION PRESSURE REDUCING VALVE MODEL PRV44

Operating instructions Safety Rope Emergency Stop Switches ZB0052 / ZB0053 ZB0072 / ZB0073

Air Purge Unit. Series: LSP-compact Type: EJG 2-2. (Controlled with DigiFlow 515) Installation & Operation Manual 11/2014

Air Sensor. SAC Ex. Manual ATEX. AQ Elteknik AB

Operating instructions - Translation of the original -

ELADOS EDP L Diaphragm Metering Pump Type

Operating instructions - Translation of the original -

HAYWARD FLOW CONTROL Series PBV Back Pressure Valve and Series RPV Pressure Relief Valve INSTALLATION, OPERATION, AND MAINTENANCE INSTRUCTIONS

PSG 901. Pressure Switch for Gas. elektrogas.com EE141-07/12

P900. P900, Datenblatt Seite 1 DESCRIPTION

G type DUCTED EXHAUST SAFETY VALVE 2871 AND 288X SERIES. Model/Ref:

High-performance submersible pressure transmitter For level measurement Model LH-10

Pressure Equalising Valves Model , for Differential Pressure Gauges

Inverse Prop. Pressure-Relief Cart., Size 2 4

P9000 DESCRIPTION. For parts requiring RoHS compliance, please contact factory. P February /6

Types and approvals. Page 1/6. Data Sheet

6301 TYPE CAST IRON SAFETY VALVES

4/2 way Pneumatic Solenoid Valve

Type Operating Instructions. 2/2-way solenoid valve 2/2-Wege Magnetventil Electrovanne 2/2 voies.

Inverse Proportional Pressure-Relief Cart., Size 2 4

SITRANS F C MASSFLO. MASS flowmeters Sensor type MASS MC1 DN 50 - DN 100. Manual, supplement *083R9505* Order no.: FDK:521H1145

Mounting and Operating Instructions EB EN. Type Supply Pressure Regulator. with increased air capacity

E2K-L. Liquid Level Sensor That Is Unaffected by the Color of the Pipe or Liquid. Liquid Level Sensor. Ordering Information

Instruction Manual Contact Pressure Gauge

[Instruments for vacuum measurement, checking and adjustment] 3

Transcription:

FVA Trogflux variable area flowmeter Operating Instructions MECON GmbH

Imprint All rights reserved. It is prohibited to reproduce this document, or any parts thereof, without prior written authorization of MECON Flow Control Systems GmbH. Subject to change without notice. Copyright 2013 by MECON Flow Control Systems GmbH - Röntgenstraße 105-50169 Kerpen Page 2 / 20 www.mecon.de Operating instructions FVA Trogflux

Contents Contents 1 Safety Instructions 4 1.1 Intended use... 4 1.2 Certifications... 5 1.3 Safety instructions from the manufacturer... 5 2 Start-up 6 2.1 Standard device... 6 3 Installation 7 3.1 Installation instructions... 7 3.2 Installation... 7 4 Service 8 4.1 Storage... 8 4.2 Maintenance... 8 4.3 Returning the device to the manufacturer... 8 5 Device Description 9 5.1 Scope of delivery... 9 5.2 Versions... 9 5.3 Nameplate... 10 6 Description Code 11 7 Measuring range liquids 13 8 Measuring range air 14 9 Technical data 14 9.1 Pressure und temperature limits... 15 9.2 Dimensions... 16 9.3 Float selection... 16 10 Contacts 17 Operating instructions FVA Trogflux www.mecon.de Page 3 / 20

Safety Instructions 1 Safety Instructions 1.1 Intended use The FVA Trogflux variable area meters are used to measure the volume of transparent liquids and gases into closed piping. The variable area meters can also be used for flow monitoring if they are equipped with one or more switching contacts. Standard scales are available for liquids with a density of 1 kg/l (62.43 lb/cu.ft). The scales must be recalculated for all other media depending on the physical characteristics. The devices are particularly suitable for the measurement of: Water Clear liquids Gas flows Warning! The operator of these measuring devices is solely responsible for the suitability, intended use and corrosion resistance of the selected materials. It must be particularly ensured that the materials selected for the wetted parts of the flowmeter are suitable for the process media to be measured. The manufacturer is not liable for any damage resulting from improper or unintended use of these devices. No external loads may act upon the meter. The flowmeters are primarily designed for static applications. Caution! Hot surfaces resulting from hot process media. Danger of burns resulting from surface temperatures above 70 C. Take appropriate protective measures, for example contact protection. The design of the contact protection must meet the maximum permissible ambient temperature of the meter. The flowmeter may only be operated within the pressure and voltage limits specified on the name plate. Before taking the flowmeter out of operations, check that the unit is free of hazardous media and de-pressurized. Page 4 / 20 www.mecon.de Operating instructions FVA Trogflux

Safety Instructions 1.2 Certifications CE marking The manufacturer certifies that the device FVA Trogflux meets all statutory requirements of the following EC directives by applying the CE marking: Pressure equipment directive 97/23/EC The most hazardous permissable media are - for gases: fluids of group 2 - for liquids: fluids of group 1. 1.3 Safety instructions from the manufacturer Disclaimer The manufacturer will not be liable for any damage resulting from the use of its product, including, but not limited to direct, indirect, incidental, punitive and consequential damages. Any product purchased from the manufacturer is warranted in accordance with the relevant product documentation and our Terms and Conditions of Sale. The manufacturer reserves the right to revise the content of its documents, including this disclaimer, without prior notification, and will not be liable in any way for possible consequences of such changes. Product liability and warranty Mecon GmbH assumes no guarantee for repair work carried out by the customer without prior notification and consultation. Any instruments or parts rejected by a customer must be returned to us, if no other arrangement has been made. General information This manual is intended for the correct installation as well as operation and maintenance of the devices. Read the instructions carefully before installing the device and placing it into operation. Specially designed or customised models and specialised applications are not included in this manual. Operating instructions FVA Trogflux www.mecon.de Page 5 / 20

Start-up 2 Start-up 2.1 Standard device When starting up the unit, the following points must be observed: Make sure that the actual operating conditions (pressure and temperature) do not exceed the limits specified on the nameplate. Avoid float impact! Therefore it is recommended to start with a closed shut-off valve during commissioning and adjust the operating pressure by opening the valve slowly. In particular, the use of magnetic valves is not recommended in this case. When measuring liquids, make a careful release of the pipeline to prevent pressure peaks by gas bubbles. When commissioning new devices increasingly residues can stick on the float. Therefore we recommend to clean the equipment after a relatively short time. When using the devices in the lower measuring range the device must be operated at a higher flow rate for a short time to enable settling of the float. Exceptions for the measurements of gases: Provide valves downstream the flowmeter if pabs > 1,013 bar and usually upstream the flowmeter if pabs = 1,013 bar (no overpressure). Install a flow control valve close to the flowmeter (downstream), to prevent oscillations during the measurement. Adjust the operating pressure exactly to the reference pressure (during calibration) to prevent measurement errors. Page 6 / 20 www.mecon.de Operating instructions FVA Trogflux

Installation 3 Installation 3.1 Installation instructions i Information! All instruments are carefully checked for proper function before shipment. Check immediately on receipt, the outer packing carefully for damage or signs of improper handling. Report damage to the carrier and your competent sales staff. In such cases, a description of the defect, the type and the serial number of the device is indicated. i i Information! Unpack the unit carefully to avoid damage. Information! Check the completeness of the delivery by using the packing list. Check the name plate, if the delivered flow meter is according to your order. Especially check units with electrical components for the correct supply voltage. 3.2 Installation For specific device sizes the float is inserted with a plastic net for transport lock. This must be removed through the top of the meter before installation. After that the free movement of the float inside the flow tube should be checked again. The device must be mounted vertically and stress-free. Reductions, extensions, and control elements upstream and downstream of the meter have no influence on the measurement accuracy with liquids. For gases, however, the installation of the meter is recommended before valves to prevent compression oscillations. Since variable area flow meters are very sensitive to changes in flow, control elements should always be adjusted slowly. The calibration is carried out for defined conditions. It is essential to ensure compliance with the calibration conditions. Deviations of the density, pressure or temperature of gases, as well as density and viscosity of liquids, result in errors. Therefore it is essential to specify the following data of the medium in the order: the medium, the density and the viscosity at operating temperature and pressure. For gases, the exact reference point for the pressure (gauge or absolute pressure) is also required. Retrofitting of switching contacts is only possible when the floats are equipped with magnets. When commissioning the contact we recommend to ensure the correct position of the bistable contact by moving the float along the contact in flow direction. Operating instructions FVA Trogflux www.mecon.de Page 7 / 20

Service 4 Service 4.1 Storage Store the device dry and dust free. Avoid direct exposure to the sun and heat. Avoid external loads on the device. The admissible storage temperature for standard devices with electrical components: -40 +70 C. 4.2 Maintenance The devices are built for low maintenance operations but periodically the flowmeters should be inspected for signs of corrosion, mechanical wear as well as damage to the fitting and the display unit. We advice to carry out inspections at least once a year. For a detailed inspection and cleaning the device must be removed from the piping. Caution! Appropriate safety precautions have to be taken when removing the device. Always use new gaskets when reinstalling the device in the piping.. 4.3 Returning the device to the manufacturer This device has been carefully manufactured and tested. Should you nevertheless need to return a device to MECON GmbH please observe the following points: Caution! According to the actual waste disposal directives, the owner/customer is responsible for the waste management of hazardous and toxic waste. For reasons of environmental protection and safeguarding the health and safety of our personnel all devices sent to MECON GmbH to be repaired must be free of toxic and hazardous substances. This also applies to cavities of the devices. If necessary the customer is kindly requested to neutralize or rinse the devices before returning them to MECON. The customer has to confirm this by filling in an appropriate form which is available for download on the MECON website: www.mecon.de/en/declaration/contamination.pdf Caution! In case of returning devices which contain hazardous and toxic substances MECON GmbH is entitled to dispose of these substances at cost to the customer without any further notices Page 8 / 20 www.mecon.de Operating instructions FVA Trogflux

Device Description 5 Device Description 5.1 Scope of delivery 1 flowmeter FVA Trogflux 2 Operating instructions 3 Certificates (optional) Fig. 1 Scope of delivery i Information! Please check the delivery for completeness using the packing list. 5.2 Versions Fig. 2 Standard device with Fig. 3 Standard device with PVC adhesive bushing female thread The main components of the FVA Trogflux are the measuring tube made of plastics, the float and the connecting parts. A scale is printed on the flow tube (eg in l / h). The actual flowrate is read at Operating instructions FVA Trogflux www.mecon.de Page 9 / 20

Device Description the position of the largest diameter of the float. For process monitoring and control, the unit can be equipped with one or more contacts. Special features Product scales for liquids and gases Easy to install Low cost plastic version Short delivery times for standard versions 5.3 Nameplate Important! Please refer to the device nameplate to ensure that the device is built according to your order. Check particularly for the correct supply voltage. Fig. 4 Nameplate of the FVA Trogflux 1 Code number 2 TS Medium 3 PS 4 P max at T max Device specific code number Maximum temperature of the medium Maximum pressure of the medium Maximum pressure of the medium at temperature T max Page 10 / 20 www.mecon.de Operating instructions FVA Trogflux

Description Code 6 Description Code The descripion code consists of the following elements: 1 Plastic material for measuring cone 1 Trogamid 2 Polysulfon 2 Gasket material 1 Perbunan 4 Viton 8 EPDM 3 Measuring cone size AC 125 BC 315 CD 650 DD 1000 EDx 1600 FD 2500 GE 4000 HE 6500 JE 10000 KE 16000 LE 20000 ME 25000 4 Float material 1 Stainless steel (Mat.-No. 1.4305) 2 Stainless steel (Mat.-No. 1.4571/1.4404) 3 PVC, weighted 4 Stainless steel Mat.-No. 1.4571/SV/316Ti 5 Aluminium 6 PVC, not weighted 7 PVDF, not weighted 8 PVDF, weighted Operating instructions FVA Trogflux www.mecon.de Page 11 / 20

Description Code 5 Connection material 1 PVC / Standard, for plastic tubes only 2 Cast iron (only for G½, G1, G2) 3 Steel (not for G½, G1, G2) 4 Stainless steel 6 Connection form 1 Adhesive bushing (only made of PVC) 2 Female thread DIN ISO 228 3 Female thread NPT (NPT ANSI B1.20.1) 7 Connection size A Adhesive bushing B C D E F G H J Female thread G¼ Female thread G⅜ Female thread G½ Female thread G¾ Female thread G1 Female thread G1 ¼ Female thread G1 ½ Female thread G2 8 Contacts (only with magnetic floats) A Without contact C D E F G Contact K18/A (closes on falling below the limit) Contact K18/B (closes on exceeding the limit) 2 Contacts K18/A 2 Contacts K18/B One of each contact K18/A and K18/B 9 Float version 0 Standard 1 With magnet 2 Guided 10 Other versions B06 Y01 Y04 Y99 With calbration certificate Measured medium: always required, specify in plain text (Medium, Measuring range, Device range; Density; Viscosity, Operating temperature, Operating pressure) Silicone-free version Special version: specify in plain text Page 12 / 20 www.mecon.de Operating instructions FVA Trogflux

Measuring ranges for liquids 7 Measuring ranges for liquids Standard Measuring range for liquids (ρ=1 kg/l, Viscosity 1mPa s) Connection Measuring cone Dynamic Maximum measuring range for the selected floats Pressure loss float PVC Female Stainless steel PVC/PVDF PVC/PVDF Stainless Stainless Adhesive thread steel steel bushing [mm] with magnet weighted with magnet weighted viscosity l/h l/h l/h l/h l/h mbar 20 (G¼), C125 1:10 125 120 65 65 100 * 11 (G⅜), G½ C315 1:10 315 300 175 175 240 * 13 32 (G½), (G¾), G1 D650 1) 1:10 TS 650 TS 600 TS 500 TS 450 TS 400 * 17 D650 2) 1:10 PS 600 PS 550 PS450 PS 400 PS 350 * 17 D1000 1:10 1000 950 750 700 600 * 17 D1600 1:10 1600 1500 1250 1100 1000 * 20 D2500 1:10 2500 2400 2000 1750 1400 * 24 63 (G1 ¼), (G1 ½), G2 E4000 1:10 4000 * 3800 * 3200 3200 2500 * 25 E6500 1:10 6500 * 6400 * 5000 5000 4000 * 27 F10000 1:10 10000 * 9500 * 7500 7500 5500 * 32 G16000 1:4 16000* 16000 * 12500 12500-51 H20000 1:3 20000 * 19000 * - - - 65 J25000 1:3 25000* 24000 * - - - 91 (Connections in brackets are not standard) *) guided float 1) 2) Measuring cone made of Trogamid Measuring cone made of Polysulfon Operating instructions FVA Trogflux www.mecon.de Page 13 / 20

Measuring ranges for air 8 Measuring ranges for air Standard Measuring range for air (p abs = 1,013 bar, at T=0 C, ρ=1,293 kg/m³, viscosity 0,0181 mpa s) Connection Measuring cone Dyna- mic Maximum measuring range for the selected floats Pressure loss float PVC adhesive bushing [mm] Female threads 20 (G¼), (G⅜), G½ 32 (G½), (G¾), G1 Aluminium PVC/PVDF Aluminium with magnet not weighted weighted l/h l/h l/h l/h mbar C125 1:10 2000 2500 1400 2200 4 C315 1:10 5000 6400 3400 6000 5 D650 1) 1:10 TS 10000 TS 12000 TS 7000 TS 10000 7 D650 2) 1:10 PS9000 PS10500 PS 6500 PS 9000 7 D1000 1:10 16000 20000 11000 16000 7 D1600 1:10 28000 32000 18000 25000 7 D2500 1:10 40000 50000 28000 40000 8 63 (G1 ¼), (G1 ½), G2 E4000 1:10 64000 * 75000 * 45000 60000 9 E6500 1:10 100000 * 125000 * 75000 100000 10 F10000 1:10 160000 * 180000 * 120000 160000 13 G16000 1:4 280000 * 300000 * 190000 * - 23 H20000 1:3 350000 * 400000 * 240000 * - 31 J25000 1:3 430000 * 480000 * 300000 * - 43 (connections in brackets are not standard)) * guided float 1) 2) Measuring cone made of Trogamid Measuring cone made of Polysulfon Page 14 / 20 www.mecon.de Operating instructions FVA Trogflux

Technical Data 9 Technical Data Input Flow from the bottom to top upwards Pressure limit max. 10 bar Application conditions Environmental conditions (temperature limits) Measuring cone made of Trogamid max. 60 C (for water 50 C) Measuring cone made of Polysulfon max. 80 C Pressure- & temperature limits see table at chapter 9.1 (page 15) Measuring accuracy For liquids G 2,5 qg 50% (acc. VDE/VDI 3513, sheet 2) For air G 2,5 qg 50% (acc. VDE/VDI 3513, sheet 2) Measuring range For liquids 12,5 l/h 25 m³/h For gases 200 l/h 430 m³/h Measuring units Measuring cone D2500 and smaller l/h Measuring cone E4000 and larger m³/h Construction design Measuring tube material PVC-adhesive bushing, female thread, cast iron Measuring cone material Trogamid, Polysulfon Connection (union nut) PVC, cast iron Connenction (inlay part) PVC, cast iron, steel, stainless steel Float Stainless steel, Aluminium, PVC, PVDF Float guide rod Stainless steel (optionally for measuring cone C125 to D2500) Gasket NBR (NB2), FKM, EPDM Stopper Polysulfon 9.1 Pressure and temperature limits Trogamid Polysulfon T[ C] P e [bar] P e [bar] -10 bis +60 * 10,0 10,0 80-10,0 * for water only up to +50 C Connection parts PVC DIN 8062 Medium T [ C] P e [bar] For water and nonaggressive liquids 20 40 60 10,0 10,0 2,5 For aggressive media 20 40 60 P e = eff. pressure = overpressure 10,0 4,0 1,0 Operating instructions FVA Trogflux www.mecon.de Page 15 / 20

Technical Data 9.2 Dimensions Fig. 5 Trogflux, Dimensions in mm Adhesive bushing [mm] Connection Female thread Adhesive bushing Dimension A [mm] Female thread Cast iron PVC/PVDF/ stainless steel Dimension B [mm] Weight [kg] Adhesive bushing 20 G½; NPT ½" 346 ± 4 350 ± 4 366 ± 4 306 0,4 32 G1; NPT 1" 356 ± 4 358 ± 4 358 ± 4 306 0,7 63 G2; NPT 2" 389 ± 4 379 ± 4 366 ± 4 306 2,2 9.3 Float selection There are three versions of floats available: Float non guided (A) Float guided (B) Float for stable viscosity (C) (reading edge) Fig. 6 Versions of float Page 16 / 20 www.mecon.de Operating instructions FVA Trogflux

Contacts 10 Contacts The bistable contact K18 is intended for signaling of limit values and for controlling purposes. Special features bistable function high vibration resistance no interaction between contacts low cost plastic version easy to use elelctrical connection Mode of operation A bistable reed contact consists of a spring contact which is covered by a glass tube filled with inert gas. It is operated by a magnetic field. This magnetic field is generated by a permanent magnet inside the float of a MECON flowmeter. There are two versions availabe: Fig. 7 Contact K 18 A K 18 A: contact closes on falling below the limit K 18 B: contact closes on exceeding the limit Fig. 8 Contact K 18 B Electrical loadability The spring contacts of the K18 are sensitive to current overload (max. 500 ma). A high current could lead to a welding effect and this will damage the contact blades this specifically applies to inductive loads e.g. relais (high self-induction). Protective circuits At great cable lengths (cable capacity) it is recomended to connect a protectice resitor in series to contact K18 A(B) for current limitation. Fig. 9 Protective circuit for current limitation Operating instructions FVA Trogflux www.mecon.de Page 17 / 20

Contacts When using a DC power supply in combination with an inductive load it is recomended to connect a diode in parallel to the load. Fig. 10 Protective circuit for inductive loads and DC power supply Technical data Contact material Rhodium (with inert gas) max. switching capacity 5 W / 10 VA Max. switching voltage 250 V DC/AC Contact resistance 0,1 Ω Isolation resistance 10 11 Ω Contact closing time 2 ms Contact opening time 0,07 ms Frequency of operation 2000 Hz Duration of bounce 0,5 ms Temperature range -40 C to +80 C Material of housing Plastics Electrical connection Rectangular connector acc. to DIN EN 175301-803 (previously DIN 43 650) Protection class IP 65 Max. starting current (peek) 0,5 A Max. switching current 230 V DC : 21 ma 115 V DC : 43 ma 24 V DC : 0,2 A 10 V DC : 0,5 A Warning! Observe in any case the max. switching capacity and the max. starting current otherwise a welding effect will damage the contact blades. Page 18 / 20 www.mecon.de Operating instructions FVA Trogflux

Contacts Installation of the connection cable to the connector: 1. Remove the cable gland (9) and take out the gasket kit (8, 7, 6). 2. Remove the locking screw (5) and pull of the housing (4) from the insert connector (3). 3. Insert the connection cable through the cable gland (9), the gasket kit (6, 7, 8) and the housing. 4. Connect the wires to terminal 1 and 2 of the insert connector. 5. Assamble the rectangular connector in reverse order as described above. Please note, that the cable outlet can be varied by rotating the insert connector (4) through 90. Fig. 11 Explosion drawing contact K 18 Commissioning: When commissioning the contact K18 we recommend to ensure the correct position of the bistable contact by moving the float along the K18 in flow direction. Operating instructions FVA Trogflux www.mecon.de Page 19 / 20

Mecon GmbH Röntgenstraße 105 D 50169 Kerpen Phone: +49 (0)2237 600 06 0 Fax: +49 (0)2237 600 06 20 Email: customerservice@mecon.de www.mecon.de OI_FVA_Trogflux Subject to change without notice Copyright